All the vulnerabilites related to Siemens - SIMATIC ET 200MP IM 155-5 PN BA
cve-2017-2680
Vulnerability from cvelistv5
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
▼ | URL | Tags |
---|---|---|
http://www.securitytracker.com/id/1038463 | vdb-entry, x_refsource_SECTRACK | |
http://www.securityfocus.com/bid/98369 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf | x_refsource_CONFIRM | |
https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | x_refsource_CONFIRM | |
https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/html/ssa-293562.html | ||
https://cert-portal.siemens.com/productcert/html/ssa-284673.html | ||
https://cert-portal.siemens.com/productcert/html/ssa-546832.html |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2017-2680", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-09T13:26:04.237652Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-09T13:26:15.327Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-05T14:02:07.270Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1 Patch04" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1 Patch03" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0 Patch01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 12\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 15\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 19\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 22\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "IE/AS-i Link PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "IE/PB-Link (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.03" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W-700 IEEE 802.11n family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200 family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.4.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X414", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.10.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM-400 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR-500 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542SP-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-7 LTE US", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 OPC UA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC DK-16xx PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V1.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 HR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 SR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 UR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF650R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF680R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF685R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-200 SMART", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.X.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Basic", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Standard", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0.0" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 HF26" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.4 SP1 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V4.7: All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP5 HF7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF31" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 SP3 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.0 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF30" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.4 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.5 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS V90 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.01" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS ACT 3SU1 interface module PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Motor Starter M200D PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Soft Starter 3RW44 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SITOP PSU8600 PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2.0" } ] }, { "defaultStatus": "unknown", "product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.2.0" } ] }, { "defaultStatus": "unknown", "product": "Softnet PROFINET IO for PC-based Windows systems", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1" } ] } ], "descriptions": [ { "lang": "en", "value": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:33:18.492Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-2680", "datePublished": "2017-05-11T01:00:00", "dateReserved": "2016-12-01T00:00:00", "dateUpdated": "2024-09-10T09:33:18.492Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-10936
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: 0 < * |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "dk_standard_ethernet_controller_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:ek-ertec_200_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ek-ertec_200_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:ek-ertec_200p_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ek-ertec_200p_firmware", "vendor": "siemens", "versions": [ { "lessThan": "4.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cfu_pa", "vendor": "siemens", "versions": [ { "lessThan": "v1.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et200ecopn_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et200ecopn_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et200s_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et200s_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200al_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200m_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200mp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v4.3.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200pro_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200s_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200sp_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_hmi_comfort_outdoor_panels", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0", "vendor": "siemens", "versions": [ { "lessThan": "v4.2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_profinet_driver", "vendor": "siemens", "versions": [ { "lessThan": "v2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_314_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_315-2_dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_315f-2_dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_315f-2_dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_317-2_dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_pn\\/dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_317-2_pn\\/dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_319-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_319-3_pn\\/dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_cpu_412-2_pn", "vendor": "siemens", "versions": [ { "lessThan": "v7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\/dp:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_cpu_414-3_pn\\/dp", "vendor": "siemens", "versions": [ { "lessThan": "v7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\/dp:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_cpu_416-3_pn\\/dp", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "v7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-400_h_v6_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_h_v6_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "v6.0.9", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v6_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_pn\\/dp_v6_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-410_cpu_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-410_cpu_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v8.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-1200_cpu", "vendor": "siemens", "versions": [ { "lessThan": "v4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-1500_cpu", "vendor": "siemens", "versions": [ { "lessThan": "v2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-1500_controller", "vendor": "siemens", "versions": [ { "lessThan": "v2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_tdc_cp51m1_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_tdc_cpu555_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_winac_rtx_2010", "vendor": "siemens", "versions": [ { "lessThan": "v2010_sp3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_winac_rtx_\\(f\\)_2010", "vendor": "siemens", "versions": [ { "lessThan": "v2010_sp3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_dcm", "vendor": "siemens", "versions": [ { "lessThan": "v1.5_hf1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_dcp", "vendor": "siemens", "versions": [ { "lessThan": "v1.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g110m", "vendor": "siemens", "versions": [ { "lessThan": "v4.7_sp10_hf5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g120", "vendor": "siemens", "versions": [ { "lessThan": "v4.7_sp10_hf5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g130", "vendor": "siemens", "versions": [ { "lessThan": "v4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g150", "vendor": "siemens", "versions": [ { "lessThan": "v4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_gh150", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_gl150", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_gm150", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_s110", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_s120", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_sl150", "vendor": "siemens", "versions": [ { "lessThan": "v4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_sl150", "vendor": "siemens", "versions": [ { "lessThan": "v4.7_hf33", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_sm120", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinumerik_828d", "vendor": "siemens", "versions": [ { "lessThan": "v4.8_sp5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinumerik_840d_sl", "vendor": "siemens", "versions": [ { "lessThan": "v4.8_sp6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:siplus_s7-300_cpu_314:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "siplus_s7-300_cpu_314", "vendor": "siemens", "versions": [ { "lessThan": "v3.3.17", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2019-10936", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-09T14:36:59.481395Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-09T15:59:12.602Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-04T22:40:15.253Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.6 Patch 01" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU PA", "vendor": "Siemens", "versions": [ { "lessThan": "V1.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Outdoor Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI KTP Mobile Panels", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PROFINET Driver", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 412-2 PN V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.9", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.5 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M V4.7 PN Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP10 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP10 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 4.8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 4.8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 Control Unit", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 4.8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF33" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP5" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP6" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices improperly handle large amounts of specially crafted UDP packets.\r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:03:55.957Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-10936", "datePublished": "2019-10-10T00:00:00", "dateReserved": "2019-04-08T00:00:00", "dateUpdated": "2024-08-04T22:40:15.253Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-2681
Vulnerability from cvelistv5
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
▼ | URL | Tags |
---|---|---|
http://www.securitytracker.com/id/1038463 | vdb-entry, x_refsource_SECTRACK | |
http://www.securityfocus.com/bid/98369 | vdb-entry, x_refsource_BID | |
https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/html/ssa-293562.html |
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: All versions < V4.1.1 Patch04 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2017-2681", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-23T20:22:19.045364Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-23T20:22:26.181Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-05T14:02:07.386Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1 Patch04" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1 Patch03" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0 Patch01" } ] }, { "defaultStatus": "unknown", "product": "IE/AS-i Link PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "IE/PB-Link (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.03" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W-700 IEEE 802.11n family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200 family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.4.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X414", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.10.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM-400 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR-500 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542SP-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 OPC UA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC DK-16xx PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V1.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 HR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 SR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 UR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF650R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF680R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF685R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-200 SMART", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.X.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Basic", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Standard", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0.0" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.4 SP1 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V4.7: All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 SP3 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS V90 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.01" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS ACT 3SU1 interface module PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Motor Starter M200D PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Soft Starter 3RW44 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SITOP PSU8600 PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2.0" } ] }, { "defaultStatus": "unknown", "product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.2.0" } ] }, { "defaultStatus": "unknown", "product": "Softnet PROFINET IO for PC-based Windows systems", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1" } ] } ], "descriptions": [ { "lang": "en", "value": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:33:20.658Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-2681", "datePublished": "2017-05-11T10:00:00", "dateReserved": "2016-12-01T00:00:00", "dateUpdated": "2024-09-10T09:33:20.658Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-12741
Vulnerability from cvelistv5
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
▼ | URL | Tags |
---|---|---|
https://www.securityfocus.com/bid/101964 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/html/ssa-346262.html | ||
https://cert-portal.siemens.com/productcert/html/ssa-546832.html | ||
https://cert-portal.siemens.com/productcert/html/ssa-141614.html |
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: All versions < V4.1.1 Patch 05 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T18:51:06.315Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "101964", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "https://www.securityfocus.com/bid/101964" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-346262.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-141614.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1 Patch 05" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Compact Field Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V1.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-200 SMART", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.03.01" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.X.16", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6\u00a0and below\u00a0CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 HF26" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION P V4.4 and V4.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 HF5" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION P V5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.4 SP1 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP9 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP9 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF29" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF29" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP5 HF7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF31" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 SP3 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF29" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF29" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.0 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF30" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.4 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.5 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS V90 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.02" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Soft Starter 3RW44 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:03:53.948Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "101964", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "https://www.securityfocus.com/bid/101964" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-346262.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-141614.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-12741", "datePublished": "2017-12-26T04:00:00", "dateReserved": "2017-08-09T00:00:00", "dateUpdated": "2024-08-05T18:51:06.315Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-201910-1595
Vulnerability from variot
Affected devices improperly handle large amounts of specially crafted UDP packets.
This could allow an unauthenticated remote attacker to trigger a denial of service condition. Several Siemens products are vulnerable to resource exhaustion.Denial of service (DoS) May be in a state. Siemens SIMATIC CFU PA and so on are the products of Germany's Siemens company. Siemens SIMATIC CFU PA is a compact field device. SIMATIC ET 200AL is a distributed I / O system module. SIMATIC ET 200M is a modular I / O system module for control cabinets for high density channel applications. A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), SIMATIC CFU PA (All versions < V1.2.0), SIMATIC ET 200AL (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM 155-5 PN BA (All versions < V4.3.0), SIMATIC ET 200MP IM 155-5 PN HF (All versions), SIMATIC ET 200MP IM 155-5 PN ST (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM 155-6 PN BA (All versions), SIMATIC ET 200SP IM 155-6 PN HA (All versions), SIMATIC ET 200SP IM 155-6 PN HF (All versions < V4.2.2), SIMATIC ET 200SP IM 155-6 PN HS (All versions), SIMATIC ET 200SP IM 155-6 PN ST (All versions), SIMATIC ET 200SP IM 155-6 PN/2 HF (All versions < V4.2.2), SIMATIC ET 200SP IM 155-6 PN/3 HF (All versions < V4.2.1), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels (All versions), SIMATIC PN/PN Coupler (All versions), SIMATIC PROFINET Driver (All versions < V2.1), SIMATIC S7-1200 CPU family (incl. F) (All versions), SIMATIC S7-1500 CPU family (incl. F) (All versions < V2.0), SIMATIC S7-300 CPU family (incl. F) (All versions), SIMATIC S7-400 PN/DP V7 (incl. F) (All versions), SIMATIC S7-400 V6 (incl F) and below (All versions), SIMATIC S7-400H V6 (All versions < V6.0.9), SIMATIC S7-410 V8 (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions), SINAMICS G110M V4.7 (PN Control Unit) (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 (PN Control Unit) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 (Control Unit) (All versions < 4.8), SINAMICS G150 (Control Unit) (All versions < 4.8), SINAMICS GH150 V4.7 (Control Unit) (All versions), SINAMICS GL150 V4.7 (Control Unit) (All versions), SINAMICS GM150 V4.7 (Control Unit) (All versions), SINAMICS S110 (Control Unit) (All versions), SINAMICS S120 V4.7 (Control Unit) (All versions), SINAMICS S150 (Control Unit) (All versions < 4.8), SINAMICS SL150 V4.7 (Control Unit) (All versions < V4.7 HF33), SINAMICS SM120 V4.7 (Control Unit) (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. SIMATIC S7-1500 CPU is a CPU (central processing unit) module. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system. The following products and versions are affected: Siemens SIMATIC S7-1500 CPU series (including: related ET200 CPUs and SIPLUS variants); SIMATIC S7-1500 Software Controller; SIMATIC TDC CP51M1; SIMATIC TDC CPU555; SINAMICS DCM, etc
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201910-1595", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic cfu pa", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "1.2.0" }, { "model": "simatic profinet driver", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "2.1" }, { "model": "dk standard ethernet controller", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic et 200al", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic et 200m", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic et 200s", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 1.0, "vendor": "sinumerik 828d", "version": "4.8" }, { "model": "simatic s7-400 dp v7", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-300 cpu 314", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics gl150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics g120", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic et 200sp im 155-6 pn hs", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinumerik 828d", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-1500 cpu 1512c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "sinumerik 840d sl", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics g130", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "simatic s7-1500t cpu", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "sinamics g130", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "simatic et 200sp im 155-6 pn\\/3 hf", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.2.1" }, { "model": "sinamics dcm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.5" }, { "model": "ek-ertec 200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et 200s", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic pn\\/pn coupler", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.2.1" }, { "model": "simatic s7-1200 cpu 1214c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.4.0" }, { "model": "sinamics s150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "simatic s7-400 v6", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.0.9" }, { "model": "sinamics g110m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic s7-300 cpu 315", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "sinumerik 828d", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic et 200ecopn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et 200sp im 155-6 pn st", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et 200sp im 155-6 pn\\/2 hf", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.2.2" }, { "model": "sinamics s110", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sl150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic s7-1200 cpu 1212c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.4.0" }, { "model": "simatic et 200mp im 155-5 pn hf", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.4.0" }, { "model": "simatic s7-300 cpu 313", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "simatic s7-300 cpu 318-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "simatic s7-300 cpu 312 ifm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "sinamics s150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "simatic et 200pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1200 cpu", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.4.0" }, { "model": "sinamics g110m", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic et 200sp im 155-6 pn ba", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-410 v8", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.2.2" }, { "model": "simatic et 200mp im 155-5 pn ba", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3.0" }, { "model": "simatic s7-300 cpu 316-2 dp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "sinamics gm150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic s7-300 cpu", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "simatic winac rtx \\", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2010" }, { "model": "ek-ertec 200p", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.6" }, { "model": "simatic et 200m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-300 cpu 314 ifm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "dk standard ethernet controller", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1500 cpu 1511c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-300 cpu 315-2 dp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "sinamics g150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "sinamics sm120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinamics s120", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "simatic hmi ktp mobile panels", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "ek-ertec 200p", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.6" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1500 cpu 1518", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "sinamics gm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic winac rtx \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2010" }, { "model": "sinamics dcp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.3" }, { "model": "sinamics gl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-400 pn v7", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et 200sp im 155-6 pn ha", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1500s cpu", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-400h v6", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.0.9" }, { "model": "sinamics g120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic et 200al", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics g150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "simatic et 200sp im 155-6 pn hf", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.2.2" }, { "model": "simatic et 200mp im 155-5 pn st", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics dcm", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "1.5" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1200 cpu 1211c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.4.0" }, { "model": "sinamics s120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "simatic s7-1500 cpu", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "ek-ertec 200", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "ek-ertec 200p p", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cfu pa", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200mp im 155-5 pn ba", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200mp im 155-5 pn hf", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200mp im 155-5 pn st", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "ek-ertec", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "200" }, { "model": "ek-ertec 200p", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et 200mp im pn ba", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-5\u003c4.2.3" }, { "model": "simatic et 200mp im pn hf", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-5" }, { "model": "simatic et 200mp im pn st", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-5" }, { "model": "simatic et 200sp im pn ba", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-6" }, { "model": "simatic et 200sp im pn ha", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-6" }, { "model": "simatic et 200sp im pn hf", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-6\u003c4.2.2" }, { "model": "simatic et 200sp im pn hs", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-6" }, { "model": "simatic et 200sp im pn st", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-6" }, { "model": "simatic et 200sp im pn/2 hf", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-6\u003c4.2.2" }, { "model": "simatic et 200sp im pn/3 hf", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-6\u003c4.2.1" }, { "model": "simatic et 200ecopn", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et 200pro", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort outdoor panels 7\" \u0026 15\"", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort panels 4\" 22\"", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic pn/pn coupler", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-300 cpu family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn/dp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v7" }, { "model": "simatic s7-400 and below", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v6" }, { "model": "simatic s7-400h", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v6\u003c6.0.9" }, { "model": "simatic s7-410", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v8" }, { "model": "simatic winac rtx", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "2010" }, { "model": "sinamics dcm", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics dcp", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics g110m sp10 hf5", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7\u003cv4.7" }, { "model": "sinamics g120 sp10 hf5", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7\u003cv4.7" }, { "model": "sinamics g130", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "sinamics g150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics gh150", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "sinamics gl150", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "sinamics gm150", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "sinamics s110", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics s120", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "sinamics s150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics sl150", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "sinamics sm120", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "sinumerik 828d sp5", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v4.8" }, { "model": "sinumerik 840d sl", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "dk standard ethernet controller", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200s", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp im 155 6 pn ba", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp im 155 6 pn ha", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp im 155 6 pn hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp im 155 6 pn hs", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp im 155 6 pn st", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp im 155 6 pn 2 hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp im 155 6 pn 3 hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200ecopn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200pro", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ek ertec 200", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort outdoor panels 7", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort outdoor panels 15", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort panels 4", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort panels 22", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic pn pn coupler", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic profinet driver", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1200 cpu", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1200 cpu 1211c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1200 cpu 1212c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ek ertec 200p", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1200 cpu 1214c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500 cpu", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500s cpu", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500t cpu", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500 cpu 1518", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500 cpu 1511c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500 cpu 1512c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 312 ifm", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 313", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cfu pa", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 314", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 314 ifm", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 315", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 315 2 dp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 316 2 dp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 318 2", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400 pn v7", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400 dp v7", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400 v6", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400h v6", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200al", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 410 v8", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic winac rtx f 2010", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics dcm", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics dcm", "version": "1.5" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics dcp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g110m", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g120", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g130", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics gl150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics gm150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200m", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s110", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s120", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics sl150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics sm120", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinumerik 828d", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinumerik 840d sl", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200mp im 155 5 pn ba", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200mp im 155 5 pn hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200mp im 155 5 pn st", "version": "*" } ], "sources": [ { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "db": "NVD", "id": "CVE-2019-10936" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:dk_standard_ethernet_controller_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:ek-ertec_200_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:ek-ertec_200p_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cfu_pa_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200al_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200m_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200mp_im_155-5_pn_ba_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200mp_im_155-5_pn_hf_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200mp_im_155-5_pn_st_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200s_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-010605" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported this vulnerability to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-201910-639" } ], "trust": 0.6 }, "cve": "CVE-2019-10936", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2019-10936", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2019-36853", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "ea2714fa-253a-4380-82d5-35652a5540fb", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-142532", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2019-10936", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2019-10936", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-10936", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2019-10936", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2019-10936", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-36853", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201910-639", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-142532", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "VULHUB", "id": "VHN-142532" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "db": "CNNVD", "id": "CNNVD-201910-639" }, { "db": "NVD", "id": "CVE-2019-10936" }, { "db": "NVD", "id": "CVE-2019-10936" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Affected devices improperly handle large amounts of specially crafted UDP packets. \r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition. Several Siemens products are vulnerable to resource exhaustion.Denial of service (DoS) May be in a state. Siemens SIMATIC CFU PA and so on are the products of Germany\u0027s Siemens company. Siemens SIMATIC CFU PA is a compact field device. SIMATIC ET 200AL is a distributed I / O system module. SIMATIC ET 200M is a modular I / O system module for control cabinets for high density channel applications. A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), SIMATIC CFU PA (All versions \u003c V1.2.0), SIMATIC ET 200AL (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM 155-5 PN BA (All versions \u003c V4.3.0), SIMATIC ET 200MP IM 155-5 PN HF (All versions), SIMATIC ET 200MP IM 155-5 PN ST (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM 155-6 PN BA (All versions), SIMATIC ET 200SP IM 155-6 PN HA (All versions), SIMATIC ET 200SP IM 155-6 PN HF (All versions \u003c V4.2.2), SIMATIC ET 200SP IM 155-6 PN HS (All versions), SIMATIC ET 200SP IM 155-6 PN ST (All versions), SIMATIC ET 200SP IM 155-6 PN/2 HF (All versions \u003c V4.2.2), SIMATIC ET 200SP IM 155-6 PN/3 HF (All versions \u003c V4.2.1), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions), SIMATIC HMI Comfort Panels 4\" - 22\" (All versions), SIMATIC HMI KTP Mobile Panels (All versions), SIMATIC PN/PN Coupler (All versions), SIMATIC PROFINET Driver (All versions \u003c V2.1), SIMATIC S7-1200 CPU family (incl. F) (All versions), SIMATIC S7-1500 CPU family (incl. F) (All versions \u003c V2.0), SIMATIC S7-300 CPU family (incl. F) (All versions), SIMATIC S7-400 PN/DP V7 (incl. F) (All versions), SIMATIC S7-400 V6 (incl F) and below (All versions), SIMATIC S7-400H V6 (All versions \u003c V6.0.9), SIMATIC S7-410 V8 (All versions), SIMATIC WinAC RTX (F) 2010 (All versions \u003c SIMATIC WinAC RTX 2010 SP3), SINAMICS DCM (All versions \u003c V1.5 HF1), SINAMICS DCP (All versions), SINAMICS G110M V4.7 (PN Control Unit) (All versions \u003c V4.7 SP10 HF5), SINAMICS G120 V4.7 (PN Control Unit) (All versions \u003c V4.7 SP10 HF5), SINAMICS G130 V4.7 (Control Unit) (All versions \u003c 4.8), SINAMICS G150 (Control Unit) (All versions \u003c 4.8), SINAMICS GH150 V4.7 (Control Unit) (All versions), SINAMICS GL150 V4.7 (Control Unit) (All versions), SINAMICS GM150 V4.7 (Control Unit) (All versions), SINAMICS S110 (Control Unit) (All versions), SINAMICS S120 V4.7 (Control Unit) (All versions), SINAMICS S150 (Control Unit) (All versions \u003c 4.8), SINAMICS SL150 V4.7 (Control Unit) (All versions \u003c V4.7 HF33), SINAMICS SM120 V4.7 (Control Unit) (All versions), SINUMERIK 828D (All versions \u003c V4.8 SP5), SINUMERIK 840D sl (All versions). The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. SIMATIC S7-1500 CPU is a CPU (central processing unit) module. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system. The following products and versions are affected: Siemens SIMATIC S7-1500 CPU series (including: related ET200 CPUs and SIPLUS variants); SIMATIC S7-1500 Software Controller; SIMATIC TDC CP51M1; SIMATIC TDC CPU555; SINAMICS DCM, etc", "sources": [ { "db": "NVD", "id": "CVE-2019-10936" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "VULHUB", "id": "VHN-142532" } ], "trust": 2.43 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-10936", "trust": 3.3 }, { "db": "SIEMENS", "id": "SSA-473245", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-19-283-02", "trust": 1.4 }, { "db": "CNNVD", "id": "CNNVD-201910-639", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2019-36853", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-010605", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2019.3813", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.3813.3", "trust": 0.6 }, { "db": "IVD", "id": "EA2714FA-253A-4380-82D5-35652A5540FB", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-142532", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "VULHUB", "id": "VHN-142532" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "db": "CNNVD", "id": "CNNVD-201910-639" }, { "db": "NVD", "id": "CVE-2019-10936" } ] }, "id": "VAR-201910-1595", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "VULHUB", "id": "VHN-142532" } ], "trust": 1.6334674204444446 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "CNVD", "id": "CNVD-2019-36853" } ] }, "last_update_date": "2024-11-23T22:58:29.466000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-473245", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" }, { "title": "Patch for Multiple Siemens Product Denial of Service Vulnerabilities (CNVD-2019-36853)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/186551" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-142532" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "db": "NVD", "id": "CVE-2019-10936" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" }, { "trust": 1.4, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-283-02" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-10936" }, { "trust": 1.2, "url": "https://vigilance.fr/vulnerability/simatic-denial-of-service-via-profinet-udp-packets-30562" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10936" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.3813/" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-19-283-02" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.3813.3/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "VULHUB", "id": "VHN-142532" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "db": "CNNVD", "id": "CNNVD-201910-639" }, { "db": "NVD", "id": "CVE-2019-10936" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "VULHUB", "id": "VHN-142532" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "db": "CNNVD", "id": "CNNVD-201910-639" }, { "db": "NVD", "id": "CVE-2019-10936" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-10-23T00:00:00", "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "date": "2019-10-23T00:00:00", "db": "CNVD", "id": "CNVD-2019-36853" }, { "date": "2019-10-10T00:00:00", "db": "VULHUB", "id": "VHN-142532" }, { "date": "2019-10-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "date": "2019-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-201910-639" }, { "date": "2019-10-10T14:15:14.707000", "db": "NVD", "id": "CVE-2019-10936" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-10-23T00:00:00", "db": "CNVD", "id": "CNVD-2019-36853" }, { "date": "2023-01-10T00:00:00", "db": "VULHUB", "id": "VHN-142532" }, { "date": "2019-11-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "date": "2023-05-10T00:00:00", "db": "CNNVD", "id": "CNNVD-201910-639" }, { "date": "2024-11-21T04:20:11.257000", "db": "NVD", "id": "CVE-2019-10936" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201910-639" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Multiple Siemens products vulnerable to resource depletion", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-010605" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Resource management error", "sources": [ { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "CNNVD", "id": "CNNVD-201910-639" } ], "trust": 0.8 } }