All the vulnerabilites related to Siemens - SIMATIC CP 1243-7 LTE
cve-2023-30755
Vulnerability from cvelistv5
5.9 (Medium) - CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) |
Version: 0 < V3.5.20 |
||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-30755", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T15:10:26.969445Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T15:10:35.515Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-7 LTE", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagBase", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagMonitor", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS TIM 1531 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V2.4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "TIM 1531 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V2.4.8", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-7 LTE (All versions \u003c V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.4.8). The web server of the affected devices do not properly handle the shutdown or reboot request, which could lead to the clean up of certain resources. \r\n\r\nThis could allow a remote attacker with elevated privileges to cause a denial of service condition in the system." } ], "metrics": [ { "cvssV3_1": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:33:39.215Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-423808.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-30755", "datePublished": "2024-09-10T09:33:39.215Z", "dateReserved": "2023-04-14T11:16:56.497Z", "dateUpdated": "2024-09-10T15:10:35.515Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-38380
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) |
Version: 0 < V3.4.29 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:39:13.213Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-693975.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-625862.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.4.29", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.4.29", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.4.29", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-7 LTE", "vendor": "Siemens", "versions": [ { "lessThan": "V3.4.29", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V3.4.29", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1542SP-1", "vendor": "Siemens", "versions": [ { "lessThan": "V2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1542SP-1 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543-1", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.37", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543SP-1", "vendor": "Siemens", "versions": [ { "lessThan": "V2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S210 (6SL5...)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.1 HF2", "status": "affected", "version": "V6.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC", "vendor": "Siemens", "versions": [ { "lessThan": "V2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 1543-1", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.37", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions \u003c V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SINAMICS S210 (6SL5...) (All versions \u003e= V6.1 \u003c V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions \u003c V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used.\r\n\r\nAn attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-401", "description": "CWE-401: Missing Release of Memory after Effective Lifetime", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-11T14:19:50.234Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-693975.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-625862.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-38380", "datePublished": "2023-12-12T11:26:36.173Z", "dateReserved": "2023-07-17T13:06:36.758Z", "dateUpdated": "2024-08-02T17:39:13.213Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-30756
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) |
Version: 0 < V3.5.20 |
||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-30756", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T15:09:52.396615Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T15:10:00.273Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-7 LTE", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagBase", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagMonitor", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS TIM 1531 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V2.4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "TIM 1531 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V2.4.8", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-7 LTE (All versions \u003c V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.4.8). The web server of the affected devices do not properly handle certain errors when using the Expect HTTP request header, resulting in NULL dereference.\r\n\r\nThis could allow a remote attacker with no privileges to cause a denial of service condition in the system." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:33:40.640Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-423808.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-30756", "datePublished": "2024-09-10T09:33:40.640Z", "dateReserved": "2023-04-14T11:16:56.497Z", "dateUpdated": "2024-09-10T15:10:00.273Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-28827
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) |
Version: 0 < V3.5.20 |
||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-28827", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T15:10:54.020229Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T15:11:03.085Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-7 LTE", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagBase", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagMonitor", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS TIM 1531 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V2.4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "TIM 1531 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V2.4.8", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-7 LTE (All versions \u003c V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.4.8). The web server of the affected devices do not properly handle certain requests, causing a timeout in the watchdog, which could lead to the clean up of pointers. \r\n\r\nThis could allow a remote attacker to cause a denial of service condition in the system." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:33:37.794Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-423808.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-28827", "datePublished": "2024-09-10T09:33:37.794Z", "dateReserved": "2023-03-24T15:17:29.557Z", "dateUpdated": "2024-09-10T15:11:03.085Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-202312-0253
Vulnerability from variot
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions < V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SINAMICS S210 (6SL5...) (All versions >= V6.1 < V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions < V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used.
An attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product. 6gk7243-8rx30-0xe0 firmware, 6gk7543-1ax00-0xe0 firmware, 6ag1543-1ax00-2xe0 Multiple Siemens products, including firmware, are vulnerable to a lack of freeing memory after expiration.Service operation interruption (DoS) It may be in a state. The SIMATIC CP 1242 and CP 1243 associated processors connect the SIMATIC S7-1200 controller to the wide area network (WAN). They offer integrated security features such as firewalls, virtual private networks (VPNs), and support for other data encryption protocols. The SIMATIC CP 1543-1 communications processor connects the SIMATIC S7-1500 controller to Ethernet. They offer integrated security features such as firewalls, virtual private networks (VPNs), and support for other data encryption protocols.
A denial of service vulnerability exists in the Siemens Industrial Products Web Server
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0253", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "6gk7243-8rx30-0xe0", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinamics s210", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "simatic cp 1243-1 iec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1243-1 dnp3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinamics s210", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "simatic cp 1242-7 v2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1243-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1243-7 lte", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinamics s210", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "6.1" }, { "model": "6ag1543-1ax00-2xe0", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6gk7543-1ax00-0xe0", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1243-7 lte", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6ag1543-1ax00-2xe0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics s210", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk7243-8rx30-0xe0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1243-1", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1243-1 iec", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1243-1 dnp3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk7543-1ax00-0xe0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1242-7 v2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp irc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-8" }, { "model": "simatic cp dnp3", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-1" }, { "model": "simatic cp iec", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-1" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1242-7v2" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-1" }, { "model": "simatic cp lte", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-7" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1543-1" }, { "model": "sinamics s210 hf2", "scope": "gte", "trust": 0.6, "vendor": "siemens", "version": "v6.1,\u003cv6.1" }, { "model": "siplus net cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1543-1" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97273" }, { "db": "JVNDB", "id": "JVNDB-2023-019860" }, { "db": "NVD", "id": "CVE-2023-38380" } ] }, "cve": "CVE-2023-38380", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2023-97273", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2023-38380", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2023-019860", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2023-38380", "trust": 1.0, "value": "HIGH" }, { "author": "OTHER", "id": "JVNDB-2023-019860", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2023-97273", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97273" }, { "db": "JVNDB", "id": "JVNDB-2023-019860" }, { "db": "NVD", "id": "CVE-2023-38380" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions \u003c V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SINAMICS S210 (6SL5...) (All versions \u003e= V6.1 \u003c V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions \u003c V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used. \r\n\r\nAn attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product. 6gk7243-8rx30-0xe0 firmware, 6gk7543-1ax00-0xe0 firmware, 6ag1543-1ax00-2xe0 Multiple Siemens products, including firmware, are vulnerable to a lack of freeing memory after expiration.Service operation interruption (DoS) It may be in a state. The SIMATIC CP 1242 and CP 1243 associated processors connect the SIMATIC S7-1200 controller to the wide area network (WAN). They offer integrated security features such as firewalls, virtual private networks (VPNs), and support for other data encryption protocols. The SIMATIC CP 1543-1 communications processor connects the SIMATIC S7-1500 controller to Ethernet. They offer integrated security features such as firewalls, virtual private networks (VPNs), and support for other data encryption protocols. \n\r\n\r\nA denial of service vulnerability exists in the Siemens Industrial Products Web Server", "sources": [ { "db": "NVD", "id": "CVE-2023-38380" }, { "db": "JVNDB", "id": "JVNDB-2023-019860" }, { "db": "CNVD", "id": "CNVD-2023-97273" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-38380", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-693975", "trust": 2.4 }, { "db": "SIEMENS", "id": "SSA-139628", "trust": 1.0 }, { "db": "SIEMENS", "id": "SSA-625862", "trust": 1.0 }, { "db": "JVN", "id": "JVNVU93250330", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU98271228", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-24-165-10", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-23-348-08", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-019860", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-97273", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97273" }, { "db": "JVNDB", "id": "JVNDB-2023-019860" }, { "db": "NVD", "id": "CVE-2023-38380" } ] }, "id": "VAR-202312-0253", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-97273" } ], "trust": 1.4210873 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97273" } ] }, "last_update_date": "2024-08-14T12:47:17.949000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens Industrial Products Web Server Denial of Service Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/500376" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97273" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-401", "trust": 1.0 }, { "problemtype": "Lack of memory release after expiration (CWE-401) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019860" }, { "db": "NVD", "id": "CVE-2023-38380" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf" }, { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-693975.html" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-625862.html" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu98271228/" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu93250330/index.html" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38380" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-08" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-10" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97273" }, { "db": "JVNDB", "id": "JVNDB-2023-019860" }, { "db": "NVD", "id": "CVE-2023-38380" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-97273" }, { "db": "JVNDB", "id": "JVNDB-2023-019860" }, { "db": "NVD", "id": "CVE-2023-38380" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-14T00:00:00", "db": "CNVD", "id": "CNVD-2023-97273" }, { "date": "2024-01-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-019860" }, { "date": "2023-12-12T12:15:11.477000", "db": "NVD", "id": "CVE-2023-38380" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-13T00:00:00", "db": "CNVD", "id": "CNVD-2023-97273" }, { "date": "2024-06-17T06:15:00", "db": "JVNDB", "id": "JVNDB-2023-019860" }, { "date": "2024-06-11T12:15:10.630000", "db": "NVD", "id": "CVE-2023-38380" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Lack of Freeing Memory After Expiration Vulnerability in Multiple Siemens Products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019860" } ], "trust": 0.8 } }