All the vulnerabilites related to Siemens - SCALANCE XC206-2SFP EEC
cve-2019-6569
Vulnerability from cvelistv5
Published
2019-03-26 21:12
Modified
2024-08-04 20:23
Severity ?
Summary
The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.
Impacted products
Vendor Product Version
Siemens SCALANCE X204-2FM Version: All versions < V5.2.6
Siemens SCALANCE X204-2LD Version: All versions < V5.2.6
Siemens SCALANCE X204-2LD TS Version: All versions < V5.2.6
Siemens SCALANCE X204-2TS Version: All versions < V5.2.6
Siemens SCALANCE X206-1 Version: All versions < V5.2.6
Siemens SCALANCE X206-1LD Version: All versions < V5.2.6
Siemens SCALANCE X208 Version: All versions < V5.2.6
Siemens SCALANCE X208PRO Version: All versions < V5.2.6
Siemens SCALANCE X212-2 Version: All versions < V5.2.6
Siemens SCALANCE X212-2LD Version: All versions < V5.2.6
Siemens SCALANCE X216 Version: All versions < V5.2.6
Siemens SCALANCE X224 Version: All versions < V5.2.6
Siemens SCALANCE X302-7 EEC (230V) Version: All versions < V4.1.3
Siemens SCALANCE X302-7 EEC (230V, coated) Version: All versions < V4.1.3
Siemens SCALANCE X302-7 EEC (24V) Version: All versions < V4.1.3
Siemens SCALANCE X302-7 EEC (24V, coated) Version: All versions < V4.1.3
Siemens SCALANCE X302-7 EEC (2x 230V) Version: All versions < V4.1.3
Siemens SCALANCE X302-7 EEC (2x 230V, coated) Version: All versions < V4.1.3
Siemens SCALANCE X302-7 EEC (2x 24V) Version: All versions < V4.1.3
Siemens SCALANCE X302-7 EEC (2x 24V, coated) Version: All versions < V4.1.3
Siemens SCALANCE X304-2FE Version: All versions < V4.1.3
Siemens SCALANCE X306-1LD FE Version: All versions < V4.1.3
Siemens SCALANCE X307-2 EEC (230V) Version: All versions < V4.1.3
Siemens SCALANCE X307-2 EEC (230V, coated) Version: All versions < V4.1.3
Siemens SCALANCE X307-2 EEC (24V) Version: All versions < V4.1.3
Siemens SCALANCE X307-2 EEC (24V, coated) Version: All versions < V4.1.3
Siemens SCALANCE X307-2 EEC (2x 230V) Version: All versions < V4.1.3
Siemens SCALANCE X307-2 EEC (2x 230V, coated) Version: All versions < V4.1.3
Siemens SCALANCE X307-2 EEC (2x 24V) Version: All versions < V4.1.3
Siemens SCALANCE X307-2 EEC (2x 24V, coated) Version: All versions < V4.1.3
Siemens SCALANCE X307-3 Version: All versions < V4.1.3
Siemens SCALANCE X307-3 Version: All versions < V4.1.3
Siemens SCALANCE X307-3LD Version: All versions < V4.1.3
Siemens SCALANCE X307-3LD Version: All versions < V4.1.3
Siemens SCALANCE X308-2 Version: All versions < V4.1.3
Siemens SCALANCE X308-2 Version: All versions < V4.1.3
Siemens SCALANCE X308-2LD Version: All versions < V4.1.3
Siemens SCALANCE X308-2LD Version: All versions < V4.1.3
Siemens SCALANCE X308-2LH Version: All versions < V4.1.3
Siemens SCALANCE X308-2LH Version: All versions < V4.1.3
Siemens SCALANCE X308-2LH+ Version: All versions < V4.1.3
Siemens SCALANCE X308-2LH+ Version: All versions < V4.1.3
Siemens SCALANCE X308-2M Version: All versions < V4.1.3
Siemens SCALANCE X308-2M Version: All versions < V4.1.3
Siemens SCALANCE X308-2M PoE Version: All versions < V4.1.3
Siemens SCALANCE X308-2M PoE Version: All versions < V4.1.3
Siemens SCALANCE X308-2M TS Version: All versions < V4.1.3
Siemens SCALANCE X308-2M TS Version: All versions < V4.1.3
Siemens SCALANCE X310 Version: All versions < V4.1.3
Siemens SCALANCE X310 Version: All versions < V4.1.3
Siemens SCALANCE X310FE Version: All versions < V4.1.3
Siemens SCALANCE X310FE Version: All versions < V4.1.3
Siemens SCALANCE X320-1 FE Version: All versions < V4.1.3
Siemens SCALANCE X320-1-2LD FE Version: All versions < V4.1.3
Siemens SCALANCE X408-2 Version: All versions < V4.1.3
Siemens SCALANCE XB205-3 (SC) Version: All versions < V4.1
Siemens SCALANCE XB205-3 (SC) Version: All versions < V4.1
Siemens SCALANCE XB205-3 (ST/BFOC) Version: All versions < V4.1
Siemens SCALANCE XB205-3 (ST/BFOC) Version: All versions < V4.1
Siemens SCALANCE XB205-3LD Version: All versions < V4.1
Siemens SCALANCE XB205-3LD Version: All versions < V4.1
Siemens SCALANCE XB208 Version: All versions < V4.1
Siemens SCALANCE XB208 Version: All versions < V4.1
Siemens SCALANCE XB213-3 (SC) Version: All versions < V4.1
Siemens SCALANCE XB213-3 (SC) Version: All versions < V4.1
Siemens SCALANCE XB213-3 (ST/BFOC) Version: All versions < V4.1
Siemens SCALANCE XB213-3 (ST/BFOC) Version: All versions < V4.1
Siemens SCALANCE XB213-3LD Version: All versions < V4.1
Siemens SCALANCE XB213-3LD Version: All versions < V4.1
Siemens SCALANCE XB216 Version: All versions < V4.1
Siemens SCALANCE XB216 Version: All versions < V4.1
Siemens SCALANCE XC206-2 (SC) Version: All versions < V4.1
Siemens SCALANCE XC206-2 (ST/BFOC) Version: All versions < V4.1
Siemens SCALANCE XC206-2SFP Version: All versions < V4.1
Siemens SCALANCE XC206-2SFP EEC Version: All versions < V4.1
Siemens SCALANCE XC206-2SFP G Version: All versions < V4.1
Siemens SCALANCE XC206-2SFP G Version: All versions < V4.1
Siemens SCALANCE XC206-2SFP G EEC Version: All versions < V4.1
Siemens SCALANCE XC208 Version: All versions < V4.1
Siemens SCALANCE XC208EEC Version: All versions < V4.1
Siemens SCALANCE XC208G Version: All versions < V4.1
Siemens SCALANCE XC208G Version: All versions < V4.1
Siemens SCALANCE XC208G EEC Version: All versions < V4.1
Siemens SCALANCE XC216 Version: All versions < V4.1
Siemens SCALANCE XC216-4C Version: All versions < V4.1
Siemens SCALANCE XC216-4C G Version: All versions < V4.1
Siemens SCALANCE XC216-4C G (EIP Def.) Version: All versions < V4.1
Siemens SCALANCE XC216-4C G EEC Version: All versions < V4.1
Siemens SCALANCE XC216EEC Version: All versions < V4.1
Siemens SCALANCE XC224 Version: All versions < V4.1
Siemens SCALANCE XC224-4C G Version: All versions < V4.1
Siemens SCALANCE XC224-4C G (EIP Def.) Version: All versions < V4.1
Siemens SCALANCE XC224-4C G EEC Version: All versions < V4.1
Siemens SCALANCE XF204 Version: All versions < V5.2.6
Siemens SCALANCE XF204 Version: All versions < V4.1
Siemens SCALANCE XF204 DNA Version: All versions < V4.1
Siemens SCALANCE XF204-2 Version: All versions < V5.2.6
Siemens SCALANCE XF204-2BA Version: All versions < V4.1
Siemens SCALANCE XF204-2BA DNA Version: All versions < V4.1
Siemens SCALANCE XF206-1 Version: All versions < V5.2.6
Siemens SCALANCE XF208 Version: All versions < V5.2.6
Siemens SCALANCE XP208 Version: All versions < V4.1
Siemens SCALANCE XP208 Version: All versions < V4.1
Siemens SCALANCE XP208EEC Version: All versions < V4.1
Siemens SCALANCE XP208PoE EEC Version: All versions < V4.1
Siemens SCALANCE XP216 Version: All versions < V4.1
Siemens SCALANCE XP216 Version: All versions < V4.1
Siemens SCALANCE XP216EEC Version: All versions < V4.1
Siemens SCALANCE XP216POE EEC Version: All versions < V4.1
Siemens SCALANCE XR324-12M (230V, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-12M (230V, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-12M (230V, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-12M (230V, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-12M (24V, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-12M (24V, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-12M (24V, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-12M (24V, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-12M TS (24V) Version: All versions < V4.1.3
Siemens SCALANCE XR324-12M TS (24V) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (24V, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (24V, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (24V, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (24V, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M PoE (230V, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M PoE (230V, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M PoE (230V, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M PoE (230V, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M PoE (24V, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M PoE (24V, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M PoE (24V, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M PoE (24V, ports on rear) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M PoE TS (24V, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324-4M PoE TS (24V, ports on front) Version: All versions < V4.1.3
Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: All versions < V4.1
Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: All versions < V4.1
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: All versions < V4.1
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: All versions < V4.1
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.1
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.1
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: All versions < V4.1
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: All versions < V4.1
Siemens SIPLUS NET SCALANCE X308-2 Version: All versions < V4.1.3
Siemens SIPLUS NET SCALANCE XC206-2 Version: All versions < V4.1
Siemens SIPLUS NET SCALANCE XC206-2SFP Version: All versions < V4.1
Siemens SIPLUS NET SCALANCE XC208 Version: All versions < V4.1
Siemens SIPLUS NET SCALANCE XC216-4C Version: All versions < V4.1
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:22.201Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X204-2FM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X204-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X204-2LD TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X204-2TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X206-1LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X208PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X212-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X212-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XB205-3 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB205-3 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB205-3 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB205-3 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB205-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB205-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB213-3 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB213-3 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB213-3 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB213-3 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB213-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB213-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XF204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XF206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE XF208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        }
      ],
      "datePublic": "2019-03-12T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-440",
              "description": "CWE-440: Expected Behavior Violation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-12T10:06:21",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-6569",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE X204-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X204-2FM",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X204-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X204-2LD TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X204-2TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X206-1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X206-1LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X208PRO",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X212-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X212-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X216",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X224",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X304-2FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X306-1LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1 FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1-2LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X408-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB205-3 (SC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB205-3 (SC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB205-3 (ST/BFOC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB205-3 (ST/BFOC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB205-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB205-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB213-3 (SC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB213-3 (SC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB213-3 (ST/BFOC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB213-3 (ST/BFOC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB213-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB213-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB216",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB216",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC206-2 (SC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC206-2 (ST/BFOC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC206-2SFP",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC206-2SFP EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC206-2SFP G",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC206-2SFP G",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC206-2SFP G EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC208EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC208G",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC208G",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC208G EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC216",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC216-4C",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC216-4C G",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC216-4C G (EIP Def.)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC216-4C G EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC216EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC224",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC224-4C G",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC224-4C G (EIP Def.)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC224-4C G EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF204",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF204",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF204 DNA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF204-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF204-2BA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF204-2BA DNA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF206-1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP208EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP208PoE EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP216",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP216",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP216EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP216POE EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324WG (24 X FE, DC 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324WG (24 x FE, AC 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE XC206-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE XC206-2SFP",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE XC208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE XC216-4C",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-440: Expected Behavior Violation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-6569",
    "datePublished": "2019-03-26T21:12:43",
    "dateReserved": "2019-01-22T00:00:00",
    "dateUpdated": "2024-08-04T20:23:22.201Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-46143
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2024-08-13 07:50
Summary
Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) EU Version: 0   < V8.0
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: 0   < V7.2
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: 0   < V8.0
Siemens SCALANCE M804PB Version: 0   < V7.2
Siemens SCALANCE M804PB Version: 0   < V8.0
Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V7.2
Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V8.0
Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V7.2
Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V8.0
Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V7.2
Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V8.0
Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V7.2
Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V8.0
Siemens SCALANCE M826-2 SHDSL-Router Version: 0   < V7.2
Siemens SCALANCE M826-2 SHDSL-Router Version: 0   < V8.0
Siemens SCALANCE M874-2 Version: 0   < V7.2
Siemens SCALANCE M874-2 Version: 0   < V8.0
Siemens SCALANCE M874-3 Version: 0   < V7.2
Siemens SCALANCE M874-3 Version: 0   < V8.0
Siemens SCALANCE M876-3 Version: 0   < V7.2
Siemens SCALANCE M876-3 Version: 0   < V8.0
Siemens SCALANCE M876-3 (ROK) Version: 0   < V7.2
Siemens SCALANCE M876-3 (ROK) Version: 0   < V8.0
Siemens SCALANCE M876-4 Version: 0   < V7.2
Siemens SCALANCE M876-4 Version: 0   < V8.0
Siemens SCALANCE M876-4 (EU) Version: 0   < V7.2
Siemens SCALANCE M876-4 (EU) Version: 0   < V8.0
Siemens SCALANCE M876-4 (NAM) Version: 0   < V7.2
Siemens SCALANCE M876-4 (NAM) Version: 0   < V8.0
Siemens SCALANCE MUM853-1 (EU) Version: 0   < V7.2
Siemens SCALANCE MUM853-1 (EU) Version: 0   < V8.0
Siemens SCALANCE MUM856-1 (EU) Version: 0   < V7.2
Siemens SCALANCE MUM856-1 (EU) Version: 0   < V8.0
Siemens SCALANCE MUM856-1 (RoW) Version: 0   < V7.2
Siemens SCALANCE MUM856-1 (RoW) Version: 0   < V8.0
Siemens SCALANCE S615 EEC LAN-Router Version: 0   < V7.2
Siemens SCALANCE S615 EEC LAN-Router Version: 0   < V8.0
Siemens SCALANCE S615 LAN-Router Version: 0   < V7.2
Siemens SCALANCE S615 LAN-Router Version: 0   < V8.0
Siemens SCALANCE SC622-2C Version: 0   < V2.3
Siemens SCALANCE SC622-2C Version: V2.3   < V3.0
Siemens SCALANCE SC626-2C Version: 0   < V2.3
Siemens SCALANCE SC626-2C Version: V2.3   < V3.0
Siemens SCALANCE SC632-2C Version: 0   < V2.3
Siemens SCALANCE SC632-2C Version: V2.3   < V3.0
Siemens SCALANCE SC636-2C Version: 0   < V2.3
Siemens SCALANCE SC636-2C Version: V2.3   < V3.0
Siemens SCALANCE SC642-2C Version: 0   < V2.3
Siemens SCALANCE SC642-2C Version: V2.3   < V3.0
Siemens SCALANCE SC646-2C Version: 0   < V2.3
Siemens SCALANCE SC646-2C Version: V2.3   < V3.0
Siemens SCALANCE W1748-1 M12 Version: 0   < *
Siemens SCALANCE W1748-1 M12 Version: 0   < *
Siemens SCALANCE W1788-1 M12 Version: 0   < *
Siemens SCALANCE W1788-2 EEC M12 Version: 0   < *
Siemens SCALANCE W1788-2 M12 Version: 0   < *
Siemens SCALANCE W1788-2IA M12 Version: 0   < *
Siemens SCALANCE W721-1 RJ45 Version: 0   < *
Siemens SCALANCE W721-1 RJ45 Version: 0   < *
Siemens SCALANCE W722-1 RJ45 Version: 0   < *
Siemens SCALANCE W722-1 RJ45 Version: 0   < *
Siemens SCALANCE W722-1 RJ45 Version: 0   < *
Siemens SCALANCE W734-1 RJ45 Version: 0   < *
Siemens SCALANCE W734-1 RJ45 Version: 0   < *
Siemens SCALANCE W734-1 RJ45 Version: 0   < *
Siemens SCALANCE W734-1 RJ45 (USA) Version: 0   < *
Siemens SCALANCE W738-1 M12 Version: 0   < *
Siemens SCALANCE W738-1 M12 Version: 0   < *
Siemens SCALANCE W748-1 M12 Version: 0   < *
Siemens SCALANCE W748-1 M12 Version: 0   < *
Siemens SCALANCE W748-1 RJ45 Version: 0   < *
Siemens SCALANCE W748-1 RJ45 Version: 0   < *
Siemens SCALANCE W761-1 RJ45 Version: 0   < *
Siemens SCALANCE W761-1 RJ45 Version: 0   < *
Siemens SCALANCE W774-1 M12 EEC Version: 0   < *
Siemens SCALANCE W774-1 M12 EEC Version: 0   < *
Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Siemens SCALANCE W774-1 RJ45 (USA) Version: 0   < *
Siemens SCALANCE W778-1 M12 Version: 0   < *
Siemens SCALANCE W778-1 M12 Version: 0   < *
Siemens SCALANCE W778-1 M12 EEC Version: 0   < *
Siemens SCALANCE W778-1 M12 EEC (USA) Version: 0   < *
Siemens SCALANCE W786-1 RJ45 Version: 0   < *
Siemens SCALANCE W786-1 RJ45 Version: 0   < *
Siemens SCALANCE W786-2 RJ45 Version: 0   < *
Siemens SCALANCE W786-2 RJ45 Version: 0   < *
Siemens SCALANCE W786-2 RJ45 Version: 0   < *
Siemens SCALANCE W786-2 SFP Version: 0   < *
Siemens SCALANCE W786-2 SFP Version: 0   < *
Siemens SCALANCE W786-2IA RJ45 Version: 0   < *
Siemens SCALANCE W786-2IA RJ45 Version: 0   < *
Siemens SCALANCE W788-1 M12 Version: 0   < *
Siemens SCALANCE W788-1 M12 Version: 0   < *
Siemens SCALANCE W788-1 RJ45 Version: 0   < *
Siemens SCALANCE W788-1 RJ45 Version: 0   < *
Siemens SCALANCE W788-2 M12 Version: 0   < *
Siemens SCALANCE W788-2 M12 Version: 0   < *
Siemens SCALANCE W788-2 M12 EEC Version: 0   < *
Siemens SCALANCE W788-2 M12 EEC Version: 0   < *
Siemens SCALANCE W788-2 M12 EEC Version: 0   < *
Siemens SCALANCE W788-2 RJ45 Version: 0   < *
Siemens SCALANCE W788-2 RJ45 Version: 0   < *
Siemens SCALANCE W788-2 RJ45 Version: 0   < *
Siemens SCALANCE WAM763-1 Version: 0   < V2.0
Siemens SCALANCE WAM766-1 (EU) Version: 0   < V2.0
Siemens SCALANCE WAM766-1 (US) Version: 0   < V2.0
Siemens SCALANCE WAM766-1 EEC (EU) Version: 0   < V2.0
Siemens SCALANCE WAM766-1 EEC (US) Version: 0   < V2.0
Siemens SCALANCE WUM763-1 Version: 0   < V2.0
Siemens SCALANCE WUM763-1 Version: 0   < V2.0
Siemens SCALANCE WUM766-1 (EU) Version: 0   < V2.0
Siemens SCALANCE WUM766-1 (US) Version: 0   < V2.0
Siemens SCALANCE XB205-3 (SC, PN) Version: 0   < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < V4.4
Siemens SCALANCE XB205-3 (ST, PN) Version: 0   < V4.4
Siemens SCALANCE XB205-3LD (SC, E/IP) Version: 0   < V4.4
Siemens SCALANCE XB205-3LD (SC, PN) Version: 0   < V4.4
Siemens SCALANCE XB208 (E/IP) Version: 0   < V4.4
Siemens SCALANCE XB208 (PN) Version: 0   < V4.4
Siemens SCALANCE XB213-3 (SC, E/IP) Version: 0   < V4.4
Siemens SCALANCE XB213-3 (SC, PN) Version: 0   < V4.4
Siemens SCALANCE XB213-3 (ST, E/IP) Version: 0   < V4.4
Siemens SCALANCE XB213-3 (ST, PN) Version: 0   < V4.4
Siemens SCALANCE XB213-3LD (SC, E/IP) Version: 0   < V4.4
Siemens SCALANCE XB213-3LD (SC, PN) Version: 0   < V4.4
Siemens SCALANCE XB216 (E/IP) Version: 0   < V4.4
Siemens SCALANCE XB216 (PN) Version: 0   < V4.4
Siemens SCALANCE XC206-2 (SC) Version: 0   < V4.4
Siemens SCALANCE XC206-2 (ST/BFOC) Version: 0   < V4.4
Siemens SCALANCE XC206-2G PoE Version: 0   < V4.4
Siemens SCALANCE XC206-2G PoE (54 V DC) Version: 0   < V4.4
Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: 0   < V4.4
Siemens SCALANCE XC206-2SFP Version: 0   < V4.4
Siemens SCALANCE XC206-2SFP EEC Version: 0   < V4.4
Siemens SCALANCE XC206-2SFP G Version: 0   < V4.4
Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: 0   < V4.4
Siemens SCALANCE XC206-2SFP G EEC Version: 0   < V4.4
Siemens SCALANCE XC208 Version: 0   < V4.4
Siemens SCALANCE XC208EEC Version: 0   < V4.4
Siemens SCALANCE XC208G Version: 0   < V4.4
Siemens SCALANCE XC208G (EIP def.) Version: 0   < V4.4
Siemens SCALANCE XC208G EEC Version: 0   < V4.4
Siemens SCALANCE XC208G PoE Version: 0   < V4.4
Siemens SCALANCE XC208G PoE (54 V DC) Version: 0   < V4.4
Siemens SCALANCE XC216 Version: 0   < V4.4
Siemens SCALANCE XC216-3G PoE Version: 0   < V4.4
Siemens SCALANCE XC216-3G PoE (54 V DC) Version: 0   < V4.4
Siemens SCALANCE XC216-4C Version: 0   < V4.4
Siemens SCALANCE XC216-4C G Version: 0   < V4.4
Siemens SCALANCE XC216-4C G (EIP Def.) Version: 0   < V4.4
Siemens SCALANCE XC216-4C G EEC Version: 0   < V4.4
Siemens SCALANCE XC216EEC Version: 0   < V4.4
Siemens SCALANCE XC224 Version: 0   < V4.4
Siemens SCALANCE XC224-4C G Version: 0   < V4.4
Siemens SCALANCE XC224-4C G (EIP Def.) Version: 0   < V4.4
Siemens SCALANCE XC224-4C G EEC Version: 0   < V4.4
Siemens SCALANCE XF204 Version: 0   < V4.4
Siemens SCALANCE XF204 DNA Version: 0   < V4.4
Siemens SCALANCE XF204-2BA Version: 0   < V4.4
Siemens SCALANCE XF204-2BA DNA Version: 0   < V4.4
Siemens SCALANCE XM408-4C Version: 0   < V6.6
Siemens SCALANCE XM408-4C (L3 int.) Version: 0   < V6.6
Siemens SCALANCE XM408-8C Version: 0   < V6.6
Siemens SCALANCE XM408-8C (L3 int.) Version: 0   < V6.6
Siemens SCALANCE XM416-4C Version: 0   < V6.6
Siemens SCALANCE XM416-4C (L3 int.) Version: 0   < V6.6
Siemens SCALANCE XP208 Version: 0   < V4.4
Siemens SCALANCE XP208 (Ethernet/IP) Version: 0   < V4.4
Siemens SCALANCE XP208EEC Version: 0   < V4.4
Siemens SCALANCE XP208PoE EEC Version: 0   < V4.4
Siemens SCALANCE XP216 Version: 0   < V4.4
Siemens SCALANCE XP216 (Ethernet/IP) Version: 0   < V4.4
Siemens SCALANCE XP216EEC Version: 0   < V4.4
Siemens SCALANCE XP216POE EEC Version: 0   < V4.4
Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: 0   < V4.4
Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: 0   < V4.4
Siemens SCALANCE XR326-2C PoE WG Version: 0   < V4.4
Siemens SCALANCE XR326-2C PoE WG (without UL) Version: 0   < V4.4
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: 0   < V4.4
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: 0   < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: 0   < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: 0   < V4.4
Siemens SCALANCE XR524-8C, 1x230V Version: 0   < V6.6
Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: 0   < V6.6
Siemens SCALANCE XR524-8C, 24V Version: 0   < V6.6
Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: 0   < V6.6
Siemens SCALANCE XR524-8C, 2x230V Version: 0   < V6.6
Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: 0   < V6.6
Siemens SCALANCE XR526-8C, 1x230V Version: 0   < V6.6
Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: 0   < V6.6
Siemens SCALANCE XR526-8C, 24V Version: 0   < V6.6
Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: 0   < V6.6
Siemens SCALANCE XR526-8C, 2x230V Version: 0   < V6.6
Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: 0   < V6.6
Siemens SCALANCE XR528-6M Version: 0   < V6.6
Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: 0   < V6.6
Siemens SCALANCE XR528-6M (2HR2) Version: 0   < V6.6
Siemens SCALANCE XR528-6M (L3 int.) Version: 0   < V6.6
Siemens SCALANCE XR552-12M Version: 0   < V6.6
Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: 0   < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: 0   < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: 0   < V6.6
Siemens SIPLUS NET SCALANCE XC206-2 Version: 0   < V4.4
Siemens SIPLUS NET SCALANCE XC206-2SFP Version: 0   < V4.4
Siemens SIPLUS NET SCALANCE XC208 Version: 0   < V4.4
Siemens SIPLUS NET SCALANCE XC216-4C Version: 0   < V4.4
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:24:03.372Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 2.7,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1284",
              "description": "CWE-1284: Improper Validation of Specified Quantity in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:50:25.824Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-46143",
    "datePublished": "2022-12-13T00:00:00",
    "dateReserved": "2022-11-28T00:00:00",
    "dateUpdated": "2024-08-13T07:50:25.824Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-28400
Vulnerability from cvelistv5
Published
2021-07-13 11:02
Modified
2024-12-10 13:53
Summary
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
Impacted products
Vendor Product Version
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 Version: All versions
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P Version: All versions < V4.7
Siemens RUGGEDCOM RM1224 LTE(4G) EU Version: 0   < V6.4
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: 0   < V6.4
Siemens SCALANCE M804PB Version: 0   < V6.4
Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V6.4
Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V6.4
Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V6.4
Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V6.4
Siemens SCALANCE M826-2 SHDSL-Router Version: 0   < V6.4
Siemens SCALANCE M874-2 Version: 0   < V6.4
Siemens SCALANCE M874-3 Version: 0   < V6.4
Siemens SCALANCE M874-3 3G-Router (CN) Version: 0   < V6.4
Siemens SCALANCE M876-3 Version: 0   < V6.4
Siemens SCALANCE M876-3 (ROK) Version: 0   < V6.4
Siemens SCALANCE M876-4 Version: 0   < V6.4
Siemens SCALANCE M876-4 (EU) Version: 0   < V6.4
Siemens SCALANCE M876-4 (NAM) Version: 0   < V6.4
Siemens SCALANCE MUM853-1 (A1) Version: 0   < V6.4
Siemens SCALANCE MUM853-1 (B1) Version: 0   < V6.4
Siemens SCALANCE MUM853-1 (EU) Version: 0   < V6.4
Siemens SCALANCE MUM856-1 (A1) Version: 0   < V6.4
Siemens SCALANCE MUM856-1 (B1) Version: 0   < V6.4
Siemens SCALANCE MUM856-1 (CN) Version: 0   < V6.4
Siemens SCALANCE MUM856-1 (EU) Version: 0   < V6.4
Siemens SCALANCE MUM856-1 (RoW) Version: 0   < V6.4
Siemens SCALANCE S615 EEC LAN-Router Version: 0   < V6.4
Siemens SCALANCE S615 LAN-Router Version: 0   < V6.4
Siemens SCALANCE W1748-1 M12 Version: All versions < V3.0.0
Siemens SCALANCE W1748-1 M12 Version: All versions < V3.0.0
Siemens SCALANCE W1788-1 M12 Version: All versions < V3.0.0
Siemens SCALANCE W1788-2 EEC M12 Version: All versions < V3.0.0
Siemens SCALANCE W1788-2 M12 Version: All versions < V3.0.0
Siemens SCALANCE W1788-2IA M12 Version: All versions < V3.0.0
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 EEC Version: All versions
Siemens SCALANCE W778-1 M12 EEC (USA) Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE X200-4P IRT Version: All Versions < V5.5.0
Siemens SCALANCE X201-3P IRT Version: All Versions < V5.5.0
Siemens SCALANCE X201-3P IRT PRO Version: All Versions < V5.5.0
Siemens SCALANCE X202-2IRT Version: All Versions < V5.5.0
Siemens SCALANCE X202-2P IRT Version: All Versions < V5.5.0
Siemens SCALANCE X202-2P IRT PRO Version: All Versions < V5.5.0
Siemens SCALANCE X204-2 Version: 0   < V5.2.5
Siemens SCALANCE X204-2FM Version: 0   < V5.2.5
Siemens SCALANCE X204-2LD Version: 0   < V5.2.5
Siemens SCALANCE X204-2LD TS Version: 0   < V5.2.5
Siemens SCALANCE X204-2TS Version: 0   < V5.2.5
Siemens SCALANCE X204IRT Version: All Versions < V5.5.0
Siemens SCALANCE X204IRT PRO Version: All Versions < V5.5.0
Siemens SCALANCE X206-1 Version: 0   < V5.2.5
Siemens SCALANCE X206-1LD Version: 0   < V5.2.5
Siemens SCALANCE X208 Version: 0   < V5.2.5
Siemens SCALANCE X208PRO Version: 0   < V5.2.5
Siemens SCALANCE X212-2 Version: 0   < V5.2.5
Siemens SCALANCE X212-2LD Version: 0   < V5.2.5
Siemens SCALANCE X216 Version: 0   < V5.2.5
Siemens SCALANCE X224 Version: 0   < V5.2.5
Siemens SCALANCE X302-7 EEC (230V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X302-7 EEC (230V) Version: 0   < V4.1.4
Siemens SCALANCE X302-7 EEC (24V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X302-7 EEC (24V) Version: 0   < V4.1.4
Siemens SCALANCE X302-7 EEC (2x 230V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X302-7 EEC (2x 230V) Version: 0   < V4.1.4
Siemens SCALANCE X302-7 EEC (2x 24V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X302-7 EEC (2x 24V) Version: 0   < V4.1.4
Siemens SCALANCE X304-2FE Version: 0   < V4.1.4
Siemens SCALANCE X306-1LD FE Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (230V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (230V) Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (24V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (24V) Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (2x 230V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (2x 230V) Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (2x 24V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (2x 24V) Version: 0   < V4.1.4
Siemens SCALANCE X307-3 Version: 0   < V4.1.4
Siemens SCALANCE X307-3 Version: 0   < V4.1.4
Siemens SCALANCE X307-3LD Version: 0   < V4.1.4
Siemens SCALANCE X307-3LD Version: 0   < V4.1.4
Siemens SCALANCE X308-2 Version: 0   < V4.1.4
Siemens SCALANCE X308-2 Version: 0   < V4.1.4
Siemens SCALANCE X308-2LD Version: 0   < V4.1.4
Siemens SCALANCE X308-2LD Version: 0   < V4.1.4
Siemens SCALANCE X308-2LH Version: 0   < V4.1.4
Siemens SCALANCE X308-2LH Version: 0   < V4.1.4
Siemens SCALANCE X308-2LH+ Version: 0   < V4.1.4
Siemens SCALANCE X308-2LH+ Version: 0   < V4.1.4
Siemens SCALANCE X308-2M Version: 0   < V4.1.4
Siemens SCALANCE X308-2M Version: 0   < V4.1.4
Siemens SCALANCE X308-2M PoE Version: 0   < V4.1.4
Siemens SCALANCE X308-2M PoE Version: 0   < V4.1.4
Siemens SCALANCE X308-2M TS Version: 0   < V4.1.4
Siemens SCALANCE X308-2M TS Version: 0   < V4.1.4
Siemens SCALANCE X310 Version: 0   < V4.1.4
Siemens SCALANCE X310 Version: 0   < V4.1.4
Siemens SCALANCE X310FE Version: 0   < V4.1.4
Siemens SCALANCE X310FE Version: 0   < V4.1.4
Siemens SCALANCE X320-1 FE Version: 0   < V4.1.4
Siemens SCALANCE X320-1-2LD FE Version: 0   < V4.1.4
Siemens SCALANCE X408-2 Version: 0   < V4.1.4
Siemens SCALANCE XB205-3 (SC, PN) Version: 0   < V4.3
Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < V4.3
Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < V4.3
Siemens SCALANCE XB205-3 (ST, PN) Version: 0   < V4.3
Siemens SCALANCE XB205-3LD (SC, E/IP) Version: 0   < V4.3
Siemens SCALANCE XB205-3LD (SC, PN) Version: 0   < V4.3
Siemens SCALANCE XB208 (E/IP) Version: 0   < V4.3
Siemens SCALANCE XB208 (PN) Version: 0   < V4.3
Siemens SCALANCE XB213-3 (SC, E/IP) Version: 0   < V4.3
Siemens SCALANCE XB213-3 (SC, PN) Version: 0   < V4.3
Siemens SCALANCE XB213-3 (ST, E/IP) Version: 0   < V4.3
Siemens SCALANCE XB213-3 (ST, PN) Version: 0   < V4.3
Siemens SCALANCE XB213-3LD (SC, E/IP) Version: 0   < V4.3
Siemens SCALANCE XB213-3LD (SC, PN) Version: 0   < V4.3
Siemens SCALANCE XB216 (E/IP) Version: 0   < V4.3
Siemens SCALANCE XB216 (PN) Version: 0   < V4.3
Siemens SCALANCE XC206-2 (SC) Version: 0   < V4.3
Siemens SCALANCE XC206-2 (ST/BFOC) Version: 0   < V4.3
Siemens SCALANCE XC206-2G PoE Version: 0   < V4.3
Siemens SCALANCE XC206-2G PoE (54 V DC) Version: 0   < V4.3
Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: 0   < V4.3
Siemens SCALANCE XC206-2SFP Version: 0   < V4.3
Siemens SCALANCE XC206-2SFP EEC Version: 0   < V4.3
Siemens SCALANCE XC206-2SFP G Version: 0   < V4.3
Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: 0   < V4.3
Siemens SCALANCE XC206-2SFP G EEC Version: 0   < V4.3
Siemens SCALANCE XC208 Version: 0   < V4.3
Siemens SCALANCE XC208EEC Version: 0   < V4.3
Siemens SCALANCE XC208G Version: 0   < V4.3
Siemens SCALANCE XC208G (EIP def.) Version: 0   < V4.3
Siemens SCALANCE XC208G EEC Version: 0   < V4.3
Siemens SCALANCE XC208G PoE Version: 0   < V4.3
Siemens SCALANCE XC208G PoE (54 V DC) Version: 0   < V4.3
Siemens SCALANCE XC216 Version: 0   < V4.3
Siemens SCALANCE XC216-3G PoE Version: 0   < V4.3
Siemens SCALANCE XC216-3G PoE (54 V DC) Version: 0   < V4.3
Siemens SCALANCE XC216-4C Version: 0   < V4.3
Siemens SCALANCE XC216-4C G Version: 0   < V4.3
Siemens SCALANCE XC216-4C G (EIP Def.) Version: 0   < V4.3
Siemens SCALANCE XC216-4C G EEC Version: 0   < V4.3
Siemens SCALANCE XC216EEC Version: 0   < V4.3
Siemens SCALANCE XC224 Version: 0   < V4.3
Siemens SCALANCE XC224-4C G Version: 0   < V4.3
Siemens SCALANCE XC224-4C G (EIP Def.) Version: 0   < V4.3
Siemens SCALANCE XC224-4C G EEC Version: 0   < V4.3
Siemens SCALANCE XF201-3P IRT Version: All Versions < V5.5.0
Siemens SCALANCE XF202-2P IRT Version: All Versions < V5.5.0
Siemens SCALANCE XF204 Version: 0   < V5.2.5
Siemens SCALANCE XF204 Version: 0   < V4.3
Siemens SCALANCE XF204 DNA Version: 0   < V4.3
Siemens SCALANCE XF204-2 Version: 0   < V5.2.5
Siemens SCALANCE XF204-2BA Version: 0   < V4.3
Siemens SCALANCE XF204-2BA DNA Version: 0   < V4.3
Siemens SCALANCE XF204-2BA IRT Version: All Versions < V5.5.0
Siemens SCALANCE XF204IRT Version: All Versions < V5.5.0
Siemens SCALANCE XF206-1 Version: 0   < V5.2.5
Siemens SCALANCE XF208 Version: 0   < V5.2.5
Siemens SCALANCE XM408-4C Version: 0   < V6.3.1
Siemens SCALANCE XM408-4C (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XM408-8C Version: 0   < V6.3.1
Siemens SCALANCE XM408-8C (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XM416-4C Version: 0   < V6.3.1
Siemens SCALANCE XM416-4C (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XP208 Version: 0   < V4.3
Siemens SCALANCE XP208 (Ethernet/IP) Version: 0   < V4.3
Siemens SCALANCE XP208EEC Version: 0   < V4.3
Siemens SCALANCE XP208PoE EEC Version: 0   < V4.3
Siemens SCALANCE XP216 Version: 0   < V4.3
Siemens SCALANCE XP216 (Ethernet/IP) Version: 0   < V4.3
Siemens SCALANCE XP216EEC Version: 0   < V4.3
Siemens SCALANCE XP216POE EEC Version: 0   < V4.3
Siemens SCALANCE XR324-12M (230V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M (230V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M (230V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M (230V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M (24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M (24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M (24V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M (24V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M TS (24V) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M TS (24V) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (24V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (24V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M PoE (230V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M PoE (230V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M PoE (24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M PoE (24V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M PoE TS (24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: 0   < V4.3
Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: 0   < V4.3
Siemens SCALANCE XR326-2C PoE WG Version: 0   < V4.3
Siemens SCALANCE XR326-2C PoE WG (without UL) Version: 0   < V4.3
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: 0   < V4.3
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: 0   < V4.3
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < V4.3
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < V4.3
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: 0   < V4.3
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: 0   < V4.3
Siemens SCALANCE XR524-8C, 1x230V Version: 0   < V6.3.1
Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR524-8C, 24V Version: 0   < V6.3.1
Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR524-8C, 2x230V Version: 0   < V6.3.1
Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR526-8C, 1x230V Version: 0   < V6.3.1
Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR526-8C, 24V Version: 0   < V6.3.1
Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR526-8C, 2x230V Version: 0   < V6.3.1
Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR528-6M Version: 0   < V6.3.1
Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR528-6M (2HR2) Version: 0   < V6.3.1
Siemens SCALANCE XR528-6M (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR552-12M Version: 0   < V6.3.1
Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR552-12M (2HR2) Version: 0   < V6.3.1
Siemens SCALANCE XR552-12M (2HR2) Version: 0   < V6.3.1
Siemens SIMATIC CFU DIQ Version: 0   < V2.0.0
Siemens SIMATIC CFU PA Version: 0   < V2.0.0
Siemens SIMATIC CM 1542-1 Version: All versions < V3.0
Siemens SIMATIC CP 1604 Version: All Versions >= V2.7
Siemens SIMATIC CP 1616 Version: All Versions >= V2.7
Siemens SIMATIC CP 1626 Version: All versions
Siemens SIMATIC IE/PB-LINK Version: V3   < *
Siemens SIMATIC MV540 H Version: All versions < V3.0
Siemens SIMATIC MV540 S Version: All versions < V3.0
Siemens SIMATIC MV550 H Version: All versions < V3.0
Siemens SIMATIC MV550 S Version: All versions < V3.0
Siemens SIMATIC MV560 U Version: All versions < V3.0
Siemens SIMATIC MV560 X Version: All versions < V3.0
Siemens SIMATIC NET DK-16xx PN IO Version: All Versions >= V2.7
Siemens SIMATIC Power Line Booster PLB, Base Module Version: All versions
Siemens SIMATIC PROFINET Driver Version: All versions < V2.3
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All Versions < V4.5
Siemens SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants) Version: All versions < V1.1.3
Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) Version: All versions < V2.1.3
Siemens SIPLUS NET SCALANCE X308-2 Version: 0   < V4.1.4
Siemens SIPLUS NET SCALANCE XC206-2 Version: 0   < V4.3
Siemens SIPLUS NET SCALANCE XC206-2SFP Version: 0   < V4.3
Siemens SIPLUS NET SCALANCE XC208 Version: 0   < V4.3
Siemens SIPLUS NET SCALANCE XC216-4C Version: 0   < V4.3
Siemens SOFTNET-IE PNIO Version: All versions
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m812-1_adsl-router_annex_b",
            "vendor": "seimens",
            "versions": [
              {
                "status": "affected",
                "version": "0"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200p:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200p",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.7",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:ruggedcom_rm1224:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ruggedcom_rm1224",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m804pb",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_a:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m812-1_adsl-router_annex_a",
            "vendor": "seimens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m812-1_adsl-router_annex_b",
            "vendor": "seimens",
            "versions": [
              {
                "lessThan": "6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m816_1_adsl_router_annex_a:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m816_1_adsl_router_annex_a",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m816-1_adsl-router_annex_b:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m816-1_adsl-router_annex_b",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m826-2_shdsl-router:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m826-2_shdsl-router",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_m874_2:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_m874_2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_m874_3:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_m874_3",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_3_evdo:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_3_evdo",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_3_rok:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_3_rok",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_4_eu:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_4_eu",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_4_nam:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_4_nam",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_s615",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w700_ieee_802.11n_family:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w700_ieee_802.11n_family",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1748_1_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1748_1_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_1_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_1_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_2_eec_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_2_eec_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_2_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_2_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_2ia_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_2ia_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_x200_4p_irt:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_x200_4p_irt",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_x201_3p_irt:0.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_x201_3p_irt",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_x201_3p_irt_pro:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_x201_3p_irt_pro",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalancce_x202_2p_irt:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalancce_x202_2p_irt",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_202_2p_irt_pro:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_202_2p_irt_pro",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalancce_x204_2:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalancce_x204_2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2fm:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2fm",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2ld:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2ld",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2ld_ts:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2ld_ts",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2ts:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2ts",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-28400",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-13T18:59:11.953107Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-24T18:07:44.485Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:59.218Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3 3G-Router (CN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (A1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (B1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (A1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (B1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (CN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X200-4P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2FM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD TS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2TS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X224",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CFU DIQ",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CFU PA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003e= V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003e= V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1626",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IE/PB-LINK",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV540 H",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV540 S",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV550 H",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV550 S",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV560 U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV560 X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET DK-16xx PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003e= V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Power Line Booster PLB, Base Module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PROFINET Driver",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V4.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SOFTNET-IE PNIO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-10T13:53:22.763Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28400",
    "datePublished": "2021-07-13T11:02:49",
    "dateReserved": "2020-11-10T00:00:00",
    "dateUpdated": "2024-12-10T13:53:22.763Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-31765
Vulnerability from cvelistv5
Published
2022-10-11 00:00
Modified
2024-08-03 07:26
Summary
Affected devices do not properly authorize the change password function of the web interface. This could allow low privileged users to escalate their privileges.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: All versions < V7.1.2
Siemens SCALANCE M804PB Version: All versions < V7.1.2
Siemens SCALANCE M812-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Siemens SCALANCE M812-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Siemens SCALANCE M816-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Siemens SCALANCE M816-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Siemens SCALANCE M826-2 SHDSL-Router Version: All versions < V7.1.2
Siemens SCALANCE M874-2 Version: All versions < V7.1.2
Siemens SCALANCE M874-3 Version: All versions < V7.1.2
Siemens SCALANCE M876-3 (EVDO) Version: All versions < V7.1.2
Siemens SCALANCE M876-3 (ROK) Version: All versions < V7.1.2
Siemens SCALANCE M876-4 Version: All versions < V7.1.2
Siemens SCALANCE M876-4 (EU) Version: All versions < V7.1.2
Siemens SCALANCE M876-4 (NAM) Version: All versions < V7.1.2
Siemens SCALANCE MUM853-1 (EU) Version: All versions < V7.1.2
Siemens SCALANCE MUM856-1 (EU) Version: All versions < V7.1.2
Siemens SCALANCE MUM856-1 (RoW) Version: All versions < V7.1.2
Siemens SCALANCE S615 Version: All versions < V7.1.2
Siemens SCALANCE S615 EEC Version: All versions < V7.1.2
Siemens SCALANCE SC622-2C Version: All versions < V3.0
Siemens SCALANCE SC632-2C Version: All versions < V3.0
Siemens SCALANCE SC636-2C Version: All versions < V3.0
Siemens SCALANCE SC642-2C Version: All versions < V3.0
Siemens SCALANCE SC646-2C Version: All versions < V3.0
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1788-1 M12 Version: All versions
Siemens SCALANCE W1788-2 EEC M12 Version: All versions
Siemens SCALANCE W1788-2 M12 Version: All versions
Siemens SCALANCE W1788-2IA M12 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 EEC Version: All versions
Siemens SCALANCE W778-1 M12 EEC (USA) Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE WAM763-1 Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (US) Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE XB205-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB208 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB208 (PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB216 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB216 (PN) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (SC) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (ST/BFOC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP EEC Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G EEC Version: All versions < V4.4
Siemens SCALANCE XC208 Version: All versions < V4.4
Siemens SCALANCE XC208EEC Version: All versions < V4.4
Siemens SCALANCE XC208G Version: All versions < V4.4
Siemens SCALANCE XC208G (EIP def.) Version: All versions < V4.4
Siemens SCALANCE XC208G EEC Version: All versions < V4.4
Siemens SCALANCE XC208G PoE Version: All versions < V4.4
Siemens SCALANCE XC208G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216 Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216-4C Version: All versions < V4.4
Siemens SCALANCE XC216-4C G Version: All versions < V4.4
Siemens SCALANCE XC216-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC216-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XC216EEC Version: All versions < V4.4
Siemens SCALANCE XC224 Version: All versions < V4.4
Siemens SCALANCE XC224-4C G Version: All versions < V4.4
Siemens SCALANCE XC224-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC224-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XF204 Version: All versions < V4.4
Siemens SCALANCE XF204 DNA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA DNA Version: All versions < V4.4
Siemens SCALANCE XM408-4C Version: All versions < V6.6
Siemens SCALANCE XM408-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM408-8C Version: All versions < V6.6
Siemens SCALANCE XM408-8C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM416-4C Version: All versions < V6.6
Siemens SCALANCE XM416-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XP208 Version: All versions < V4.4
Siemens SCALANCE XP208 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP208EEC Version: All versions < V4.4
Siemens SCALANCE XP208PoE EEC Version: All versions < V4.4
Siemens SCALANCE XP216 Version: All versions < V4.4
Siemens SCALANCE XP216 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP216EEC Version: All versions < V4.4
Siemens SCALANCE XP216POE EEC Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG (without UL) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR524-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SIPLUS NET SCALANCE XC206-2 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC208 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC216-4C Version: All versions < V4.4
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:26:01.033Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-552702.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (EVDO)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices do not properly authorize the change password function of the web interface.\r\nThis could allow low privileged users to escalate their privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-862",
              "description": "CWE-862: Missing Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:02:25.347Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-552702.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-31765",
    "datePublished": "2022-10-11T00:00:00",
    "dateReserved": "2022-05-27T00:00:00",
    "dateUpdated": "2024-08-03T07:26:01.033Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-36323
Vulnerability from cvelistv5
Published
2022-08-10 11:18
Modified
2024-08-03 10:00
Summary
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: All versions < V7.1.2
Siemens SCALANCE M804PB Version: All versions < V7.1.2
Siemens SCALANCE M812-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Siemens SCALANCE M812-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Siemens SCALANCE M816-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Siemens SCALANCE M816-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Siemens SCALANCE M826-2 SHDSL-Router Version: All versions < V7.1.2
Siemens SCALANCE M874-2 Version: All versions < V7.1.2
Siemens SCALANCE M874-3 Version: All versions < V7.1.2
Siemens SCALANCE M876-3 (EVDO) Version: All versions < V7.1.2
Siemens SCALANCE M876-3 (ROK) Version: All versions < V7.1.2
Siemens SCALANCE M876-4 (EU) Version: All versions < V7.1.2
Siemens SCALANCE M876-4 (NAM) Version: All versions < V7.1.2
Siemens SCALANCE MUM853-1 (EU) Version: All versions < V7.1.2
Siemens SCALANCE MUM856-1 (EU) Version: All versions < V7.1.2
Siemens SCALANCE MUM856-1 (RoW) Version: All versions < V7.1.2
Siemens SCALANCE S615 Version: All versions < V7.1.2
Siemens SCALANCE SC622-2C Version: All versions < V2.3.1
Siemens SCALANCE SC626-2C Version: All versions < V2.3.1
Siemens SCALANCE SC632-2C Version: All versions < V2.3.1
Siemens SCALANCE SC636-2C Version: All versions < V2.3.1
Siemens SCALANCE SC642-2C Version: All versions < V2.3.1
Siemens SCALANCE SC646-2C Version: All versions < V2.3.1
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1788-1 M12 Version: All versions
Siemens SCALANCE W1788-2 EEC M12 Version: All versions
Siemens SCALANCE W1788-2 M12 Version: All versions
Siemens SCALANCE W1788-2IA M12 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 EEC Version: All versions
Siemens SCALANCE W778-1 M12 EEC (USA) Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE WAM763-1 Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (US) Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE XB205-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB208 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB208 (PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB216 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB216 (PN) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (SC) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (ST/BFOC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP EEC Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G EEC Version: All versions < V4.4
Siemens SCALANCE XC208 Version: All versions < V4.4
Siemens SCALANCE XC208EEC Version: All versions < V4.4
Siemens SCALANCE XC208G Version: All versions < V4.4
Siemens SCALANCE XC208G (EIP def.) Version: All versions < V4.4
Siemens SCALANCE XC208G EEC Version: All versions < V4.4
Siemens SCALANCE XC208G PoE Version: All versions < V4.4
Siemens SCALANCE XC208G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216 Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216-4C Version: All versions < V4.4
Siemens SCALANCE XC216-4C G Version: All versions < V4.4
Siemens SCALANCE XC216-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC216-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XC216EEC Version: All versions < V4.4
Siemens SCALANCE XC224 Version: All versions < V4.4
Siemens SCALANCE XC224-4C G Version: All versions < V4.4
Siemens SCALANCE XC224-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC224-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XF204 Version: All versions < V4.4
Siemens SCALANCE XF204 DNA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA DNA Version: All versions < V4.4
Siemens SCALANCE XM408-4C Version: All versions < V6.6
Siemens SCALANCE XM408-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM408-8C Version: All versions < V6.6
Siemens SCALANCE XM408-8C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM416-4C Version: All versions < V6.6
Siemens SCALANCE XM416-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XP208 Version: All versions < V4.4
Siemens SCALANCE XP208 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP208EEC Version: All versions < V4.4
Siemens SCALANCE XP208PoE EEC Version: All versions < V4.4
Siemens SCALANCE XP216 Version: All versions < V4.4
Siemens SCALANCE XP216 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP216EEC Version: All versions < V4.4
Siemens SCALANCE XP216POE EEC Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG (without UL) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR524-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SIPLUS NET SCALANCE XC206-2 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC208 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC216-4C Version: All versions < V4.4
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:00:04.366Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (EVDO)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices do not properly sanitize an input field.  This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-10T10:20:59.701Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-36323",
    "datePublished": "2022-08-10T11:18:33",
    "dateReserved": "2022-07-20T00:00:00",
    "dateUpdated": "2024-08-03T10:00:04.366Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-44321
Vulnerability from cvelistv5
Published
2023-11-14 11:04
Modified
2024-08-13 07:52
Summary
Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: 0   < V8.1
Siemens SCALANCE M804PB Version: 0   < V8.1
Siemens SCALANCE M812-1 ADSL-Router family Version: 0   < V8.1
Siemens SCALANCE M816-1 ADSL-Router family Version: 0   < V8.1
Siemens SCALANCE M826-2 SHDSL-Router Version: 0   < V8.1
Siemens SCALANCE M874-2 Version: 0   < V8.1
Siemens SCALANCE M874-3 Version: 0   < V8.1
Siemens SCALANCE M874-3 3G-Router (CN) Version: 0   < V8.1
Siemens SCALANCE M876-3 Version: 0   < V8.1
Siemens SCALANCE M876-3 (ROK) Version: 0   < V8.1
Siemens SCALANCE M876-4 Version: 0   < V8.1
Siemens SCALANCE M876-4 (EU) Version: 0   < V8.1
Siemens SCALANCE M876-4 (NAM) Version: 0   < V8.1
Siemens SCALANCE MUM853-1 (A1) Version: 0   < V8.1
Siemens SCALANCE MUM853-1 (B1) Version: 0   < V8.1
Siemens SCALANCE MUM853-1 (EU) Version: 0   < V8.1
Siemens SCALANCE MUM856-1 (A1) Version: 0   < V8.1
Siemens SCALANCE MUM856-1 (B1) Version: 0   < V8.1
Siemens SCALANCE MUM856-1 (CN) Version: 0   < V8.1
Siemens SCALANCE MUM856-1 (EU) Version: 0   < V8.1
Siemens SCALANCE MUM856-1 (RoW) Version: 0   < V8.1
Siemens SCALANCE S615 EEC LAN-Router Version: 0   < V8.1
Siemens SCALANCE S615 LAN-Router Version: 0   < V8.1
Siemens SCALANCE XB205-3 (SC, PN) Version: 0   < *
Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < *
Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < *
Siemens SCALANCE XB205-3 (ST, PN) Version: 0   < *
Siemens SCALANCE XB205-3LD (SC, E/IP) Version: 0   < *
Siemens SCALANCE XB205-3LD (SC, PN) Version: 0   < *
Siemens SCALANCE XB208 (E/IP) Version: 0   < *
Siemens SCALANCE XB208 (PN) Version: 0   < *
Siemens SCALANCE XB213-3 (SC, E/IP) Version: 0   < *
Siemens SCALANCE XB213-3 (SC, PN) Version: 0   < *
Siemens SCALANCE XB213-3 (ST, E/IP) Version: 0   < *
Siemens SCALANCE XB213-3 (ST, PN) Version: 0   < *
Siemens SCALANCE XB213-3LD (SC, E/IP) Version: 0   < *
Siemens SCALANCE XB213-3LD (SC, PN) Version: 0   < *
Siemens SCALANCE XB216 (E/IP) Version: 0   < *
Siemens SCALANCE XB216 (PN) Version: 0   < *
Siemens SCALANCE XC206-2 (SC) Version: 0   < *
Siemens SCALANCE XC206-2 (ST/BFOC) Version: 0   < *
Siemens SCALANCE XC206-2G PoE Version: 0   < *
Siemens SCALANCE XC206-2G PoE (54 V DC) Version: 0   < *
Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: 0   < *
Siemens SCALANCE XC206-2SFP Version: 0   < *
Siemens SCALANCE XC206-2SFP EEC Version: 0   < *
Siemens SCALANCE XC206-2SFP G Version: 0   < *
Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: 0   < *
Siemens SCALANCE XC206-2SFP G EEC Version: 0   < *
Siemens SCALANCE XC208 Version: 0   < *
Siemens SCALANCE XC208EEC Version: 0   < *
Siemens SCALANCE XC208G Version: 0   < *
Siemens SCALANCE XC208G (EIP def.) Version: 0   < *
Siemens SCALANCE XC208G EEC Version: 0   < *
Siemens SCALANCE XC208G PoE Version: 0   < *
Siemens SCALANCE XC208G PoE (54 V DC) Version: 0   < *
Siemens SCALANCE XC216 Version: 0   < *
Siemens SCALANCE XC216-3G PoE Version: 0   < *
Siemens SCALANCE XC216-3G PoE (54 V DC) Version: 0   < *
Siemens SCALANCE XC216-4C Version: 0   < *
Siemens SCALANCE XC216-4C G Version: 0   < *
Siemens SCALANCE XC216-4C G (EIP Def.) Version: 0   < *
Siemens SCALANCE XC216-4C G EEC Version: 0   < *
Siemens SCALANCE XC216EEC Version: 0   < *
Siemens SCALANCE XC224 Version: 0   < *
Siemens SCALANCE XC224-4C G Version: 0   < *
Siemens SCALANCE XC224-4C G (EIP Def.) Version: 0   < *
Siemens SCALANCE XC224-4C G EEC Version: 0   < *
Siemens SCALANCE XF204 Version: 0   < *
Siemens SCALANCE XF204 DNA Version: 0   < *
Siemens SCALANCE XF204-2BA Version: 0   < *
Siemens SCALANCE XF204-2BA DNA Version: 0   < *
Siemens SCALANCE XP208 Version: 0   < *
Siemens SCALANCE XP208 (Ethernet/IP) Version: 0   < *
Siemens SCALANCE XP208EEC Version: 0   < *
Siemens SCALANCE XP208PoE EEC Version: 0   < *
Siemens SCALANCE XP216 Version: 0   < *
Siemens SCALANCE XP216 (Ethernet/IP) Version: 0   < *
Siemens SCALANCE XP216EEC Version: 0   < *
Siemens SCALANCE XP216POE EEC Version: 0   < *
Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: 0   < *
Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: 0   < *
Siemens SCALANCE XR326-2C PoE WG Version: 0   < *
Siemens SCALANCE XR326-2C PoE WG (without UL) Version: 0   < *
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: 0   < *
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: 0   < *
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < *
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < *
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: 0   < *
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: 0   < *
Siemens SIPLUS NET SCALANCE XC206-2 Version: 0   < *
Siemens SIPLUS NET SCALANCE XC206-2SFP Version: 0   < *
Siemens SIPLUS NET SCALANCE XC208 Version: 0   < *
Siemens SIPLUS NET SCALANCE XC216-4C Version: 0   < *
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:59:51.947Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-699386.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-699386.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-353002.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router family",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router family",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3 3G-Router (CN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (A1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (B1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (A1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (B1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (CN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 2.7,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:52:20.955Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-699386.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-699386.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-353002.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-087301.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-44321",
    "datePublished": "2023-11-14T11:04:02.880Z",
    "dateReserved": "2023-09-28T16:18:45.648Z",
    "dateUpdated": "2024-08-13T07:52:20.955Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-46140
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2024-08-03 14:24
Summary
Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: All versions < V7.2
Siemens SCALANCE M804PB Version: All versions < V7.2
Siemens SCALANCE M812-1 ADSL-Router (Annex A) Version: All versions < V7.2
Siemens SCALANCE M812-1 ADSL-Router (Annex B) Version: All versions < V7.2
Siemens SCALANCE M816-1 ADSL-Router (Annex A) Version: All versions < V7.2
Siemens SCALANCE M816-1 ADSL-Router (Annex B) Version: All versions < V7.2
Siemens SCALANCE M826-2 SHDSL-Router Version: All versions < V7.2
Siemens SCALANCE M874-2 Version: All versions < V7.2
Siemens SCALANCE M874-3 Version: All versions < V7.2
Siemens SCALANCE M876-3 (EVDO) Version: All versions < V7.2
Siemens SCALANCE M876-3 (ROK) Version: All versions < V7.2
Siemens SCALANCE M876-4 Version: All versions < V7.2
Siemens SCALANCE M876-4 (EU) Version: All versions < V7.2
Siemens SCALANCE M876-4 (NAM) Version: All versions < V7.2
Siemens SCALANCE MUM853-1 (EU) Version: All versions < V7.2
Siemens SCALANCE MUM856-1 (EU) Version: All versions < V7.2
Siemens SCALANCE MUM856-1 (RoW) Version: All versions < V7.2
Siemens SCALANCE S615 Version: All versions < V7.2
Siemens SCALANCE S615 EEC Version: All versions < V7.2
Siemens SCALANCE SC622-2C Version: All versions < V2.3
Siemens SCALANCE SC626-2C Version: All versions < V2.3
Siemens SCALANCE SC632-2C Version: All versions < V2.3
Siemens SCALANCE SC636-2C Version: All versions < V2.3
Siemens SCALANCE SC642-2C Version: All versions < V2.3
Siemens SCALANCE SC646-2C Version: All versions < V2.3
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1788-1 M12 Version: All versions
Siemens SCALANCE W1788-2 EEC M12 Version: All versions
Siemens SCALANCE W1788-2 M12 Version: All versions
Siemens SCALANCE W1788-2IA M12 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 EEC Version: All versions
Siemens SCALANCE W778-1 M12 EEC (USA) Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE WAM763-1 Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (US) Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE XB205-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB208 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB208 (PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB216 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB216 (PN) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (SC) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (ST/BFOC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP EEC Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G EEC Version: All versions < V4.4
Siemens SCALANCE XC208 Version: All versions < V4.4
Siemens SCALANCE XC208EEC Version: All versions < V4.4
Siemens SCALANCE XC208G Version: All versions < V4.4
Siemens SCALANCE XC208G (EIP def.) Version: All versions < V4.4
Siemens SCALANCE XC208G EEC Version: All versions < V4.4
Siemens SCALANCE XC208G PoE Version: All versions < V4.4
Siemens SCALANCE XC208G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216 Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216-4C Version: All versions < V4.4
Siemens SCALANCE XC216-4C G Version: All versions < V4.4
Siemens SCALANCE XC216-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC216-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XC216EEC Version: All versions < V4.4
Siemens SCALANCE XC224 Version: All versions < V4.4
Siemens SCALANCE XC224-4C G Version: All versions < V4.4
Siemens SCALANCE XC224-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC224-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XF204 Version: All versions < V4.4
Siemens SCALANCE XF204 DNA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA DNA Version: All versions < V4.4
Siemens SCALANCE XM408-4C Version: All versions < V6.6
Siemens SCALANCE XM408-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM408-8C Version: All versions < V6.6
Siemens SCALANCE XM408-8C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM416-4C Version: All versions < V6.6
Siemens SCALANCE XM416-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XP208 Version: All versions < V4.4
Siemens SCALANCE XP208 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP208EEC Version: All versions < V4.4
Siemens SCALANCE XP208PoE EEC Version: All versions < V4.4
Siemens SCALANCE XP216 Version: All versions < V4.4
Siemens SCALANCE XP216 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP216EEC Version: All versions < V4.4
Siemens SCALANCE XP216POE EEC Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG (without UL) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR524-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SIPLUS NET SCALANCE XC206-2 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC208 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC216-4C Version: All versions < V4.4
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:24:03.297Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (EVDO)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-327",
              "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-10T10:21:07.520Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-46140",
    "datePublished": "2022-12-13T00:00:00",
    "dateReserved": "2022-11-28T00:00:00",
    "dateUpdated": "2024-08-03T14:24:03.297Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-44318
Vulnerability from cvelistv5
Published
2023-11-14 11:03
Modified
2024-09-10 09:34
Summary
Affected devices use a hardcoded key to obfuscate the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that obtains a configuration backup to extract configuration information from the exported file.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: All versions
Siemens SCALANCE M804PB Version: All versions
Siemens SCALANCE M812-1 ADSL-Router Version: All versions
Siemens SCALANCE M812-1 ADSL-Router Version: All versions
Siemens SCALANCE M816-1 ADSL-Router Version: All versions
Siemens SCALANCE M816-1 ADSL-Router Version: All versions
Siemens SCALANCE M826-2 SHDSL-Router Version: All versions
Siemens SCALANCE M874-2 Version: All versions
Siemens SCALANCE M874-3 Version: All versions
Siemens SCALANCE M876-3 Version: All versions
Siemens SCALANCE M876-3 (ROK) Version: All versions
Siemens SCALANCE M876-4 Version: All versions
Siemens SCALANCE M876-4 (EU) Version: All versions
Siemens SCALANCE M876-4 (NAM) Version: All versions
Siemens SCALANCE MUM853-1 (EU) Version: All versions
Siemens SCALANCE MUM856-1 (EU) Version: All versions
Siemens SCALANCE MUM856-1 (RoW) Version: All versions
Siemens SCALANCE S615 EEC LAN-Router Version: All versions
Siemens SCALANCE S615 LAN-Router Version: All versions
Siemens SCALANCE WAB762-1 Version: 0   < *
Siemens SCALANCE WAM763-1 Version: 0   < *
Siemens SCALANCE WAM763-1 (ME) Version: 0   < *
Siemens SCALANCE WAM763-1 (US) Version: 0   < *
Siemens SCALANCE WAM766-1 (EU) Version: 0   < *
Siemens SCALANCE WAM766-1 (ME) Version: 0   < *
Siemens SCALANCE WAM766-1 (US) Version: 0   < *
Siemens SCALANCE WAM766-1 EEC (EU) Version: 0   < *
Siemens SCALANCE WAM766-1 EEC (ME) Version: 0   < *
Siemens SCALANCE WAM766-1 EEC (US) Version: 0   < *
Siemens SCALANCE WUB762-1 Version: 0   < *
Siemens SCALANCE WUB762-1 Version: 0   < *
Siemens SCALANCE WUM763-1 Version: 0   < *
Siemens SCALANCE WUM763-1 Version: 0   < *
Siemens SCALANCE WUM763-1 (US) Version: 0   < *
Siemens SCALANCE WUM763-1 (US) Version: 0   < *
Siemens SCALANCE WUM766-1 (EU) Version: 0   < *
Siemens SCALANCE WUM766-1 (ME) Version: 0   < *
Siemens SCALANCE WUM766-1 (US) Version: 0   < *
Siemens SCALANCE XB205-3 (SC, PN) Version: 0   < *
Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < *
Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < *
Siemens SCALANCE XB205-3 (ST, PN) Version: 0   < *
Siemens SCALANCE XB205-3LD (SC, E/IP) Version: 0   < *
Siemens SCALANCE XB205-3LD (SC, PN) Version: 0   < *
Siemens SCALANCE XB208 (E/IP) Version: 0   < *
Siemens SCALANCE XB208 (PN) Version: 0   < *
Siemens SCALANCE XB213-3 (SC, E/IP) Version: 0   < *
Siemens SCALANCE XB213-3 (SC, PN) Version: 0   < *
Siemens SCALANCE XB213-3 (ST, E/IP) Version: 0   < *
Siemens SCALANCE XB213-3 (ST, PN) Version: 0   < *
Siemens SCALANCE XB213-3LD (SC, E/IP) Version: 0   < *
Siemens SCALANCE XB213-3LD (SC, PN) Version: 0   < *
Siemens SCALANCE XB216 (E/IP) Version: 0   < *
Siemens SCALANCE XB216 (PN) Version: 0   < *
Siemens SCALANCE XC206-2 (SC) Version: 0   < *
Siemens SCALANCE XC206-2 (ST/BFOC) Version: 0   < *
Siemens SCALANCE XC206-2G PoE Version: 0   < *
Siemens SCALANCE XC206-2G PoE (54 V DC) Version: 0   < *
Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: 0   < *
Siemens SCALANCE XC206-2SFP Version: 0   < *
Siemens SCALANCE XC206-2SFP EEC Version: 0   < *
Siemens SCALANCE XC206-2SFP G Version: 0   < *
Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: 0   < *
Siemens SCALANCE XC206-2SFP G EEC Version: 0   < *
Siemens SCALANCE XC208 Version: 0   < *
Siemens SCALANCE XC208EEC Version: 0   < *
Siemens SCALANCE XC208G Version: 0   < *
Siemens SCALANCE XC208G (EIP def.) Version: 0   < *
Siemens SCALANCE XC208G EEC Version: 0   < *
Siemens SCALANCE XC208G PoE Version: 0   < *
Siemens SCALANCE XC208G PoE (54 V DC) Version: 0   < *
Siemens SCALANCE XC216 Version: 0   < *
Siemens SCALANCE XC216-3G PoE Version: 0   < *
Siemens SCALANCE XC216-3G PoE (54 V DC) Version: 0   < *
Siemens SCALANCE XC216-4C Version: 0   < *
Siemens SCALANCE XC216-4C G Version: 0   < *
Siemens SCALANCE XC216-4C G (EIP Def.) Version: 0   < *
Siemens SCALANCE XC216-4C G EEC Version: 0   < *
Siemens SCALANCE XC216EEC Version: 0   < *
Siemens SCALANCE XC224 Version: 0   < *
Siemens SCALANCE XC224-4C G Version: 0   < *
Siemens SCALANCE XC224-4C G (EIP Def.) Version: 0   < *
Siemens SCALANCE XC224-4C G EEC Version: 0   < *
Siemens SCALANCE XF204 Version: 0   < *
Siemens SCALANCE XF204 DNA Version: 0   < *
Siemens SCALANCE XF204-2BA Version: 0   < *
Siemens SCALANCE XF204-2BA DNA Version: 0   < *
Siemens SCALANCE XP208 Version: 0   < *
Siemens SCALANCE XP208 (Ethernet/IP) Version: 0   < *
Siemens SCALANCE XP208EEC Version: 0   < *
Siemens SCALANCE XP208PoE EEC Version: 0   < *
Siemens SCALANCE XP216 Version: 0   < *
Siemens SCALANCE XP216 (Ethernet/IP) Version: 0   < *
Siemens SCALANCE XP216EEC Version: 0   < *
Siemens SCALANCE XP216POE EEC Version: 0   < *
Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: 0   < *
Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: 0   < *
Siemens SCALANCE XR326-2C PoE WG Version: 0   < *
Siemens SCALANCE XR326-2C PoE WG (without UL) Version: 0   < *
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: 0   < *
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: 0   < *
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < *
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < *
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: 0   < *
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: 0   < *
Siemens SIPLUS NET SCALANCE XC206-2 Version: 0   < *
Siemens SIPLUS NET SCALANCE XC206-2SFP Version: 0   < *
Siemens SIPLUS NET SCALANCE XC208 Version: 0   < *
Siemens SIPLUS NET SCALANCE XC216-4C Version: 0   < *
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:59:51.959Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-699386.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-353002.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAB762-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUB762-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUB762-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices use a hardcoded key to obfuscate the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that obtains a configuration backup to extract configuration information from the exported file."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:U/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321: Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:34:16.175Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-699386.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-353002.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-44318",
    "datePublished": "2023-11-14T11:03:52.696Z",
    "dateReserved": "2023-09-28T16:18:45.648Z",
    "dateUpdated": "2024-09-10T09:34:16.175Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-36325
Vulnerability from cvelistv5
Published
2022-08-10 11:18
Modified
2024-08-03 10:00
Summary
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: All versions < V7.1.2
Siemens SCALANCE M804PB Version: All versions < V7.1.2
Siemens SCALANCE M812-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Siemens SCALANCE M812-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Siemens SCALANCE M816-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Siemens SCALANCE M816-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Siemens SCALANCE M826-2 SHDSL-Router Version: All versions < V7.1.2
Siemens SCALANCE M874-2 Version: All versions < V7.1.2
Siemens SCALANCE M874-3 Version: All versions < V7.1.2
Siemens SCALANCE M876-3 (EVDO) Version: All versions < V7.1.2
Siemens SCALANCE M876-3 (ROK) Version: All versions < V7.1.2
Siemens SCALANCE M876-4 (EU) Version: All versions < V7.1.2
Siemens SCALANCE M876-4 (NAM) Version: All versions < V7.1.2
Siemens SCALANCE MUM853-1 (EU) Version: All versions < V7.1.2
Siemens SCALANCE MUM856-1 (EU) Version: All versions < V7.1.2
Siemens SCALANCE MUM856-1 (RoW) Version: All versions < V7.1.2
Siemens SCALANCE S615 Version: All versions < V7.1.2
Siemens SCALANCE SC622-2C Version: All versions < V2.3.1
Siemens SCALANCE SC626-2C Version: All versions < V2.3.1
Siemens SCALANCE SC632-2C Version: All versions < V2.3.1
Siemens SCALANCE SC636-2C Version: All versions < V2.3.1
Siemens SCALANCE SC642-2C Version: All versions < V2.3.1
Siemens SCALANCE SC646-2C Version: All versions < V2.3.1
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1788-1 M12 Version: All versions
Siemens SCALANCE W1788-2 EEC M12 Version: All versions
Siemens SCALANCE W1788-2 M12 Version: All versions
Siemens SCALANCE W1788-2IA M12 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 EEC Version: All versions
Siemens SCALANCE W778-1 M12 EEC (USA) Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE WAM763-1 Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (US) Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE XB205-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB208 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB208 (PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB216 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB216 (PN) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (SC) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (ST/BFOC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP EEC Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G EEC Version: All versions < V4.4
Siemens SCALANCE XC208 Version: All versions < V4.4
Siemens SCALANCE XC208EEC Version: All versions < V4.4
Siemens SCALANCE XC208G Version: All versions < V4.4
Siemens SCALANCE XC208G (EIP def.) Version: All versions < V4.4
Siemens SCALANCE XC208G EEC Version: All versions < V4.4
Siemens SCALANCE XC208G PoE Version: All versions < V4.4
Siemens SCALANCE XC208G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216 Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216-4C Version: All versions < V4.4
Siemens SCALANCE XC216-4C G Version: All versions < V4.4
Siemens SCALANCE XC216-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC216-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XC216EEC Version: All versions < V4.4
Siemens SCALANCE XC224 Version: All versions < V4.4
Siemens SCALANCE XC224-4C G Version: All versions < V4.4
Siemens SCALANCE XC224-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC224-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XF204 Version: All versions < V4.4
Siemens SCALANCE XF204 DNA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA DNA Version: All versions < V4.4
Siemens SCALANCE XM408-4C Version: All versions < V6.6
Siemens SCALANCE XM408-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM408-8C Version: All versions < V6.6
Siemens SCALANCE XM408-8C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM416-4C Version: All versions < V6.6
Siemens SCALANCE XM416-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XP208 Version: All versions < V4.4
Siemens SCALANCE XP208 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP208EEC Version: All versions < V4.4
Siemens SCALANCE XP208PoE EEC Version: All versions < V4.4
Siemens SCALANCE XP216 Version: All versions < V4.4
Siemens SCALANCE XP216 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP216EEC Version: All versions < V4.4
Siemens SCALANCE XP216POE EEC Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG (without UL) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR524-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SIPLUS NET SCALANCE XC206-2 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC208 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC216-4C Version: All versions < V4.4
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:00:04.293Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (EVDO)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-10T10:21:04.880Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-36325",
    "datePublished": "2022-08-10T11:18:45",
    "dateReserved": "2022-07-20T00:00:00",
    "dateUpdated": "2024-08-03T10:00:04.293Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-36324
Vulnerability from cvelistv5
Published
2022-08-10 11:18
Modified
2024-08-03 10:00
Summary
Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: All versions < V7.1.2
Siemens SCALANCE M804PB Version: All versions < V7.1.2
Siemens SCALANCE M812-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Siemens SCALANCE M812-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Siemens SCALANCE M816-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Siemens SCALANCE M816-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Siemens SCALANCE M826-2 SHDSL-Router Version: All versions < V7.1.2
Siemens SCALANCE M874-2 Version: All versions < V7.1.2
Siemens SCALANCE M874-3 Version: All versions < V7.1.2
Siemens SCALANCE M876-3 (EVDO) Version: All versions < V7.1.2
Siemens SCALANCE M876-3 (ROK) Version: All versions < V7.1.2
Siemens SCALANCE M876-4 (EU) Version: All versions < V7.1.2
Siemens SCALANCE M876-4 (NAM) Version: All versions < V7.1.2
Siemens SCALANCE MUM853-1 (EU) Version: All versions < V7.1.2
Siemens SCALANCE MUM856-1 (EU) Version: All versions < V7.1.2
Siemens SCALANCE MUM856-1 (RoW) Version: All versions < V7.1.2
Siemens SCALANCE S615 Version: All versions < V7.1.2
Siemens SCALANCE SC622-2C Version: All versions < V2.3.1
Siemens SCALANCE SC626-2C Version: All versions < V2.3.1
Siemens SCALANCE SC632-2C Version: All versions < V2.3.1
Siemens SCALANCE SC636-2C Version: All versions < V2.3.1
Siemens SCALANCE SC642-2C Version: All versions < V2.3.1
Siemens SCALANCE SC646-2C Version: All versions < V2.3.1
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1788-1 M12 Version: All versions
Siemens SCALANCE W1788-2 EEC M12 Version: All versions
Siemens SCALANCE W1788-2 M12 Version: All versions
Siemens SCALANCE W1788-2IA M12 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 EEC Version: All versions
Siemens SCALANCE W778-1 M12 EEC (USA) Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE WAM763-1 Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (US) Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE XB205-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB208 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB208 (PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB216 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB216 (PN) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (SC) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (ST/BFOC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP EEC Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G EEC Version: All versions < V4.4
Siemens SCALANCE XC208 Version: All versions < V4.4
Siemens SCALANCE XC208EEC Version: All versions < V4.4
Siemens SCALANCE XC208G Version: All versions < V4.4
Siemens SCALANCE XC208G (EIP def.) Version: All versions < V4.4
Siemens SCALANCE XC208G EEC Version: All versions < V4.4
Siemens SCALANCE XC208G PoE Version: All versions < V4.4
Siemens SCALANCE XC208G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216 Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216-4C Version: All versions < V4.4
Siemens SCALANCE XC216-4C G Version: All versions < V4.4
Siemens SCALANCE XC216-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC216-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XC216EEC Version: All versions < V4.4
Siemens SCALANCE XC224 Version: All versions < V4.4
Siemens SCALANCE XC224-4C G Version: All versions < V4.4
Siemens SCALANCE XC224-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC224-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XF204 Version: All versions < V4.4
Siemens SCALANCE XF204 DNA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA DNA Version: All versions < V4.4
Siemens SCALANCE XM408-4C Version: All versions < V6.6
Siemens SCALANCE XM408-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM408-8C Version: All versions < V6.6
Siemens SCALANCE XM408-8C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM416-4C Version: All versions < V6.6
Siemens SCALANCE XM416-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XP208 Version: All versions < V4.4
Siemens SCALANCE XP208 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP208EEC Version: All versions < V4.4
Siemens SCALANCE XP208PoE EEC Version: All versions < V4.4
Siemens SCALANCE XP216 Version: All versions < V4.4
Siemens SCALANCE XP216 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP216EEC Version: All versions < V4.4
Siemens SCALANCE XP216POE EEC Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG (without UL) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR524-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SIPLUS NET SCALANCE XC206-2 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC208 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC216-4C Version: All versions < V4.4
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:00:04.354Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (EVDO)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-10T10:21:02.321Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-36324",
    "datePublished": "2022-08-10T11:18:39",
    "dateReserved": "2022-07-20T00:00:00",
    "dateUpdated": "2024-08-03T10:00:04.354Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-46142
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2024-08-03 14:24
Summary
Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: All versions < V7.2
Siemens SCALANCE M804PB Version: All versions < V7.2
Siemens SCALANCE M812-1 ADSL-Router (Annex A) Version: All versions < V7.2
Siemens SCALANCE M812-1 ADSL-Router (Annex B) Version: All versions < V7.2
Siemens SCALANCE M816-1 ADSL-Router (Annex A) Version: All versions < V7.2
Siemens SCALANCE M816-1 ADSL-Router (Annex B) Version: All versions < V7.2
Siemens SCALANCE M826-2 SHDSL-Router Version: All versions < V7.2
Siemens SCALANCE M874-2 Version: All versions < V7.2
Siemens SCALANCE M874-3 Version: All versions < V7.2
Siemens SCALANCE M876-3 (EVDO) Version: All versions < V7.2
Siemens SCALANCE M876-3 (ROK) Version: All versions < V7.2
Siemens SCALANCE M876-4 Version: All versions < V7.2
Siemens SCALANCE M876-4 (EU) Version: All versions < V7.2
Siemens SCALANCE M876-4 (NAM) Version: All versions < V7.2
Siemens SCALANCE MUM853-1 (EU) Version: All versions < V7.2
Siemens SCALANCE MUM856-1 (EU) Version: All versions < V7.2
Siemens SCALANCE MUM856-1 (RoW) Version: All versions < V7.2
Siemens SCALANCE S615 Version: All versions < V7.2
Siemens SCALANCE S615 EEC Version: All versions < V7.2
Siemens SCALANCE SC622-2C Version: All versions < V2.3
Siemens SCALANCE SC622-2C Version: All versions >= V2.3 < V3.0
Siemens SCALANCE SC626-2C Version: All versions < V2.3
Siemens SCALANCE SC626-2C Version: All versions >= V2.3 < V3.0
Siemens SCALANCE SC632-2C Version: All versions < V2.3
Siemens SCALANCE SC632-2C Version: All versions >= V2.3 < V3.0
Siemens SCALANCE SC636-2C Version: All versions < V2.3
Siemens SCALANCE SC636-2C Version: All versions >= V2.3 < V3.0
Siemens SCALANCE SC642-2C Version: All versions < V2.3
Siemens SCALANCE SC642-2C Version: All versions >= V2.3 < V3.0
Siemens SCALANCE SC646-2C Version: All versions < V2.3
Siemens SCALANCE SC646-2C Version: All versions >= V2.3 < V3.0
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1788-1 M12 Version: All versions
Siemens SCALANCE W1788-2 EEC M12 Version: All versions
Siemens SCALANCE W1788-2 M12 Version: All versions
Siemens SCALANCE W1788-2IA M12 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 EEC Version: All versions
Siemens SCALANCE W778-1 M12 EEC (USA) Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE WAM763-1 Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (US) Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE XB205-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB208 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB208 (PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB216 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB216 (PN) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (SC) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (ST/BFOC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP EEC Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G EEC Version: All versions < V4.4
Siemens SCALANCE XC208 Version: All versions < V4.4
Siemens SCALANCE XC208EEC Version: All versions < V4.4
Siemens SCALANCE XC208G Version: All versions < V4.4
Siemens SCALANCE XC208G (EIP def.) Version: All versions < V4.4
Siemens SCALANCE XC208G EEC Version: All versions < V4.4
Siemens SCALANCE XC208G PoE Version: All versions < V4.4
Siemens SCALANCE XC208G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216 Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216-4C Version: All versions < V4.4
Siemens SCALANCE XC216-4C G Version: All versions < V4.4
Siemens SCALANCE XC216-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC216-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XC216EEC Version: All versions < V4.4
Siemens SCALANCE XC224 Version: All versions < V4.4
Siemens SCALANCE XC224-4C G Version: All versions < V4.4
Siemens SCALANCE XC224-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC224-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XF204 Version: All versions < V4.4
Siemens SCALANCE XF204 DNA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA DNA Version: All versions < V4.4
Siemens SCALANCE XM408-4C Version: All versions < V6.6
Siemens SCALANCE XM408-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM408-8C Version: All versions < V6.6
Siemens SCALANCE XM408-8C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM416-4C Version: All versions < V6.6
Siemens SCALANCE XM416-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XP208 Version: All versions < V4.4
Siemens SCALANCE XP208 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP208EEC Version: All versions < V4.4
Siemens SCALANCE XP208PoE EEC Version: All versions < V4.4
Siemens SCALANCE XP216 Version: All versions < V4.4
Siemens SCALANCE XP216 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP216EEC Version: All versions < V4.4
Siemens SCALANCE XP216POE EEC Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG (without UL) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR524-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SIPLUS NET SCALANCE XC206-2 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC208 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC216-4C Version: All versions < V4.4
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:24:03.321Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (EVDO)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-257",
              "description": "CWE-257: Storing Passwords in a Recoverable Format",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-10T10:21:11.037Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-46142",
    "datePublished": "2022-12-13T00:00:00",
    "dateReserved": "2022-11-28T00:00:00",
    "dateUpdated": "2024-08-03T14:24:03.321Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

var-202208-0612
Vulnerability from variot

Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS. SCALANCE M-800 firmware, SCALANCE S615 firmware, SCALANCE SC-600 Multiple Siemens products such as firmware have unspecified vulnerabilities.Information may be obtained and information may be tampered with. SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 industrial routers are used for secure remote access to plants via mobile networks (e.g. GPRS or UMTS) and have integrated security functions of firewalls to prevent unauthorized access, as well as VPNs to Secure data transmission. SCALANCE SC-600 devices (SC622-2C, SC632-2C, SC636-2C, SC642-2C, SC646-2C) are used to protect trusted industrial networks from untrusted network attacks. They allow filtering incoming and outgoing network connections in different ways. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. SCALANCE W-700 products are wireless communication devices based on the IEEE 802.11ax standard. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE SC-600 family (All versions < V2.3.1), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202208-0612",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xr552-12m 2hr2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224-4c g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w700 ieee 802.11ac",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr524-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb205-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance sc-600",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.1"
      },
      {
        "model": "scalance xb208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324-4m poe ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr524-8c l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216-4c g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr528-6m l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance sc642-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.1"
      },
      {
        "model": "scalance sc632-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.1"
      },
      {
        "model": "scalance xr324-12m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc-200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr528-6m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2ba irt",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm400",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr-300eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr500",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208 \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w700 ieee 802.11n",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb213-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm408-8c l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr552-12m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm416-4c l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr552",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr-300",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr328-4c wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr526-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb-200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance sc636-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.1"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp216 \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf-200ba",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr528-6m 2hr2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm408-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr-300poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr552-12m 2hr2 l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w700 ieee 802.11ax",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm408-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm408-4c l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr326-2c poe wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr552-12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324-12m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr524",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp-200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance s615",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr528-6m 2hr2 l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp216eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324-4m eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr528",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance sc622-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.1"
      },
      {
        "model": "scalance xc208g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance sc646-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.1"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance m-800",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm416-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr526-8c l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr526",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr-300wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance sc-646-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb205-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-600",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc206-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb-200",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance w700 ieee 802.11ax",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb216",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-622-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc-200",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m-800",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb213-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-632-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb213-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-642-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance w700 ieee 802.11ac",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance w700 ieee 802.11n",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb205-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-636-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance s615",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb208",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m-800 s615",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "/"
      },
      {
        "model": "scalance sc-600 family",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v2.3.1"
      },
      {
        "model": "scalance w-700 ieee 802.11ax family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w-700 ieee 802.11n family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w-1700 ieee 802.11ac family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb-200 switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc-200 switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xf-200ba switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xm-400 family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp-200 switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr-300wg switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr-500 family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56474"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014931"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36325"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens has reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2711"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-36325",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-56474",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.7,
            "id": "CVE-2022-36325",
            "impactScore": 2.7,
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "productcert@siemens.com",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 0.9,
            "id": "CVE-2022-36325",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 4.8,
            "baseSeverity": "Medium",
            "confidentialityImpact": "Low",
            "exploitabilityScore": null,
            "id": "CVE-2022-36325",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "High",
            "scope": "Changed",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-36325",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2022-36325",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-36325",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-56474",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202208-2711",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56474"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014931"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2711"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36325"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36325"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS. SCALANCE M-800 firmware, SCALANCE S615 firmware, SCALANCE SC-600 Multiple Siemens products such as firmware have unspecified vulnerabilities.Information may be obtained and information may be tampered with. SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 industrial routers are used for secure remote access to plants via mobile networks (e.g. GPRS or UMTS) and have integrated security functions of firewalls to prevent unauthorized access, as well as VPNs to Secure data transmission. SCALANCE SC-600 devices (SC622-2C, SC632-2C, SC636-2C, SC642-2C, SC646-2C) are used to protect trusted industrial networks from untrusted network attacks. They allow filtering incoming and outgoing network connections in different ways. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. SCALANCE W-700 products are wireless communication devices based on the IEEE 802.11ax standard. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE SC-600 family (All versions \u003c V2.3.1), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-36325"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014931"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-56474"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36325"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-36325",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-710008",
        "trust": 3.1
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-223-07",
        "trust": 1.5
      },
      {
        "db": "JVN",
        "id": "JVNVU90767165",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014931",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-56474",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2022.4032",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2711",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36325",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56474"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36325"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014931"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2711"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36325"
      }
    ]
  },
  "id": "VAR-202208-0612",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56474"
      }
    ],
    "trust": 1.2477712656666666
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56474"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:17:48.938000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Unknown Vulnerability in Siemens SCALANCE Products (CNVD-2022-56474)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/343626"
      },
      {
        "title": "Siemens SCALANCE Security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=243184"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56474"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2711"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-80",
        "trust": 1.0
      },
      {
        "problemtype": "NVD-CWE-Other",
        "trust": 1.0
      },
      {
        "problemtype": "others (CWE-Other) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014931"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36325"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu90767165/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-36325"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-223-07"
      },
      {
        "trust": 0.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-36325/"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2022.4032"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-223-07"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/80.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-07"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56474"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36325"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014931"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2711"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36325"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56474"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36325"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014931"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2711"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36325"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-08-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-56474"
      },
      {
        "date": "2022-08-10T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-36325"
      },
      {
        "date": "2023-09-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-014931"
      },
      {
        "date": "2022-08-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-2711"
      },
      {
        "date": "2022-08-10T12:15:12.997000",
        "db": "NVD",
        "id": "CVE-2022-36325"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-08-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-56474"
      },
      {
        "date": "2022-08-10T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-36325"
      },
      {
        "date": "2023-09-22T08:25:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-014931"
      },
      {
        "date": "2023-06-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-2711"
      },
      {
        "date": "2023-06-27T19:51:47.307000",
        "db": "NVD",
        "id": "CVE-2022-36325"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2711"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerabilities in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014931"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2711"
      }
    ],
    "trust": 0.6
  }
}

var-202311-0436
Vulnerability from variot

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0). Affected devices can be configured to send emails when certain events occur on the device. When presented with an invalid response from the SMTP server, the device triggers an error that disrupts email sending. An attacker with access to the network can use this to do disable notification of users when certain events occur. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain vulnerabilities related to unchecked return values.Service operation interruption (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202311-0436",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "6gk5208-0ra00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ra00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5324-0ba00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-2rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-5fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bf00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bb00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2as6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bb00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-0ba00-2yf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bb00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bf00-2tb2",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bb00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bf00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-2aa00-2yf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5324-0ba00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4bs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bf00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2ts6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-0ba00-2gf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4ss00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ua00-5es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bb00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1206-2bs00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1208-0ba00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ua00-5es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bd00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bd00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2as6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-2aa00-2gf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5326-2qs00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5326-2qs00-3rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-3rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-3rs00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4ss00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1206-2bb00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bd00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1216-4bs00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2ts6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-3rs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2bb00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bd00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bf00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5208-0ba00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bb00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2bd00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2rs00-5ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5216-0ba00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bd00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bf00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bd00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5216-0ba00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bb00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5208-0ba00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bf00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bb00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bb00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bf00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2rs00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr324wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr326-2c poe wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr328-4c wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-3g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86592"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017958"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44322"
      }
    ]
  },
  "cve": "CVE-2023-44322",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "HIGH",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 2.6,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 4.9,
            "id": "CNVD-2023-86592",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.6,
            "vectorString": "AV:N/AC:H/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.2,
            "id": "CVE-2023-44322",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "productcert@siemens.com",
            "availabilityImpact": "LOW",
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.2,
            "id": "CVE-2023-44322",
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "High",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 5.9,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2023-44322",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-44322",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2023-44322",
            "trust": 1.0,
            "value": "LOW"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-44322",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-86592",
            "trust": 0.6,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86592"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017958"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44322"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44322"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions \u003c V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions \u003c V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions \u003c V8.0). Affected devices can be configured to send emails when certain events occur on the device. When presented with an invalid response from the SMTP server, the device triggers an error that disrupts email sending. An attacker with access to the network can use this to do disable notification of users when certain events occur. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain vulnerabilities related to unchecked return values.Service operation interruption (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-44322"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017958"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86592"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44322"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-44322",
        "trust": 3.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-699386",
        "trust": 2.5
      },
      {
        "db": "SIEMENS",
        "id": "SSA-180704",
        "trust": 1.8
      },
      {
        "db": "SIEMENS",
        "id": "SSA-602936",
        "trust": 1.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-320-08",
        "trust": 0.9
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-348-14",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-046-09",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU98271228",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU91198149",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU92598492",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017958",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86592",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44322",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86592"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44322"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017958"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44322"
      }
    ]
  },
  "id": "VAR-202311-0436",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86592"
      }
    ],
    "trust": 1.2076912
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86592"
      }
    ]
  },
  "last_update_date": "2024-08-14T12:14:17.114000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Unchecked return value vulnerabilities in multiple Siemens products",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/482276"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86592"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-252",
        "trust": 1.0
      },
      {
        "problemtype": "Unchecked return value (CWE-252) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017958"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44322"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-699386.pdf"
      },
      {
        "trust": 1.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
      },
      {
        "trust": 1.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-699386.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html"
      },
      {
        "trust": 0.9,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-08"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu92598492/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu98271228/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91198149/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-44322"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-14"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-09"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86592"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44322"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017958"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44322"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86592"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44322"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017958"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44322"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86592"
      },
      {
        "date": "2023-11-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44322"
      },
      {
        "date": "2024-01-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017958"
      },
      {
        "date": "2023-11-14T11:15:13.187000",
        "db": "NVD",
        "id": "CVE-2023-44322"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86592"
      },
      {
        "date": "2023-11-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44322"
      },
      {
        "date": "2024-02-19T06:56:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017958"
      },
      {
        "date": "2024-08-13T08:15:07.770000",
        "db": "NVD",
        "id": "CVE-2023-44322"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Unchecked return value vulnerability in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017958"
      }
    ],
    "trust": 0.8
  }
}

var-202311-0439
Vulnerability from variot

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V2.4.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V2.4.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V2.4.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V2.4.0), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions < V2.4.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V2.4.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V2.4.0), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions < V2.4.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V2.4.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V2.4.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V2.4.0), SCALANCE WUB762-1 (6GK5762-1AJ00-2AA0) (All versions < V2.4.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V2.4.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V2.4.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V2.4.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V2.4.0), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions < V2.4.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V2.4.0), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions < V2.4.0). Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202311-0439",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "6gk5216-0ba00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-3rs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5326-2qs00-3rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ua00-5es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bf00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ra00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-0ba00-2gf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4ss00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-3rs00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-3rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1206-2bb00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1208-0ba00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bf00-2tb2",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-0ba00-2yf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-5fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5324-0ba00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1216-4bs00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bd00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1206-2bs00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2ts6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bb00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bb00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bb00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4bs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ua00-5es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5324-0ba00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4ss00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bb00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bd00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bd00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-2aa00-2yf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bf00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5326-2qs00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bb00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ra00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-2rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2as6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2ts6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-2aa00-2gf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2as6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bf00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bf00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bb00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5208-0ba00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bd00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bb00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bf00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5216-0ba00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2bd00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bd00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bd00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bf00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bd00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bb00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2rs00-5ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2rs00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5208-0ba00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5216-0ba00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bf00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2bb00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bb00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr324wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr326-2c poe wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr328-4c wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-3g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86591"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017957"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44373"
      }
    ]
  },
  "cve": "CVE-2023-44373",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2023-86591",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "productcert@siemens.com",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.3,
            "id": "CVE-2023-44373",
            "impactScore": 6.0,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 9.1,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2023-017957",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Changed",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2023-44373",
            "trust": 1.0,
            "value": "Critical"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2023-017957",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-86591",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86591"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017957"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44373"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions \u003c V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions \u003c V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions \u003c V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions \u003c V2.4.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions \u003c V2.4.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions \u003c V2.4.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions \u003c V2.4.0), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions \u003c V2.4.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions \u003c V2.4.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions \u003c V2.4.0), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions \u003c V2.4.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions \u003c V2.4.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions \u003c V2.4.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions \u003c V2.4.0), SCALANCE WUB762-1 (6GK5762-1AJ00-2AA0) (All versions \u003c V2.4.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions \u003c V2.4.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions \u003c V2.4.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions \u003c V2.4.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions \u003c V2.4.0), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions \u003c V2.4.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions \u003c V2.4.0), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions \u003c V2.4.0). Affected devices do not properly sanitize an input field.  This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-44373"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017957"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86591"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44373"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-44373",
        "trust": 3.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-699386",
        "trust": 2.5
      },
      {
        "db": "SIEMENS",
        "id": "SSA-180704",
        "trust": 1.8
      },
      {
        "db": "SIEMENS",
        "id": "SSA-602936",
        "trust": 1.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-721642",
        "trust": 1.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-690517",
        "trust": 1.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-320-08",
        "trust": 0.9
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-348-14",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-046-09",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-256-13",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-165-12",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU93250330",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU91198149",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU98271228",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU90825867",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU92598492",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017957",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86591",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44373",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86591"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44373"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017957"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44373"
      }
    ]
  },
  "id": "VAR-202311-0439",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86591"
      }
    ],
    "trust": 1.2076912
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86591"
      }
    ]
  },
  "last_update_date": "2024-09-14T21:10:00.510000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Input validation error vulnerability in multiple Siemens products (CNVD-2023-86591)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/482281"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86591"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-74",
        "trust": 1.0
      },
      {
        "problemtype": "injection (CWE-74) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017957"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44373"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-699386.pdf"
      },
      {
        "trust": 1.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
      },
      {
        "trust": 1.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-699386.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-721642.html"
      },
      {
        "trust": 0.9,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-08"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu92598492/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu98271228/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91198149/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu93250330/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu90825867/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-44373"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-14"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-09"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-12"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-256-13"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86591"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44373"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017957"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44373"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86591"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44373"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017957"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44373"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86591"
      },
      {
        "date": "2023-11-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44373"
      },
      {
        "date": "2024-01-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017957"
      },
      {
        "date": "2023-11-14T11:15:13.417000",
        "db": "NVD",
        "id": "CVE-2023-44373"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86591"
      },
      {
        "date": "2023-11-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44373"
      },
      {
        "date": "2024-09-13T05:56:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017957"
      },
      {
        "date": "2024-09-10T10:15:07.217000",
        "db": "NVD",
        "id": "CVE-2023-44373"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Injection vulnerabilities in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017957"
      }
    ],
    "trust": 0.8
  }
}

var-202311-0441
Vulnerability from variot

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-2AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions). Affected devices use a weak checksum algorithm to protect the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that tricks a legitimate administrator to upload a modified configuration file to change the configuration of an affected device. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain vulnerabilities related to the use of weak hashes.Information may be tampered with. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202311-0441",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "6gk5216-0ba00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-3rs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5326-2qs00-3rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ua00-5es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bf00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ra00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-0ba00-2gf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4ss00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-3rs00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-3rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1206-2bb00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1208-0ba00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bf00-2tb2",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-0ba00-2yf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-5fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5324-0ba00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1216-4bs00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bd00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1206-2bs00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2ts6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bb00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bb00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bb00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4bs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ua00-5es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5324-0ba00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4ss00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bb00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bd00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bd00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-2aa00-2yf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bf00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5326-2qs00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bb00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ra00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-2rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2as6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2ts6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-2aa00-2gf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2as6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bf00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bd00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bf00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bf00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5208-0ba00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5216-0ba00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bd00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bf00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bb00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2rs00-5ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5216-0ba00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bb00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bd00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bd00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bb00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bf00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bb00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2rs00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bd00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2bb00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5208-0ba00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr324wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr326-2c poe wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr328-4c wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-3g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017961"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44319"
      }
    ]
  },
  "cve": "CVE-2023-44319",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2023-86595",
            "impactScore": 6.9,
            "integrityImpact": "COMPLETE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:C/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 1.2,
            "id": "CVE-2023-44319",
            "impactScore": 3.6,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 4.9,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2023-44319",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-44319",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2023-44319",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-44319",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-86595",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017961"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44319"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44319"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions \u003c V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions \u003c V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions \u003c V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-2AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions). Affected devices use a weak checksum algorithm to protect the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that tricks a legitimate administrator to upload a modified configuration file to change the configuration of an affected device. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain vulnerabilities related to the use of weak hashes.Information may be tampered with. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-44319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017961"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86595"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44319"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-44319",
        "trust": 3.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-699386",
        "trust": 2.5
      },
      {
        "db": "SIEMENS",
        "id": "SSA-180704",
        "trust": 1.8
      },
      {
        "db": "SIEMENS",
        "id": "SSA-602936",
        "trust": 1.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-690517",
        "trust": 1.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-320-08",
        "trust": 0.9
      },
      {
        "db": "JVN",
        "id": "JVNVU93250330",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU98271228",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU91198149",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU92598492",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-165-12",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-046-09",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-348-14",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017961",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86595",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44319",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86595"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017961"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44319"
      }
    ]
  },
  "id": "VAR-202311-0441",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86595"
      }
    ],
    "trust": 1.2076912
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86595"
      }
    ]
  },
  "last_update_date": "2024-09-10T20:19:10.556000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Weak encryption vulnerabilities in multiple Siemens products",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/482176"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86595"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-328",
        "trust": 1.0
      },
      {
        "problemtype": "Using weak hashes (CWE-328) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017961"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44319"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-699386.pdf"
      },
      {
        "trust": 1.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
      },
      {
        "trust": 1.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-699386.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html"
      },
      {
        "trust": 0.9,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-08"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu92598492/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu98271228/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91198149/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu93250330/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-44319"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-14"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-09"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-12"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86595"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017961"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44319"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86595"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017961"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44319"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86595"
      },
      {
        "date": "2023-11-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44319"
      },
      {
        "date": "2024-01-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017961"
      },
      {
        "date": "2023-11-14T11:15:12.510000",
        "db": "NVD",
        "id": "CVE-2023-44319"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86595"
      },
      {
        "date": "2023-11-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44319"
      },
      {
        "date": "2024-06-17T05:34:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017961"
      },
      {
        "date": "2024-09-10T10:15:07.013000",
        "db": "NVD",
        "id": "CVE-2023-44319"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Weak hash usage vulnerability in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017961"
      }
    ],
    "trust": 0.8
  }
}

var-202311-0437
Vulnerability from variot

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-2AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions). Affected devices allow to change the password, but insufficiently check which password is to be changed. With this an authenticated attacker could, under certain conditions, be able to change the password of another, potential admin user allowing her to escalate her privileges. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain vulnerabilities related to asynchronous access to shared data within a multi-threaded context.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202311-0437",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "6gk5216-0ba00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-3rs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5326-2qs00-3rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ua00-5es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bf00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ra00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-0ba00-2gf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4ss00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-3rs00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-3rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1206-2bb00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1208-0ba00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bf00-2tb2",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-0ba00-2yf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-5fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5324-0ba00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1216-4bs00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bd00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1206-2bs00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2ts6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bb00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bb00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bb00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4bs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ua00-5es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5324-0ba00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4ss00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bb00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bd00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bd00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-2aa00-2yf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bf00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5326-2qs00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bb00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ra00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-2rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2as6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2ts6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-2aa00-2gf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2as6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bf00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bd00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bf00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bf00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5208-0ba00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5216-0ba00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bd00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bf00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bb00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2rs00-5ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5216-0ba00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bb00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bd00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bd00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bb00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bf00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bb00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2rs00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bd00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2bb00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5208-0ba00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr324wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr326-2c poe wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr328-4c wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-3g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86590"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017956"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44374"
      }
    ]
  },
  "cve": "CVE-2023-44374",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2023-86590",
            "impactScore": 6.9,
            "integrityImpact": "COMPLETE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:C/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2023-44374",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "productcert@siemens.com",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2023-44374",
            "impactScore": 3.6,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-44374",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-44374",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2023-44374",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-44374",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-86590",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86590"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017956"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44374"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44374"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions \u003c V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions \u003c V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-2AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions). Affected devices allow to change the password, but insufficiently check which password is to be changed. With this  an authenticated attacker could, under certain conditions, be able to change the password of another, potential admin user allowing her to escalate her privileges. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain vulnerabilities related to asynchronous access to shared data within a multi-threaded context.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-44374"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017956"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86590"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44374"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-44374",
        "trust": 3.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-699386",
        "trust": 2.5
      },
      {
        "db": "SIEMENS",
        "id": "SSA-180704",
        "trust": 1.8
      },
      {
        "db": "SIEMENS",
        "id": "SSA-690517",
        "trust": 1.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-320-08",
        "trust": 0.9
      },
      {
        "db": "JVN",
        "id": "JVNVU93250330",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU98271228",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU92598492",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-165-12",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-348-14",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017956",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86590",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44374",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86590"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44374"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017956"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44374"
      }
    ]
  },
  "id": "VAR-202311-0437",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86590"
      }
    ],
    "trust": 1.2076912
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86590"
      }
    ]
  },
  "last_update_date": "2024-09-10T21:07:22.336000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Asynchronous access vulnerability to shared data in multiple Siemens products in a multi-threaded context",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/482376"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86590"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-567",
        "trust": 1.0
      },
      {
        "problemtype": "Asynchronous access to shared data in a multithreaded context (CWE-567) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017956"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44374"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-699386.pdf"
      },
      {
        "trust": 1.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
      },
      {
        "trust": 1.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-699386.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html"
      },
      {
        "trust": 0.9,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-08"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu92598492/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu98271228/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu93250330/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-44374"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-14"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-12"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86590"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44374"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017956"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44374"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86590"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44374"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017956"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44374"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86590"
      },
      {
        "date": "2023-11-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44374"
      },
      {
        "date": "2024-01-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017956"
      },
      {
        "date": "2023-11-14T11:15:13.753000",
        "db": "NVD",
        "id": "CVE-2023-44374"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86590"
      },
      {
        "date": "2023-11-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44374"
      },
      {
        "date": "2024-06-17T05:37:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017956"
      },
      {
        "date": "2024-09-10T10:15:07.467000",
        "db": "NVD",
        "id": "CVE-2023-44374"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerabilities in multiple Siemens products involving asynchronous access to shared data within a multi-threaded context",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017956"
      }
    ],
    "trust": 0.8
  }
}

var-202311-0434
Vulnerability from variot

Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products such as firmware contain a resource exhaustion vulnerability.Service operation interruption (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs). A vulnerability has been identified in SCALANCE XB205-3 (SC, PN) (All versions < V4.5), SCALANCE XB205-3 (ST, E/IP) (All versions < V4.5), SCALANCE XB205-3 (ST, E/IP) (All versions < V4.5), SCALANCE XB205-3 (ST, PN) (All versions < V4.5), SCALANCE XB205-3LD (SC, E/IP) (All versions < V4.5), SCALANCE XB205-3LD (SC, PN) (All versions < V4.5), SCALANCE XB208 (E/IP) (All versions < V4.5), SCALANCE XB208 (PN) (All versions < V4.5), SCALANCE XB213-3 (SC, E/IP) (All versions < V4.5), SCALANCE XB213-3 (SC, PN) (All versions < V4.5), SCALANCE XB213-3 (ST, E/IP) (All versions < V4.5), SCALANCE XB213-3 (ST, PN) (All versions < V4.5), SCALANCE XB213-3LD (SC, E/IP) (All versions < V4.5), SCALANCE XB213-3LD (SC, PN) (All versions < V4.5), SCALANCE XB216 (E/IP) (All versions < V4.5), SCALANCE XB216 (PN) (All versions < V4.5), SCALANCE XC206-2 (SC) (All versions < V4.5), SCALANCE XC206-2 (ST/BFOC) (All versions < V4.5), SCALANCE XC206-2G PoE (All versions < V4.5), SCALANCE XC206-2G PoE (54 V DC) (All versions < V4.5), SCALANCE XC206-2G PoE EEC (54 V DC) (All versions < V4.5), SCALANCE XC206-2SFP (All versions < V4.5), SCALANCE XC206-2SFP EEC (All versions < V4.5), SCALANCE XC206-2SFP G (All versions < V4.5), SCALANCE XC206-2SFP G (EIP DEF.) (All versions < V4.5), SCALANCE XC206-2SFP G EEC (All versions < V4.5), SCALANCE XC208 (All versions < V4.5), SCALANCE XC208EEC (All versions < V4.5), SCALANCE XC208G (All versions < V4.5), SCALANCE XC208G (EIP def.) (All versions < V4.5), SCALANCE XC208G EEC (All versions < V4.5), SCALANCE XC208G PoE (All versions < V4.5), SCALANCE XC208G PoE (54 V DC) (All versions < V4.5), SCALANCE XC216 (All versions < V4.5), SCALANCE XC216-3G PoE (All versions < V4.5), SCALANCE XC216-3G PoE (54 V DC) (All versions < V4.5), SCALANCE XC216-4C (All versions < V4.5), SCALANCE XC216-4C G (All versions < V4.5), SCALANCE XC216-4C G (EIP Def.) (All versions < V4.5), SCALANCE XC216-4C G EEC (All versions < V4.5), SCALANCE XC216EEC (All versions < V4.5), SCALANCE XC224 (All versions < V4.5), SCALANCE XC224-4C G (All versions < V4.5), SCALANCE XC224-4C G (EIP Def.) (All versions < V4.5), SCALANCE XC224-4C G EEC (All versions < V4.5), SCALANCE XF204 (All versions < V4.5), SCALANCE XF204 DNA (All versions < V4.5), SCALANCE XF204-2BA (All versions < V4.5), SCALANCE XF204-2BA DNA (All versions < V4.5), SCALANCE XP208 (All versions < V4.5), SCALANCE XP208 (Ethernet/IP) (All versions < V4.5), SCALANCE XP208EEC (All versions < V4.5), SCALANCE XP208PoE EEC (All versions < V4.5), SCALANCE XP216 (All versions < V4.5), SCALANCE XP216 (Ethernet/IP) (All versions < V4.5), SCALANCE XP216EEC (All versions < V4.5), SCALANCE XP216POE EEC (All versions < V4.5), SCALANCE XR324WG (24 x FE, AC 230V) (All versions < V4.5), SCALANCE XR324WG (24 X FE, DC 24V) (All versions < V4.5), SCALANCE XR326-2C PoE WG (All versions < V4.5), SCALANCE XR326-2C PoE WG (without UL) (All versions < V4.5), SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (All versions < V4.5), SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (All versions < V4.5), SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (All versions < V4.5), SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (All versions < V4.5), SCALANCE XR328-4C WG (28xGE, AC 230V) (All versions < V4.5), SCALANCE XR328-4C WG (28xGE, DC 24V) (All versions < V4.5), SIPLUS NET SCALANCE XC206-2 (All versions < V4.5), SIPLUS NET SCALANCE XC206-2SFP (All versions < V4.5), SIPLUS NET SCALANCE XC208 (All versions < V4.5), SIPLUS NET SCALANCE XC216-4C (All versions < V4.5)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202311-0434",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "6gk5208-0ra00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ra00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5324-0ba00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-2rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-5fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bf00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bb00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2as6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bb00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-0ba00-2yf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bb00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bf00-2tb2",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bb00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bf00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-2aa00-2yf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5324-0ba00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4bs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bf00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2ts6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-0ba00-2gf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4ss00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ua00-5es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bb00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1206-2bs00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1208-0ba00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ua00-5es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bd00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bd00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2as6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-2aa00-2gf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5326-2qs00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5326-2qs00-3rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-3rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-3rs00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4ss00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1206-2bb00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bd00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1216-4bs00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2ts6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-3rs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bb00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bb00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bd00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5216-0ba00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bd00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5216-0ba00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bf00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bf00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2rs00-5ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5208-0ba00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2bd00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bb00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bd00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bd00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2rs00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5208-0ba00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bb00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bf00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bf00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bb00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr324wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr326-2c poe wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr328-4c wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-3g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017959"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44321"
      }
    ]
  },
  "cve": "CVE-2023-44321",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2023-86593",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2023-44321",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "productcert@siemens.com",
            "availabilityImpact": "LOW",
            "baseScore": 2.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 1.2,
            "id": "CVE-2023-44321",
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2023-44321",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-44321",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2023-44321",
            "trust": 1.0,
            "value": "Medium"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-44321",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-86593",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017959"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44321"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44321"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products such as firmware contain a resource exhaustion vulnerability.Service operation interruption (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs). A vulnerability has been identified in SCALANCE XB205-3 (SC, PN) (All versions \u003c V4.5), SCALANCE XB205-3 (ST, E/IP) (All versions \u003c V4.5), SCALANCE XB205-3 (ST, E/IP) (All versions \u003c V4.5), SCALANCE XB205-3 (ST, PN) (All versions \u003c V4.5), SCALANCE XB205-3LD (SC, E/IP) (All versions \u003c V4.5), SCALANCE XB205-3LD (SC, PN) (All versions \u003c V4.5), SCALANCE XB208 (E/IP) (All versions \u003c V4.5), SCALANCE XB208 (PN) (All versions \u003c V4.5), SCALANCE XB213-3 (SC, E/IP) (All versions \u003c V4.5), SCALANCE XB213-3 (SC, PN) (All versions \u003c V4.5), SCALANCE XB213-3 (ST, E/IP) (All versions \u003c V4.5), SCALANCE XB213-3 (ST, PN) (All versions \u003c V4.5), SCALANCE XB213-3LD (SC, E/IP) (All versions \u003c V4.5), SCALANCE XB213-3LD (SC, PN) (All versions \u003c V4.5), SCALANCE XB216 (E/IP) (All versions \u003c V4.5), SCALANCE XB216 (PN) (All versions \u003c V4.5), SCALANCE XC206-2 (SC) (All versions \u003c V4.5), SCALANCE XC206-2 (ST/BFOC) (All versions \u003c V4.5), SCALANCE XC206-2G PoE (All versions \u003c V4.5), SCALANCE XC206-2G PoE (54 V DC) (All versions \u003c V4.5), SCALANCE XC206-2G PoE EEC (54 V DC) (All versions \u003c V4.5), SCALANCE XC206-2SFP (All versions \u003c V4.5), SCALANCE XC206-2SFP EEC (All versions \u003c V4.5), SCALANCE XC206-2SFP G (All versions \u003c V4.5), SCALANCE XC206-2SFP G (EIP DEF.) (All versions \u003c V4.5), SCALANCE XC206-2SFP G EEC (All versions \u003c V4.5), SCALANCE XC208 (All versions \u003c V4.5), SCALANCE XC208EEC (All versions \u003c V4.5), SCALANCE XC208G (All versions \u003c V4.5), SCALANCE XC208G (EIP def.) (All versions \u003c V4.5), SCALANCE XC208G EEC (All versions \u003c V4.5), SCALANCE XC208G PoE (All versions \u003c V4.5), SCALANCE XC208G PoE (54 V DC) (All versions \u003c V4.5), SCALANCE XC216 (All versions \u003c V4.5), SCALANCE XC216-3G PoE (All versions \u003c V4.5), SCALANCE XC216-3G PoE (54 V DC) (All versions \u003c V4.5), SCALANCE XC216-4C (All versions \u003c V4.5), SCALANCE XC216-4C G (All versions \u003c V4.5), SCALANCE XC216-4C G (EIP Def.) (All versions \u003c V4.5), SCALANCE XC216-4C G EEC (All versions \u003c V4.5), SCALANCE XC216EEC (All versions \u003c V4.5), SCALANCE XC224 (All versions \u003c V4.5), SCALANCE XC224-4C G (All versions \u003c V4.5), SCALANCE XC224-4C G (EIP Def.) (All versions \u003c V4.5), SCALANCE XC224-4C G EEC (All versions \u003c V4.5), SCALANCE XF204 (All versions \u003c V4.5), SCALANCE XF204 DNA (All versions \u003c V4.5), SCALANCE XF204-2BA (All versions \u003c V4.5), SCALANCE XF204-2BA DNA (All versions \u003c V4.5), SCALANCE XP208 (All versions \u003c V4.5), SCALANCE XP208 (Ethernet/IP) (All versions \u003c V4.5), SCALANCE XP208EEC (All versions \u003c V4.5), SCALANCE XP208PoE EEC (All versions \u003c V4.5), SCALANCE XP216 (All versions \u003c V4.5), SCALANCE XP216 (Ethernet/IP) (All versions \u003c V4.5), SCALANCE XP216EEC (All versions \u003c V4.5), SCALANCE XP216POE EEC (All versions \u003c V4.5), SCALANCE XR324WG (24 x FE, AC 230V) (All versions \u003c V4.5), SCALANCE XR324WG (24 X FE, DC 24V) (All versions \u003c V4.5), SCALANCE XR326-2C PoE WG (All versions \u003c V4.5), SCALANCE XR326-2C PoE WG (without UL) (All versions \u003c V4.5), SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (All versions \u003c V4.5), SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (All versions \u003c V4.5), SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (All versions \u003c V4.5), SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (All versions \u003c V4.5), SCALANCE XR328-4C WG (28xGE, AC 230V) (All versions \u003c V4.5), SCALANCE XR328-4C WG (28xGE, DC 24V) (All versions \u003c V4.5), SIPLUS NET SCALANCE XC206-2 (All versions \u003c V4.5), SIPLUS NET SCALANCE XC206-2SFP (All versions \u003c V4.5), SIPLUS NET SCALANCE XC208 (All versions \u003c V4.5), SIPLUS NET SCALANCE XC216-4C (All versions \u003c V4.5)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-44321"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017959"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44321"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-44321",
        "trust": 3.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-699386",
        "trust": 2.5
      },
      {
        "db": "SIEMENS",
        "id": "SSA-180704",
        "trust": 1.8
      },
      {
        "db": "SIEMENS",
        "id": "SSA-087301",
        "trust": 1.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-602936",
        "trust": 1.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-353002",
        "trust": 1.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-320-08",
        "trust": 0.9
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-228-01",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-348-14",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-074-08",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-046-09",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU99084687",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU91198149",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU98271228",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU93656033",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU92598492",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017959",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86593",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44321",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44321"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017959"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44321"
      }
    ]
  },
  "id": "VAR-202311-0434",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86593"
      }
    ],
    "trust": 1.2076911999999997
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86593"
      }
    ]
  },
  "last_update_date": "2024-08-21T21:42:06.014000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Uncontrolled resource consumption vulnerability in multiple Siemens products",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/482271"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86593"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-400",
        "trust": 1.0
      },
      {
        "problemtype": "Resource exhaustion (CWE-400) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017959"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44321"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-699386.pdf"
      },
      {
        "trust": 1.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
      },
      {
        "trust": 1.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-699386.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-087301.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-353002.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html"
      },
      {
        "trust": 0.9,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-08"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu92598492/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu98271228/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91198149/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu93656033/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu99084687/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-44321"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-14"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-09"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-08"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-228-01"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44321"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017959"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44321"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44321"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017959"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44321"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86593"
      },
      {
        "date": "2023-11-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44321"
      },
      {
        "date": "2024-01-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017959"
      },
      {
        "date": "2023-11-14T11:15:12.973000",
        "db": "NVD",
        "id": "CVE-2023-44321"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86593"
      },
      {
        "date": "2023-11-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44321"
      },
      {
        "date": "2024-08-19T05:36:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017959"
      },
      {
        "date": "2024-08-13T08:15:07.533000",
        "db": "NVD",
        "id": "CVE-2023-44321"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Resource Exhaustion Vulnerability in Multiple Siemens Products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017959"
      }
    ],
    "trust": 0.8
  }
}

var-202101-0486
Vulnerability from variot

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0486",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt siplus net",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf201-3p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf202-2p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x308-2m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x201-3pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x202-2irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x320-3ldfe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf206-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2ba irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "siplus net scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x204irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x201-3pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x-200irt switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance switch family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x-200"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28391"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens ProductCERT reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2020-28391",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2020-28391",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 9.4,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-02593",
            "impactScore": 9.2,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.2,
            "id": "CVE-2020-28391",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "High",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 5.9,
            "baseSeverity": "Medium",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2020-28391",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-28391",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2020-28391",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-02593",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-834",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-28391",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28391"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-28391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28391"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-28391",
        "trust": 3.1
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-012-02",
        "trust": 2.5
      },
      {
        "db": "SIEMENS",
        "id": "SSA-274900",
        "trust": 2.3
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0124",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28391",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28391"
      }
    ]
  },
  "id": "VAR-202101-0486",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      }
    ],
    "trust": 1.2641418511111109
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      }
    ]
  },
  "last_update_date": "2024-11-23T20:47:39.963000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-274900",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
      },
      {
        "title": "Patch for Scalance X Products hard-coded encryption key vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/244015"
      },
      {
        "title": "Multiple Siemens Product security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=139506"
      },
      {
        "title": "Siemens Security Advisories: Siemens Security Advisory",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=16f5b7ec974eee0b50172f47db7b7ec5"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-798",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-321",
        "trust": 1.0
      },
      {
        "problemtype": "Using hardcoded credentials (CWE-798) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28391"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02"
      },
      {
        "trust": 2.3,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28391"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0124/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/321.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-012-02"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28391"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28391"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-01-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "date": "2021-01-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-28391"
      },
      {
        "date": "2021-10-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "date": "2021-01-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      },
      {
        "date": "2021-01-12T21:15:18.120000",
        "db": "NVD",
        "id": "CVE-2020-28391"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-02-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "date": "2022-12-13T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-28391"
      },
      {
        "date": "2021-10-01T08:04:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "date": "2022-12-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      },
      {
        "date": "2024-11-21T05:22:42.433000",
        "db": "NVD",
        "id": "CVE-2020-28391"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SCALANCE\u00a0X-200\u00a0 and \u00a0SCALANCE\u00a0X-200IRT\u00a0 Vulnerability in using hard-coded credentials in switch families",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "trust management problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      }
    ],
    "trust": 0.6
  }
}

var-202212-1134
Vulnerability from variot

Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain vulnerabilities related to storing passwords in a recoverable format.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202212-1134",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xr552-12m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wam766-1 ecc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xm416-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr326-2c poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc642-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr328-4c wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w734-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "siplus net scalance xc206-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc632-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance w788-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "siplus net scalance xc208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w738-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr524-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance s615 eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance m874-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc646-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "ruggedcom rm1224 lte\\ eu",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2bca dna",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc224",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w786-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w748-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w786-2 sfp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "siplus net scalance xc206-2sfp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wum766-1 6ghz",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m826-2 shdsl-router",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w778-1 m12 eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr528-6m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m876-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr326-2c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w778-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w788-2 m12 eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb213-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wum766-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp216eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc636-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance w788-2 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance mum853-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "siplus net scalance xc216-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m804pb",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w774-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w1788-2ia m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr526-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w721-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance mum856-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ruggedcom rm1224 lte\\ nam",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m874-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2ba",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w1788-2 eec m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb205-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w786-2 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc622-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance w761-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-3g poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xf204 dna",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance s615",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance wum763-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr324wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wam763-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xm408-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w774-1 m12 eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wam766-1 6ghz",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w786-2ia rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m812-1 adsl-router",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance wam766-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w774-1 m12 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xm408-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m816-1 adsl-router",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w788-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp208eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w1788-2 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w722-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w1748-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208 poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m876-4",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w1788-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc626-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance xc216eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208 eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xf204",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance s615 eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m812-1 adsl-router",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m876-4",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance s615",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "ruggedcom rm1224 lte eu",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-622-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-636-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "ruggedcom rm1224 lte nam",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m816-1 adsl-router",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance mum856-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m876-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc626-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m874-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-642-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance mum853-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m826-2 shdsl-router",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m804pb",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-646-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-632-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m874-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023552"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46142"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3090"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-46142",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "author": "productcert@siemens.com",
            "availabilityImpact": "LOW",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 0.9,
            "id": "CVE-2022-46142",
            "impactScore": 4.7,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 0.9,
            "id": "CVE-2022-46142",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Physical",
            "author": "OTHER",
            "availabilityImpact": "Low",
            "baseScore": 5.7,
            "baseSeverity": "Medium",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2022-023552",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2022-46142",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-46142",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2022-023552",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202212-3090",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023552"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3090"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46142"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46142"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain vulnerabilities related to storing passwords in a recoverable format.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-46142"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023552"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-46142",
        "trust": 3.2
      },
      {
        "db": "SIEMENS",
        "id": "SSA-413565",
        "trust": 2.4
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-349-04",
        "trust": 1.4
      },
      {
        "db": "JVN",
        "id": "JVNVU91561630",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023552",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3090",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023552"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3090"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46142"
      }
    ]
  },
  "id": "VAR-202212-1134",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.6398166875
  },
  "last_update_date": "2024-08-14T12:13:17.100000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Siemens part of the product Security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=218339"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3090"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-257",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-522",
        "trust": 1.0
      },
      {
        "problemtype": "Password storage in recoverable form (CWE-257) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023552"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46142"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91561630/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-46142"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-04"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-349-04"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-46142/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023552"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3090"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46142"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023552"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3090"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46142"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-023552"
      },
      {
        "date": "2022-12-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202212-3090"
      },
      {
        "date": "2022-12-13T16:15:25.067000",
        "db": "NVD",
        "id": "CVE-2022-46142"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-29T03:03:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-023552"
      },
      {
        "date": "2023-03-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202212-3090"
      },
      {
        "date": "2023-03-14T10:15:24.137000",
        "db": "NVD",
        "id": "CVE-2022-46142"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Recoverable password storage vulnerability in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023552"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3090"
      }
    ],
    "trust": 0.6
  }
}

var-202101-0139
Vulnerability from variot

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily. SCALANCE X-200 and SCALANCE X-200IRT An out-of-bounds write vulnerability exists in the switch family.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0139",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt siplus net",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf201-3p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf202-2p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x308-2m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x201-3pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x202-2irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x320-3ldfe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf206-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2ba irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "siplus net scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x204irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x201-3pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x-200irt switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance switch family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x-200"
      },
      {
        "model": "scalance switch family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x-300x408\u003cv4.1.0"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2020-15800",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2020-15800",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-02595",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-15800",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2020-15800",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-15800",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2020-15800",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-02595",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-915",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily. SCALANCE X-200 and SCALANCE X-200IRT An out-of-bounds write vulnerability exists in the switch family.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-15800",
        "trust": 3.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-139628",
        "trust": 2.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-012-05",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0127",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "id": "VAR-202101-0139",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      }
    ],
    "trust": 1.2641418511111109
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      }
    ]
  },
  "last_update_date": "2024-11-23T20:33:26.845000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-139628",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf"
      },
      {
        "title": "Patch for Scalance X Products heap buffer overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/244021"
      },
      {
        "title": "Siemens SCALANCE X-200IRT Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=138843"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-122",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-15800"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-05"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0127/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-01-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "date": "2021-10-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "date": "2021-01-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      },
      {
        "date": "2021-01-12T21:15:16.480000",
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-02-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "date": "2021-10-01T08:52:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "date": "2021-09-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      },
      {
        "date": "2024-11-21T05:06:12.450000",
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SCALANCE\u00a0X-200\u00a0 and \u00a0SCALANCE\u00a0X-200IRT\u00a0 Out-of-bounds write vulnerability in switch family",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ],
    "trust": 0.6
  }
}

var-202101-0304
Vulnerability from variot

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore. SCALANCE X-200 and SCALANCE X-200IRT An out-of-bounds write vulnerability exists in the switch family.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0304",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt siplus net",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf201-3p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf202-2p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x308-2m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x201-3pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x202-2irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x320-3ldfe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf206-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2ba irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "siplus net scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x204irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x201-3pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x-200irt switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance switch family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x-200"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25226"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2020-25226",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-25226",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-02594",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-25226",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2020-25226",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-25226",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2020-25226",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-02594",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-917",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25226"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore. SCALANCE X-200 and SCALANCE X-200IRT An out-of-bounds write vulnerability exists in the switch family.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-25226"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-25226",
        "trust": 3.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-139628",
        "trust": 2.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-012-05",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0127",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25226"
      }
    ]
  },
  "id": "VAR-202101-0304",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      }
    ],
    "trust": 1.264141851111111
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      }
    ]
  },
  "last_update_date": "2024-11-23T19:30:05.728000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-139628",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf"
      },
      {
        "title": "Patch for Scalance X Products heap buffer overflow vulnerability (CNVD-2021-02594)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/244018"
      },
      {
        "title": "Multiple Siemens Product Buffer Error Vulnerability Fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=139392"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-122",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25226"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-25226"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-05"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0127/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25226"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25226"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-01-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "date": "2021-10-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "date": "2021-01-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      },
      {
        "date": "2021-01-12T21:15:16.543000",
        "db": "NVD",
        "id": "CVE-2020-25226"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-02-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "date": "2021-10-01T08:45:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "date": "2021-09-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      },
      {
        "date": "2024-11-21T05:17:42.257000",
        "db": "NVD",
        "id": "CVE-2020-25226"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SCALANCE\u00a0X-200\u00a0 and \u00a0SCALANCE\u00a0X-200IRT\u00a0 Out-of-bounds write vulnerability in switch family",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      }
    ],
    "trust": 0.6
  }
}

var-202208-0610
Vulnerability from variot

Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack. SCALANCE M-800 firmware, SCALANCE S615 firmware, scalance w700 ieee 802.11ax Multiple Siemens products, including firmware, contain vulnerabilities related to limited or unthrottled resource allocation.Service operation interruption (DoS) It may be in a state. The SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 industrial routers are used for secure remote access to plants via mobile networks (e.g. GPRS or UMTS) and have integrated security functions for firewalls to prevent unauthorized access, as well as VPN to Secure data transmission. SCALANCE SC-600 devices (SC622-2C, SC632-2C, SC636-2C, SC642-2C, SC646-2C) are used to protect trusted industrial networks from untrusted network attacks. They allow filtering incoming and outgoing network connections in different ways. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. SCALANCE W-700 products are wireless communication devices based on the IEEE 802.11ax standard. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202208-0610",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xc206-2sfp g",
        "scope": null,
        "trust": 1.6,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xr552-12m 2hr2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224-4c g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w700 ieee 802.11ac",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr524-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb205-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324-4m poe ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr524-8c l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216-4c g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr528-6m l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324-12m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc-200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr528-6m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2ba irt",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm400",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr-300eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr500",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208 \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w700 ieee 802.11n",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb213-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm408-8c l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr552-12m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm416-4c l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr552",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr-300",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr328-4c wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr526-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb-200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp216 \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf-200ba",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr528-6m 2hr2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm408-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr-300poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr552-12m 2hr2 l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w700 ieee 802.11ax",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm408-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm408-4c l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr326-2c poe wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr552-12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324-12m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr524",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp-200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance s615",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr528-6m 2hr2 l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp216eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324-4m eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr528",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance m-800",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm416-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr526-8c l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr526",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr-300wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb205-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc206-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb-200",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb216",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance w700 ieee 802.11ax",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc-200",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m-800",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb213-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb213-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance w700 ieee 802.11n",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance w700 ieee 802.11ac",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb205-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance s615",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb208",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m-800 s615",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "/"
      },
      {
        "model": "scalance w-700 ieee 802.11ax family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w-700 ieee 802.11n family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w-1700 ieee 802.11ac family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb-200 switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc-200 switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xf-200ba switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xm-400 family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp-200 switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr-300wg switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr-500 family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56475"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014932"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36324"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens has reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2714"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-36324",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-56475",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-36324",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2022-36324",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-36324",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2022-36324",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-36324",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-56475",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202208-2714",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56475"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014932"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2714"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36324"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36324"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack. SCALANCE M-800 firmware, SCALANCE S615 firmware, scalance w700 ieee 802.11ax Multiple Siemens products, including firmware, contain vulnerabilities related to limited or unthrottled resource allocation.Service operation interruption (DoS) It may be in a state. The SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 industrial routers are used for secure remote access to plants via mobile networks (e.g. GPRS or UMTS) and have integrated security functions for firewalls to prevent unauthorized access, as well as VPN to Secure data transmission. SCALANCE SC-600 devices (SC622-2C, SC632-2C, SC636-2C, SC642-2C, SC646-2C) are used to protect trusted industrial networks from untrusted network attacks. They allow filtering incoming and outgoing network connections in different ways. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. SCALANCE W-700 products are wireless communication devices based on the IEEE 802.11ax standard. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-36324"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014932"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-56475"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36324"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-36324",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-710008",
        "trust": 3.1
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-223-07",
        "trust": 1.5
      },
      {
        "db": "JVN",
        "id": "JVNVU90767165",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014932",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-56475",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2022.4032",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2714",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36324",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56475"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36324"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014932"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2714"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36324"
      }
    ]
  },
  "id": "VAR-202208-0610",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56475"
      }
    ],
    "trust": 1.2363483332142855
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56475"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:17:48.847000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Unknown Vulnerability in Siemens SCALANCE Products",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/343621"
      },
      {
        "title": "Multiple Siemens SCALANCE Product security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=207453"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56475"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2714"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-770",
        "trust": 1.0
      },
      {
        "problemtype": "Allocation of resources without limits or throttling (CWE-770) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014932"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36324"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu90767165/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-36324"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-223-07"
      },
      {
        "trust": 0.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2022.4032"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-36324/"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-223-07"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/770.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-07"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56475"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36324"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014932"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2714"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36324"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56475"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36324"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014932"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2714"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36324"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-08-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-56475"
      },
      {
        "date": "2022-08-10T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-36324"
      },
      {
        "date": "2023-09-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-014932"
      },
      {
        "date": "2022-08-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-2714"
      },
      {
        "date": "2022-08-10T12:15:12.930000",
        "db": "NVD",
        "id": "CVE-2022-36324"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-08-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-56475"
      },
      {
        "date": "2022-08-10T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-36324"
      },
      {
        "date": "2023-09-22T08:25:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-014932"
      },
      {
        "date": "2022-09-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-2714"
      },
      {
        "date": "2023-02-23T16:19:42.137000",
        "db": "NVD",
        "id": "CVE-2022-36324"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2714"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerability in limiting or non-slotting resource allocation in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014932"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2714"
      }
    ],
    "trust": 0.6
  }
}

var-202311-0438
Vulnerability from variot

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V7.2.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V7.2.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V7.2.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V7.2.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V7.2.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V7.2.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V7.2.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V7.2.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V7.2.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V7.2.2). Affected devices do not properly validate the authentication when performing certain modifications in the web interface allowing an authenticated attacker to influence the user interface configured by an administrator. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain vulnerabilities related to direct request submission.Information may be tampered with. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs).

Several Siemens products have forced browsing vulnerabilities that attackers can exploit to affect the user interface configured by administrators

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202311-0438",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "6gk5208-0ra00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ra00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5324-0ba00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-2rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-5fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bf00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bb00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2as6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bb00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-0ba00-2yf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bb00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bf00-2tb2",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bb00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bf00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-2aa00-2yf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5324-0ba00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4bs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bf00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2ts6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-0ba00-2gf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4ss00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ua00-5es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bb00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1206-2bs00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1208-0ba00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ua00-5es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bd00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bd00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2as6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-2aa00-2gf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5326-2qs00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5326-2qs00-3rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-3rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-3rs00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4ss00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1206-2bb00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bd00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1216-4bs00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2ts6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-3rs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2bb00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bd00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bf00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5208-0ba00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bb00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2bd00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2rs00-5ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5216-0ba00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bd00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bf00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bd00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5216-0ba00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bb00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5208-0ba00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bf00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bb00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bb00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bf00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2rs00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr324wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr326-2c poe wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr328-4c wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-3g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86594"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017960"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44320"
      }
    ]
  },
  "cve": "CVE-2023-44320",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2023-86594",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2023-44320",
            "impactScore": 1.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 4.3,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2023-44320",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-44320",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2023-44320",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-44320",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-86594",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86594"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017960"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44320"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44320"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V7.2.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V7.2.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions \u003c V7.2.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V7.2.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V7.2.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V7.2.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V7.2.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V7.2.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V7.2.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V7.2.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions \u003c V7.2.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions \u003c V7.2.2). Affected devices do not properly validate the authentication when performing certain modifications in the web interface allowing an authenticated attacker to influence the user interface configured by an administrator. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain vulnerabilities related to direct request submission.Information may be tampered with. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs). \n\r\n\r\nSeveral Siemens products have forced browsing vulnerabilities that attackers can exploit to affect the user interface configured by administrators",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-44320"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017960"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86594"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44320"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-44320",
        "trust": 3.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-699386",
        "trust": 2.5
      },
      {
        "db": "SIEMENS",
        "id": "SSA-180704",
        "trust": 1.8
      },
      {
        "db": "SIEMENS",
        "id": "SSA-602936",
        "trust": 1.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-068047",
        "trust": 1.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-320-08",
        "trust": 0.9
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-348-14",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-046-09",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU98271228",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU91198149",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU92598492",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017960",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86594",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44320",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86594"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44320"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017960"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44320"
      }
    ]
  },
  "id": "VAR-202311-0438",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86594"
      }
    ],
    "trust": 1.2076911999999997
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86594"
      }
    ]
  },
  "last_update_date": "2024-08-15T10:09:32.256000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Forced browsing vulnerabilities in multiple Siemens products",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/482266"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86594"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-425",
        "trust": 1.0
      },
      {
        "problemtype": "Direct request submission (CWE-425) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017960"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44320"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-699386.pdf"
      },
      {
        "trust": 1.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
      },
      {
        "trust": 1.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-699386.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-068047.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html"
      },
      {
        "trust": 0.9,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-08"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu92598492/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu98271228/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91198149/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-44320"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-14"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-09"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86594"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44320"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017960"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44320"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86594"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44320"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017960"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44320"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86594"
      },
      {
        "date": "2023-11-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44320"
      },
      {
        "date": "2024-01-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017960"
      },
      {
        "date": "2023-11-14T11:15:12.757000",
        "db": "NVD",
        "id": "CVE-2023-44320"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86594"
      },
      {
        "date": "2023-11-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44320"
      },
      {
        "date": "2024-02-19T06:53:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017960"
      },
      {
        "date": "2024-08-13T08:15:07.287000",
        "db": "NVD",
        "id": "CVE-2023-44320"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Direct request vulnerability in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017960"
      }
    ],
    "trust": 0.8
  }
}

var-202311-0435
Vulnerability from variot

Affected devices use a hardcoded key to obfuscate the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that obtains a configuration backup to extract configuration information from the exported file. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain vulnerabilities related to the use of hard-coded encryption keys.Information may be obtained. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs). A vulnerability has been identified in SCALANCE XB205-3 (SC, PN) (All versions < V4.5), SCALANCE XB205-3 (ST, E/IP) (All versions < V4.5), SCALANCE XB205-3 (ST, E/IP) (All versions < V4.5), SCALANCE XB205-3 (ST, PN) (All versions < V4.5), SCALANCE XB205-3LD (SC, E/IP) (All versions < V4.5), SCALANCE XB205-3LD (SC, PN) (All versions < V4.5), SCALANCE XB208 (E/IP) (All versions < V4.5), SCALANCE XB208 (PN) (All versions < V4.5), SCALANCE XB213-3 (SC, E/IP) (All versions < V4.5), SCALANCE XB213-3 (SC, PN) (All versions < V4.5), SCALANCE XB213-3 (ST, E/IP) (All versions < V4.5), SCALANCE XB213-3 (ST, PN) (All versions < V4.5), SCALANCE XB213-3LD (SC, E/IP) (All versions < V4.5), SCALANCE XB213-3LD (SC, PN) (All versions < V4.5), SCALANCE XB216 (E/IP) (All versions < V4.5), SCALANCE XB216 (PN) (All versions < V4.5), SCALANCE XC206-2 (SC) (All versions < V4.5), SCALANCE XC206-2 (ST/BFOC) (All versions < V4.5), SCALANCE XC206-2G PoE (All versions < V4.5), SCALANCE XC206-2G PoE (54 V DC) (All versions < V4.5), SCALANCE XC206-2G PoE EEC (54 V DC) (All versions < V4.5), SCALANCE XC206-2SFP (All versions < V4.5), SCALANCE XC206-2SFP EEC (All versions < V4.5), SCALANCE XC206-2SFP G (All versions < V4.5), SCALANCE XC206-2SFP G (EIP DEF.) (All versions < V4.5), SCALANCE XC206-2SFP G EEC (All versions < V4.5), SCALANCE XC208 (All versions < V4.5), SCALANCE XC208EEC (All versions < V4.5), SCALANCE XC208G (All versions < V4.5), SCALANCE XC208G (EIP def.) (All versions < V4.5), SCALANCE XC208G EEC (All versions < V4.5), SCALANCE XC208G PoE (All versions < V4.5), SCALANCE XC208G PoE (54 V DC) (All versions < V4.5), SCALANCE XC216 (All versions < V4.5), SCALANCE XC216-3G PoE (All versions < V4.5), SCALANCE XC216-3G PoE (54 V DC) (All versions < V4.5), SCALANCE XC216-4C (All versions < V4.5), SCALANCE XC216-4C G (All versions < V4.5), SCALANCE XC216-4C G (EIP Def.) (All versions < V4.5), SCALANCE XC216-4C G EEC (All versions < V4.5), SCALANCE XC216EEC (All versions < V4.5), SCALANCE XC224 (All versions < V4.5), SCALANCE XC224-4C G (All versions < V4.5), SCALANCE XC224-4C G (EIP Def.) (All versions < V4.5), SCALANCE XC224-4C G EEC (All versions < V4.5), SCALANCE XF204 (All versions < V4.5), SCALANCE XF204 DNA (All versions < V4.5), SCALANCE XF204-2BA (All versions < V4.5), SCALANCE XF204-2BA DNA (All versions < V4.5), SCALANCE XP208 (All versions < V4.5), SCALANCE XP208 (Ethernet/IP) (All versions < V4.5), SCALANCE XP208EEC (All versions < V4.5), SCALANCE XP208PoE EEC (All versions < V4.5), SCALANCE XP216 (All versions < V4.5), SCALANCE XP216 (Ethernet/IP) (All versions < V4.5), SCALANCE XP216EEC (All versions < V4.5), SCALANCE XP216POE EEC (All versions < V4.5), SCALANCE XR324WG (24 x FE, AC 230V) (All versions < V4.5), SCALANCE XR324WG (24 X FE, DC 24V) (All versions < V4.5), SCALANCE XR326-2C PoE WG (All versions < V4.5), SCALANCE XR326-2C PoE WG (without UL) (All versions < V4.5), SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (All versions < V4.5), SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (All versions < V4.5), SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (All versions < V4.5), SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (All versions < V4.5), SCALANCE XR328-4C WG (28xGE, AC 230V) (All versions < V4.5), SCALANCE XR328-4C WG (28xGE, DC 24V) (All versions < V4.5), SIPLUS NET SCALANCE XC206-2 (All versions < V4.5), SIPLUS NET SCALANCE XC206-2SFP (All versions < V4.5), SIPLUS NET SCALANCE XC208 (All versions < V4.5), SIPLUS NET SCALANCE XC216-4C (All versions < V4.5)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202311-0435",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "6gk5205-3bf00-2tb2",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-5fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2ts6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5324-0ba00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-3rs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1206-2bb00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bd00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5326-2qs00-3rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bb00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1206-2bs00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4ss00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5324-0ba00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-0ba00-2gf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-2aa00-2gf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2as6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1208-0ba00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bb00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bf00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5326-2qs00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bf00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4bs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ra00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2rs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ha00-2ts6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ba00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ha00-2as6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-3rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bd00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bd00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bf00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-2rr3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6ag1216-4bs00-7ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bb00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ba00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-2aa00-2yf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4fs00-2ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ga00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5328-4ss00-3ar3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ua00-5es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bd00-2tb2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5205-3bb00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5213-3bb00-2ab2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5208-0ra00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-3rs00-5ac2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5224-4gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-4gs00-2tc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2gs00-2fc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5216-0ua00-5es6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5204-0ba00-2yf2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "6gk5206-2bd00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bf00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bf00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5208-0ba00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5216-0ba00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bd00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bf00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bb00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2rs00-5ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5216-0ba00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bb00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bd00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bd00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5213-3bb00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bf00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bb00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2rs00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5205-3bd00-2ab2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5206-2bb00-2ac2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk5208-0ba00-2tb2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr324wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr326-2c poe wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr328-4c wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-3g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017962"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44318"
      }
    ]
  },
  "cve": "CVE-2023-44318",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2023-86596",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.2,
            "id": "CVE-2023-44318",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 4.9,
            "baseSeverity": "Medium",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-44318",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "High",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-44318",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2023-44318",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-44318",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-86596",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017962"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44318"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44318"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Affected devices use a hardcoded key to obfuscate the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that obtains a configuration backup to extract configuration information from the exported file. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain vulnerabilities related to the use of hard-coded encryption keys.Information may be obtained. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs). A vulnerability has been identified in SCALANCE XB205-3 (SC, PN) (All versions \u003c V4.5), SCALANCE XB205-3 (ST, E/IP) (All versions \u003c V4.5), SCALANCE XB205-3 (ST, E/IP) (All versions \u003c V4.5), SCALANCE XB205-3 (ST, PN) (All versions \u003c V4.5), SCALANCE XB205-3LD (SC, E/IP) (All versions \u003c V4.5), SCALANCE XB205-3LD (SC, PN) (All versions \u003c V4.5), SCALANCE XB208 (E/IP) (All versions \u003c V4.5), SCALANCE XB208 (PN) (All versions \u003c V4.5), SCALANCE XB213-3 (SC, E/IP) (All versions \u003c V4.5), SCALANCE XB213-3 (SC, PN) (All versions \u003c V4.5), SCALANCE XB213-3 (ST, E/IP) (All versions \u003c V4.5), SCALANCE XB213-3 (ST, PN) (All versions \u003c V4.5), SCALANCE XB213-3LD (SC, E/IP) (All versions \u003c V4.5), SCALANCE XB213-3LD (SC, PN) (All versions \u003c V4.5), SCALANCE XB216 (E/IP) (All versions \u003c V4.5), SCALANCE XB216 (PN) (All versions \u003c V4.5), SCALANCE XC206-2 (SC) (All versions \u003c V4.5), SCALANCE XC206-2 (ST/BFOC) (All versions \u003c V4.5), SCALANCE XC206-2G PoE (All versions \u003c V4.5), SCALANCE XC206-2G PoE (54 V DC) (All versions \u003c V4.5), SCALANCE XC206-2G PoE EEC (54 V DC) (All versions \u003c V4.5), SCALANCE XC206-2SFP (All versions \u003c V4.5), SCALANCE XC206-2SFP EEC (All versions \u003c V4.5), SCALANCE XC206-2SFP G (All versions \u003c V4.5), SCALANCE XC206-2SFP G (EIP DEF.) (All versions \u003c V4.5), SCALANCE XC206-2SFP G EEC (All versions \u003c V4.5), SCALANCE XC208 (All versions \u003c V4.5), SCALANCE XC208EEC (All versions \u003c V4.5), SCALANCE XC208G (All versions \u003c V4.5), SCALANCE XC208G (EIP def.) (All versions \u003c V4.5), SCALANCE XC208G EEC (All versions \u003c V4.5), SCALANCE XC208G PoE (All versions \u003c V4.5), SCALANCE XC208G PoE (54 V DC) (All versions \u003c V4.5), SCALANCE XC216 (All versions \u003c V4.5), SCALANCE XC216-3G PoE (All versions \u003c V4.5), SCALANCE XC216-3G PoE (54 V DC) (All versions \u003c V4.5), SCALANCE XC216-4C (All versions \u003c V4.5), SCALANCE XC216-4C G (All versions \u003c V4.5), SCALANCE XC216-4C G (EIP Def.) (All versions \u003c V4.5), SCALANCE XC216-4C G EEC (All versions \u003c V4.5), SCALANCE XC216EEC (All versions \u003c V4.5), SCALANCE XC224 (All versions \u003c V4.5), SCALANCE XC224-4C G (All versions \u003c V4.5), SCALANCE XC224-4C G (EIP Def.) (All versions \u003c V4.5), SCALANCE XC224-4C G EEC (All versions \u003c V4.5), SCALANCE XF204 (All versions \u003c V4.5), SCALANCE XF204 DNA (All versions \u003c V4.5), SCALANCE XF204-2BA (All versions \u003c V4.5), SCALANCE XF204-2BA DNA (All versions \u003c V4.5), SCALANCE XP208 (All versions \u003c V4.5), SCALANCE XP208 (Ethernet/IP) (All versions \u003c V4.5), SCALANCE XP208EEC (All versions \u003c V4.5), SCALANCE XP208PoE EEC (All versions \u003c V4.5), SCALANCE XP216 (All versions \u003c V4.5), SCALANCE XP216 (Ethernet/IP) (All versions \u003c V4.5), SCALANCE XP216EEC (All versions \u003c V4.5), SCALANCE XP216POE EEC (All versions \u003c V4.5), SCALANCE XR324WG (24 x FE, AC 230V) (All versions \u003c V4.5), SCALANCE XR324WG (24 X FE, DC 24V) (All versions \u003c V4.5), SCALANCE XR326-2C PoE WG (All versions \u003c V4.5), SCALANCE XR326-2C PoE WG (without UL) (All versions \u003c V4.5), SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (All versions \u003c V4.5), SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (All versions \u003c V4.5), SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (All versions \u003c V4.5), SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (All versions \u003c V4.5), SCALANCE XR328-4C WG (28xGE, AC 230V) (All versions \u003c V4.5), SCALANCE XR328-4C WG (28xGE, DC 24V) (All versions \u003c V4.5), SIPLUS NET SCALANCE XC206-2 (All versions \u003c V4.5), SIPLUS NET SCALANCE XC206-2SFP (All versions \u003c V4.5), SIPLUS NET SCALANCE XC208 (All versions \u003c V4.5), SIPLUS NET SCALANCE XC216-4C (All versions \u003c V4.5)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-44318"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017962"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86596"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44318"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-44318",
        "trust": 3.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-699386",
        "trust": 2.5
      },
      {
        "db": "SIEMENS",
        "id": "SSA-180704",
        "trust": 1.8
      },
      {
        "db": "SIEMENS",
        "id": "SSA-690517",
        "trust": 1.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-353002",
        "trust": 1.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-320-08",
        "trust": 0.9
      },
      {
        "db": "JVN",
        "id": "JVNVU93250330",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU98271228",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU93656033",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU92598492",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-165-12",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-074-08",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-348-14",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017962",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86596",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44318",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86596"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44318"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017962"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44318"
      }
    ]
  },
  "id": "VAR-202311-0435",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86596"
      }
    ],
    "trust": 1.2076912
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86596"
      }
    ]
  },
  "last_update_date": "2024-08-14T13:07:52.663000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Multiple Siemens products use hard-coded encryption key vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/482171"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86596"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-321",
        "trust": 1.0
      },
      {
        "problemtype": "Using hardcoded encryption keys (CWE-321) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017962"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44318"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-699386.pdf"
      },
      {
        "trust": 1.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-353002.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html"
      },
      {
        "trust": 0.9,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-08"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu92598492/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu98271228/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu93656033/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu93250330/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-44318"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-14"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-08"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-12"
      },
      {
        "trust": 0.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-699386.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86596"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44318"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017962"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44318"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86596"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44318"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017962"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44318"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86596"
      },
      {
        "date": "2023-11-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44318"
      },
      {
        "date": "2024-01-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017962"
      },
      {
        "date": "2023-11-14T11:15:12.287000",
        "db": "NVD",
        "id": "CVE-2023-44318"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86596"
      },
      {
        "date": "2023-11-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44318"
      },
      {
        "date": "2024-06-17T05:32:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017962"
      },
      {
        "date": "2024-06-11T09:15:14.333000",
        "db": "NVD",
        "id": "CVE-2023-44318"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerabilities related to the use of hardcoded encryption keys in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017962"
      }
    ],
    "trust": 0.8
  }
}

var-202212-1136
Vulnerability from variot

Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain a vulnerability related to improper validation of quantities specified in input.Information may be obtained. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers.

The Siemens SCALANCE M-800/S615 series has an information disclosure vulnerability due to the affected device not properly checking the TFTP block size

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202212-1136",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance m876-4",
        "scope": "lt",
        "trust": 1.8,
        "vendor": "siemens",
        "version": "v8.0"
      },
      {
        "model": "scalance m812-1 adsl-router",
        "scope": "lt",
        "trust": 1.2,
        "vendor": "siemens",
        "version": "v8.0"
      },
      {
        "model": "scalance m816-1 adsl-router",
        "scope": "lt",
        "trust": 1.2,
        "vendor": "siemens",
        "version": "v8.0"
      },
      {
        "model": "scalance m876-3",
        "scope": "lt",
        "trust": 1.2,
        "vendor": "siemens",
        "version": "v8.0"
      },
      {
        "model": "scalance mum856-1",
        "scope": "lt",
        "trust": 1.2,
        "vendor": "siemens",
        "version": "v8.0"
      },
      {
        "model": "scalance w778-1 m12 eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w788-2 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m812-1 adsl-router",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc636-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance xp208eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w1788-2 eec m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w788-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w761-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w774-1 m12 eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w1788-2ia m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xf204-2ba",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208 eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc224",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance mum853-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w786-2 sfp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp216eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "siplus net scalance xc208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ruggedcom rm1224 lte\\ eu",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr326-2c poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb213-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w721-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "siplus net scalance xc216-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wam766-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w1788-2 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr328-4c wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb205-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w788-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m816-1 adsl-router",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance s615 eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance m804pb",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr524-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "siplus net scalance xc206-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc622-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "ruggedcom rm1224 lte\\ nam",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w786-2ia rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wum763-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wum766-1 6ghz",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m876-4",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wam766-1 6ghz",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m826-2 shdsl-router",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm416-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w738-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w1788-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208 poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr526-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wam766-1 ecc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w748-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w774-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr552-12m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance s615",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w722-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm408-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w774-1 m12 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc632-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance w734-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance sc646-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance m874-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance sc626-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance xc216-3g poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w786-2 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr528-6m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w1748-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w786-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xm408-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m874-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance wam763-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w778-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wum766-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc642-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance xb216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr324wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr326-2c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "siplus net scalance xc206-2sfp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w788-2 m12 eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance mum856-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance m876-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xf204",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xf204-2bca dna",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance s615 eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m812-1 adsl-router",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m876-4",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance s615",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "ruggedcom rm1224 lte eu",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-622-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-636-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "ruggedcom rm1224 lte nam",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m816-1 adsl-router",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance mum856-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m876-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc626-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m874-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-642-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance mum853-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m826-2 shdsl-router",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m804pb",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-646-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-632-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m874-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "ruggedcom rm1224 lte eu",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v8.0"
      },
      {
        "model": "ruggedcom rm1224 lte nam",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v8.0"
      },
      {
        "model": "scalance m804pb",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v8.0"
      },
      {
        "model": "scalance m826-2 shdsl-router",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v8.0"
      },
      {
        "model": "scalance m874-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v8.0"
      },
      {
        "model": "scalance m874-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v8.0"
      },
      {
        "model": "scalance mum853-1",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v8.0"
      },
      {
        "model": "scalance s615",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v8.0"
      },
      {
        "model": "scalance s615 eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v8.0"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-97251"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023553"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46143"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3089"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-46143",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.4,
            "id": "CNVD-2023-97251",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "productcert@siemens.com",
            "availabilityImpact": "NONE",
            "baseScore": 2.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.2,
            "id": "CVE-2022-46143",
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "None",
            "baseScore": 2.7,
            "baseSeverity": "Low",
            "confidentialityImpact": "Low",
            "exploitabilityScore": null,
            "id": "JVNDB-2022-023553",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "High",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2022-46143",
            "trust": 1.0,
            "value": "LOW"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-46143",
            "trust": 1.0,
            "value": "LOW"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2022-023553",
            "trust": 0.8,
            "value": "Low"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-97251",
            "trust": 0.6,
            "value": "LOW"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202212-3089",
            "trust": 0.6,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-97251"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023553"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3089"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46143"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46143"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain a vulnerability related to improper validation of quantities specified in input.Information may be obtained. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. \n\r\n\r\nThe Siemens SCALANCE M-800/S615 series has an information disclosure vulnerability due to the affected device not properly checking the TFTP block size",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-46143"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023553"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-97251"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-46143",
        "trust": 3.8
      },
      {
        "db": "SIEMENS",
        "id": "SSA-413565",
        "trust": 2.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-180704",
        "trust": 1.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-349-04",
        "trust": 1.4
      },
      {
        "db": "JVN",
        "id": "JVNVU91561630",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023553",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-97251",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3089",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-97251"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023553"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3089"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46143"
      }
    ]
  },
  "id": "VAR-202212-1136",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-97251"
      }
    ],
    "trust": 1.2398166874999998
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-97251"
      }
    ]
  },
  "last_update_date": "2024-08-14T12:11:36.523000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Siemens SCALANCE M-800/S615 series information leakage vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/500346"
      },
      {
        "title": "Siemens part of the product Security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=218338"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-97251"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3089"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-1284",
        "trust": 1.0
      },
      {
        "problemtype": "Improper validation of quantity specified in input (CWE-1284) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023553"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46143"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
      },
      {
        "trust": 1.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91561630/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-46143"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-04"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-349-04"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-46143/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-97251"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023553"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3089"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46143"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-97251"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023553"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3089"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46143"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-97251"
      },
      {
        "date": "2023-11-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-023553"
      },
      {
        "date": "2022-12-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202212-3089"
      },
      {
        "date": "2022-12-13T16:15:25.137000",
        "db": "NVD",
        "id": "CVE-2022-46143"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-97251"
      },
      {
        "date": "2023-11-29T03:03:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-023553"
      },
      {
        "date": "2022-12-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202212-3089"
      },
      {
        "date": "2024-08-13T08:15:05.483000",
        "db": "NVD",
        "id": "CVE-2022-46143"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3089"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerability in multiple Siemens products related to improper validation of quantities specified in inputs",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023553"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3089"
      }
    ],
    "trust": 0.6
  }
}

var-202101-0138
Vulnerability from variot

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products. SCALANCE X-200 and SCALANCE X-200IRT A vulnerability exists in the switch family regarding the lack of authentication for critical features.Denial of service (DoS) It may be put into a state. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0138",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt siplus net",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf201-3p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf202-2p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x308-2m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x201-3pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x202-2irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x320-3ldfe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf206-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2ba irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x201-3pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x200-4pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x204irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "siplus net scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x-200irt switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance switch family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x-200"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15799"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2020-15799",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2020-15799",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-02596",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2020-15799",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2020-15799",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-15799",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2020-15799",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-02596",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-856",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15799"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products. SCALANCE X-200 and SCALANCE X-200IRT A vulnerability exists in the switch family regarding the lack of authentication for critical features.Denial of service (DoS) It may be put into a state. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-15799"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-15799",
        "trust": 3.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-139628",
        "trust": 2.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-012-05",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0127",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15799"
      }
    ]
  },
  "id": "VAR-202101-0138",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      }
    ],
    "trust": 1.2641418511111109
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      }
    ]
  },
  "last_update_date": "2024-11-23T19:39:47.719000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-139628",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf"
      },
      {
        "title": "Patch for Scalance X Products key function certification missing vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/244024"
      },
      {
        "title": "Multiple  Siemens SCALANCE Fixes for access control error vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=139366"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-306",
        "trust": 1.0
      },
      {
        "problemtype": "Lack of authentication for important features (CWE-306) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15799"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-15799"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-05"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0127/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15799"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15799"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-01-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "date": "2021-10-04T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "date": "2021-01-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      },
      {
        "date": "2021-01-12T21:15:16.370000",
        "db": "NVD",
        "id": "CVE-2020-15799"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-02-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "date": "2021-10-04T05:21:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "date": "2021-09-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      },
      {
        "date": "2024-11-21T05:06:12.267000",
        "db": "NVD",
        "id": "CVE-2020-15799"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SCALANCE\u00a0X-200\u00a0 and \u00a0SCALANCE\u00a0X-200IRT\u00a0 Vulnerability in lack of authentication for critical features in the switch family",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "access control error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      }
    ],
    "trust": 0.6
  }
}

var-202208-0611
Vulnerability from variot

Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. SCALANCE M-800 firmware, SCALANCE S615 firmware, SCALANCE SC-600 Multiple Siemens products such as firmware have unspecified vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 industrial routers are used for secure remote access to plants via mobile networks (e.g. GPRS or UMTS) and have integrated security functions of firewalls to prevent unauthorized access, as well as VPNs to Secure data transmission. SCALANCE SC-600 devices (SC622-2C, SC632-2C, SC636-2C, SC642-2C, SC646-2C) are used to protect trusted industrial networks from untrusted network attacks. They allow filtering incoming and outgoing network connections in different ways. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. SCALANCE W-700 products are wireless communication devices based on the IEEE 802.11ax standard. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI).

A command injection vulnerability exists in Siemens SCALANCE products, which results from an affected device failing to properly filter input fields. A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE SC-600 family (All versions < V2.3.1), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202208-0611",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xr552-12m 2hr2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224-4c g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w700 ieee 802.11ac",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr524-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb205-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance sc-600",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.1"
      },
      {
        "model": "scalance xb208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324-4m poe ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr524-8c l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216-4c g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr528-6m l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance sc642-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.1"
      },
      {
        "model": "scalance sc632-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.1"
      },
      {
        "model": "scalance xr324-12m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc-200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr528-6m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2ba irt",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm400",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr-300eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr500",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208 \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w700 ieee 802.11n",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb213-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm408-8c l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr552-12m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm416-4c l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr552",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr-300",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr328-4c wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr526-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb-200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance sc636-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.1"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp216 \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf-200ba",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr528-6m 2hr2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm408-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr-300poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr552-12m 2hr2 l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w700 ieee 802.11ax",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm408-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm408-4c l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr326-2c poe wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr552-12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324-12m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr524",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp-200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance s615",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr528-6m 2hr2 l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp216eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324-4m eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr528",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance sc622-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.1"
      },
      {
        "model": "scalance xc208g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance sc646-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.1"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance m-800",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xm416-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr526-8c l3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr526",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr-300wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance sc-646-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb205-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-600",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc206-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb-200",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance w700 ieee 802.11ax",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb216",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-622-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc-200",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m-800",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb213-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-632-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb213-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-642-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance w700 ieee 802.11ac",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance w700 ieee 802.11n",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb205-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-636-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance s615",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb208",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m-800 s615",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "/"
      },
      {
        "model": "scalance sc-600 family",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v2.3.1"
      },
      {
        "model": "scalance w-700 ieee 802.11ax family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w-700 ieee 802.11n family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w-1700 ieee 802.11ac family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb-200 switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc-200 switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xf-200ba switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xm-400 family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp-200 switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr-300wg switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr-500 family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56476"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014933"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36323"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens has reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2715"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-36323",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-56476",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "productcert@siemens.com",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.3,
            "id": "CVE-2022-36323",
            "impactScore": 6.0,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.2,
            "id": "CVE-2022-36323",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 9.1,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2022-014933",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Changed",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2022-36323",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-36323",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2022-014933",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-56476",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202208-2715",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56476"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014933"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2715"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36323"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36323"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Affected devices do not properly sanitize an input field.  This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. SCALANCE M-800 firmware, SCALANCE S615 firmware, SCALANCE SC-600 Multiple Siemens products such as firmware have unspecified vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 industrial routers are used for secure remote access to plants via mobile networks (e.g. GPRS or UMTS) and have integrated security functions of firewalls to prevent unauthorized access, as well as VPNs to Secure data transmission. SCALANCE SC-600 devices (SC622-2C, SC632-2C, SC636-2C, SC642-2C, SC646-2C) are used to protect trusted industrial networks from untrusted network attacks. They allow filtering incoming and outgoing network connections in different ways. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. SCALANCE W-700 products are wireless communication devices based on the IEEE 802.11ax standard. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). \n\r\n\r\nA command injection vulnerability exists in Siemens SCALANCE products, which results from an affected device failing to properly filter input fields. A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE SC-600 family (All versions \u003c V2.3.1), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-36323"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014933"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-56476"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36323"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-36323",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-710008",
        "trust": 3.1
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-223-07",
        "trust": 1.5
      },
      {
        "db": "JVN",
        "id": "JVNVU90767165",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014933",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-56476",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2022.4032",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2715",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36323",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56476"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36323"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014933"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2715"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36323"
      }
    ]
  },
  "id": "VAR-202208-0611",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56476"
      }
    ],
    "trust": 1.2477712656666666
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56476"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:17:45.411000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Siemens SCALANCE product command injection vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/343616"
      },
      {
        "title": "Siemens SCALANCE Security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=243185"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56476"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2715"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-Other",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-74",
        "trust": 1.0
      },
      {
        "problemtype": "others (CWE-Other) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014933"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36323"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu90767165/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-36323"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-223-07"
      },
      {
        "trust": 0.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2022.4032"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-36323/"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-223-07"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/74.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-07"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56476"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36323"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014933"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2715"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36323"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-56476"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36323"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014933"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2715"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36323"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-08-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-56476"
      },
      {
        "date": "2022-08-10T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-36323"
      },
      {
        "date": "2023-09-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-014933"
      },
      {
        "date": "2022-08-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-2715"
      },
      {
        "date": "2022-08-10T12:15:12.863000",
        "db": "NVD",
        "id": "CVE-2022-36323"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-08-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-56476"
      },
      {
        "date": "2022-08-10T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-36323"
      },
      {
        "date": "2023-09-22T08:25:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-014933"
      },
      {
        "date": "2023-06-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-2715"
      },
      {
        "date": "2023-06-27T19:43:45.920000",
        "db": "NVD",
        "id": "CVE-2022-36323"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2715"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerabilities in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014933"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2715"
      }
    ],
    "trust": 0.6
  }
}

var-202212-1133
Vulnerability from variot

Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain vulnerabilities related to the use of cryptographic algorithms.Information may be obtained

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202212-1133",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xr552-12m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wam766-1 ecc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xm416-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr326-2c poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc642-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr328-4c wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w734-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "siplus net scalance xc206-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc632-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance w788-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "siplus net scalance xc208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w738-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr524-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance s615 eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance m874-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc646-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "ruggedcom rm1224 lte\\ eu",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2bca dna",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc224",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w786-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w748-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w786-2 sfp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "siplus net scalance xc206-2sfp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wum766-1 6ghz",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m826-2 shdsl-router",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w778-1 m12 eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr528-6m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m876-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr326-2c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w778-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w788-2 m12 eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb213-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wum766-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp216eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc636-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance w788-2 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance mum853-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "siplus net scalance xc216-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m804pb",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w774-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w1788-2ia m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr526-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w721-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance mum856-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ruggedcom rm1224 lte\\ nam",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m874-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2ba",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w1788-2 eec m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb205-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w786-2 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc622-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance w761-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-3g poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xf204 dna",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance s615",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance wum763-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr324wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wam763-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xm408-8c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w774-1 m12 eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance wam766-1 6ghz",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w786-2ia rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m812-1 adsl-router",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance wam766-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w774-1 m12 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xm408-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m816-1 adsl-router",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w788-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp208eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w1788-2 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w722-1 rj45",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance w1748-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208 poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m876-4",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w1788-1 m12",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance sc626-2c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance xc216eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208 eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xf204",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance s615 eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m812-1 adsl-router",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m876-4",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance s615",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "ruggedcom rm1224 lte eu",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-622-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-636-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "ruggedcom rm1224 lte nam",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m816-1 adsl-router",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance mum856-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m876-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc626-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m874-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-642-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance mum853-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m826-2 shdsl-router",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m804pb",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-646-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance sc-632-2c",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m874-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023551"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46140"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3091"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-46140",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "productcert@siemens.com",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2022-46140",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "None",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2022-023551",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2022-46140",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-46140",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2022-023551",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202212-3091",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023551"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3091"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46140"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46140"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain vulnerabilities related to the use of cryptographic algorithms.Information may be obtained",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-46140"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023551"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-46140",
        "trust": 3.2
      },
      {
        "db": "SIEMENS",
        "id": "SSA-413565",
        "trust": 2.4
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-349-04",
        "trust": 1.4
      },
      {
        "db": "JVN",
        "id": "JVNVU91561630",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023551",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3091",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023551"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3091"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46140"
      }
    ]
  },
  "id": "VAR-202212-1133",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.6398166875
  },
  "last_update_date": "2024-08-14T12:05:03.547000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Siemens part of the product Fixes for encryption problem vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=218340"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3091"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-327",
        "trust": 1.0
      },
      {
        "problemtype": "Use of incomplete or dangerous cryptographic algorithms (CWE-327) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023551"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46140"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91561630/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-46140"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-04"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-46140/"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-349-04"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023551"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3091"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46140"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023551"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3091"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-46140"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-023551"
      },
      {
        "date": "2022-12-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202212-3091"
      },
      {
        "date": "2022-12-13T16:15:25.007000",
        "db": "NVD",
        "id": "CVE-2022-46140"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-29T03:03:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-023551"
      },
      {
        "date": "2022-12-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202212-3091"
      },
      {
        "date": "2023-03-14T10:15:23.297000",
        "db": "NVD",
        "id": "CVE-2022-46140"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3091"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerabilities related to the use of cryptographic algorithms in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-023551"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "encryption problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3091"
      }
    ],
    "trust": 0.6
  }
}

var-202311-0440
Vulnerability from variot

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V7.2.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V7.2.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V7.2.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V7.2.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V7.2.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V7.2.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V7.2.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V7.2.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V7.2.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V7.2.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-2AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions). Affected products do not properly validate the content of uploaded X509 certificates which could allow an attacker with administrative privileges to execute arbitrary code on the device. scalance xb208 (e/ip) firmware, scalance xb208 (pn) firmware, scalance xb216 (e/ip) Multiple Siemens products, including firmware, contain vulnerabilities that allow untrusted, unrelated data to be accepted when trusted data is accepted.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202311-0440",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xr328-4c wg \\",
        "scope": "eq",
        "trust": 5.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb213-3 \\",
        "scope": "eq",
        "trust": 4.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb205-3 \\",
        "scope": "eq",
        "trust": 3.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb216 \\",
        "scope": "eq",
        "trust": 2.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb208 \\",
        "scope": "eq",
        "trust": 2.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb213-3ld \\",
        "scope": "eq",
        "trust": 2.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr324wg \\",
        "scope": "eq",
        "trust": 2.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xb205-3ld \\",
        "scope": "eq",
        "trust": 2.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2 \\",
        "scope": "eq",
        "trust": 2.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208g",
        "scope": null,
        "trust": 1.6,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": null,
        "trust": 1.6,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb208",
        "scope": null,
        "trust": 1.6,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xb216",
        "scope": null,
        "trust": 1.6,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": null,
        "trust": 1.6,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc206-2",
        "scope": null,
        "trust": 1.6,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc216-3g poe \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr326-2c poe wg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp216",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208g poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc224",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xf204-2ba",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "siplus net scalance xc206-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "siplus net scalance xc216-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2g poe \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xf204",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208g poe \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xf204 dna",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp216 \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp208 \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "siplus net scalance xc208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc224-4c g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp216eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr326-2c poe wg \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-4c g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-4c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208g \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "siplus net scalance xc206-2sfp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-3g poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp208eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xp208",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208g",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc206-2g poe eec \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xc208g poe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc208g eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc208eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc208",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr324wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr326-2c poe wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xr328-4c wg",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "siplus net scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-3g poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.5"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86597"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017563"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44317"
      }
    ]
  },
  "cve": "CVE-2023-44317",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2023-86597",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "productcert@siemens.com",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.2,
            "id": "CVE-2023-44317",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 7.2,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2023-017563",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2023-44317",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2023-017563",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-86597",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86597"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017563"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44317"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V7.2.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V7.2.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions \u003c V7.2.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V7.2.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V7.2.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V7.2.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V7.2.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V7.2.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V7.2.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V7.2.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions \u003c V7.2.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-2AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions). Affected products do not properly validate the content of uploaded X509 certificates which could allow an attacker with administrative privileges to execute arbitrary code on the device. scalance xb208 (e/ip) firmware, scalance xb208 (pn) firmware, scalance xb216 (e/ip) Multiple Siemens products, including firmware, contain vulnerabilities that allow untrusted, unrelated data to be accepted when trusted data is accepted.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-44317"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017563"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86597"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44317"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-44317",
        "trust": 3.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-699386",
        "trust": 2.5
      },
      {
        "db": "SIEMENS",
        "id": "SSA-068047",
        "trust": 1.8
      },
      {
        "db": "SIEMENS",
        "id": "SSA-602936",
        "trust": 1.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-690517",
        "trust": 1.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-320-08",
        "trust": 0.9
      },
      {
        "db": "JVN",
        "id": "JVNVU93250330",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU98271228",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU91198149",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU92598492",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-165-12",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-348-13",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-046-09",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017563",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-86597",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44317",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86597"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44317"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017563"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44317"
      }
    ]
  },
  "id": "VAR-202311-0440",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86597"
      }
    ],
    "trust": 1.2076912
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86597"
      }
    ]
  },
  "last_update_date": "2024-09-10T21:31:49.257000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Multiple Siemens products use trusted data to accept unrelated untrusted data vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/482166"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86597"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-349",
        "trust": 1.0
      },
      {
        "problemtype": "Accepting untrusted irrelevant data when accepting trusted data (CWE-349) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017563"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44317"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-699386.pdf"
      },
      {
        "trust": 1.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-068047.pdf"
      },
      {
        "trust": 1.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-699386.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-068047.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html"
      },
      {
        "trust": 0.9,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-08"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu92598492/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu98271228/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91198149/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu93250330/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-44317"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-13"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-09"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-12"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86597"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44317"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017563"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44317"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-86597"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-44317"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017563"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44317"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86597"
      },
      {
        "date": "2023-11-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44317"
      },
      {
        "date": "2024-01-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017563"
      },
      {
        "date": "2023-11-14T11:15:12.067000",
        "db": "NVD",
        "id": "CVE-2023-44317"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-86597"
      },
      {
        "date": "2023-11-21T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-44317"
      },
      {
        "date": "2024-06-17T05:31:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017563"
      },
      {
        "date": "2024-09-10T10:15:06.443000",
        "db": "NVD",
        "id": "CVE-2023-44317"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Untrusted irrelevant data acceptance vulnerability when accepting trusted data in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017563"
      }
    ],
    "trust": 0.8
  }
}