"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201906-0210",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "scalance x-200",
"scope": "lt",
"trust": 1.8,
"vendor": "siemens",
"version": "5.2.4"
},
{
"model": "scalance x-414-3e",
"scope": null,
"trust": 1.4,
"vendor": "siemens",
"version": null
},
{
"model": "scalance x-200irt",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance x-300",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance x-414-3e",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance x200 irt",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "scalance x300",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "scalance",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "x-300"
},
{
"model": "scalance",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "x-200\u003cv5.2.4"
},
{
"model": "scalance x-200irt",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "scalance x-414-3e",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "scalance",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "x-3000"
},
{
"model": "scalance x-200irt",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "scalance",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "x-2005.2.3"
},
{
"model": "scalance",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "x-2004.5"
},
{
"model": "scalance",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "x-2005.2.4"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "scalance x 200",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "scalance x 200irt",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "scalance x 300",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "scalance x 414 3e",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "837d970c-b3a2-4f6a-aa55-5bfc45dcb3b6"
},
{
"db": "CNVD",
"id": "CNVD-2019-17149"
},
{
"db": "BID",
"id": "108726"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005572"
},
{
"db": "NVD",
"id": "CVE-2019-6567"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:siemens:scalance_x-200_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:siemens:scalance_x-414-3e_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:siemens:scalance_x200irt_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:siemens:scalance_x300_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-005572"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Christopher Wade from Pen Test Partners,Siemens thanks Christopher Wade from Pen Test Partners for coordinated disclosure. Siemens reported this vulnerability to NCCIC.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201906-517"
}
],
"trust": 0.6
},
"cve": "CVE-2019-6567",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CVE-2019-6567",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 1.8,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2019-17149",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "837d970c-b3a2-4f6a-aa55-5bfc45dcb3b6",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:N/A:N",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "VHN-158002",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.1,
"vectorString": "AV:L/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2019-6567",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.5,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-6567",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2019-6567",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2019-6567",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2019-17149",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201906-517",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "837d970c-b3a2-4f6a-aa55-5bfc45dcb3b6",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-158002",
"trust": 0.1,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "837d970c-b3a2-4f6a-aa55-5bfc45dcb3b6"
},
{
"db": "CNVD",
"id": "CNVD-2019-17149"
},
{
"db": "VULHUB",
"id": "VHN-158002"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005572"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-517"
},
{
"db": "NVD",
"id": "CVE-2019-6567"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions \u003c V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords. plural SCALANCE The product contains vulnerabilities related to certificate and password management.Information may be obtained. SiemensSCALANCEXswitches are used to connect industrial components such as programmable logic controllers (PLCs) or human machine interfaces (HMIs). A local information disclosure vulnerability exists in SiemensSCALANCEXSwitches. Local attackers can exploit vulnerabilities to obtain sensitive information. Siemens SCALANCE X Switches are prone to an local information-disclosure vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. A trust management issue vulnerability exists in several Siemens products due to the program storing passwords in a recoverable format",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-6567"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005572"
},
{
"db": "CNVD",
"id": "CNVD-2019-17149"
},
{
"db": "BID",
"id": "108726"
},
{
"db": "IVD",
"id": "837d970c-b3a2-4f6a-aa55-5bfc45dcb3b6"
},
{
"db": "VULHUB",
"id": "VHN-158002"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-6567",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-646841",
"trust": 2.6
},
{
"db": "ICS CERT",
"id": "ICSA-19-162-04",
"trust": 1.7
},
{
"db": "BID",
"id": "108726",
"trust": 1.0
},
{
"db": "CNNVD",
"id": "CNNVD-201906-517",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2019-17149",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005572",
"trust": 0.8
},
{
"db": "IVD",
"id": "837D970C-B3A2-4F6A-AA55-5BFC45DCB3B6",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-158002",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "837d970c-b3a2-4f6a-aa55-5bfc45dcb3b6"
},
{
"db": "CNVD",
"id": "CNVD-2019-17149"
},
{
"db": "VULHUB",
"id": "VHN-158002"
},
{
"db": "BID",
"id": "108726"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005572"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-517"
},
{
"db": "NVD",
"id": "CVE-2019-6567"
}
]
},
"id": "VAR-201906-0210",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "837d970c-b3a2-4f6a-aa55-5bfc45dcb3b6"
},
{
"db": "CNVD",
"id": "CNVD-2019-17149"
},
{
"db": "VULHUB",
"id": "VHN-158002"
}
],
"trust": 1.4908257
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "837d970c-b3a2-4f6a-aa55-5bfc45dcb3b6"
},
{
"db": "CNVD",
"id": "CNVD-2019-17149"
}
]
},
"last_update_date": "2024-11-23T23:08:24.111000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-646841",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf"
},
{
"title": "Patch for SiemensSCALANCEXSwitches Local Information Disclosure Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/163431"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-17149"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005572"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-522",
"trust": 1.1
},
{
"problemtype": "CWE-257",
"trust": 1.0
},
{
"problemtype": "CWE-255",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-158002"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005572"
},
{
"db": "NVD",
"id": "CVE-2019-6567"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf"
},
{
"trust": 1.4,
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-162-04"
},
{
"trust": 0.9,
"url": "http://subscriber.communications.siemens.com/"
},
{
"trust": 0.9,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-19-162-04"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6567"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-6567"
},
{
"trust": 0.6,
"url": "https://www.securityfocus.com/bid/108726"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-19-162-04"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-17149"
},
{
"db": "VULHUB",
"id": "VHN-158002"
},
{
"db": "BID",
"id": "108726"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005572"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-517"
},
{
"db": "NVD",
"id": "CVE-2019-6567"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "837d970c-b3a2-4f6a-aa55-5bfc45dcb3b6"
},
{
"db": "CNVD",
"id": "CNVD-2019-17149"
},
{
"db": "VULHUB",
"id": "VHN-158002"
},
{
"db": "BID",
"id": "108726"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005572"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-517"
},
{
"db": "NVD",
"id": "CVE-2019-6567"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-06-13T00:00:00",
"db": "IVD",
"id": "837d970c-b3a2-4f6a-aa55-5bfc45dcb3b6"
},
{
"date": "2019-06-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-17149"
},
{
"date": "2019-06-12T00:00:00",
"db": "VULHUB",
"id": "VHN-158002"
},
{
"date": "2019-06-11T00:00:00",
"db": "BID",
"id": "108726"
},
{
"date": "2019-06-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-005572"
},
{
"date": "2019-06-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201906-517"
},
{
"date": "2019-06-12T14:29:04.820000",
"db": "NVD",
"id": "CVE-2019-6567"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-06-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-17149"
},
{
"date": "2020-10-06T00:00:00",
"db": "VULHUB",
"id": "VHN-158002"
},
{
"date": "2019-06-11T00:00:00",
"db": "BID",
"id": "108726"
},
{
"date": "2019-07-09T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-005572"
},
{
"date": "2021-02-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201906-517"
},
{
"date": "2024-11-21T04:46:42.633000",
"db": "NVD",
"id": "CVE-2019-6567"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "BID",
"id": "108726"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-517"
}
],
"trust": 0.9
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SCALANCE X Switches Local Information Disclosure Vulnerability",
"sources": [
{
"db": "IVD",
"id": "837d970c-b3a2-4f6a-aa55-5bfc45dcb3b6"
},
{
"db": "CNVD",
"id": "CNVD-2019-17149"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201906-517"
}
],
"trust": 0.6
}
}