All the vulnerabilites related to Siemens - Questa
cve-2024-47194
Vulnerability from cvelistv5
Published
2024-10-08 08:40
Modified
2024-10-08 17:12
Summary
A vulnerability has been identified in ModelSim (All versions < V2024.3), Questa (All versions < V2024.3). vish2.exe in affected applications allows a specific DLL file to be loaded from the current working directory. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges in installations where administrators or processes with elevated privileges launch vish2.exe from a user-writable directory.
Impacted products
Vendor Product Version
Siemens Questa Version: 0   < V2024.3
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:modelsim:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "modelsim",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2024.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:questa:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "questa",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2024.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-47194",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-08T17:11:44.350249Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-08T17:12:45.619Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "ModelSim",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2024.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Questa",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2024.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in ModelSim (All versions \u003c V2024.3), Questa (All versions \u003c V2024.3). vish2.exe in affected applications allows a specific DLL file to be loaded from the current working directory. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges in installations where administrators or processes with elevated privileges launch vish2.exe from a user-writable directory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-427",
              "description": "CWE-427: Uncontrolled Search Path Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:40:46.551Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-426509.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-47194",
    "datePublished": "2024-10-08T08:40:46.551Z",
    "dateReserved": "2024-09-20T15:14:29.689Z",
    "dateUpdated": "2024-10-08T17:12:45.619Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-42023
Vulnerability from cvelistv5
Published
2021-12-14 00:00
Modified
2024-08-04 03:22
Severity ?
Summary
A vulnerability has been identified in ModelSim Simulation (All versions), Questa Simulation (All versions). The RSA white-box implementation in affected applications insufficiently protects the built-in private keys that are required to decrypt electronic intellectual property (IP) data in accordance with the IEEE 1735 recommended practice. This could allow a sophisticated attacker to discover the keys, bypassing the protection intended by the IEEE 1735 recommended practice.
Impacted products
Vendor Product Version
Siemens Questa Simulation Version: All versions
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:22:25.772Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-400332.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ModelSim Simulation",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Questa Simulation",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in ModelSim Simulation (All versions), Questa Simulation (All versions). The RSA white-box implementation in affected applications insufficiently protects the built-in private keys that are required to decrypt electronic intellectual property (IP) data in accordance with the IEEE 1735 recommended practice. This could allow a sophisticated attacker to discover the keys, bypassing the protection intended by the IEEE 1735 recommended practice."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-522",
              "description": "CWE-522: Insufficiently Protected Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-08T00:00:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-400332.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-42023",
    "datePublished": "2021-12-14T00:00:00",
    "dateReserved": "2021-10-06T00:00:00",
    "dateUpdated": "2024-08-04T03:22:25.772Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-47196
Vulnerability from cvelistv5
Published
2024-10-08 08:40
Modified
2024-10-08 16:49
Summary
A vulnerability has been identified in ModelSim (All versions < V2024.3), Questa (All versions < V2024.3). vsimk.exe in affected applications allows a specific tcl file to be loaded from the current working directory. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges in installations where administrators or processes with elevated privileges launch vsimk.exe from a user-writable directory.
Impacted products
Vendor Product Version
Siemens Questa Version: 0   < V2024.3
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:questa:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "questa",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2024.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:modelsim:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "modelsim",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2024.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-47196",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-08T16:46:11.465483Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-08T16:49:55.857Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "ModelSim",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2024.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Questa",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2024.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in ModelSim (All versions \u003c V2024.3), Questa (All versions \u003c V2024.3). vsimk.exe in affected applications allows a specific tcl file to be loaded from the current working directory. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges in installations where administrators or processes with elevated privileges launch vsimk.exe from a user-writable directory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-427",
              "description": "CWE-427: Uncontrolled Search Path Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:40:49.065Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-426509.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-47196",
    "datePublished": "2024-10-08T08:40:49.065Z",
    "dateReserved": "2024-09-20T15:14:29.689Z",
    "dateUpdated": "2024-10-08T16:49:55.857Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-47195
Vulnerability from cvelistv5
Published
2024-10-08 08:40
Modified
2024-10-08 16:51
Summary
A vulnerability has been identified in ModelSim (All versions < V2024.3), Questa (All versions < V2024.3). gdb.exe in affected applications allows a specific executable file to be loaded from the current working directory. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges in installations where administrators or processes with elevated privileges launch gdb.exe from a user-writable directory.
Impacted products
Vendor Product Version
Siemens Questa Version: 0   < V2024.3
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:modelsim:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "modelsim",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2024.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:questa:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "questa",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2024.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-47195",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-08T16:50:30.816352Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-08T16:51:24.486Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "ModelSim",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2024.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Questa",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2024.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in ModelSim (All versions \u003c V2024.3), Questa (All versions \u003c V2024.3). gdb.exe in affected applications allows a specific executable file to be loaded from the current working directory. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges in installations where administrators or processes with elevated privileges launch gdb.exe from a user-writable directory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-427",
              "description": "CWE-427: Uncontrolled Search Path Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:40:47.801Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-426509.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-47195",
    "datePublished": "2024-10-08T08:40:47.801Z",
    "dateReserved": "2024-09-20T15:14:29.689Z",
    "dateUpdated": "2024-10-08T16:51:24.486Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}