All the vulnerabilites related to OMNTEC - Proteus Tank Monitoring
cve-2024-6981
Vulnerability from cvelistv5
Published
2024-09-27 16:11
Modified
2024-09-27 16:37
Summary
OMNTEC Proteus Tank Monitoring Missing Authentication for Critical Function
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:omntec:proteus_tank_monitoring:oel8000_iii_series:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "proteus_tank_monitoring",
            "vendor": "omntec",
            "versions": [
              {
                "status": "affected",
                "version": "oel8000_iii_series"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6981",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-27T16:33:38.207492Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-27T16:37:39.401Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Proteus Tank Monitoring",
          "vendor": "OMNTEC",
          "versions": [
            {
              "status": "affected",
              "version": "OEL8000III Series"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Pedro Umbelino of Bitsight reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OMNTEC Proteus Tank Monitoring OEL8000III Series\n\n\ncould allow an attacker to perform administrative actions without proper authentication."
            }
          ],
          "value": "OMNTEC Proteus Tank Monitoring OEL8000III Series\n\n\ncould allow an attacker to perform administrative actions without proper authentication."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-27T16:11:26.742Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-268-06"
        }
      ],
      "source": {
        "advisory": "ICSA-24-268-06",
        "discovery": "EXTERNAL"
      },
      "title": "OMNTEC Proteus Tank Monitoring Missing Authentication for Critical Function",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OMNTEC Mfg., Inc. has not responded to CISA\u0027s requests to coordinate at this time. Users can reach out to the vendor on their \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.omntec.com/contact\"\u003ewebsite\u003c/a\u003e.\n\n\u003cbr\u003e"
            }
          ],
          "value": "OMNTEC Mfg., Inc. has not responded to CISA\u0027s requests to coordinate at this time. Users can reach out to the vendor on their  website https://www.omntec.com/contact ."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2024-6981",
    "datePublished": "2024-09-27T16:11:26.742Z",
    "dateReserved": "2024-07-22T13:39:53.735Z",
    "dateUpdated": "2024-09-27T16:37:39.401Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}