CVE-2024-12399 (GCVE-0-2024-12399)
Vulnerability from cvelistv5
Published
2025-01-17 09:37
Modified
2025-09-09 20:41
Severity ?
6.1 (Medium) - CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N
7.1 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H
7.1 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
Summary
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability
exists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs
man in the middle attack by intercepting the communication.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | Pro-face GP-Pro EX |
Version: all version |
||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-12399", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-17T13:19:08.787250Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-12T16:55:25.689Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Pro-face GP-Pro EX", "vendor": "Schneider Electric", "versions": [ { "lessThan": "v5.00.100", "status": "affected", "version": "all version", "versionType": "version" } ] }, { "defaultStatus": "unaffected", "product": "Pro-face Remote HMI", "vendor": "Schneider Electric", "versions": [ { "lessThan": "v1.70.000", "status": "affected", "version": "all versions", "versionType": "version" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\nman in the middle attack by intercepting the communication.\n\n\u003cbr\u003e" } ], "value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\nman in the middle attack by intercepting the communication." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "HIGH", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 6.1, "baseSeverity": "MEDIUM", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "PASSIVE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "LOW", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-924", "description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-09-09T20:41:23.793Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2024-12399", "datePublished": "2025-01-17T09:37:35.734Z", "dateReserved": "2024-12-10T09:21:04.278Z", "dateUpdated": "2025-09-09T20:41:23.793Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }