All the vulnerabilites related to Siemens - Parasolid V37.1
cve-2024-54091
Vulnerability from cvelistv5
Published
2024-12-10 13:54
Modified
2024-12-10 17:17
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in Parasolid V36.1 (All versions < V36.1.225), Parasolid V37.0 (All versions < V37.0.173), Parasolid V37.1 (All versions < V37.1.109). The affected applications contain an out of bounds write vulnerability when parsing specially crafted PAR files.
This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Parasolid V36.1 |
Version: 0 < V36.1.225 |
||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-54091", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-12-10T15:15:24.096235Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-12-10T17:17:59.464Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Parasolid V36.1", "vendor": "Siemens", "versions": [ { "lessThan": "V36.1.225", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V37.0", "vendor": "Siemens", "versions": [ { "lessThan": "V37.0.173", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V37.1", "vendor": "Siemens", "versions": [ { "lessThan": "V37.1.109", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V36.1 (All versions \u003c V36.1.225), Parasolid V37.0 (All versions \u003c V37.0.173), Parasolid V37.1 (All versions \u003c V37.1.109). The affected applications contain an out of bounds write vulnerability when parsing specially crafted PAR files.\r\nThis could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:54:17.315Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-979056.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-54091", "datePublished": "2024-12-10T13:54:17.315Z", "dateReserved": "2024-11-28T12:05:26.694Z", "dateUpdated": "2024-12-10T17:17:59.464Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }