All the vulnerabilites related to PTZOptics - PT30X-SDI
cve-2024-8957
Vulnerability from cvelistv5
Published
2024-09-17 20:08
Modified
2024-11-04 17:20
Severity ?
EPSS score ?
Summary
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.
References
▼ | URL | Tags |
---|---|---|
https://ptzoptics.com/firmware-changelog/ | vendor-advisory | |
https://vulncheck.com/advisories/ptzoptics-command-injection | third-party-advisory |
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "pt30x-sdi_firmware", "vendor": "ptzoptics", "versions": [ { "lessThan": "6.3.40", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "cpes": [ "cpe:2.3:o:ptzoptics:pt30x-ndi_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "pt30x-ndi_firmware", "vendor": "ptzoptics", "versions": [ { "lessThan": "6.3.40", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-8957", "options": [ { "Exploitation": "active" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-04T16:04:10.696120Z", "version": "2.0.3" }, "type": "ssvc" } }, { "other": { "content": { "dateAdded": "2024-11-04", "reference": "https://www.cisa.gov/sites/default/files/feeds/known_exploited_vulnerabilities.json" }, "type": "kev" } } ], "providerMetadata": { "dateUpdated": "2024-11-04T17:20:22.792Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "timeline": [ { "lang": "en", "time": "2024-11-04T00:00:00+00:00", "value": "CVE-2024-8957 added to CISA KEV" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "PT30X-SDI", "vendor": "PTZOptics", "versions": [ { "lessThan": "6.3.40", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PT30X-NDI", "vendor": "PTZOptics", "versions": [ { "lessThan": "6.3.40", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Konstantin Lazarev of GreyNoise" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.\u003cbr\u003e" } ], "value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices." } ], "impacts": [ { "capecId": "CAPEC-88", "descriptions": [ { "lang": "en", "value": "CAPEC-88 OS Command Injection" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-17T20:08:25.588Z", "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10", "shortName": "VulnCheck" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://ptzoptics.com/firmware-changelog/" }, { "tags": [ "third-party-advisory" ], "url": "https://vulncheck.com/advisories/ptzoptics-command-injection" } ], "source": { "discovery": "UNKNOWN" }, "tags": [ "x_known-exploited-vulnerability" ], "title": "PTZOptics NDI and SDI Cameras Command Injection via NTP Address Configuration", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10", "assignerShortName": "VulnCheck", "cveId": "CVE-2024-8957", "datePublished": "2024-09-17T20:08:25.588Z", "dateReserved": "2024-09-17T19:08:48.129Z", "dateUpdated": "2024-11-04T17:20:22.792Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-8956
Vulnerability from cvelistv5
Published
2024-09-17 19:59
Modified
2024-11-04 17:20
Severity ?
EPSS score ?
Summary
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.
References
▼ | URL | Tags |
---|---|---|
https://ptzoptics.com/firmware-changelog/ | vendor-advisory | |
https://vulncheck.com/advisories/ptzoptics-insufficient-auth | third-party-advisory |
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "pt30x-sdi_firmware", "vendor": "ptzoptics", "versions": [ { "lessThan": "6.3.40", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "pt30x-ndi-xx-g2_firmware", "vendor": "ptzoptics", "versions": [ { "lessThan": "6.3.40", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-8956", "options": [ { "Exploitation": "active" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-04T16:05:10.557594Z", "version": "2.0.3" }, "type": "ssvc" } }, { "other": { "content": { "dateAdded": "2024-11-04", "reference": "https://www.cisa.gov/sites/default/files/feeds/known_exploited_vulnerabilities.json" }, "type": "kev" } } ], "providerMetadata": { "dateUpdated": "2024-11-04T17:20:22.472Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "timeline": [ { "lang": "en", "time": "2024-11-04T00:00:00+00:00", "value": "CVE-2024-8956 added to CISA KEV" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "PT30X-SDI", "vendor": "PTZOptics", "versions": [ { "lessThan": "6.3.40", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PT30X-NDI", "vendor": "PTZOptics", "versions": [ { "lessThan": "6.3.40", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Konstantin Lazarev of GreyNoise" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.\u003cbr\u003e" } ], "value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file." } ], "impacts": [ { "capecId": "CAPEC-114", "descriptions": [ { "lang": "en", "value": "CAPEC-114 Authentication Abuse" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "CWE-287 Improper Authentication", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-17T20:02:11.772Z", "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10", "shortName": "VulnCheck" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://ptzoptics.com/firmware-changelog/" }, { "tags": [ "third-party-advisory" ], "url": "https://vulncheck.com/advisories/ptzoptics-insufficient-auth" } ], "source": { "discovery": "UNKNOWN" }, "tags": [ "x_known-exploited-vulnerability" ], "title": "PTZOptics NDI and SDI Cameras /cgi-bin/param.cgi Insufficient Authentication", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10", "assignerShortName": "VulnCheck", "cveId": "CVE-2024-8956", "datePublished": "2024-09-17T19:59:27.205Z", "dateReserved": "2024-09-17T19:08:47.005Z", "dateUpdated": "2024-11-04T17:20:22.472Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }