All the vulnerabilites related to Siemens - Mendix Runtime V7
cve-2022-24309
Vulnerability from cvelistv5
Published
2022-03-08 11:31
Modified
2024-10-08 08:39
Summary
A vulnerability has been identified in Mendix Runtime V7 (All versions < V7.23.29), Mendix Runtime V8 (All versions < V8.18.16), Mendix Runtime V9 (All versions < V9.13 only with Runtime Custom Setting *DataStorage.UseNewQueryHandler* set to False). If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data.
Impacted products
Vendor Product Version
Siemens Mendix Runtime V8 Version: 0   < V8.18.16
Siemens Mendix Runtime V9 Version: 0   < V9.13
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:07:02.516Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148641.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.23.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.18.16",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V7 (All versions \u003c V7.23.29), Mendix Runtime V8 (All versions \u003c V8.18.16), Mendix Runtime V9 (All versions \u003c V9.13 only with Runtime Custom Setting *DataStorage.UseNewQueryHandler* set to False). If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:39:51.939Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148641.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-24309",
    "datePublished": "2022-03-08T11:31:29",
    "dateReserved": "2022-02-02T00:00:00",
    "dateUpdated": "2024-10-08T08:39:51.939Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}