Search criteria
2 vulnerabilities found for MaxAI Workbench by HCL Software
CVE-2025-31995 (GCVE-0-2025-31995)
Vulnerability from cvelistv5 – Published: 2025-10-13 04:58 – Updated: 2025-10-14 19:36
VLAI
Title
HCL Unica MaxAI Workbench is vulnerable to improper input validation
Summary
HCL Unica MaxAI Workbench is vulnerable to improper input validation. This allows attackers to exploit vulnerabilities such as SQL Injection, XSS, or command injection, leading to unauthorized access or data breaches, etc.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HCL Software | MaxAI Workbench |
Affected:
v12.1.10 - v25.1
|
Date Public
2025-10-13 04:55
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-31995",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T19:35:20.568571Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T19:36:39.714Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MaxAI Workbench",
"vendor": "HCL Software",
"versions": [
{
"status": "affected",
"version": "v12.1.10 - v25.1"
}
]
}
],
"datePublic": "2025-10-13T04:55:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "HCL Unica MaxAI Workbench is vulnerable to improper input validation. This allows attackers to exploit vulnerabilities such as SQL Injection, XSS, or command injection, leading to unauthorized access or data breaches, etc.\u003cbr\u003e"
}
],
"value": "HCL Unica MaxAI Workbench is vulnerable to improper input validation. This allows attackers to exploit vulnerabilities such as SQL Injection, XSS, or command injection, leading to unauthorized access or data breaches, etc."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-13T04:58:20.465Z",
"orgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
"shortName": "HCL"
},
"references": [
{
"url": "https://support.hcl-software.com/csm?id=kb_article\u0026sysparm_article=KB0124425"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "HCL Unica MaxAI Workbench is vulnerable to improper input validation",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
"assignerShortName": "HCL",
"cveId": "CVE-2025-31995",
"datePublished": "2025-10-13T04:58:20.465Z",
"dateReserved": "2025-04-01T18:46:35.961Z",
"dateUpdated": "2025-10-14T19:36:39.714Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-31995 (GCVE-0-2025-31995)
Vulnerability from nvd – Published: 2025-10-13 04:58 – Updated: 2025-10-14 19:36
VLAI
Title
HCL Unica MaxAI Workbench is vulnerable to improper input validation
Summary
HCL Unica MaxAI Workbench is vulnerable to improper input validation. This allows attackers to exploit vulnerabilities such as SQL Injection, XSS, or command injection, leading to unauthorized access or data breaches, etc.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HCL Software | MaxAI Workbench |
Affected:
v12.1.10 - v25.1
|
Date Public
2025-10-13 04:55
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-31995",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T19:35:20.568571Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T19:36:39.714Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MaxAI Workbench",
"vendor": "HCL Software",
"versions": [
{
"status": "affected",
"version": "v12.1.10 - v25.1"
}
]
}
],
"datePublic": "2025-10-13T04:55:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "HCL Unica MaxAI Workbench is vulnerable to improper input validation. This allows attackers to exploit vulnerabilities such as SQL Injection, XSS, or command injection, leading to unauthorized access or data breaches, etc.\u003cbr\u003e"
}
],
"value": "HCL Unica MaxAI Workbench is vulnerable to improper input validation. This allows attackers to exploit vulnerabilities such as SQL Injection, XSS, or command injection, leading to unauthorized access or data breaches, etc."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-13T04:58:20.465Z",
"orgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
"shortName": "HCL"
},
"references": [
{
"url": "https://support.hcl-software.com/csm?id=kb_article\u0026sysparm_article=KB0124425"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "HCL Unica MaxAI Workbench is vulnerable to improper input validation",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
"assignerShortName": "HCL",
"cveId": "CVE-2025-31995",
"datePublished": "2025-10-13T04:58:20.465Z",
"dateReserved": "2025-04-01T18:46:35.961Z",
"dateUpdated": "2025-10-14T19:36:39.714Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}