All the vulnerabilites related to Iocharger - Iocharger firmware for AC chargers
cve-2024-43652
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-01-09 14:43
Summary
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-43652",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-09T14:42:07.955181Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-09T14:43:04.986Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Iocharger firmware for AC chargers",
          "vendor": "Iocharger",
          "versions": [
            {
              "lessThan": "24120701",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Wilco van Beijnum"
        },
        {
          "lang": "en",
          "type": "analyst",
          "value": "Harm van den Brink (DIVD)"
        },
        {
          "lang": "en",
          "type": "analyst",
          "value": "Frank Breedijk (DIVD)"
        }
      ],
      "datePublic": "2025-01-09T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\u003cbr\u003eThis issue affects Iocharger firmware for AC model chargers before version 24120701\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The \u0026lt;redacted\u0026gt; binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a crafted HTTP request.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\u003cbr\u003efiles and services.\u003cbr\u003e"
            }
          ],
          "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\nThis issue affects Iocharger firmware for AC model chargers before version 24120701\n\nLikelihood: Moderate \u2013 The \u003credacted\u003e binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\nfiles and services."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88 OS Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "USER",
            "Safety": "PRESENT",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "NONE",
            "valueDensity": "DIFFUSE",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y/R:U/V:D/RE:M",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "MODERATE"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-250",
              "description": "CWE-250: Execution with Unnecessary Privileges",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "description": "OWASP-A03: Injection",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-09T07:56:46.379Z",
        "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "shortName": "DIVD"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://csirt.divd.nl/DIVD-2024-00035/"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://csirt.divd.nl/CVE-2024-43652/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://iocharger.com"
        }
      ],
      "source": {
        "advisory": "DIVD-2024-00035",
        "discovery": "EXTERNAL"
      },
      "title": "Authenticated command injection in the \u003credacted\u003e action leads to full remote code execution as root on the charging station",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
    "assignerShortName": "DIVD",
    "cveId": "CVE-2024-43652",
    "datePublished": "2025-01-09T07:56:46.379Z",
    "dateReserved": "2024-08-14T09:27:41.767Z",
    "dateUpdated": "2025-01-09T14:43:04.986Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",