Search criteria

2 vulnerabilities found for High Sec End of Line Module by Gallagher

CVE-2025-52578 (GCVE-0-2025-52578)

Vulnerability from cvelistv5 – Published: 2025-11-18 03:26 – Updated: 2025-11-19 16:49
VLAI
Summary
Incorrect Usage of Seeds in Pseudo-Random Number Generator (CWE- 335) vulnerability in the High Sec ELM may allow a sophisticated attacker with physical access, to compromise internal device communications. This issue affects Command Centre Server: 9.30 prior to vCR9.30.251028a (distributed in 9.30.2881 (MR3)), 9.20 prior to vCR9.20.251028a (distributed in 9.20.3265 (MR5)), 9.10 prior to vCR9.10.251028a (distributed in 9.10.4135 (MR8)), all versions of 9.00 and prior.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-335 - Incorrect Usage of Seeds in Pseudo-Random Number Generator (PRNG)
Assigner
Impacted products
Vendor Product Version
Gallagher High Sec End of Line Module Affected: 0 , ≤ 9.00 (custom)
Affected: 9.30 , < vCR9.30.251028a (custom)
Affected: 9.20 , < vCR9.20.251028a (custom)
Affected: 9.10 , < vCR9.10.251028a (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-52578",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-18T15:04:03.417918Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-19T16:49:32.455Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "High Sec End of Line Module",
          "vendor": "Gallagher",
          "versions": [
            {
              "lessThanOrEqual": "9.00",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            },
            {
              "lessThan": "vCR9.30.251028a",
              "status": "affected",
              "version": "9.30",
              "versionType": "custom"
            },
            {
              "lessThan": "vCR9.20.251028a",
              "status": "affected",
              "version": "9.20",
              "versionType": "custom"
            },
            {
              "lessThan": "vCR9.10.251028a",
              "status": "affected",
              "version": "9.10",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIncorrect Usage of Seeds in Pseudo-Random Number Generator (CWE- 335) vulnerability in the High Sec ELM\u003c/span\u003e\u003cstrong\u003e\u0026nbsp;\u003c/strong\u003emay\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eallow a sophisticated attacker with physical access, to compromise internal device communications.\u003c/span\u003e\n\n\u003cp\u003eThis issue affects Command Centre Server: \n\n9.30 prior to vCR9.30.251028a (distributed in 9.30.2881 (MR3)), 9.20 prior to vCR9.20.251028a (distributed in 9.20.3265 (MR5)), 9.10 prior to vCR9.10.251028a (distributed in 9.10.4135 (MR8)),\u0026nbsp;all versions of 9.00 and prior.\n\n\u003c/p\u003e"
            }
          ],
          "value": "Incorrect Usage of Seeds in Pseudo-Random Number Generator (CWE- 335) vulnerability in the High Sec ELM\u00a0may\u00a0allow a sophisticated attacker with physical access, to compromise internal device communications.\n\nThis issue affects Command Centre Server: \n\n9.30 prior to vCR9.30.251028a (distributed in 9.30.2881 (MR3)), 9.20 prior to vCR9.20.251028a (distributed in 9.20.3265 (MR5)), 9.10 prior to vCR9.10.251028a (distributed in 9.10.4135 (MR8)),\u00a0all versions of 9.00 and prior."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-335",
              "description": "CWE-335 Incorrect Usage of Seeds in Pseudo-Random Number Generator (PRNG)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-18T03:26:20.887Z",
        "orgId": "0c426f27-3ee1-4eff-be88-288d5a1822bc",
        "shortName": "Gallagher"
      },
      "references": [
        {
          "url": "https://security.gallagher.com/en-NZ/Security-Advisories/CVE-2025-52578"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0c426f27-3ee1-4eff-be88-288d5a1822bc",
    "assignerShortName": "Gallagher",
    "cveId": "CVE-2025-52578",
    "datePublished": "2025-11-18T03:26:20.887Z",
    "dateReserved": "2025-11-11T04:00:46.463Z",
    "dateUpdated": "2025-11-19T16:49:32.455Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-52578 (GCVE-0-2025-52578)

Vulnerability from nvd – Published: 2025-11-18 03:26 – Updated: 2025-11-19 16:49
VLAI
Summary
Incorrect Usage of Seeds in Pseudo-Random Number Generator (CWE- 335) vulnerability in the High Sec ELM may allow a sophisticated attacker with physical access, to compromise internal device communications. This issue affects Command Centre Server: 9.30 prior to vCR9.30.251028a (distributed in 9.30.2881 (MR3)), 9.20 prior to vCR9.20.251028a (distributed in 9.20.3265 (MR5)), 9.10 prior to vCR9.10.251028a (distributed in 9.10.4135 (MR8)), all versions of 9.00 and prior.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-335 - Incorrect Usage of Seeds in Pseudo-Random Number Generator (PRNG)
Assigner
Impacted products
Vendor Product Version
Gallagher High Sec End of Line Module Affected: 0 , ≤ 9.00 (custom)
Affected: 9.30 , < vCR9.30.251028a (custom)
Affected: 9.20 , < vCR9.20.251028a (custom)
Affected: 9.10 , < vCR9.10.251028a (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-52578",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-18T15:04:03.417918Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-19T16:49:32.455Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "High Sec End of Line Module",
          "vendor": "Gallagher",
          "versions": [
            {
              "lessThanOrEqual": "9.00",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            },
            {
              "lessThan": "vCR9.30.251028a",
              "status": "affected",
              "version": "9.30",
              "versionType": "custom"
            },
            {
              "lessThan": "vCR9.20.251028a",
              "status": "affected",
              "version": "9.20",
              "versionType": "custom"
            },
            {
              "lessThan": "vCR9.10.251028a",
              "status": "affected",
              "version": "9.10",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIncorrect Usage of Seeds in Pseudo-Random Number Generator (CWE- 335) vulnerability in the High Sec ELM\u003c/span\u003e\u003cstrong\u003e\u0026nbsp;\u003c/strong\u003emay\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eallow a sophisticated attacker with physical access, to compromise internal device communications.\u003c/span\u003e\n\n\u003cp\u003eThis issue affects Command Centre Server: \n\n9.30 prior to vCR9.30.251028a (distributed in 9.30.2881 (MR3)), 9.20 prior to vCR9.20.251028a (distributed in 9.20.3265 (MR5)), 9.10 prior to vCR9.10.251028a (distributed in 9.10.4135 (MR8)),\u0026nbsp;all versions of 9.00 and prior.\n\n\u003c/p\u003e"
            }
          ],
          "value": "Incorrect Usage of Seeds in Pseudo-Random Number Generator (CWE- 335) vulnerability in the High Sec ELM\u00a0may\u00a0allow a sophisticated attacker with physical access, to compromise internal device communications.\n\nThis issue affects Command Centre Server: \n\n9.30 prior to vCR9.30.251028a (distributed in 9.30.2881 (MR3)), 9.20 prior to vCR9.20.251028a (distributed in 9.20.3265 (MR5)), 9.10 prior to vCR9.10.251028a (distributed in 9.10.4135 (MR8)),\u00a0all versions of 9.00 and prior."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-335",
              "description": "CWE-335 Incorrect Usage of Seeds in Pseudo-Random Number Generator (PRNG)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-18T03:26:20.887Z",
        "orgId": "0c426f27-3ee1-4eff-be88-288d5a1822bc",
        "shortName": "Gallagher"
      },
      "references": [
        {
          "url": "https://security.gallagher.com/en-NZ/Security-Advisories/CVE-2025-52578"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0c426f27-3ee1-4eff-be88-288d5a1822bc",
    "assignerShortName": "Gallagher",
    "cveId": "CVE-2025-52578",
    "datePublished": "2025-11-18T03:26:20.887Z",
    "dateReserved": "2025-11-11T04:00:46.463Z",
    "dateUpdated": "2025-11-19T16:49:32.455Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}