Vulnerabilites related to Hewlett Packard Enterprise (HPE) - HPE Athonet Core
CVE-2024-24452 (GCVE-0-2024-24452)
Vulnerability from cvelistv5
Published
2024-11-15 00:00
Modified
2025-03-31 20:27
Severity ?
VLAI Severity ?
EPSS score ?
Summary
An invalid memory access when handling the ProtocolIE_ID field of E-RAB Release Indication messages in Athonet vEPC MME v11.4.0 allows attackers to cause a Denial of Service (DoS) to the cellular network by repeatedly initiating connections and sending a crafted payload.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Hewlett Packard Enterprise (HPE) | HPE Athonet Core |
Version: HPE Athonet Core 11.0 ≤ 11.6 |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:athonet:vepc_mmc:11.4.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "vepc_mmc", "vendor": "athonet", "versions": [ { "status": "affected", "version": "11.4.0" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-24452", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-15T20:57:11.716650Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125 Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-15T20:58:54.431Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "HPE Athonet Core", "vendor": "Hewlett Packard Enterprise (HPE)", "versions": [ { "lessThanOrEqual": "11.6", "status": "affected", "version": "HPE Athonet Core 11.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "This vulnerability was discovered by Bennett, N., Zhu, W., Simon, B., Kennedy, R., Enck, W., Traynor, P., Butler, K. (2024). RANsacked: A Domain-Informed Approach for Fuzzing LTE and 5G RAN-Core Interfaces. https://nathanielbennett.com/publications/ransacked.pdf" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn invalid memory access when handling the ProtocolIE_ID field of\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eE-RAB Release Indication messages in Athonet vEPC MME v11.4.0\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eallows attackers to cause a Denial of Service (DoS) to the cellular\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003enetwork by repeatedly initiating connections and sending a crafted\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003epayload.\u003c/span\u003e\u003c/p\u003e" } ], "value": "An invalid memory access when handling the ProtocolIE_ID field of\u00a0E-RAB Release Indication messages in Athonet vEPC MME v11.4.0\u00a0allows attackers to cause a Denial of Service (DoS) to the cellular\u00a0network by repeatedly initiating connections and sending a crafted\u00a0payload." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-31T20:27:14.430Z", "orgId": "eb103674-0d28-4225-80f8-39fb86215de0", "shortName": "hpe" }, "references": [ { "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04780en_us\u0026docLocale=en_US" } ], "source": { "advisory": "HPESBGN04780", "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-24452", "datePublished": "2024-11-15T00:00:00.000Z", "dateReserved": "2024-01-25T00:00:00.000Z", "dateUpdated": "2025-03-31T20:27:14.430Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-24459 (GCVE-0-2024-24459)
Vulnerability from cvelistv5
Published
2024-11-15 00:00
Modified
2025-08-26 21:11
Severity ?
VLAI Severity ?
EPSS score ?
Summary
An invalid memory access when handling the ProtocolIE_ID field of S1Setup Request messages in Athonet vEPC MME v11.4.0 allows attackers to cause a Denial of Service (DoS) to the cellular network by repeatedly initiating connections and sending a crafted payload.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Hewlett Packard Enterprise (HPE) | HPE Athonet Core |
Version: HPE Athonet Core 11.0 ≤ 11.6 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-24459", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-15T20:57:15.378695Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125 Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-26T21:11:48.846Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "HPE Athonet Core", "vendor": "Hewlett Packard Enterprise (HPE)", "versions": [ { "lessThanOrEqual": "11.6", "status": "affected", "version": "HPE Athonet Core 11.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "This vulnerability was discovered by Bennett, N., Zhu, W., Simon, B., Kennedy, R., Enck, W., Traynor, P., Butler, K. (2024). RANsacked: A Domain-Informed Approach for Fuzzing LTE and 5G RAN-Core Interfaces. https://nathanielbennett.com/publications/ransacked.pdf" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn invalid memory access when handling the ProtocolIE_ID field of\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eS1Setup Request messages in Athonet vEPC MME v11.4.0 allows\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eattackers to cause a Denial of Service (DoS) to the cellular network by\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003erepeatedly initiating connections and sending a crafted payload.\u003c/span\u003e\u003c/p\u003e" } ], "value": "An invalid memory access when handling the ProtocolIE_ID field of\u00a0S1Setup Request messages in Athonet vEPC MME v11.4.0 allows\u00a0attackers to cause a Denial of Service (DoS) to the cellular network by\u00a0repeatedly initiating connections and sending a crafted payload." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-31T20:37:22.472Z", "orgId": "eb103674-0d28-4225-80f8-39fb86215de0", "shortName": "hpe" }, "references": [ { "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04780en_us\u0026docLocale=en_US" } ], "source": { "advisory": "HPESBGN04780", "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-24459", "datePublished": "2024-11-15T00:00:00.000Z", "dateReserved": "2024-01-25T00:00:00.000Z", "dateUpdated": "2025-08-26T21:11:48.846Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-24453 (GCVE-0-2024-24453)
Vulnerability from cvelistv5
Published
2024-11-15 00:00
Modified
2025-08-26 21:07
Severity ?
VLAI Severity ?
EPSS score ?
Summary
An invalid memory access when handling the ProtocolIE_ID field of E-RAB NotToBeModifiedBearerModInd information element in Athonet vEPC MME v11.4.0 allows attackers to cause a Denial of Service (DoS) to the cellular network by repeatedly initiating connections and sending a crafted payload.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Hewlett Packard Enterprise (HPE) | HPE Athonet Core |
Version: HPE Athonet Core 11.0 ≤ 11.6 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-24453", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-08-26T21:06:03.233205Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125 Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-26T21:07:00.137Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "HPE Athonet Core", "vendor": "Hewlett Packard Enterprise (HPE)", "versions": [ { "lessThanOrEqual": "11.6", "status": "affected", "version": "HPE Athonet Core 11.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "This vulnerability was discovered by Bennett, N., Zhu, W., Simon, B., Kennedy, R., Enck, W., Traynor, P., Butler, K. (2024). RANsacked: A Domain-Informed Approach for Fuzzing LTE and 5G RAN-Core Interfaces. https://nathanielbennett.com/publications/ransacked.pdf" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn invalid memory access when handling the ProtocolIE_ID field of\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eE-RAB NotToBeModifiedBearerModInd information element in\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAthonet vEPC MME v11.4.0 allows attackers to cause a Denial of\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eService (DoS) to the cellular network by repeatedly initiating\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003econnections and sending a crafted payload.\u003c/span\u003e\u003c/p\u003e" } ], "value": "An invalid memory access when handling the ProtocolIE_ID field of\u00a0E-RAB NotToBeModifiedBearerModInd information element in\u00a0Athonet vEPC MME v11.4.0 allows attackers to cause a Denial of\u00a0Service (DoS) to the cellular network by repeatedly initiating\u00a0connections and sending a crafted payload." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-31T20:27:21.698Z", "orgId": "eb103674-0d28-4225-80f8-39fb86215de0", "shortName": "hpe" }, "references": [ { "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04780en_us\u0026docLocale=en_US" } ], "source": { "advisory": "HPESBGN04780", "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-24453", "datePublished": "2024-11-15T00:00:00.000Z", "dateReserved": "2024-01-25T00:00:00.000Z", "dateUpdated": "2025-08-26T21:07:00.137Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-24456 (GCVE-0-2024-24456)
Vulnerability from cvelistv5
Published
2025-03-31 20:33
Modified
2025-04-03 17:42
Severity ?
VLAI Severity ?
EPSS score ?
Summary
An E-RAB Release Command packet containing a malformed NAS PDU will cause the Athonet MME to immediately crash, potentially due to a buffer overflow.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Hewlett Packard Enterprise (HPE) | HPE Athonet Core |
Version: HPE Athonet Core 11.0 ≤ 11.6 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-24456", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-31T21:20:22.440937Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-04-03T17:42:17.133Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "HPE Athonet Core", "vendor": "Hewlett Packard Enterprise (HPE)", "versions": [ { "lessThanOrEqual": "11.6", "status": "affected", "version": "HPE Athonet Core 11.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "This vulnerability was discovered by Bennett, N., Zhu, W., Simon, B., Kennedy, R., Enck, W., Traynor, P., Butler, K. (2024). RANsacked: A Domain-Informed Approach for Fuzzing LTE and 5G RAN-Core Interfaces. https://nathanielbennett.com/publications/ransacked.pdf" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn E-RAB Release Command packet containing a malformed NAS PDU\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ewill cause the Athonet MME to immediately crash, potentially due to a\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ebuffer overflow.\u003c/span\u003e\u003c/p\u003e" } ], "value": "An E-RAB Release Command packet containing a malformed NAS PDU\u00a0will cause the Athonet MME to immediately crash, potentially due to a\u00a0buffer overflow." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-31T20:33:05.688Z", "orgId": "eb103674-0d28-4225-80f8-39fb86215de0", "shortName": "hpe" }, "references": [ { "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04780en_us\u0026docLocale=en_US" } ], "source": { "advisory": "HPESBGN04780", "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0", "assignerShortName": "hpe", "cveId": "CVE-2024-24456", "datePublished": "2025-03-31T20:33:05.688Z", "dateReserved": "2024-01-25T09:13:34.119Z", "dateUpdated": "2025-04-03T17:42:17.133Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-24454 (GCVE-0-2024-24454)
Vulnerability from cvelistv5
Published
2024-11-15 00:00
Modified
2025-08-26 21:08
Severity ?
VLAI Severity ?
EPSS score ?
Summary
An invalid memory access when handling the ProtocolIE_ID field of E-RAB Modify Request messages in Athonet vEPC MME v11.4.0 allows attackers to cause a Denial of Service (DoS) to the cellular network by repeatedly initiating connections and sending a crafted payload.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Hewlett Packard Enterprise (HPE) | HPE Athonet Core |
Version: HPE Athonet Core 11.0 ≤ 11.6 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-24454", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-08-26T21:07:47.429383Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125 Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-26T21:08:36.197Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "HPE Athonet Core", "vendor": "Hewlett Packard Enterprise (HPE)", "versions": [ { "lessThanOrEqual": "11.6", "status": "affected", "version": "HPE Athonet Core 11.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "This vulnerability was discovered by Bennett, N., Zhu, W., Simon, B., Kennedy, R., Enck, W., Traynor, P., Butler, K. (2024). RANsacked: A Domain-Informed Approach for Fuzzing LTE and 5G RAN-Core Interfaces. https://nathanielbennett.com/publications/ransacked.pdf" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn invalid memory access when handling the ProtocolIE_ID field of\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eE-RAB Modify Request messages in Athonet vEPC MME v11.4.0\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eallows attackers to cause a Denial of Service (DoS) to the cellular\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003enetwork by repeatedly initiating connections and sending a crafted\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003epayload.\u003c/span\u003e\u003c/p\u003e" } ], "value": "An invalid memory access when handling the ProtocolIE_ID field of\u00a0E-RAB Modify Request messages in Athonet vEPC MME v11.4.0\u00a0allows attackers to cause a Denial of Service (DoS) to the cellular\u00a0network by repeatedly initiating connections and sending a crafted\u00a0payload." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-31T20:30:10.543Z", "orgId": "eb103674-0d28-4225-80f8-39fb86215de0", "shortName": "hpe" }, "references": [ { "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04780en_us\u0026docLocale=en_US" } ], "source": { "advisory": "HPESBGN04780", "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-24454", "datePublished": "2024-11-15T00:00:00.000Z", "dateReserved": "2024-01-25T00:00:00.000Z", "dateUpdated": "2025-08-26T21:08:36.197Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-24455 (GCVE-0-2024-24455)
Vulnerability from cvelistv5
Published
2024-11-15 00:00
Modified
2025-08-26 21:10
Severity ?
VLAI Severity ?
EPSS score ?
Summary
An invalid memory access when handling a UE Context Release message containing an invalid UE identifier in Athonet vEPC MME v11.4.0 allows attackers to cause a Denial of Service (DoS) to the cellular network by repeatedly initiating connections and sending a crafted payload.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Hewlett Packard Enterprise (HPE) | HPE Athonet Core |
Version: HPE Athonet Core 11.0 ≤ 11.6 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-24455", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-15T20:57:23.023027Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125 Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-26T21:10:12.027Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "HPE Athonet Core", "vendor": "Hewlett Packard Enterprise (HPE)", "versions": [ { "lessThanOrEqual": "11.6", "status": "affected", "version": "HPE Athonet Core 11.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "This vulnerability was discovered by Bennett, N., Zhu, W., Simon, B., Kennedy, R., Enck, W., Traynor, P., Butler, K. (2024). RANsacked: A Domain-Informed Approach for Fuzzing LTE and 5G RAN-Core Interfaces. https://nathanielbennett.com/publications/ransacked.pdf" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn invalid memory access when handling a UE Context Release message\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003econtaining an invalid UE identifier in Athonet vEPC MME v11.4.0 allows\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eattackers to cause a Denial of Service (DoS) to the cellular network\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eby repeatedly initiating connections and sending a crafted payload.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e\u003c/p\u003e" } ], "value": "An invalid memory access when handling a UE Context Release message\u00a0containing an invalid UE identifier in Athonet vEPC MME v11.4.0 allows\u00a0attackers to cause a Denial of Service (DoS) to the cellular network\u00a0by repeatedly initiating connections and sending a crafted payload." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-31T20:31:02.754Z", "orgId": "eb103674-0d28-4225-80f8-39fb86215de0", "shortName": "hpe" }, "references": [ { "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04780en_us\u0026docLocale=en_US" } ], "source": { "advisory": "HPESBGN04780", "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-24455", "datePublished": "2024-11-15T00:00:00.000Z", "dateReserved": "2024-01-25T00:00:00.000Z", "dateUpdated": "2025-08-26T21:10:12.027Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-24458 (GCVE-0-2024-24458)
Vulnerability from cvelistv5
Published
2024-11-15 00:00
Modified
2025-08-26 21:11
Severity ?
VLAI Severity ?
EPSS score ?
Summary
An invalid memory access when handling the ENB Configuration Transfer messages containing invalid PLMN Identities in Athonet vEPC MME v11.4.0 allows attackers to cause a Denial of Service (DoS) to the cellular network by repeatedly initiating connections and sending a crafted payload.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Hewlett Packard Enterprise (HPE) | HPE Athonet Core |
Version: HPE Athonet Core 11.0 ≤ 11.6 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-24458", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-15T20:49:54.796447Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125 Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-26T21:11:30.537Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "HPE Athonet Core", "vendor": "Hewlett Packard Enterprise (HPE)", "versions": [ { "lessThanOrEqual": "11.6", "status": "affected", "version": "HPE Athonet Core 11.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "This vulnerability was discovered by Bennett, N., Zhu, W., Simon, B., Kennedy, R., Enck, W., Traynor, P., Butler, K. (2024). RANsacked: A Domain-Informed Approach for Fuzzing LTE and 5G RAN-Core Interfaces. https://nathanielbennett.com/publications/ransacked.pdf" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn invalid memory access when handling the ENB Configuration Transfer\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003emessages containing invalid PLMN Identities in Athonet vEPC MME\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ev11.4.0 allows attackers to cause a Denial of Service (DoS) to the cellular\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003enetwork by repeatedly initiating connections and sending a crafted\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003epayload.\u003c/span\u003e\u003c/p\u003e" } ], "value": "An invalid memory access when handling the ENB Configuration Transfer\u00a0messages containing invalid PLMN Identities in Athonet vEPC MME\u00a0v11.4.0 allows attackers to cause a Denial of Service (DoS) to the cellular\u00a0network by repeatedly initiating connections and sending a crafted\u00a0payload." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-31T20:35:55.985Z", "orgId": "eb103674-0d28-4225-80f8-39fb86215de0", "shortName": "hpe" }, "references": [ { "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04780en_us\u0026docLocale=en_US" } ], "source": { "advisory": "HPESBGN04780", "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-24458", "datePublished": "2024-11-15T00:00:00.000Z", "dateReserved": "2024-01-25T00:00:00.000Z", "dateUpdated": "2025-08-26T21:11:30.537Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-24457 (GCVE-0-2024-24457)
Vulnerability from cvelistv5
Published
2024-11-15 00:00
Modified
2025-08-26 21:10
Severity ?
VLAI Severity ?
EPSS score ?
Summary
An invalid memory access when handling the ProtocolIE_ID field of E-RAB Setup List Context SURes messages in Athonet vEPC MME v11.4.0 allows attackers to cause a Denial of Service (DoS) to the cellular network by repeatedly initiating connections and sending a crafted payload.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Hewlett Packard Enterprise (HPE) | HPE Athonet Core |
Version: HPE Athonet Core 11.0 ≤ 11.6 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-24457", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-15T20:57:19.188520Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125 Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-26T21:10:55.385Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "HPE Athonet Core", "vendor": "Hewlett Packard Enterprise (HPE)", "versions": [ { "lessThanOrEqual": "11.6", "status": "affected", "version": "HPE Athonet Core 11.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "This vulnerability was discovered by Bennett, N., Zhu, W., Simon, B., Kennedy, R., Enck, W., Traynor, P., Butler, K. (2024). RANsacked: A Domain-Informed Approach for Fuzzing LTE and 5G RAN-Core Interfaces. https://nathanielbennett.com/publications/ransacked.pdf" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn invalid memory access when handling the ProtocolIE_ID field of E-RAB\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSetup List Context SURes messages in Athonet vEPC MME v11.4.0 allows\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eattackers to cause a Denial of Service (DoS) to the cellular network by\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003erepeatedly initiating connections and sending a crafted payload.\u003c/span\u003e\u003c/p\u003e" } ], "value": "An invalid memory access when handling the ProtocolIE_ID field of E-RAB\u00a0Setup List Context SURes messages in Athonet vEPC MME v11.4.0 allows\u00a0attackers to cause a Denial of Service (DoS) to the cellular network by\u00a0repeatedly initiating connections and sending a crafted payload." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-31T20:34:28.364Z", "orgId": "eb103674-0d28-4225-80f8-39fb86215de0", "shortName": "hpe" }, "references": [ { "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04780en_us\u0026docLocale=en_US" } ], "source": { "advisory": "HPESBGN04780", "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-24457", "datePublished": "2024-11-15T00:00:00.000Z", "dateReserved": "2024-01-25T00:00:00.000Z", "dateUpdated": "2025-08-26T21:10:55.385Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }