Vulnerabilites related to vivo - Framework
CVE-2020-12491 (GCVE-0-2020-12491)
Vulnerability from cvelistv5
Published
2024-11-25 10:08
Modified
2024-11-25 17:03
CWE
  • CWE-306 - Missing Authentication for Critical Function
Summary
Improper control of framework service permissions with possibility of some sensitive device information leakage.
Impacted products
Vendor Product Version
vivo Framework Version: ard11 and below versions released before 2022.2.24
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-12491",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-25T17:02:53.241577Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-25T17:03:03.193Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Framework",
          "vendor": "vivo",
          "versions": [
            {
              "status": "affected",
              "version": "ard11 and below versions released before 2022.2.24"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper control of framework service permissions with possibility of some sensitive device information leakage.\u003cbr\u003e"
            }
          ],
          "value": "Improper control of framework service permissions with possibility of some sensitive device information leakage."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-25T10:08:14.791Z",
        "orgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
        "shortName": "Vivo"
      },
      "references": [
        {
          "url": "https://www.vivo.com/en/support/security-advisory-detail?id=11"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Framework Information Disclosure Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
    "assignerShortName": "Vivo",
    "cveId": "CVE-2020-12491",
    "datePublished": "2024-11-25T10:08:14.791Z",
    "dateReserved": "2020-04-30T00:00:00.000Z",
    "dateUpdated": "2024-11-25T17:03:03.193Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-12492 (GCVE-0-2020-12492)
Vulnerability from cvelistv5
Published
2024-11-25 10:11
Modified
2024-11-25 17:02
CWE
  • CWE-306 - Missing Authentication for Critical Function
Summary
Improper handling of WiFi information by framework services can allow certain malicious applications to obtain sensitive information.
Impacted products
Vendor Product Version
vivo Framework Version: ard11 and below versions released before 2022.2.24
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-12492",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-25T17:02:20.383757Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-25T17:02:32.200Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Framework",
          "vendor": "vivo",
          "versions": [
            {
              "status": "affected",
              "version": "ard11 and below versions released before 2022.2.24"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper handling of WiFi information by framework services can allow certain malicious applications to obtain sensitive information.\u003cbr\u003e"
            }
          ],
          "value": "Improper handling of WiFi information by framework services can allow certain malicious applications to obtain sensitive information."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "LOCAL",
            "baseScore": 1,
            "baseSeverity": "LOW",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:P/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-25T10:11:30.761Z",
        "orgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
        "shortName": "Vivo"
      },
      "references": [
        {
          "url": "https://www.vivo.com/en/support/security-advisory-detail?id=12"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Wifi information acquisition vulnerability in Framework Services",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
    "assignerShortName": "Vivo",
    "cveId": "CVE-2020-12492",
    "datePublished": "2024-11-25T10:11:30.761Z",
    "dateReserved": "2020-04-30T00:00:00.000Z",
    "dateUpdated": "2024-11-25T17:02:32.200Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}