Vulnerabilites related to Schneider Electric - EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards Module
CVE-2025-54927 (GCVE-0-2025-54927)
Vulnerability from cvelistv5
Published
2025-08-20 13:51
Modified
2025-08-20 17:21
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized access to sensitive files when an authenticated attackers uses a crafted path input that is processed by the system.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | EcoStruxure™ Power Monitoring Expert (PME) |
Version: Version 2022 Version: Version 2023 Version: Version 2024 Version: Version 2024 R2 |
||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-54927", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-08-20T17:21:22.824724Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-08-20T17:21:29.791Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EcoStruxure\u2122 Power Monitoring Expert (PME)", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2022" }, { "status": "affected", "version": "Version 2023" }, { "status": "affected", "version": "Version 2024" }, { "status": "affected", "version": "Version 2024 R2" } ] }, { "defaultStatus": "unaffected", "product": "EcoStruxure\u2122 Power Operation (EPO) Advanced Reporting and Dashboards Module", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2022 w/ Advanced Reporting Module" }, { "status": "affected", "version": "Version 2024 w/ Advanced Reporting Module" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause unauthorized access to sensitive files when an authenticated attackers uses a crafted path input that is processed by the system." } ], "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause unauthorized access to sensitive files when an authenticated attackers uses a crafted path input that is processed by the system." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-20T13:51:04.959Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2025-54927", "datePublished": "2025-08-20T13:51:04.959Z", "dateReserved": "2025-08-01T04:38:47.036Z", "dateUpdated": "2025-08-20T17:21:29.791Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-54924 (GCVE-0-2025-54924)
Vulnerability from cvelistv5
Published
2025-08-20 13:39
Modified
2025-08-20 17:22
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Summary
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | EcoStruxure™ Power Monitoring Expert (PME) |
Version: Version 2022 Version: Version 2023 Version: Version 2024 Version: Version 2024 R2 |
||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-54924", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-08-20T17:22:28.618615Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-08-20T17:22:38.019Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EcoStruxure\u2122 Power Monitoring Expert (PME)", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2022" }, { "status": "affected", "version": "Version 2023" }, { "status": "affected", "version": "Version 2024" }, { "status": "affected", "version": "Version 2024 R2" } ] }, { "defaultStatus": "unaffected", "product": "EcoStruxure\u2122 Power Operation (EPO) Advanced Reporting and Dashboards Module", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2022 w/ Advanced Reporting Module" }, { "status": "affected", "version": "Version 2024 w/ Advanced Reporting Module" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint." } ], "value": "CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-918", "description": "CWE-918 Server-Side Request Forgery (SSRF)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-20T13:44:53.863Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2025-54924", "datePublished": "2025-08-20T13:39:10.986Z", "dateReserved": "2025-08-01T04:38:47.036Z", "dateUpdated": "2025-08-20T17:22:38.019Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-54925 (GCVE-0-2025-54925)
Vulnerability from cvelistv5
Published
2025-08-20 13:44
Modified
2025-08-20 17:22
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Summary
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | EcoStruxure™ Power Monitoring Expert (PME) |
Version: Version 2022 Version: Version 2023 Version: Version 2024 Version: Version 2024 R2 |
||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-54925", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-08-20T17:22:07.997830Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-08-20T17:22:14.962Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EcoStruxure\u2122 Power Monitoring Expert (PME)", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2022" }, { "status": "affected", "version": "Version 2023" }, { "status": "affected", "version": "Version 2024" }, { "status": "affected", "version": "Version 2024 R2" } ] }, { "defaultStatus": "unaffected", "product": "EcoStruxure\u2122 Power Operation (EPO) Advanced Reporting and Dashboards Module", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2022 w/ Advanced Reporting Module" }, { "status": "affected", "version": "Version 2024 w/ Advanced Reporting Module" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url." } ], "value": "CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-918", "description": "CWE-918 Server-Side Request Forgery (SSRF)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-20T13:44:21.662Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2025-54925", "datePublished": "2025-08-20T13:44:21.662Z", "dateReserved": "2025-08-01T04:38:47.036Z", "dateUpdated": "2025-08-20T17:22:14.962Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-54923 (GCVE-0-2025-54923)
Vulnerability from cvelistv5
Published
2025-08-20 13:30
Modified
2025-08-20 17:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-502 - Deserialization of Untrusted Data
Summary
CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution and compromise of system integrity when authenticated users send crafted data to a network-exposed service that performs unsafe deserialization.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | EcoStruxure™ Power Monitoring Expert (PME) |
Version: Version 2022 Version: Version 2023 Version: Version 2024 Version: Version 2024 R2 |
||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-54923", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-08-20T17:22:56.459372Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-08-20T17:23:04.154Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EcoStruxure\u2122 Power Monitoring Expert (PME)", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2022" }, { "status": "affected", "version": "Version 2023" }, { "status": "affected", "version": "Version 2024" }, { "status": "affected", "version": "Version 2024 R2" } ] }, { "defaultStatus": "unaffected", "product": "EcoStruxure\u2122 Power Operation (EPO) Advanced Reporting and Dashboards Module", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2022 w/ Advanced Reporting Module" }, { "status": "affected", "version": "Version 2024 w/ Advanced Reporting Module" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution and compromise of system integrity when authenticated users send crafted data to a network-exposed service that performs unsafe deserialization." } ], "value": "CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution and compromise of system integrity when authenticated users send crafted data to a network-exposed service that performs unsafe deserialization." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 8.7, "baseSeverity": "HIGH", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-502", "description": "CWE-502 Deserialization of Untrusted Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-20T13:44:42.905Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2025-54923", "datePublished": "2025-08-20T13:30:04.988Z", "dateReserved": "2025-08-01T04:38:47.036Z", "dateUpdated": "2025-08-20T17:23:04.154Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-54926 (GCVE-0-2025-54926)
Vulnerability from cvelistv5
Published
2025-08-20 13:48
Modified
2025-08-20 17:21
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | EcoStruxure™ Power Monitoring Expert (PME) |
Version: Version 2022 Version: Version 2023 Version: Version 2024 Version: Version 2024 R2 |
||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-54926", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-08-20T17:21:43.158876Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-08-20T17:21:50.700Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EcoStruxure\u2122 Power Monitoring Expert (PME)", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2022" }, { "status": "affected", "version": "Version 2023" }, { "status": "affected", "version": "Version 2024" }, { "status": "affected", "version": "Version 2024 R2" } ] }, { "defaultStatus": "unaffected", "product": "EcoStruxure\u2122 Power Operation (EPO) Advanced Reporting and Dashboards Module", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2022 w/ Advanced Reporting Module" }, { "status": "affected", "version": "Version 2024 w/ Advanced Reporting Module" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed." } ], "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-20T13:48:02.393Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2025-54926", "datePublished": "2025-08-20T13:48:02.393Z", "dateReserved": "2025-08-01T04:38:47.036Z", "dateUpdated": "2025-08-20T17:21:50.700Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }