Vulnerabilites related to Dell - Dell Precision Rack BIOS
CVE-2024-42425 (GCVE-0-2024-42425)
Vulnerability from cvelistv5
Published
2024-09-10 08:17
Modified
2024-09-10 15:08
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-788 - Access of Memory Location After End of Buffer
Summary
Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.
References
| ▼ | URL | Tags |
|---|---|---|
| https://www.dell.com/support/kbdoc/en-us/000227015/dsa-2024-328 | vendor-advisory |
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Dell Precision Rack BIOS |
Version: N/A ≤ |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-42425",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T15:08:42.622659Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T15:08:54.037Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Dell Precision Rack BIOS",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.22.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2024-09-05T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-788",
"description": "CWE-788: Access of Memory Location After End of Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T08:17:04.690Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000227015/dsa-2024-328"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-42425",
"datePublished": "2024-09-10T08:17:04.690Z",
"dateReserved": "2024-08-01T07:28:53.702Z",
"dateUpdated": "2024-09-10T15:08:54.037Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-42424 (GCVE-0-2024-42424)
Vulnerability from cvelistv5
Published
2024-09-10 08:05
Modified
2024-09-10 15:11
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-20 - Improper Input Validation
Summary
Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Improper Input Validation vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.
References
| ▼ | URL | Tags |
|---|---|---|
| https://www.dell.com/support/kbdoc/en-us/000227014/dsa-2024-327 | vendor-advisory |
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Dell Precision Rack BIOS |
Version: N/A ≤ |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-42424",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T15:09:15.219185Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T15:11:45.356Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Dell Precision Rack BIOS",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.22.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2024-09-05T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Improper Input Validation vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Improper Input Validation vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T08:05:43.080Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000227014/dsa-2024-327"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-42424",
"datePublished": "2024-09-10T08:05:43.080Z",
"dateReserved": "2024-08-01T07:28:53.701Z",
"dateUpdated": "2024-09-10T15:11:45.356Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}