Vulnerabilites related to hikvision - DS-A71024/48R-CVS,DS-A72024/48R-CVS
CVE-2022-28172 (GCVE-0-2022-28172)
Vulnerability from cvelistv5
Published
2022-06-27 17:50
Modified
2024-09-17 01:10
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Cross-site Scripting (XSS)
Summary
The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to XSS attack by sending messages with malicious commands to the affected device.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | hikvision | DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D |
Version: V2.X < |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:48:37.258Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D", "vendor": "hikvision", "versions": [ { "lessThanOrEqual": "V2.3.8-6", "status": "affected", "version": "V2.X", "versionType": "custom" } ] }, { "product": "DS-A71024/48R-CVS,DS-A72024/48R-CVS", "vendor": "hikvision", "versions": [ { "lessThanOrEqual": "V1.1.4", "status": "affected", "version": "V1.X", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Thurein Soe" } ], "datePublic": "2022-06-23T00:00:00", "descriptions": [ { "lang": "en", "value": "The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to XSS attack by sending messages with malicious commands to the affected device." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79 Cross-site Scripting (XSS)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-31T00:00:00", "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32", "shortName": "hikvision" }, "references": [ { "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/" }, { "url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html" } ], "solutions": [ { "lang": "en", "value": "https://www.hikvision.com/content/dam/hikvision/en/support/cybersecyrity/security-advisory/Patch-for-Fixing-Security-Vulnerability-of-Hybrid-SAN-\u0026-Cluster-Storage.zip" } ], "source": { "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32", "assignerShortName": "hikvision", "cveId": "CVE-2022-28172", "datePublished": "2022-06-27T17:50:40.922725Z", "dateReserved": "2022-03-29T00:00:00", "dateUpdated": "2024-09-17T01:10:46.622Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-28171 (GCVE-0-2022-28171)
Vulnerability from cvelistv5
Published
2022-06-27 17:48
Modified
2024-09-16 17:03
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - OS Command Injection
Summary
The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to execute restricted commands by sending messages with malicious commands to the affected device.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | hikvision | DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D |
Version: V2.X < |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:48:37.209Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/173653/Hikvision-Hybrid-SAN-Ds-a71024-SQL-Injection.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D", "vendor": "hikvision", "versions": [ { "lessThanOrEqual": "V2.3.8-6", "status": "affected", "version": "V2.X", "versionType": "custom" } ] }, { "product": "DS-A71024/48R-CVS,DS-A72024/48R-CVS", "vendor": "hikvision", "versions": [ { "lessThanOrEqual": "V1.1.4", "status": "affected", "version": "V1.X", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Thurein Soe" } ], "datePublic": "2022-06-23T00:00:00", "descriptions": [ { "lang": "en", "value": "The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to execute restricted commands by sending messages with malicious commands to the affected device." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 OS Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-20T00:00:00", "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32", "shortName": "hikvision" }, "references": [ { "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/" }, { "url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html" }, { "url": "http://packetstormsecurity.com/files/173653/Hikvision-Hybrid-SAN-Ds-a71024-SQL-Injection.html" } ], "solutions": [ { "lang": "en", "value": "https://www.hikvision.com/content/dam/hikvision/en/support/cybersecyrity/security-advisory/Patch-for-Fixing-Security-Vulnerability-of-Hybrid-SAN-\u0026-Cluster-Storage.zip" } ], "source": { "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32", "assignerShortName": "hikvision", "cveId": "CVE-2022-28171", "datePublished": "2022-06-27T17:48:51.569864Z", "dateReserved": "2022-03-29T00:00:00", "dateUpdated": "2024-09-16T17:03:49.464Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-28808 (GCVE-0-2023-28808)
Vulnerability from cvelistv5
Published
2023-04-11 00:00
Modified
2025-02-07 19:35
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-284 - Improper Access Control
Summary
Some Hikvision Hybrid SAN/Cluster Storage products have an access control vulnerability which can be used to obtain the admin permission. The attacker can exploit the vulnerability by sending crafted messages to the affected devices.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | hikvision | DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D |
Version: V2.X < |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T13:51:38.489Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-cluster-stor/" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-28808", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-07T19:35:09.080119Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-07T19:35:13.163Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D", "vendor": "hikvision", "versions": [ { "lessThanOrEqual": "V2.3.8-8", "status": "affected", "version": "V2.X", "versionType": "custom" } ] }, { "product": "DS-A71024/48R-CVS,DS-A72024/48R-CVS", "vendor": "hikvision", "versions": [ { "lessThanOrEqual": "V1.1.4 ", "status": "affected", "version": "V1.X", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Souvik Kandar, Arko Dhar" } ], "datePublic": "2023-04-11T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "Some Hikvision Hybrid SAN/Cluster Storage products have an access control vulnerability which can be used to obtain the admin permission. The attacker can exploit the vulnerability by sending crafted messages to the affected devices." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284 Improper Access Control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-11T00:00:00.000Z", "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32", "shortName": "hikvision" }, "references": [ { "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-cluster-stor/" } ], "solutions": [ { "lang": "en", "value": "https://www.hikvision.com/content/dam/hikvision/en/support/notice/security-notification-23-4-10/Fixing-Security-Vulnerability-of-Hybrid-SAN-230407.zip" } ], "source": { "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32", "assignerShortName": "hikvision", "cveId": "CVE-2023-28808", "datePublished": "2023-04-11T00:00:00.000Z", "dateReserved": "2023-03-23T00:00:00.000Z", "dateUpdated": "2025-02-07T19:35:13.163Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }