All the vulnerabilites related to Delta Electronics - DOPSoft 2
cve-2021-38402
Vulnerability from cvelistv5
Published
2021-09-17 18:54
Modified
2024-09-17 02:56
Summary
Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could lead to a stack-based buffer overflow while trying to copy to a buffer during font string handling. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:37:16.542Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DOPSoft 2",
          "vendor": "Delta Electronics",
          "versions": [
            {
              "lessThanOrEqual": "2.00.07",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative"
        }
      ],
      "datePublic": "2021-09-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could lead to a stack-based buffer overflow while trying to copy to a buffer during font string handling. An attacker could leverage this vulnerability to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-17T18:54:37",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "DOPSoft 2 will not receive an update to mitigate these vulnerabilities because it is an end-of-life product. Delta Electronics recommends users to switch to the replacement software when available"
        }
      ],
      "source": {
        "advisory": "ICSA-21-252-02",
        "discovery": "UNKNOWN"
      },
      "title": "Delta Electronics DOPSoft 2 Stack-Based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2021-09-09T14:34:00.000Z",
          "ID": "CVE-2021-38402",
          "STATE": "PUBLIC",
          "TITLE": "Delta Electronics DOPSoft 2 Stack-Based Buffer Overflow"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DOPSoft 2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "2.00.07"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Delta Electronics"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could lead to a stack-based buffer overflow while trying to copy to a buffer during font string handling. An attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121 Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "DOPSoft 2 will not receive an update to mitigate these vulnerabilities because it is an end-of-life product. Delta Electronics recommends users to switch to the replacement software when available"
          }
        ],
        "source": {
          "advisory": "ICSA-21-252-02",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38402",
    "datePublished": "2021-09-17T18:54:37.590021Z",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-09-17T02:56:52.553Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-38404
Vulnerability from cvelistv5
Published
2021-09-17 18:54
Modified
2024-09-17 01:50
Summary
Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:37:16.563Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DOPSoft 2",
          "vendor": "Delta Electronics",
          "versions": [
            {
              "lessThanOrEqual": "2.00.07",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative"
        }
      ],
      "datePublic": "2021-09-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122 Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-17T18:54:45",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "DOPSoft 2 will not receive an update to mitigate these vulnerabilities because it is an end-of-life product. Delta Electronics recommends users to switch to the replacement software when available"
        }
      ],
      "source": {
        "advisory": "ICSA-21-252-02",
        "discovery": "UNKNOWN"
      },
      "title": "Delta Electronics DOPSoft 2 Heap-based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2021-09-09T14:34:00.000Z",
          "ID": "CVE-2021-38404",
          "STATE": "PUBLIC",
          "TITLE": "Delta Electronics DOPSoft 2 Heap-based Buffer Overflow"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DOPSoft 2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "2.00.07"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Delta Electronics"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-122 Heap-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "DOPSoft 2 will not receive an update to mitigate these vulnerabilities because it is an end-of-life product. Delta Electronics recommends users to switch to the replacement software when available"
          }
        ],
        "source": {
          "advisory": "ICSA-21-252-02",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38404",
    "datePublished": "2021-09-17T18:54:45.055664Z",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-09-17T01:50:51.298Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-38406
Vulnerability from cvelistv5
Published
2021-09-17 18:54
Modified
2024-09-17 03:48
Summary
Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in multiple out-of-bounds write instances. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:37:16.611Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DOPSoft 2",
          "vendor": "Delta Electronics",
          "versions": [
            {
              "lessThanOrEqual": "2.00.07",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative"
        }
      ],
      "datePublic": "2021-09-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in multiple out-of-bounds write instances. An attacker could leverage this vulnerability to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-17T18:54:29",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "DOPSoft 2 will not receive an update to mitigate these vulnerabilities because it is an end-of-life product. Delta Electronics recommends users to switch to the replacement software when available"
        }
      ],
      "source": {
        "advisory": "ICSA-21-252-02",
        "discovery": "UNKNOWN"
      },
      "title": "Delta Electronics DOPSoft 2 Out-of-Bounds Write",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2021-09-09T14:34:00.000Z",
          "ID": "CVE-2021-38406",
          "STATE": "PUBLIC",
          "TITLE": "Delta Electronics DOPSoft 2 Out-of-Bounds Write"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DOPSoft 2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "2.00.07"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Delta Electronics"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in multiple out-of-bounds write instances. An attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787 Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "DOPSoft 2 will not receive an update to mitigate these vulnerabilities because it is an end-of-life product. Delta Electronics recommends users to switch to the replacement software when available"
          }
        ],
        "source": {
          "advisory": "ICSA-21-252-02",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38406",
    "datePublished": "2021-09-17T18:54:29.386324Z",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-09-17T03:48:12.499Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",