Summary
Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could lead to a stack-based buffer overflow while trying to copy to a buffer during font string handling. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
▼ | URL | Tags |
---|---|---|
https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Delta Electronics | DOPSoft 2 |
Version: unspecified < |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T01:37:16.542Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "DOPSoft 2", "vendor": "Delta Electronics", "versions": [ { "lessThanOrEqual": "2.00.07", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative" } ], "datePublic": "2021-09-09T00:00:00", "descriptions": [ { "lang": "en", "value": "Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could lead to a stack-based buffer overflow while trying to copy to a buffer during font string handling. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-17T18:54:37", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02" } ], "solutions": [ { "lang": "en", "value": "DOPSoft 2 will not receive an update to mitigate these vulnerabilities because it is an end-of-life product. Delta Electronics recommends users to switch to the replacement software when available" } ], "source": { "advisory": "ICSA-21-252-02", "discovery": "UNKNOWN" }, "title": "Delta Electronics DOPSoft 2 Stack-Based Buffer Overflow", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2021-09-09T14:34:00.000Z", "ID": "CVE-2021-38402", "STATE": "PUBLIC", "TITLE": "Delta Electronics DOPSoft 2 Stack-Based Buffer Overflow" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "DOPSoft 2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "2.00.07" } ] } } ] }, "vendor_name": "Delta Electronics" } ] } }, "credit": [ { "lang": "eng", "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could lead to a stack-based buffer overflow while trying to copy to a buffer during font string handling. An attacker could leverage this vulnerability to execute code in the context of the current process." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-121 Stack-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02" } ] }, "solution": [ { "lang": "en", "value": "DOPSoft 2 will not receive an update to mitigate these vulnerabilities because it is an end-of-life product. Delta Electronics recommends users to switch to the replacement software when available" } ], "source": { "advisory": "ICSA-21-252-02", "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-38402", "datePublished": "2021-09-17T18:54:37.590021Z", "dateReserved": "2021-08-10T00:00:00", "dateUpdated": "2024-09-17T02:56:52.553Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-38404
Vulnerability from cvelistv5
Published
2021-09-17 18:54
Modified
2024-09-17 01:50
Severity ?
EPSS score ?
Summary
Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
▼ | URL | Tags |
---|---|---|
https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Delta Electronics | DOPSoft 2 |
Version: unspecified < |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T01:37:16.563Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "DOPSoft 2", "vendor": "Delta Electronics", "versions": [ { "lessThanOrEqual": "2.00.07", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative" } ], "datePublic": "2021-09-09T00:00:00", "descriptions": [ { "lang": "en", "value": "Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122 Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-17T18:54:45", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02" } ], "solutions": [ { "lang": "en", "value": "DOPSoft 2 will not receive an update to mitigate these vulnerabilities because it is an end-of-life product. Delta Electronics recommends users to switch to the replacement software when available" } ], "source": { "advisory": "ICSA-21-252-02", "discovery": "UNKNOWN" }, "title": "Delta Electronics DOPSoft 2 Heap-based Buffer Overflow", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2021-09-09T14:34:00.000Z", "ID": "CVE-2021-38404", "STATE": "PUBLIC", "TITLE": "Delta Electronics DOPSoft 2 Heap-based Buffer Overflow" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "DOPSoft 2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "2.00.07" } ] } } ] }, "vendor_name": "Delta Electronics" } ] } }, "credit": [ { "lang": "eng", "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-122 Heap-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02" } ] }, "solution": [ { "lang": "en", "value": "DOPSoft 2 will not receive an update to mitigate these vulnerabilities because it is an end-of-life product. Delta Electronics recommends users to switch to the replacement software when available" } ], "source": { "advisory": "ICSA-21-252-02", "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-38404", "datePublished": "2021-09-17T18:54:45.055664Z", "dateReserved": "2021-08-10T00:00:00", "dateUpdated": "2024-09-17T01:50:51.298Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-38406
Vulnerability from cvelistv5
Published
2021-09-17 18:54
Modified
2024-09-17 03:48
Severity ?
EPSS score ?
Summary
Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in multiple out-of-bounds write instances. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
▼ | URL | Tags |
---|---|---|
https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Delta Electronics | DOPSoft 2 |
Version: unspecified < |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T01:37:16.611Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "DOPSoft 2", "vendor": "Delta Electronics", "versions": [ { "lessThanOrEqual": "2.00.07", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative" } ], "datePublic": "2021-09-09T00:00:00", "descriptions": [ { "lang": "en", "value": "Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in multiple out-of-bounds write instances. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-17T18:54:29", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02" } ], "solutions": [ { "lang": "en", "value": "DOPSoft 2 will not receive an update to mitigate these vulnerabilities because it is an end-of-life product. Delta Electronics recommends users to switch to the replacement software when available" } ], "source": { "advisory": "ICSA-21-252-02", "discovery": "UNKNOWN" }, "title": "Delta Electronics DOPSoft 2 Out-of-Bounds Write", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2021-09-09T14:34:00.000Z", "ID": "CVE-2021-38406", "STATE": "PUBLIC", "TITLE": "Delta Electronics DOPSoft 2 Out-of-Bounds Write" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "DOPSoft 2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "2.00.07" } ] } } ] }, "vendor_name": "Delta Electronics" } ] } }, "credit": [ { "lang": "eng", "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in multiple out-of-bounds write instances. An attacker could leverage this vulnerability to execute code in the context of the current process." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-787 Out-of-bounds Write" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02" } ] }, "solution": [ { "lang": "en", "value": "DOPSoft 2 will not receive an update to mitigate these vulnerabilities because it is an end-of-life product. Delta Electronics recommends users to switch to the replacement software when available" } ], "source": { "advisory": "ICSA-21-252-02", "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-38406", "datePublished": "2021-09-17T18:54:29.386324Z", "dateReserved": "2021-08-10T00:00:00", "dateUpdated": "2024-09-17T03:48:12.499Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }