Vulnerabilites related to Delta Industrial Automation - DIALink
CVE-2022-2969 (GCVE-0-2022-2969)
Vulnerability from cvelistv5
Published
2022-12-01 17:08
Modified
2025-04-16 16:05
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-22 - Path Traversa
Summary
Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Delta Industrial Automation | DIALink |
Version: 0 < 1.5.0.0 Beta 4 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T00:53:00.680Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-307-03" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-2969", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-04-16T15:49:14.906906Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-04-16T16:05:33.867Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "DIALink", "vendor": "Delta Industrial Automation", "versions": [ { "lessThan": "1.5.0.0 Beta 4", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Y4er, working with Trend Micro Zero Day Initiative, reported this vulnerability to CISA." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory." } ], "value": "Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Path Traversa", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-01T17:08:19.327Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-307-03" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Industrial Automation has created v1.5.0.0 Beta 4 to address this vulnerability. Delta Industrial Automation will not make this update an official release; users may obtain this updated version via Delta field application engineering (FAEs) or contacting Delta Industrial Automation directly.\u003c/span\u003e\n\n\u003cbr\u003e" } ], "value": "\nDelta Industrial Automation has created v1.5.0.0 Beta 4 to address this vulnerability. Delta Industrial Automation will not make this update an official release; users may obtain this updated version via Delta field application engineering (FAEs) or contacting Delta Industrial Automation directly.\n\n\n" } ], "source": { "discovery": "UNKNOWN" }, "title": "ICSA-22-307-03 Delta Industrial Automation DIALink Path traversal", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2022-2969", "datePublished": "2022-12-01T17:08:19.327Z", "dateReserved": "2022-08-23T15:43:56.589Z", "dateUpdated": "2025-04-16T16:05:33.867Z", "requesterUserId": "bc31a57b-b1a5-40e2-9263-67c0ae8a3b8a", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }