CVE-2025-3699 (GCVE-0-2025-3699)
Vulnerability from nvd
Published
2025-06-26 22:40
Modified
2025-12-23 03:45
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3699",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-01T19:23:59.612308Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-01T19:24:14.966Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "G-50",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "G-50-W",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "G-50A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GB-50",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GB-50A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GB-24A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "G-150AD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AG-150A-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AG-150A-J",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GB-50AD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GB-50ADA-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GB-50ADA-J",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EB-50GU-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EB-50GU-J",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AE-200J",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AE-200A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AE-200E",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AE-50J",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AE-50A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AE-50E",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EW-50J",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EW-50A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EW-50E",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TE-200A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TE-50A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TW-50A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CMS-RMD-J",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information.\u003cbr\u003e"
}
],
"value": "Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-23T03:45:00.790Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-004_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96471539/"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-177-01"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2025-3699",
"datePublished": "2025-06-26T22:40:37.915Z",
"dateReserved": "2025-04-16T04:10:19.080Z",
"dateUpdated": "2025-12-23T03:45:00.790Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-3699 (GCVE-0-2025-3699)
Vulnerability from cvelistv5
Published
2025-06-26 22:40
Modified
2025-12-23 03:45
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric Corporation | G-50 |
Version: All versions |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3699",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-01T19:23:59.612308Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-01T19:24:14.966Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "G-50",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "G-50-W",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "G-50A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GB-50",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GB-50A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GB-24A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "G-150AD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AG-150A-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AG-150A-J",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GB-50AD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GB-50ADA-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GB-50ADA-J",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EB-50GU-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EB-50GU-J",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AE-200J",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AE-200A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AE-200E",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AE-50J",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AE-50A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AE-50E",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EW-50J",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EW-50A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EW-50E",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TE-200A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TE-50A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TW-50A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CMS-RMD-J",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information.\u003cbr\u003e"
}
],
"value": "Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-23T03:45:00.790Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-004_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96471539/"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-177-01"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2025-3699",
"datePublished": "2025-06-26T22:40:37.915Z",
"dateReserved": "2025-04-16T04:10:19.080Z",
"dateUpdated": "2025-12-23T03:45:00.790Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}