All the vulnerabilites related to Siemens - Automation License Manager V6
cve-2022-43514
Vulnerability from cvelistv5
Published
2023-01-10 11:39
Modified
2024-08-03 13:32
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6 (All versions < V6.0 SP9 Upd4), TeleControl Server Basic V3 (All versions < V3.1.2). The affected component does not correctly validate the root path on folder related operations, allowing to modify files and folders outside the intended root directory.
This could allow an unauthenticated remote attacker to execute file operations of files outside of the specified root folder. Chained with CVE-2022-43513 this could allow Remote Code Execution.
References
Impacted products
Vendor | Product | Version | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Automation License Manager V5 |
Version: 0 < * |
||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:32:59.618Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-476715.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-476715.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-556635.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Automation License Manager V5", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Automation License Manager V6", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.0 SP9 Upd4" } ] }, { "defaultStatus": "unknown", "product": "TeleControl Server Basic V3", "vendor": "Siemens", "versions": [ { "lessThan": "V3.1.2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6 (All versions \u003c V6.0 SP9 Upd4), TeleControl Server Basic V3 (All versions \u003c V3.1.2). The affected component does not correctly validate the root path on folder related operations, allowing to modify files and folders outside the intended root directory.\r\nThis could allow an unauthenticated remote attacker to execute file operations of files outside of the specified root folder. Chained with CVE-2022-43513 this could allow Remote Code Execution." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.7, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-09T08:34:30.153Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-476715.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-476715.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-556635.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-43514", "datePublished": "2023-01-10T11:39:39.909Z", "dateReserved": "2022-10-19T13:06:48.747Z", "dateUpdated": "2024-08-03T13:32:59.618Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-43513
Vulnerability from cvelistv5
Published
2023-01-10 11:39
Modified
2024-08-03 13:32
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6 (All versions < V6.0 SP9 Upd4), TeleControl Server Basic V3 (All versions < V3.1.2). The affected components allow to rename license files with user chosen input without authentication.
This could allow an unauthenticated remote attacker to rename and move files as SYSTEM user.
References
Impacted products
Vendor | Product | Version | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Automation License Manager V5 |
Version: 0 < * |
||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:32:59.664Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-476715.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-476715.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-556635.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Automation License Manager V5", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Automation License Manager V6", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.0 SP9 Upd4" } ] }, { "defaultStatus": "unknown", "product": "TeleControl Server Basic V3", "vendor": "Siemens", "versions": [ { "lessThan": "V3.1.2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6 (All versions \u003c V6.0 SP9 Upd4), TeleControl Server Basic V3 (All versions \u003c V3.1.2). The affected components allow to rename license files with user chosen input without authentication.\r\nThis could allow an unauthenticated remote attacker to rename and move files as SYSTEM user." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-73", "description": "CWE-73: External Control of File Name or Path", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-09T08:34:28.633Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-476715.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-476715.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-556635.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-43513", "datePublished": "2023-01-10T11:39:38.879Z", "dateReserved": "2022-10-19T13:06:48.747Z", "dateUpdated": "2024-08-03T13:32:59.664Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }