Refine your search
2 vulnerabilities found for Archer C50 V3 by TP-Link System Inc.
CVE-2025-6982 (GCVE-0-2025-6982)
Vulnerability from nvd
Published
2025-07-16 20:01
Modified
2025-11-03 20:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-798 - Use of Hard-coded Credentials
Summary
Use of Hard-coded Credentials in TP-Link Archer C50 V3(
<=
180703)/V4(
<=
250117
)/V5(
<=
200407
), allows attackers to decrypt the config.xml files.
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TP-Link System Inc. | Archer C50 V3 |
Version: 0 |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6982",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-18T14:20:25.297362Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-18T14:20:32.075Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T20:07:18.484Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.kb.cert.org/vuls/id/554637"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Archer C50 V3",
"vendor": "TP-Link System Inc.",
"versions": [
{
"lessThanOrEqual": "180703",
"status": "affected",
"version": "0",
"versionType": "date"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Archer C50 V4",
"vendor": "TP-Link System Inc.",
"versions": [
{
"lessThanOrEqual": "250117",
"status": "affected",
"version": "0",
"versionType": "date"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Archer C50 V5",
"vendor": "TP-Link System Inc.",
"versions": [
{
"lessThanOrEqual": "200407",
"status": "affected",
"version": "0",
"versionType": "date"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Jai Bhortake (Organization: CoE - CNDS Lab, VJTI, Mumbai, India)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Use of Hard-coded Credentials in TP-Link Archer C50 V3(\n\n\u003cb\u003e\u0026lt;=\u003c/b\u003e\n\n180703)/V4(\n\n\n\n\u003cb\u003e\u0026lt;=\u003c/b\u003e\n\n250117\n\n)/V5(\n\n\n\n\u003cb\u003e\u0026lt;=\u003c/b\u003e\n\n200407\n\n),\u0026nbsp;\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eallows attackers to decrypt the config.xml files.\u0026nbsp;\u003c/span\u003e"
}
],
"value": "Use of Hard-coded Credentials in TP-Link Archer C50 V3(\n\n\u003c=\n\n180703)/V4(\n\n\n\n\u003c=\n\n250117\n\n)/V5(\n\n\n\n\u003c=\n\n200407\n\n),\u00a0allows attackers to decrypt the config.xml files."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-17T18:43:37.642Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"url": "https://www.tp-link.com/us/support/faq/4538/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"tags": [
"unsupported-when-assigned"
],
"title": "Hardcoded DES Decryption Keys in TP-Link Archer C50 V3/V4/V5",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-6982",
"datePublished": "2025-07-16T20:01:41.382Z",
"dateReserved": "2025-07-01T20:09:03.975Z",
"dateUpdated": "2025-11-03T20:07:18.484Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-6982 (GCVE-0-2025-6982)
Vulnerability from cvelistv5
Published
2025-07-16 20:01
Modified
2025-11-03 20:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-798 - Use of Hard-coded Credentials
Summary
Use of Hard-coded Credentials in TP-Link Archer C50 V3(
<=
180703)/V4(
<=
250117
)/V5(
<=
200407
), allows attackers to decrypt the config.xml files.
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TP-Link System Inc. | Archer C50 V3 |
Version: 0 |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6982",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-18T14:20:25.297362Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-18T14:20:32.075Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T20:07:18.484Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.kb.cert.org/vuls/id/554637"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Archer C50 V3",
"vendor": "TP-Link System Inc.",
"versions": [
{
"lessThanOrEqual": "180703",
"status": "affected",
"version": "0",
"versionType": "date"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Archer C50 V4",
"vendor": "TP-Link System Inc.",
"versions": [
{
"lessThanOrEqual": "250117",
"status": "affected",
"version": "0",
"versionType": "date"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Archer C50 V5",
"vendor": "TP-Link System Inc.",
"versions": [
{
"lessThanOrEqual": "200407",
"status": "affected",
"version": "0",
"versionType": "date"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Jai Bhortake (Organization: CoE - CNDS Lab, VJTI, Mumbai, India)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Use of Hard-coded Credentials in TP-Link Archer C50 V3(\n\n\u003cb\u003e\u0026lt;=\u003c/b\u003e\n\n180703)/V4(\n\n\n\n\u003cb\u003e\u0026lt;=\u003c/b\u003e\n\n250117\n\n)/V5(\n\n\n\n\u003cb\u003e\u0026lt;=\u003c/b\u003e\n\n200407\n\n),\u0026nbsp;\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eallows attackers to decrypt the config.xml files.\u0026nbsp;\u003c/span\u003e"
}
],
"value": "Use of Hard-coded Credentials in TP-Link Archer C50 V3(\n\n\u003c=\n\n180703)/V4(\n\n\n\n\u003c=\n\n250117\n\n)/V5(\n\n\n\n\u003c=\n\n200407\n\n),\u00a0allows attackers to decrypt the config.xml files."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-17T18:43:37.642Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"url": "https://www.tp-link.com/us/support/faq/4538/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"tags": [
"unsupported-when-assigned"
],
"title": "Hardcoded DES Decryption Keys in TP-Link Archer C50 V3/V4/V5",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-6982",
"datePublished": "2025-07-16T20:01:41.382Z",
"dateReserved": "2025-07-01T20:09:03.975Z",
"dateUpdated": "2025-11-03T20:07:18.484Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}