Vulnerability from variot

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/openSchedWifi schedStartTime and schedEndTime parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202005-0455",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.06.42_multi"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v1.0 15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318_)_cn"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v1.0 15.03.05.19_multi_td01"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v1.0 15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v3.0 15.03.06.42_multi"
      },
      {
        "model": "ac6 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0v15.03.05.19(6318)"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      },
      {
        "model": "ac15 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19(6318)"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac6_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      }
    ]
  },
  "cve": "CVE-2020-13389",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-13389",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.1,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005757",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-31386",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-13389",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005757",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-13389",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-005757",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-31386",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202005-1139",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-13389",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13389"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/openSchedWifi schedStartTime and schedEndTime parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-13389"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13389"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-13389",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1139",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13389",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13389"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "id": "VAR-202005-0455",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      }
    ],
    "trust": 1.3076761016666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:48:00.116000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13389-tenda-vulnerability/"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13389"
      },
      {
        "trust": 1.7,
        "url": "https://joel-malwarebenchmark.github.io"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13389"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/120.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13389"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13389"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-13389"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      },
      {
        "date": "2020-05-22T17:15:11.033000",
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "date": "2020-05-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-13389"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "date": "2020-05-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      },
      {
        "date": "2024-11-21T05:01:09.660000",
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Classic buffer overflow vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      }
    ],
    "trust": 0.6
  }
}

var-202403-0755
Vulnerability from variot

A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda AC18 is a router made by the Chinese company Tenda. This vulnerability is caused by the failure of the wpapsk_crypto5g parameter of the fromSetWirelessRepeat function to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0755",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "15.13.07.09"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14309"
      }
    ]
  },
  "cve": "CVE-2024-2546",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2024-2546",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2024-14309",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2024-2546",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-2546",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-14309",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14309"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2546"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda AC18 is a router made by the Chinese company Tenda. This vulnerability is caused by the failure of the wpapsk_crypto5g parameter of the fromSetWirelessRepeat function to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-2546"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14309"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-2546",
        "trust": 1.6
      },
      {
        "db": "VULDB",
        "id": "256999",
        "trust": 1.0
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14309",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14309"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2546"
      }
    ]
  },
  "id": "VAR-202403-0755",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14309"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14309"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:15:31.733000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC18 fromSetWirelessRepeat function buffer overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/534896"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14309"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-2546"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.0,
        "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/a18/fromsetwirelessrepeat_a.md"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.256999"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?id.256999"
      },
      {
        "trust": 0.6,
        "url": "https://github.com/rnmods/react-native-document-picker/blob/0be5a70c3b456e35c2454aaf4dc8c2d40eb2ab47/android/src/main/java/com/reactnativedocumentpicker/rndocumentpickermodule.java"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14309"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2546"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14309"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2546"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14309"
      },
      {
        "date": "2024-03-17T02:15:06.190000",
        "db": "NVD",
        "id": "CVE-2024-2546"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14309"
      },
      {
        "date": "2024-05-17T02:38:18.283000",
        "db": "NVD",
        "id": "CVE-2024-2546"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 fromSetWirelessRepeat function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14309"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0276
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'startIp' and 'endIp' parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0276",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      }
    ]
  },
  "cve": "CVE-2018-18730",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18730",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-01885",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129319",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18730",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18730",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18730",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-01885",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1357",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129319",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18730"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129319"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18730",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129319",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "id": "VAR-201810-0276",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129319"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:17:17.746000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/stack3.md"
      },
      {
        "trust": 1.4,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18730"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18730"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129319"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      },
      {
        "date": "2018-10-29T12:29:07.727000",
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129319"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "date": "2018-10-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      },
      {
        "date": "2024-11-21T03:56:28.363000",
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      }
    ],
    "trust": 0.6
  }
}

var-202205-1986
Vulnerability from variot

Tenda AC Series Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function form_fast_setting_wifi_set

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202205-1986",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30473"
      }
    ]
  },
  "cve": "CVE-2022-30473",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-30473",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.1,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-30473",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-30473",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202205-4197",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-30473",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30473"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4197"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30473"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC Series Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function form_fast_setting_wifi_set",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30473"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-30473"
      }
    ],
    "trust": 0.99
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-30473",
        "trust": 1.7
      },
      {
        "db": "CS-HELP",
        "id": "SB2022052708",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4197",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-30473",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30473"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4197"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30473"
      }
    ]
  },
  "id": "VAR-202205-1986",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-11-23T22:10:45.281000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/lcyfrank/VulnRepo "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30473"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30473"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://github.com/lcyfrank/vulnrepo/tree/master/iot/tenda/2"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2022052708"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-30473/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/lcyfrank/vulnrepo"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30473"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4197"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30473"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30473"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4197"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30473"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-26T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-30473"
      },
      {
        "date": "2022-05-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-4197"
      },
      {
        "date": "2022-05-26T16:15:08.490000",
        "db": "NVD",
        "id": "CVE-2022-30473"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-06-03T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-30473"
      },
      {
        "date": "2022-06-06T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-4197"
      },
      {
        "date": "2024-11-21T07:02:48.603000",
        "db": "NVD",
        "id": "CVE-2022-30473"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4197"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC Series Router Buffer error vulnerability",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4197"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4197"
      }
    ],
    "trust": 0.6
  }
}

var-202205-1982
Vulnerability from variot

Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetFirewallCfg request

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202205-1982",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30476"
      }
    ]
  },
  "cve": "CVE-2022-30476",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-30476",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.1,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-30476",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-30476",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202205-4193",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-30476",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30476"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4193"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30476"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetFirewallCfg request",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30476"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-30476"
      }
    ],
    "trust": 0.99
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-30476",
        "trust": 1.7
      },
      {
        "db": "CS-HELP",
        "id": "SB2022052708",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4193",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-30476",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30476"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4193"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30476"
      }
    ]
  },
  "id": "VAR-202205-1982",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-11-23T22:10:45.227000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/lcyfrank/VulnRepo "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30476"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30476"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://github.com/lcyfrank/vulnrepo/tree/master/iot/tenda/6"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2022052708"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-30476/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/lcyfrank/vulnrepo"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30476"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4193"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30476"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30476"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4193"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30476"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-26T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-30476"
      },
      {
        "date": "2022-05-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-4193"
      },
      {
        "date": "2022-05-26T16:15:08.630000",
        "db": "NVD",
        "id": "CVE-2022-30476"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-06-03T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-30476"
      },
      {
        "date": "2022-06-06T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-4193"
      },
      {
        "date": "2024-11-21T07:02:49.040000",
        "db": "NVD",
        "id": "CVE-2022-30476"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4193"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC Series Router Buffer error vulnerability",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4193"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4193"
      }
    ],
    "trust": 0.6
  }
}

var-202211-1417
Vulnerability from variot

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function R7WebsSecurityHandler.

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1417",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44172"
      }
    ]
  },
  "cve": "CVE-2022-44172",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-44172",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-44172",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-3234",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3234"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44172"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function R7WebsSecurityHandler.",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44172"
      }
    ],
    "trust": 1.0
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-44172",
        "trust": 1.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3234",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3234"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44172"
      }
    ]
  },
  "id": "VAR-202211-1417",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T14:02:13.584000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44172"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/robinwang825/iot_vuln/blob/main/tenda/ac18/r7webssecurityhandler/tenda_ac18_v15.03.05.19_vuln_password.md"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-44172/"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3234"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44172"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3234"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44172"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3234"
      },
      {
        "date": "2022-11-21T18:15:22.417000",
        "db": "NVD",
        "id": "CVE-2022-44172"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3234"
      },
      {
        "date": "2022-11-28T13:44:25.357000",
        "db": "NVD",
        "id": "CVE-2022-44172"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3234"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 Security hole",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3234"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3234"
      }
    ],
    "trust": 0.6
  }
}

var-202209-1000
Vulnerability from variot

Tenda AC15 WiFi Router V15.03.05.19_multi and AC18 WiFi Router V15.03.05.19_multi were discovered to contain a buffer overflow via the page parameter at /goform/NatStaticSetting. Tenda of AC15 firmware and AC18 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202209-1000",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19_multi"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19_multi"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017011"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38326"
      }
    ]
  },
  "cve": "CVE-2022-38326",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-38326",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-38326",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-38326",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-38326",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202209-1158",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017011"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1158"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38326"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC15 WiFi Router V15.03.05.19_multi and AC18 WiFi Router V15.03.05.19_multi were discovered to contain a buffer overflow via the page parameter at /goform/NatStaticSetting. Tenda of AC15 firmware and AC18 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-38326"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017011"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-38326",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017011",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1158",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017011"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1158"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38326"
      }
    ]
  },
  "id": "VAR-202209-1000",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.401633365
  },
  "last_update_date": "2024-08-14T13:42:26.435000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Tenda AC15 Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=208307"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1158"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017011"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38326"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/1160300418/vuls/blob/main/tenda/ac/vul_natstaticsetting.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-38326"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-38326/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017011"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1158"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38326"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017011"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1158"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38326"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017011"
      },
      {
        "date": "2022-09-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-1158"
      },
      {
        "date": "2022-09-15T20:15:09.583000",
        "db": "NVD",
        "id": "CVE-2022-38326"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-10T08:20:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017011"
      },
      {
        "date": "2022-09-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-1158"
      },
      {
        "date": "2022-09-19T17:58:15.140000",
        "db": "NVD",
        "id": "CVE-2022-38326"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1158"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC15\u00a0 firmware and \u00a0AC18\u00a0 Classic buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017011"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1158"
      }
    ],
    "trust": 0.6
  }
}

var-202311-1968
Vulnerability from variot

Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202311-1968",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac19",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  },
  "cve": "CVE-2023-38823",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-38823",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-38823",
            "trust": 1.0,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-38823"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-38823"
      }
    ],
    "trust": 0.99
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-38823",
        "trust": 1.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-38823",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-38823"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  },
  "id": "VAR-202311-1968",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.41984727499999996
  },
  "last_update_date": "2024-08-14T15:36:40.786000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.0,
        "url": "https://github.com/johnathanhuutri/cve_report/blob/master/cve-2023-38823/readme.md"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/nhtri2003gmail/cve_report/blob/master/cve-2023-38823.md"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-38823"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2023-38823"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-20T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-38823"
      },
      {
        "date": "2023-11-20T20:15:07.357000",
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-21T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-38823"
      },
      {
        "date": "2024-07-29T22:15:03.200000",
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  }
}

var-202402-1997
Vulnerability from variot

An issue was discovered in gui/util/qktxhandler.cpp in Qt before 5.15.17, 6.x before 6.2.12, 6.3.x through 6.5.x before 6.5.5, and 6.6.x before 6.6.2. A buffer overflow and application crash can occur via a crafted KTX image file. Tenda AC18 is a router made by the Chinese company Tenda.

There is a buffer overflow vulnerability in Tenda AC18 V15.03.05.05. The vulnerability is caused by the cmdinput parameter of the formexeCommand function in the /goform/execCommand file failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute on the system. Arbitrary code or lead to denial of service attacks. DescriptionA flaw was found in Qt Base. This flaw allows an malicious user to use a specially crafted KTX image file to trigger a buffer overflow in the application reading it, leading to a denial of service.A flaw was found in Qt Base

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202402-1997",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "15.03.05.05"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ]
  },
  "cve": "CVE-2024-25580",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2024-14308",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "HIGH",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.5,
            "id": "CVE-2024-25580",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2024-25580",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-14308",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered in gui/util/qktxhandler.cpp in Qt before 5.15.17, 6.x before 6.2.12, 6.3.x through 6.5.x before 6.5.5, and 6.6.x before 6.6.2. A buffer overflow and application crash can occur via a crafted KTX image file. Tenda AC18 is a router made by the Chinese company Tenda. \n\r\n\r\nThere is a buffer overflow vulnerability in Tenda AC18 V15.03.05.05. The vulnerability is caused by the cmdinput parameter of the formexeCommand function in the /goform/execCommand file failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute on the system. Arbitrary code or lead to denial of service attacks. Description\u003c!----\u003eA flaw was found in Qt Base. This flaw allows an malicious user to use a specially crafted KTX image file to trigger a buffer overflow in the application reading it, leading to a denial of service.A flaw was found in Qt Base",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580"
      }
    ],
    "trust": 1.53
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-25580",
        "trust": 1.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "id": "VAR-202402-1997",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ]
  },
  "last_update_date": "2024-10-30T23:19:58.117000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC18 formexeCommand function buffer overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/534891"
      },
      {
        "title": "Debian CVElist Bug Report Logs: qt6-base: CVE-2024-25580",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=debian_cvelist_bugreportlogs\u0026qid=2ebf1524fcece0a7b0c6937e8d2445fe"
      },
      {
        "title": "Red Hat: ",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=red_hat_cve_database\u0026qid=CVE-2024-25580"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.0,
        "url": "https://www.qt.io/blog/security-advisory-potential-buffer-overflow-when-reading-ktx-images"
      },
      {
        "trust": 0.7,
        "url": "https://access.redhat.com/security/cve/cve-2024-25580"
      },
      {
        "trust": 0.1,
        "url": "https://bugs.debian.org/cgi-bin/bugreport.cgi?bug=1064052"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "date": "2024-03-27T03:15:12.007000",
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "date": "2024-10-29T20:35:17.633000",
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 formexeCommand function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ],
    "trust": 0.6
  }
}

var-201807-1285
Vulnerability from variot

Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI. Tenda AC7 , AC9 ,and AC10 Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7, AC9 and AC10 are all wireless router products from Tenda. A buffer overflow vulnerability exists in TendaAC715.03.06.44_CN and previous versions, AC915.03.05.19 (6318)_CN and previous versions, and AC1015.03.06.23_CN and earlier. An attacker could exploit the vulnerability with a longer \342\200\230limitSpeed\342\200\231 or \342\200\230limitSpeedup\342\200\231 parameter to cause a denial of service

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201807-1285",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac7",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac10",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac9",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac15",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac10",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 \u003c=15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 \u003c=15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 \u003c=15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tendacn",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tendacn",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tendacn",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tendacn",
        "version": "15.03.05.19_cn"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tendacn:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      }
    ]
  },
  "cve": "CVE-2018-14492",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-14492",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-14983",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-124657",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-14492",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-14492",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-14492",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-14983",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201807-1668",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-124657",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124657"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI. Tenda AC7 , AC9 ,and AC10 Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7, AC9 and AC10 are all wireless router products from Tenda. A buffer overflow vulnerability exists in TendaAC715.03.06.44_CN and previous versions, AC915.03.05.19 (6318)_CN and previous versions, and AC1015.03.06.23_CN and earlier. An attacker could exploit the vulnerability with a longer \\342\\200\\230limitSpeed\\342\\200\\231 or \\342\\200\\230limitSpeedup\\342\\200\\231 parameter to cause a denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-14492"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124657"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-14492",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-124657",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124657"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "id": "VAR-201807-1285",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124657"
      }
    ],
    "trust": 1.3446503185714285
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:52:01.968000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-119",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-124657"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://github.com/zillr0/routers/blob/master/tendaoob1.md"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14492"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14492"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124657"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124657"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-08-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "date": "2018-07-21T00:00:00",
        "db": "VULHUB",
        "id": "VHN-124657"
      },
      {
        "date": "2018-10-18T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "date": "2018-07-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      },
      {
        "date": "2018-07-21T12:29:00.333000",
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-08-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-124657"
      },
      {
        "date": "2018-10-18T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "date": "2020-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      },
      {
        "date": "2024-11-21T03:49:10.740000",
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0273
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceList' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (covering the return value of a function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0273",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac10",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      }
    ]
  },
  "cve": "CVE-2018-18727",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18727",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-01888",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129315",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18727",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18727",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18727",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-01888",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1354",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129315",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129315"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (covering the return value of a function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18727"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129315"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18727",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129315",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129315"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "id": "VAR-201810-0273",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129315"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:45:10.729000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129315"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/stack1.md"
      },
      {
        "trust": 1.4,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18727"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18727"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129315"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129315"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129315"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      },
      {
        "date": "2018-10-29T12:29:07.400000",
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129315"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "date": "2018-10-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      },
      {
        "date": "2024-11-21T03:56:27.863000",
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      }
    ],
    "trust": 0.6
  }
}

var-202211-1418
Vulnerability from variot

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetWifiGuestBasic. Tenda AC18 is a router made by Chinese company Tenda. The vulnerability is caused by the fact that the formSetWifiGuestBasic function does not check the length of the input data. Attackers can exploit the vulnerability to cause denial of service

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1418",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87027"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44183"
      }
    ]
  },
  "cve": "CVE-2022-44183",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-87027",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-44183",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-44183",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-87027",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-3228",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87027"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3228"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44183"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetWifiGuestBasic. Tenda AC18 is a router made by Chinese company Tenda. The vulnerability is caused by the fact that the formSetWifiGuestBasic function does not check the length of the input data. Attackers can exploit the vulnerability to cause denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44183"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-87027"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-44183",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-87027",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3228",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87027"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3228"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44183"
      }
    ]
  },
  "id": "VAR-202211-1418",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87027"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87027"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:00:42.280000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44183"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://github.com/robinwang825/iot_vuln/tree/main/tenda/ac18/formsetwifiguestbasic"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-44183/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87027"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3228"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44183"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87027"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3228"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44183"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-87027"
      },
      {
        "date": "2022-11-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3228"
      },
      {
        "date": "2022-11-21T18:15:24.947000",
        "db": "NVD",
        "id": "CVE-2022-44183"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-87027"
      },
      {
        "date": "2022-11-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3228"
      },
      {
        "date": "2022-11-28T13:32:04.637000",
        "db": "NVD",
        "id": "CVE-2022-44183"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3228"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 formSetWifiGuestBasic function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87027"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3228"
      }
    ],
    "trust": 0.6
  }
}

var-202209-0311
Vulnerability from variot

Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/PowerSaveSet. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202209-0311",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.19(6318)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016270"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38311"
      }
    ]
  },
  "cve": "CVE-2022-38311",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-38311",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-38311",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-38311",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-38311",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202209-445",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016270"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-445"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38311"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/PowerSaveSet. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-38311"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016270"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-38311",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016270",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-445",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016270"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-445"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38311"
      }
    ]
  },
  "id": "VAR-202209-0311",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T15:27:06.632000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016270"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38311"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/rickytriky/nwpu_projct/tree/main/tenda/ac18/5"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-38311"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-38311/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016270"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-445"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38311"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016270"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-445"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38311"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-03T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016270"
      },
      {
        "date": "2022-09-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-445"
      },
      {
        "date": "2022-09-07T19:15:08.783000",
        "db": "NVD",
        "id": "CVE-2022-38311"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-03T08:07:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016270"
      },
      {
        "date": "2022-09-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-445"
      },
      {
        "date": "2022-09-10T03:23:02.127000",
        "db": "NVD",
        "id": "CVE-2022-38311"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-445"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016270"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-445"
      }
    ],
    "trust": 0.6
  }
}

var-202209-0324
Vulnerability from variot

Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetIpMacBind. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202209-0324",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.19(6318)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016269"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38312"
      }
    ]
  },
  "cve": "CVE-2022-38312",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-38312",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-38312",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-38312",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-38312",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202209-444",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016269"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-444"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38312"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetIpMacBind. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-38312"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016269"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-38312",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016269",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-444",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016269"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-444"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38312"
      }
    ]
  },
  "id": "VAR-202209-0324",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T15:16:30.382000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016269"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38312"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/rickytriky/nwpu_projct/tree/main/tenda/ac18/3"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-38312"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-38312/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016269"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-444"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38312"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016269"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-444"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38312"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-03T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016269"
      },
      {
        "date": "2022-09-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-444"
      },
      {
        "date": "2022-09-07T19:15:08.830000",
        "db": "NVD",
        "id": "CVE-2022-38312"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-03T08:07:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016269"
      },
      {
        "date": "2022-09-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-444"
      },
      {
        "date": "2022-09-10T03:23:20.540000",
        "db": "NVD",
        "id": "CVE-2022-38312"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-444"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016269"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-444"
      }
    ],
    "trust": 0.6
  }
}

var-202209-1328
Vulnerability from variot

Tenda AC15 WiFi Router V15.03.05.19_multi and AC18 WiFi Router V15.03.05.19_multi were discovered to contain a buffer overflow via the filePath parameter at /goform/expandDlnaFile. Tenda of AC15 firmware and AC18 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202209-1328",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19_multi"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19_multi"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017012"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38325"
      }
    ]
  },
  "cve": "CVE-2022-38325",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-38325",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-38325",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-38325",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-38325",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202209-1161",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017012"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1161"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38325"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC15 WiFi Router V15.03.05.19_multi and AC18 WiFi Router V15.03.05.19_multi were discovered to contain a buffer overflow via the filePath parameter at /goform/expandDlnaFile. Tenda of AC15 firmware and AC18 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-38325"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017012"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-38325",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017012",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1161",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017012"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1161"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38325"
      }
    ]
  },
  "id": "VAR-202209-1328",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.401633365
  },
  "last_update_date": "2024-08-14T15:11:15.985000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Tenda AC15 Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=208308"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1161"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017012"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38325"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/1160300418/vuls/blob/main/tenda/ac/vul_expanddlnafile.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-38325"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-38325/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017012"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1161"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38325"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017012"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1161"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38325"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017012"
      },
      {
        "date": "2022-09-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-1161"
      },
      {
        "date": "2022-09-15T20:15:09.537000",
        "db": "NVD",
        "id": "CVE-2022-38325"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-10T08:20:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017012"
      },
      {
        "date": "2022-09-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-1161"
      },
      {
        "date": "2022-09-19T17:59:04.363000",
        "db": "NVD",
        "id": "CVE-2022-38325"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1161"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC15\u00a0 firmware and \u00a0AC18\u00a0 Classic buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017012"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-1161"
      }
    ],
    "trust": 0.6
  }
}

var-202209-1754
Vulnerability from variot

Tenda AC15 and AC18 routers V15.03.05.19 contain heap overflow vulnerabilities in the function setSchedWifi with the request /goform/openSchedWifi/. Tenda of AC15 firmware and AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Both the Tenda AC15 and Tenda AC18 are products of the Chinese company Tenda. Tenda AC15 is a wireless router. Tenda AC18 is a router. The vulnerability stems from the fact that the setSchedWifi method does not check the size of the input data when there is a request /goform/openSchedWifi/. Attackers can exploit the vulnerability to cause remote code execution or rejection Serve

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202209-1754",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88196"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017554"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40865"
      }
    ]
  },
  "cve": "CVE-2022-40865",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-88196",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-40865",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-40865",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-40865",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-40865",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-88196",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202209-2389",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88196"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017554"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2389"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40865"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC15 and AC18 routers V15.03.05.19 contain heap overflow vulnerabilities in the function setSchedWifi with the request /goform/openSchedWifi/. Tenda of AC15 firmware and AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Both the Tenda AC15 and Tenda AC18 are products of the Chinese company Tenda. Tenda AC15 is a wireless router. Tenda AC18 is a router. The vulnerability stems from the fact that the setSchedWifi method does not check the size of the input data when there is a request /goform/openSchedWifi/. Attackers can exploit the vulnerability to cause remote code execution or rejection Serve",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-40865"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017554"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-88196"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-40865",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017554",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-88196",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2389",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88196"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017554"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2389"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40865"
      }
    ]
  },
  "id": "VAR-202209-1754",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88196"
      }
    ],
    "trust": 1.001633365
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88196"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:16:29.066000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC15 and AC18 setSchedWifi heap overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/372506"
      },
      {
        "title": "Tenda AC15 Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=208892"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88196"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2389"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017554"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40865"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.0,
        "url": "https://github.com/cpseek/router-vuls/blob/main/tenda/ac15/setschedwifi.md"
      },
      {
        "trust": 2.4,
        "url": "https://github.com/cpseek/router-vuls/blob/main/tenda/ac18/setschedwifi.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-40865"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-40865/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88196"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017554"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2389"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40865"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88196"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017554"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2389"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40865"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-88196"
      },
      {
        "date": "2023-10-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017554"
      },
      {
        "date": "2022-09-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-2389"
      },
      {
        "date": "2022-09-23T14:15:13.347000",
        "db": "NVD",
        "id": "CVE-2022-40865"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-88196"
      },
      {
        "date": "2023-10-13T08:42:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017554"
      },
      {
        "date": "2022-09-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-2389"
      },
      {
        "date": "2022-09-23T20:22:48.883000",
        "db": "NVD",
        "id": "CVE-2022-40865"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2389"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC15\u00a0 firmware and \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017554"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2389"
      }
    ],
    "trust": 0.6
  }
}

var-202305-0317
Vulnerability from variot

Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName parameter in the setUsbUnload function

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202305-0317",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-30135"
      }
    ]
  },
  "cve": "CVE-2023-30135",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-30135",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-30135",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202305-289",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-289"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-30135"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName parameter in the setUsbUnload function",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-30135"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-30135"
      }
    ],
    "trust": 0.99
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-30135",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-289",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-30135",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-30135"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-289"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-30135"
      }
    ]
  },
  "id": "VAR-202305-0317",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T14:36:53.206000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-77",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-30135"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://github.com/drizzlingsun/tenda/blob/main/ac18/8/8.md"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-30135/"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-30135"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-289"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-30135"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2023-30135"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-289"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-30135"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-05-05T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-30135"
      },
      {
        "date": "2023-05-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202305-289"
      },
      {
        "date": "2023-05-05T02:15:08.813000",
        "db": "NVD",
        "id": "CVE-2023-30135"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-05-05T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-30135"
      },
      {
        "date": "2023-05-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202305-289"
      },
      {
        "date": "2023-05-11T14:31:18.483000",
        "db": "NVD",
        "id": "CVE-2023-30135"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-289"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 Command injection vulnerability",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-289"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-289"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0275
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router's web server -- httpd. While processing the 'mac' parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow. plural Tenda The product contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0275",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      }
    ]
  },
  "cve": "CVE-2018-18729",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18729",
            "impactScore": 8.5,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-01886",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-129317",
            "impactScore": 8.5,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18729",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18729",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18729",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-01886",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1356",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129317",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129317"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow. plural Tenda The product contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18729"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129317"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18729",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129317",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129317"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "id": "VAR-201810-0275",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129317"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:58:50.557000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-119",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129317"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/heapoverflow1.md"
      },
      {
        "trust": 1.4,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18729"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18729"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129317"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129317"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129317"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      },
      {
        "date": "2018-10-29T12:29:07.617000",
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129317"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      },
      {
        "date": "2024-11-21T03:56:28.197000",
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      }
    ],
    "trust": 0.6
  }
}

var-202407-0778
Vulnerability from variot

Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/addWifiMacFilter. Tenda of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202407-0778",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.3.10"
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.3.10"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004511"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-33182"
      }
    ]
  },
  "cve": "CVE-2024-33182",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2024-33182",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "LOW",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2024-33182",
            "impactScore": 5.5,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-33182",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-33182",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2024-33182",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2024-33182",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004511"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-33182"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-33182"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/addWifiMacFilter. Tenda of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-33182"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004511"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-33182",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004511",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004511"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-33182"
      }
    ]
  },
  "id": "VAR-202407-0778",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T14:16:28.083000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004511"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-33182"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://palm-vertebra-fe9.notion.site/addwifimacfilter_1-067fa6984f0d4933b88c63efd7486479"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-33182"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004511"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-33182"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004511"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-33182"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-07-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-004511"
      },
      {
        "date": "2024-07-16T16:15:04.850000",
        "db": "NVD",
        "id": "CVE-2024-33182"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-07-22T05:25:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-004511"
      },
      {
        "date": "2024-08-01T13:51:45.673000",
        "db": "NVD",
        "id": "CVE-2024-33182"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004511"
      }
    ],
    "trust": 0.8
  }
}

var-202211-1487
Vulnerability from variot

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetMacFilterCfg.

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1487",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44175"
      }
    ]
  },
  "cve": "CVE-2022-44175",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-44175",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-44175",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-3232",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3232"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44175"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetMacFilterCfg.",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44175"
      }
    ],
    "trust": 1.0
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-44175",
        "trust": 1.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3232",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3232"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44175"
      }
    ]
  },
  "id": "VAR-202211-1487",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T14:30:51.470000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44175"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/robinwang825/iot_vuln/blob/main/tenda/ac18/formsetmacfiltercfg/readme.md"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-44175/"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3232"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44175"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3232"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44175"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3232"
      },
      {
        "date": "2022-11-21T18:15:22.897000",
        "db": "NVD",
        "id": "CVE-2022-44175"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3232"
      },
      {
        "date": "2022-11-28T13:47:12.870000",
        "db": "NVD",
        "id": "CVE-2022-44175"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3232"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 Security hole",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3232"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3232"
      }
    ],
    "trust": 0.6
  }
}

var-202005-0460
Vulnerability from variot

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/SetNetControlList list parameter for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202005-0460",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.06.42_multi"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0v15.03.05.19(6318)"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      },
      {
        "model": "ac15 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19(6318)"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac6_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      }
    ]
  },
  "cve": "CVE-2020-13394",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-13394",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005748",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-31409",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-13394",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005748",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-13394",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-005748",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-31409",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202005-1144",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/SetNetControlList list parameter for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-13394"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-13394",
        "trust": 3.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1144",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "id": "VAR-202005-0460",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      }
    ],
    "trust": 1.3076761016666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:58:17.264000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://tendacn.com/en"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13394-tenda-vulnerability/"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13394"
      },
      {
        "trust": 1.6,
        "url": "https://joel-malwarebenchmark.github.io"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13394"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      },
      {
        "date": "2020-05-22T17:15:11.363000",
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "date": "2020-05-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      },
      {
        "date": "2024-11-21T05:01:10.413000",
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Classic buffer overflow vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      }
    ],
    "trust": 0.6
  }
}

var-202211-1362
Vulnerability from variot

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formWifiWpsStart. Tenda AC18 is a router made by Chinese company Tenda. The vulnerability is caused by the fact that the formWifiWpsStart function does not check the length of the input data. Attackers can exploit the vulnerability to cause denial of service

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1362",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87029"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44177"
      }
    ]
  },
  "cve": "CVE-2022-44177",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-87029",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-44177",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-44177",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-87029",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-3229",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87029"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3229"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44177"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formWifiWpsStart. Tenda AC18 is a router made by Chinese company Tenda. The vulnerability is caused by the fact that the formWifiWpsStart function does not check the length of the input data. Attackers can exploit the vulnerability to cause denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44177"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-87029"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-44177",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-87029",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3229",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87029"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3229"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44177"
      }
    ]
  },
  "id": "VAR-202211-1362",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87029"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87029"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:55:08.348000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44177"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://github.com/robinwang825/iot_vuln/tree/main/tenda/ac18/formwifiwpsstart"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-44177/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87029"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3229"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44177"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87029"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3229"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44177"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-87029"
      },
      {
        "date": "2022-11-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3229"
      },
      {
        "date": "2022-11-21T18:15:23.587000",
        "db": "NVD",
        "id": "CVE-2022-44177"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-87029"
      },
      {
        "date": "2022-11-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3229"
      },
      {
        "date": "2022-11-28T13:48:36.607000",
        "db": "NVD",
        "id": "CVE-2022-44177"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3229"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 formWifiWpsStart function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87029"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3229"
      }
    ],
    "trust": 0.6
  }
}

var-202209-0325
Vulnerability from variot

Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/saveParentControlInfo. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202209-0325",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.19(6318)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016268"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38313"
      }
    ]
  },
  "cve": "CVE-2022-38313",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-38313",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-38313",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-38313",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-38313",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202209-443",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016268"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-443"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38313"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/saveParentControlInfo. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-38313"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016268"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-38313",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016268",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-443",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016268"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-443"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38313"
      }
    ]
  },
  "id": "VAR-202209-0325",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T15:00:47.183000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016268"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38313"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/rickytriky/nwpu_projct/tree/main/tenda/ac18/2"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-38313"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-38313/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016268"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-443"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38313"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016268"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-443"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38313"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-03T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016268"
      },
      {
        "date": "2022-09-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-443"
      },
      {
        "date": "2022-09-07T19:15:08.870000",
        "db": "NVD",
        "id": "CVE-2022-38313"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-03T08:07:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016268"
      },
      {
        "date": "2022-09-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-443"
      },
      {
        "date": "2022-09-10T03:23:30.860000",
        "db": "NVD",
        "id": "CVE-2022-38313"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-443"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016268"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-443"
      }
    ],
    "trust": 0.6
  }
}

var-201711-0574
Vulnerability from variot

Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318)cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1&path= URI that uses directory traversal sequences after a /usb/ substring. Shenzhen Tenda Ac9 , Ac15 ,and Ac18 The device contains a path traversal vulnerability.Information may be obtained. ShenzhenTendaAc9 and other are the wireless router products of Tenda. App_data_center is one of the application data centers. A directory traversal vulnerability exists in app_data_center in several ShenzhenTenda products. A remote attacker can exploit this vulnerability to read arbitrary files. The following products and versions are affected: Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01 Version, Ac9 ac9_kf_V15.03.05.19(6318)cn Version, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01 Version, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01 Version , Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01 version, Ac18 ac18_kf_V15.03.05.19(6318)_cn version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201711-0574",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac15v1.0br_v15.03.05.18_multi_td01"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac15v1.0br_v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac18v1.0br_v15.03.05.05_multi_td01"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac9v1.0br_v15.03.05.14_multi_td01"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "ac9_kf_v15.03.05.19\\(6318_\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "ac18_kf_v15.03.05.19\\(6318_\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18_kf_v15.03.05.19(6318_)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9_kf_v15.03.05.19(6318_)_cn"
      },
      {
        "model": "tenda technology co.,ltd. ac9 us_ac9v1.0br_v15.03.05.14_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac9 ac9_kf_v15.03.05.19 _cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac15 us_ac15v1.0br_v15.03.05.18_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac15 us_ac15v1.0br_v15.03.05.19_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac18 us_ac18v1.0br_v15.03.05.05_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac18 ac18 ac18_kf_v15.03.05.19 _cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      }
    ]
  },
  "cve": "CVE-2017-16936",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "CVE-2017-16936",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 1.8,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2017-35381",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "VHN-107908",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.1,
            "vectorString": "AV:A/AC:L/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2017-16936",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-16936",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-16936",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-35381",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201711-1055",
            "trust": 0.6,
            "value": "LOW"
          },
          {
            "author": "VULHUB",
            "id": "VHN-107908",
            "trust": 0.1,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107908"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1\u0026path= URI that uses directory traversal sequences after a /usb/ substring. Shenzhen Tenda Ac9 , Ac15 ,and Ac18 The device contains a path traversal vulnerability.Information may be obtained. ShenzhenTendaAc9 and other are the wireless router products of Tenda. App_data_center is one of the application data centers. A directory traversal vulnerability exists in app_data_center in several ShenzhenTenda products. A remote attacker can exploit this vulnerability to read arbitrary files. The following products and versions are affected: Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01 Version, Ac9 ac9_kf_V15.03.05.19(6318_)_cn Version, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01 Version, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01 Version , Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01 version, Ac18 ac18_kf_V15.03.05.19(6318_)_cn version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-16936"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107908"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-16936",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-107908",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107908"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "id": "VAR-201711-0574",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107908"
      }
    ],
    "trust": 1.1153522033333332
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:12:47.863000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://tendacn.com/en/default.html"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-22",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-107908"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://github.com/iolop/poc/tree/master/router/tenda"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-16936"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-16936"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107908"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107908"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-11-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "date": "2017-11-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-107908"
      },
      {
        "date": "2017-12-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "date": "2017-11-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      },
      {
        "date": "2017-11-24T07:29:00.350000",
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-11-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "date": "2017-12-12T00:00:00",
        "db": "VULHUB",
        "id": "VHN-107908"
      },
      {
        "date": "2017-12-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "date": "2017-11-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      },
      {
        "date": "2024-11-21T03:17:16.710000",
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "specific network environment",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Shenzhen Tenda Path traversal vulnerability in devices",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "path traversal",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      }
    ],
    "trust": 0.6
  }
}

var-202005-0456
Vulnerability from variot

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/addressNat entrys and mitInterface parameters for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202005-0456",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.06.42_multi"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v1.0 15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318_)_cn"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v1.0 15.03.05.19_multi_td01"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v1.0 15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v3.0 15.03.06.42_multi"
      },
      {
        "model": "ac6 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      },
      {
        "model": "ac15 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac18 ) cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19(6318"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac6_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      }
    ]
  },
  "cve": "CVE-2020-13390",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-13390",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005758",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-31387",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-13390",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005758",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-13390",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-005758",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-31387",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202005-1140",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/addressNat entrys and mitInterface parameters for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-13390"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-13390",
        "trust": 3.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1140",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "id": "VAR-202005-0456",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      }
    ],
    "trust": 1.38075707625
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:29:37.793000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13390-tenda-vulnerability/"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13390"
      },
      {
        "trust": 1.6,
        "url": "https://joel-malwarebenchmark.github.io"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13390"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      },
      {
        "date": "2020-05-22T17:15:11.097000",
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "date": "2020-05-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      },
      {
        "date": "2024-11-21T05:01:09.810000",
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Classic buffer overflow vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      }
    ],
    "trust": 0.6
  }
}

var-202205-1984
Vulnerability from variot

Tenda AC Seris Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function fromAddressNat

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202205-1984",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30472"
      }
    ]
  },
  "cve": "CVE-2022-30472",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-30472",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-30472",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-30472",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202205-4196",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4196"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30472"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC Seris Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function fromAddressNat",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30472"
      }
    ],
    "trust": 1.0
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-30472",
        "trust": 1.6
      },
      {
        "db": "CS-HELP",
        "id": "SB2022052708",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4196",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4196"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30472"
      }
    ]
  },
  "id": "VAR-202205-1984",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-11-23T22:10:45.298000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30472"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/lcyfrank/vulnrepo/tree/master/iot/tenda/1"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-30472/"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2022052708"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4196"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30472"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4196"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30472"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-4196"
      },
      {
        "date": "2022-05-26T16:15:08.447000",
        "db": "NVD",
        "id": "CVE-2022-30472"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-06-06T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-4196"
      },
      {
        "date": "2024-11-21T07:02:48.450000",
        "db": "NVD",
        "id": "CVE-2022-30472"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4196"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC Series Router Buffer error vulnerability",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4196"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4196"
      }
    ],
    "trust": 0.6
  }
}

var-202205-1985
Vulnerability from variot

Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a heap overflow in the httpd module when handling /goform/saveParentControlInfo request

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202205-1985",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30474"
      }
    ]
  },
  "cve": "CVE-2022-30474",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-30474",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.1,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-30474",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-30474",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202205-4195",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-30474",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30474"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4195"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30474"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a heap overflow in the httpd module when handling /goform/saveParentControlInfo request",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30474"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-30474"
      }
    ],
    "trust": 0.99
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-30474",
        "trust": 1.7
      },
      {
        "db": "CS-HELP",
        "id": "SB2022052708",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4195",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-30474",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30474"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4195"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30474"
      }
    ]
  },
  "id": "VAR-202205-1985",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-11-23T22:10:45.314000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/lcyfrank/VulnRepo "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30474"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30474"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://github.com/lcyfrank/vulnrepo/tree/master/iot/tenda/5"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2022052708"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-30474/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/lcyfrank/vulnrepo"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30474"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4195"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30474"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30474"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4195"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30474"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-26T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-30474"
      },
      {
        "date": "2022-05-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-4195"
      },
      {
        "date": "2022-05-26T16:15:08.533000",
        "db": "NVD",
        "id": "CVE-2022-30474"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-06-03T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-30474"
      },
      {
        "date": "2022-06-06T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-4195"
      },
      {
        "date": "2024-11-21T07:02:48.753000",
        "db": "NVD",
        "id": "CVE-2022-30474"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4195"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC Series Router Buffer error vulnerability",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4195"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4195"
      }
    ],
    "trust": 0.6
  }
}

var-202209-1836
Vulnerability from variot

Tenda AC18 router V15.03.05.19 contains a stack overflow vulnerability in the formSetQosBand->FUN_0007db78 function with the request /goform/SetNetControlList/. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the fact that the formSetQosBand function does not check the size of the input data. Attackers can exploit the vulnerability to cause remote code execution or denial of service

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202209-1836",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.19(6318)"
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88202"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017715"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40861"
      }
    ]
  },
  "cve": "CVE-2022-40861",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2022-88202",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.2,
            "id": "CVE-2022-40861",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.2,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-40861",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-40861",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-40861",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-88202",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202209-2376",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88202"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017715"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2376"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40861"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 router V15.03.05.19 contains a stack overflow vulnerability in the formSetQosBand-\u003eFUN_0007db78 function with the request /goform/SetNetControlList/. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the fact that the formSetQosBand function does not check the size of the input data. Attackers can exploit the vulnerability to cause remote code execution or denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-40861"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017715"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-88202"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-40861",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017715",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-88202",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2376",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88202"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017715"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2376"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40861"
      }
    ]
  },
  "id": "VAR-202209-1836",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88202"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88202"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:00:45.928000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC18 formSetQosBand stack overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/372606"
      },
      {
        "title": "Tenda AC18 Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209151"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88202"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2376"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017715"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40861"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.0,
        "url": "https://github.com/cpseek/router-vuls/blob/main/tenda/ac18/formsetqosband.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-40861"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-40861/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88202"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017715"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2376"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40861"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88202"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017715"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2376"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40861"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-17T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-88202"
      },
      {
        "date": "2023-10-16T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017715"
      },
      {
        "date": "2022-09-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-2376"
      },
      {
        "date": "2022-09-23T15:15:14.533000",
        "db": "NVD",
        "id": "CVE-2022-40861"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-88202"
      },
      {
        "date": "2023-10-16T08:19:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017715"
      },
      {
        "date": "2022-09-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-2376"
      },
      {
        "date": "2022-09-26T16:03:31.140000",
        "db": "NVD",
        "id": "CVE-2022-40861"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2376"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017715"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2376"
      }
    ],
    "trust": 0.6
  }
}

var-202403-1040
Vulnerability from variot

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202403-1040",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003017"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-28553"
      }
    ]
  },
  "cve": "CVE-2024-28553",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2024-28553",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-28553",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-28553",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2024-28553",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2024-28553",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003017"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-28553"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-28553"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-28553"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003017"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-28553",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003017",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003017"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-28553"
      }
    ]
  },
  "id": "VAR-202403-1040",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-29T23:08:14.454000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003017"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-28553"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac18/fromaddressnat_entrys.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-28553"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003017"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-28553"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003017"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-28553"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-003017"
      },
      {
        "date": "2024-03-12T13:15:49.763000",
        "db": "NVD",
        "id": "CVE-2024-28553"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-25T06:39:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-003017"
      },
      {
        "date": "2024-08-28T18:35:12.120000",
        "db": "NVD",
        "id": "CVE-2024-28553"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003017"
      }
    ],
    "trust": 0.8
  }
}

var-202410-1497
Vulnerability from variot

A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. AC15 firmware, AC7 firmware, ac10u firmware etc. The product has NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202410-1497",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac1206",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.23"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.48.23"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.13"
      },
      {
        "model": "ac500",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.0.0.16"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.10.20"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.42"
      },
      {
        "model": "ac8",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.34.09"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.44"
      },
      {
        "model": "ac500",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.0.0.14"
      },
      {
        "model": "ac500",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "2.0.1.9\\(1307\\)"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.18"
      },
      {
        "model": "ac8",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.34.06"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.48.19"
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.48"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.05"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.10.13"
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.49"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.14"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.23"
      },
      {
        "model": "ac10",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac1206",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac500",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "cve": "CVE-2024-10280",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2024-10280",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Complete",
            "baseScore": 6.8,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-011851",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2024-10280",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2024-10280",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-011851",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-10280",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-10280",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2024-011851",
            "trust": 0.8,
            "value": "High"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. AC15 firmware, AC7 firmware, ac10u firmware etc. The product has NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-10280",
        "trust": 2.6
      },
      {
        "db": "VULDB",
        "id": "281555",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "id": "VAR-202410-1497",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.4059792066666667
  },
  "last_update_date": "2024-11-07T22:35:04.235000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-476",
        "trust": 1.0
      },
      {
        "problemtype": "NULL Pointer dereference (CWE-476) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/johenanli/router_vuls/blob/main/websreadevent/websreadevent.md"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.281555"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.426417"
      },
      {
        "trust": 1.8,
        "url": "https://www.tenda.com.cn/"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.281555"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-10280"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-11-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "date": "2024-10-23T14:15:04.500000",
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-11-05T02:27:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "date": "2024-11-01T14:03:20.267000",
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 In the product \u00a0NULL\u00a0 Pointer dereference vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      }
    ],
    "trust": 0.8
  }
}

var-202301-2301
Vulnerability from variot

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_0007343c. Tenda AC18 is a router of Tenda company. Attackers can use this vulnerability to submit special requests, crash the program or execute arbitrary code in the context

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202301-2301",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21675"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24169"
      }
    ]
  },
  "cve": "CVE-2023-24169",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-21675",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-24169",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-24169",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-21675",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202301-1989",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21675"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1989"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24169"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_0007343c. Tenda AC18 is a router of Tenda company. Attackers can use this vulnerability to submit special requests, crash the program or execute arbitrary code in the context",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-24169"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-21675"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24169"
      }
    ],
    "trust": 1.53
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-24169",
        "trust": 2.3
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-21675",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1989",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24169",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21675"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24169"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1989"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24169"
      }
    ]
  },
  "id": "VAR-202301-2301",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21675"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21675"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:37:10.097000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC18 buffer overflow vulnerability (CNVD-2023-21675)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/416316"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21675"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-24169"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://github.com/drizzlingsun/tenda/blob/main/ac18/6/6.md"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-24169/"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21675"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24169"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1989"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24169"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21675"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24169"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1989"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24169"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-21675"
      },
      {
        "date": "2023-01-26T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-24169"
      },
      {
        "date": "2023-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202301-1989"
      },
      {
        "date": "2023-01-26T21:18:16.507000",
        "db": "NVD",
        "id": "CVE-2023-24169"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-21675"
      },
      {
        "date": "2023-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-24169"
      },
      {
        "date": "2023-02-02T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202301-1989"
      },
      {
        "date": "2023-02-01T20:27:07.287000",
        "db": "NVD",
        "id": "CVE-2023-24169"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1989"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 buffer overflow vulnerability (CNVD-2023-21675)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21675"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1989"
      }
    ],
    "trust": 0.6
  }
}

var-202209-0483
Vulnerability from variot

Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetStaticRouteCfg. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202209-0483",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.19(6318)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016271"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38310"
      }
    ]
  },
  "cve": "CVE-2022-38310",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-38310",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-38310",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-38310",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-38310",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202209-446",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016271"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-446"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38310"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetStaticRouteCfg. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-38310"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016271"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-38310",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016271",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-446",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016271"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-446"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38310"
      }
    ]
  },
  "id": "VAR-202209-0483",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T14:49:38.560000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016271"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38310"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/rickytriky/nwpu_projct/tree/main/tenda/ac18/6"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-38310"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-38310/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016271"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-446"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38310"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016271"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-446"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38310"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-03T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016271"
      },
      {
        "date": "2022-09-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-446"
      },
      {
        "date": "2022-09-07T19:15:08.740000",
        "db": "NVD",
        "id": "CVE-2022-38310"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-03T08:07:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016271"
      },
      {
        "date": "2022-09-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-446"
      },
      {
        "date": "2022-09-10T03:22:40.773000",
        "db": "NVD",
        "id": "CVE-2022-38310"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-446"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016271"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-446"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0243
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0243",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      }
    ]
  },
  "cve": "CVE-2018-18706",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18706",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-09140",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129292",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18706",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18706",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18706",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-09140",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1337",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129292",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129292"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18706"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129292"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18706",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129292",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129292"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "id": "VAR-201810-0243",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129292"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:12:19.756000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129292"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/tenda.md"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18706"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18706"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129292"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129292"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-04-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129292"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      },
      {
        "date": "2018-10-29T12:29:05.400000",
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-04-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129292"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "date": "2018-10-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      },
      {
        "date": "2024-11-21T03:56:24.723000",
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      }
    ],
    "trust": 0.6
  }
}

var-202209-1620
Vulnerability from variot

Tenda AC15 and AC18 router V15.03.05.19 contains stack overflow vulnerability in the function fromNatStaticSetting with the request /goform/NatStaticSetting. Tenda of AC15 firmware and AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Both the Tenda AC15 and Tenda AC18 are products of the Chinese company Tenda. Tenda AC15 is a wireless router. Tenda AC18 is a router. The vulnerability stems from the fact that the fromNatStaticSetting method does not check the size of the input data when it has the request /goform/NatStaticSetting. Attackers can exploit the vulnerability to cause remote code execution or rejection Serve

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202209-1620",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88195"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017556"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40862"
      }
    ]
  },
  "cve": "CVE-2022-40862",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-88195",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-40862",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-40862",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-40862",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-40862",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-88195",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202209-2393",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88195"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017556"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2393"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40862"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC15 and AC18 router V15.03.05.19 contains stack overflow vulnerability in the function fromNatStaticSetting with the request /goform/NatStaticSetting. Tenda of AC15 firmware and AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Both the Tenda AC15 and Tenda AC18 are products of the Chinese company Tenda. Tenda AC15 is a wireless router. Tenda AC18 is a router. The vulnerability stems from the fact that the fromNatStaticSetting method does not check the size of the input data when it has the request /goform/NatStaticSetting. Attackers can exploit the vulnerability to cause remote code execution or rejection Serve",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-40862"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017556"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-88195"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-40862",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017556",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-88195",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2393",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88195"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017556"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2393"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40862"
      }
    ]
  },
  "id": "VAR-202209-1620",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88195"
      }
    ],
    "trust": 1.001633365
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88195"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:24:30.733000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC15 and AC18 fromNatStaticSetting stack overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/372491"
      },
      {
        "title": "Tenda AC15 Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=208895"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88195"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2393"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017556"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40862"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.0,
        "url": "https://github.com/cpseek/router-vuls/blob/main/tenda/ac18/fromnatstaticsetting.md"
      },
      {
        "trust": 2.4,
        "url": "https://github.com/cpseek/router-vuls/blob/main/tenda/ac15/fromnatstaticsetting.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-40862"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-40862/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88195"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017556"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2393"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40862"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88195"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017556"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2393"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40862"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-88195"
      },
      {
        "date": "2023-10-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017556"
      },
      {
        "date": "2022-09-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-2393"
      },
      {
        "date": "2022-09-23T14:15:13.260000",
        "db": "NVD",
        "id": "CVE-2022-40862"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-88195"
      },
      {
        "date": "2023-10-13T08:42:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017556"
      },
      {
        "date": "2022-09-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-2393"
      },
      {
        "date": "2022-09-23T20:27:58.547000",
        "db": "NVD",
        "id": "CVE-2022-40862"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2393"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC15\u00a0 firmware and \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017556"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2393"
      }
    ],
    "trust": 0.6
  }
}

var-202209-1991
Vulnerability from variot

Tenda AC18 router contained a stack overflow vulnerability in /goform/fast_setting_wifi_set. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the fact that the fast_setting_wifi_set function does not check the size of the input data. Attackers can exploit the vulnerability to cause remote code execution or denial of service

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202209-1991",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.19(6318)"
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88201"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017872"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40854"
      }
    ]
  },
  "cve": "CVE-2022-40854",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-88201",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-40854",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-40854",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-40854",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-40854",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-88201",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202209-2373",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88201"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017872"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2373"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40854"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 router contained a stack overflow vulnerability in /goform/fast_setting_wifi_set. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the fact that the fast_setting_wifi_set function does not check the size of the input data. Attackers can exploit the vulnerability to cause remote code execution or denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-40854"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017872"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-88201"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-40854",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017872",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-88201",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2373",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88201"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017872"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2373"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40854"
      }
    ]
  },
  "id": "VAR-202209-1991",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88201"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88201"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:06:07.370000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC18 fast_setting_wifi_set stack overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/372601"
      },
      {
        "title": "Tenda AC18 Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209424"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88201"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2373"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017872"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40854"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.0,
        "url": "https://github.com/cpseek/router-vuls/blob/main/tenda/ac18/form_fast_setting_wifi_set.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-40854"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-40854/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88201"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017872"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2373"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40854"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88201"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017872"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2373"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40854"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-17T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-88201"
      },
      {
        "date": "2023-10-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017872"
      },
      {
        "date": "2022-09-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-2373"
      },
      {
        "date": "2022-09-23T15:15:14.417000",
        "db": "NVD",
        "id": "CVE-2022-40854"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-88201"
      },
      {
        "date": "2023-10-17T08:03:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017872"
      },
      {
        "date": "2022-09-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-2373"
      },
      {
        "date": "2022-09-28T14:04:22.177000",
        "db": "NVD",
        "id": "CVE-2022-40854"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2373"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017872"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2373"
      }
    ],
    "trust": 0.6
  }
}

var-202209-1834
Vulnerability from variot

Tenda AC15 and AC18 routers V15.03.05.19 contain stack overflow vulnerabilities in the function fromDhcpListClient with a combined parameter "list" ("%s%d","list"). Tenda of AC15 firmware and AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Both the Tenda AC15 and Tenda AC18 are products of the Chinese company Tenda. Tenda AC15 is a wireless router. Tenda AC18 is a router. The vulnerability is caused by the fact that the fromDhcpListClient method does not check the size of the input data with the combination parameter list. Attackers can exploit the vulnerability to cause remote code execution or denial of service

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202209-1834",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88194"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017553"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40869"
      }
    ]
  },
  "cve": "CVE-2022-40869",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-88194",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-40869",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-40869",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-40869",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-40869",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-88194",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202209-2390",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88194"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017553"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2390"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40869"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC15 and AC18 routers V15.03.05.19 contain stack overflow vulnerabilities in the function fromDhcpListClient with a combined parameter \"list*\" (\"%s%d\",\"list\"). Tenda of AC15 firmware and AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Both the Tenda AC15 and Tenda AC18 are products of the Chinese company Tenda. Tenda AC15 is a wireless router. Tenda AC18 is a router. The vulnerability is caused by the fact that the fromDhcpListClient method does not check the size of the input data with the combination parameter list*. Attackers can exploit the vulnerability to cause remote code execution or denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-40869"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017553"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-88194"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-40869",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017553",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-88194",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2390",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88194"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017553"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2390"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40869"
      }
    ]
  },
  "id": "VAR-202209-1834",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88194"
      }
    ],
    "trust": 1.001633365
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88194"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:37:17.792000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC15 and AC18 fromDhcpListClient stack overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/372396"
      },
      {
        "title": "Tenda AC15  and Tenda AC18 Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=208893"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88194"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2390"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017553"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40869"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.0,
        "url": "https://github.com/cpseek/router-vuls/blob/main/tenda/ac18/fromdhcplistclient-list.md"
      },
      {
        "trust": 2.4,
        "url": "https://github.com/cpseek/router-vuls/blob/main/tenda/ac15/fromdhcplistclient-list.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-40869"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-40869/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88194"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017553"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2390"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40869"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88194"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017553"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2390"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40869"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-17T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-88194"
      },
      {
        "date": "2023-10-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017553"
      },
      {
        "date": "2022-09-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-2390"
      },
      {
        "date": "2022-09-23T14:15:13.393000",
        "db": "NVD",
        "id": "CVE-2022-40869"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-88194"
      },
      {
        "date": "2023-10-13T08:42:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017553"
      },
      {
        "date": "2022-09-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-2390"
      },
      {
        "date": "2022-09-23T20:17:05.990000",
        "db": "NVD",
        "id": "CVE-2022-40869"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2390"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC15\u00a0 firmware and \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017553"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2390"
      }
    ],
    "trust": 0.6
  }
}

var-202301-1836
Vulnerability from variot

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/initIpAddrInfo. Tenda AC18 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC18 is a router of Tenda company. Attackers can use this vulnerability to submit special requests, crash the program or execute arbitrary code in the context

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202301-1836",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21672"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002365"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24165"
      }
    ]
  },
  "cve": "CVE-2023-24165",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-21672",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-24165",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-24165",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-24165",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-24165",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-21672",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202301-1991",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21672"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002365"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1991"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24165"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/initIpAddrInfo. Tenda AC18 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC18 is a router of Tenda company. Attackers can use this vulnerability to submit special requests, crash the program or execute arbitrary code in the context",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-24165"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002365"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-21672"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24165"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-24165",
        "trust": 3.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002365",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-21672",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1991",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24165",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21672"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24165"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002365"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1991"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24165"
      }
    ]
  },
  "id": "VAR-202301-1836",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21672"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21672"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:30:46.685000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.tendacn.com/region/default.html"
      },
      {
        "title": "Patch for Tenda AC18 buffer overflow vulnerability (CNVD-2023-21672)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/416306"
      },
      {
        "title": "Tenda AC18 Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=223550"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21672"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002365"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1991"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002365"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24165"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://github.com/drizzlingsun/tenda/blob/main/ac18/7/7.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-24165"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-24165/"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21672"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24165"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002365"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1991"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24165"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21672"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24165"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002365"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1991"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24165"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-21672"
      },
      {
        "date": "2023-01-26T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-24165"
      },
      {
        "date": "2023-07-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-002365"
      },
      {
        "date": "2023-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202301-1991"
      },
      {
        "date": "2023-01-26T21:18:16.283000",
        "db": "NVD",
        "id": "CVE-2023-24165"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-21672"
      },
      {
        "date": "2023-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-24165"
      },
      {
        "date": "2023-07-07T04:42:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-002365"
      },
      {
        "date": "2023-02-02T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202301-1991"
      },
      {
        "date": "2023-02-01T20:41:10.093000",
        "db": "NVD",
        "id": "CVE-2023-24165"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1991"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0AC18\u00a0 Out-of-bounds write vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002365"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1991"
      }
    ],
    "trust": 0.6
  }
}

var-202211-1393
Vulnerability from variot

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function form_fast_setting_wifi_set.

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1393",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44171"
      }
    ]
  },
  "cve": "CVE-2022-44171",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-44171",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-44171",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-3235",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3235"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44171"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function form_fast_setting_wifi_set.",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44171"
      }
    ],
    "trust": 1.0
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-44171",
        "trust": 1.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3235",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3235"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44171"
      }
    ]
  },
  "id": "VAR-202211-1393",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T15:21:29.814000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44171"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/robinwang825/iot_vuln/blob/main/tenda/ac18/fast_setting_wifi_set/tenda_ac18_v15.03.05.19_vuln_timezone.md"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-44171/"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3235"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44171"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3235"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44171"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3235"
      },
      {
        "date": "2022-11-21T18:15:22.040000",
        "db": "NVD",
        "id": "CVE-2022-44171"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3235"
      },
      {
        "date": "2022-11-28T13:42:19.070000",
        "db": "NVD",
        "id": "CVE-2022-44171"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3235"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 Security hole",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3235"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3235"
      }
    ],
    "trust": 0.6
  }
}

var-202206-0973
Vulnerability from variot

Tenda AC18 router V15.03.05.19 and V15.03.05.05 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac. Tenda of AC18 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC18 is a router made by Chinese company Tenda. An attacker could exploit the vulnerability to cause arbitrary code execution

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202206-0973",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.19"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.05"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15693"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-011287"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31446"
      }
    ]
  },
  "cve": "CVE-2022-31446",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-31446",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-15693",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-31446",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-31446",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-31446",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-31446",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-15693",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202206-1231",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-31446",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15693"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31446"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-011287"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-1231"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31446"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 router V15.03.05.19 and V15.03.05.05 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac. Tenda of AC18 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC18 is a router made by Chinese company Tenda. An attacker could exploit the vulnerability to cause arbitrary code execution",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-31446"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-011287"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-15693"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31446"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-31446",
        "trust": 3.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-011287",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-15693",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-1231",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31446",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15693"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31446"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-011287"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-1231"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31446"
      }
    ]
  },
  "id": "VAR-202206-0973",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15693"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15693"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:32:46.773000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.0
      },
      {
        "problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-011287"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31446"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/wshidamowang/router/blob/main/tenda/ac18/rce_1.md"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-31446"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-31446/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/77.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15693"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31446"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-011287"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-1231"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31446"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15693"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31446"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-011287"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-1231"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31446"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-15693"
      },
      {
        "date": "2022-06-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-31446"
      },
      {
        "date": "2023-08-21T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-011287"
      },
      {
        "date": "2022-06-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202206-1231"
      },
      {
        "date": "2022-06-14T03:15:08.200000",
        "db": "NVD",
        "id": "CVE-2022-31446"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-15693"
      },
      {
        "date": "2022-06-18T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-31446"
      },
      {
        "date": "2023-08-21T08:19:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-011287"
      },
      {
        "date": "2022-06-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202206-1231"
      },
      {
        "date": "2024-11-21T07:04:28.257000",
        "db": "NVD",
        "id": "CVE-2022-31446"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-1231"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC18\u00a0 in the firmware \u00a0OS\u00a0 Command injection vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-011287"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-1231"
      }
    ],
    "trust": 0.6
  }
}

var-202210-1267
Vulnerability from variot

Tenda AC18 V15.03.05.19(6318) was discovered to contain a stack overflow via the time parameter in the fromSetSysTime function. Tenda AC18 is a router made by Chinese company Tenda. An attacker could exploit the vulnerability to cause a denial of service

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202210-1267",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-18958"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43260"
      }
    ]
  },
  "cve": "CVE-2022-43260",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-18958",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-43260",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-43260",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-18958",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202210-1193",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-18958"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202210-1193"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43260"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.19(6318) was discovered to contain a stack overflow via the time parameter in the fromSetSysTime function. Tenda AC18 is a router made by Chinese company Tenda. An attacker could exploit the vulnerability to cause a denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43260"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-18958"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-43260",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-18958",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202210-1193",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-18958"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202210-1193"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43260"
      }
    ]
  },
  "id": "VAR-202210-1267",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-18958"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-18958"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:30:56.985000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43260"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://drive.google.com/file/d/1elsfijqhseldzrnuawgfchd4ul4n8_mm/view?usp=sharing"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-43260"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-43260/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-18958"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202210-1193"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43260"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-18958"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202210-1193"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43260"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-22T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-18958"
      },
      {
        "date": "2022-10-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202210-1193"
      },
      {
        "date": "2022-10-18T15:15:10.433000",
        "db": "NVD",
        "id": "CVE-2022-43260"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-22T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-18958"
      },
      {
        "date": "2022-10-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202210-1193"
      },
      {
        "date": "2022-10-20T15:43:50.987000",
        "db": "NVD",
        "id": "CVE-2022-43260"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202210-1193"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 stack overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-18958"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202210-1193"
      }
    ],
    "trust": 0.6
  }
}

var-202005-0457
Vulnerability from variot

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/SetSpeedWan speed_dir parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202005-0457",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.06.42_multi"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      },
      {
        "model": "ac15 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac18 ) cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19(6318"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac6_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      }
    ]
  },
  "cve": "CVE-2020-13391",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-13391",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.1,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005745",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-31397",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-13391",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005745",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-13391",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-005745",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-31397",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202005-1141",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-13391",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/SetSpeedWan speed_dir parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-13391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13391"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-13391",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1141",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13391",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "id": "VAR-202005-0457",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      }
    ],
    "trust": 1.38075707625
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:41:05.729000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://tendacn.com/en"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13391-tenda-vulnerability/"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13391"
      },
      {
        "trust": 1.7,
        "url": "https://joel-malwarebenchmark.github.io"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13391"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/120.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-13391"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      },
      {
        "date": "2020-05-22T17:15:11.177000",
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "date": "2020-05-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-13391"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "date": "2020-05-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      },
      {
        "date": "2024-11-21T05:01:09.953000",
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Classic buffer overflow vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      }
    ],
    "trust": 0.6
  }
}

var-201711-0630
Vulnerability from variot

Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318)cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the "sub_A6E8 usbeject_process_entry" function executes a system function with untrusted input. Shenzhen Tenda Ac9 , Ac15 ,and Ac18 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. ShenzhenTendaAc9 and other are the wireless router products of Tenda. App_data_center is one of the application data centers. There is a command injection vulnerability in app_data_center in several ShenzhenTenda products. The following versions are affected: Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01 Version, Ac9 ac9_kf_V15.03.05.19(6318)cn Version, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01 Version, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01 Version, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01 version, Ac18 ac18_kf_V15.03.05.19(6318)_cn devices version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201711-0630",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac15v1.0br_v15.03.05.18_multi_td01"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac15v1.0br_v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac18v1.0br_v15.03.05.05_multi_td01"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac9v1.0br_v15.03.05.14_multi_td01"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "ac9_kf_v15.03.05.19\\(6318_\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "ac18_kf_v15.03.05.19\\(6318_\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18_kf_v15.03.05.19(6318_)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9_kf_v15.03.05.19(6318_)_cn"
      },
      {
        "model": "tenda technology co.,ltd. w15e devices",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac9 us_ac9v1.0br_v15.03.05.14_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac9 ac9_kf_v15.03.05.19 _cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac9 ac15 us_ac15v1.0br_v15.03.05.18_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac9 ac15 us_ac15v1.0br_v15.03.05.19_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac9 ac18 us_ac18v1.0br_v15.03.05.05_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac9 ac18 ac18_kf_v15.03.05.19 _cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      }
    ]
  },
  "cve": "CVE-2017-16923",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 6.5,
            "id": "CVE-2017-16923",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2017-37811",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 6.5,
            "id": "VHN-107894",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:A/AC:L/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2017-16923",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-16923",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-16923",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-37811",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201711-888",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-107894",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107894"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the \"sub_A6E8 usbeject_process_entry\" function executes a system function with untrusted input. Shenzhen Tenda Ac9 , Ac15 ,and Ac18 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. ShenzhenTendaAc9 and other are the wireless router products of Tenda. App_data_center is one of the application data centers. There is a command injection vulnerability in app_data_center in several ShenzhenTenda products. The following versions are affected: Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01 Version, Ac9 ac9_kf_V15.03.05.19(6318_)_cn Version, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01 Version, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01 Version, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01 version, Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-16923"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107894"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-16923",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-107894",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107894"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "id": "VAR-201711-0630",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107894"
      }
    ],
    "trust": 1.1153522033333332
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:45:33.771000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://tendacn.com/en/default.html"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-77",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-107894"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/iolop/poc/tree/master/router/tenda"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-16923"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-16923"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107894"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107894"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-12-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "date": "2017-11-21T00:00:00",
        "db": "VULHUB",
        "id": "VHN-107894"
      },
      {
        "date": "2017-12-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "date": "2017-11-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      },
      {
        "date": "2017-11-21T14:29:00.260000",
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-12-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-107894"
      },
      {
        "date": "2017-12-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      },
      {
        "date": "2024-11-21T03:17:14.913000",
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Shenzhen Tenda Command injection vulnerability in devices",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "operating system commend injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      }
    ],
    "trust": 0.6
  }
}

var-202205-1981
Vulnerability from variot

Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetClientState request.

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202205-1981",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30477"
      }
    ]
  },
  "cve": "CVE-2022-30477",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-30477",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-30477",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-30477",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202205-4192",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4192"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30477"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetClientState request.",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30477"
      }
    ],
    "trust": 1.0
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-30477",
        "trust": 1.6
      },
      {
        "db": "CS-HELP",
        "id": "SB2022052708",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4192",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4192"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30477"
      }
    ]
  },
  "id": "VAR-202205-1981",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-11-23T22:10:45.264000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30477"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/lcyfrank/vulnrepo/tree/master/iot/tenda/4"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2022052708"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-30477/"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4192"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30477"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4192"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30477"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-4192"
      },
      {
        "date": "2022-05-26T16:15:08.677000",
        "db": "NVD",
        "id": "CVE-2022-30477"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-06-06T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-4192"
      },
      {
        "date": "2024-11-21T07:02:49.183000",
        "db": "NVD",
        "id": "CVE-2022-30477"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4192"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC Series Router Buffer error vulnerability",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4192"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4192"
      }
    ],
    "trust": 0.6
  }
}

var-202301-1972
Vulnerability from variot

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/add_white_node. Tenda AC18 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC18 is a router of Tenda company. Attackers can use this vulnerability to submit special requests, crash the program or execute arbitrary code in the context

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202301-1972",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21674"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002363"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24167"
      }
    ]
  },
  "cve": "CVE-2023-24167",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-21674",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-24167",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-24167",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-24167",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-24167",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-21674",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202301-1990",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21674"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002363"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1990"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24167"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/add_white_node. Tenda AC18 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC18 is a router of Tenda company. Attackers can use this vulnerability to submit special requests, crash the program or execute arbitrary code in the context",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-24167"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002363"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-21674"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24167"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-24167",
        "trust": 3.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002363",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-21674",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1990",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24167",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21674"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24167"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002363"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1990"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24167"
      }
    ]
  },
  "id": "VAR-202301-1972",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21674"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21674"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:10:20.691000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.tendacn.com/region/default.html"
      },
      {
        "title": "Patch for Tenda AC18 buffer overflow vulnerability (CNVD-2023-21674)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/416311"
      },
      {
        "title": "Tenda AC18 Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=223549"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21674"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002363"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1990"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002363"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24167"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://github.com/drizzlingsun/tenda/blob/main/ac18/1/1.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-24167"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-24167/"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21674"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24167"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002363"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1990"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24167"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21674"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24167"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002363"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1990"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24167"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-21674"
      },
      {
        "date": "2023-01-26T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-24167"
      },
      {
        "date": "2023-07-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-002363"
      },
      {
        "date": "2023-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202301-1990"
      },
      {
        "date": "2023-01-26T21:18:16.433000",
        "db": "NVD",
        "id": "CVE-2023-24167"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-21674"
      },
      {
        "date": "2023-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-24167"
      },
      {
        "date": "2023-07-07T04:35:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-002363"
      },
      {
        "date": "2023-02-02T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202301-1990"
      },
      {
        "date": "2023-02-01T20:27:41.963000",
        "db": "NVD",
        "id": "CVE-2023-24167"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1990"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0AC18\u00a0 Out-of-bounds write vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002363"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1990"
      }
    ],
    "trust": 0.6
  }
}

var-201809-0930
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server. While processing the ssid parameter for a POST request, the value is directly used in a sprintf call to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow. plural Tenda Product Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7, etc. are all wireless router products of China Tenda. An attacker can use this vulnerability to cause a denial of service. The following products and versions are affected: Tenda AC7 15.03.06.44_CN Version; AC9 15.03.05.19(6318)_CN Version; AC10 15.03.06.23_CN Version; AC15 15.03.05.19_CN Version; AC18 15.03.05.19(6318)_CN Version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0930",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tendacn",
        "version": "15.03.06.23"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tendacn",
        "version": "15.03.06.44"
      },
      {
        "model": "ac18",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9 15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7 15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tendacn:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      }
    ]
  },
  "cve": "CVE-2018-16333",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-16333",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-35175",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-126682",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-16333",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-16333",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-16333",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-35175",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201809-036",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-126682",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2018-16333",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-16333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server. While processing the ssid parameter for a POST request, the value is directly used in a sprintf call to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow. plural Tenda Product Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7, etc. are all wireless router products of China Tenda. An attacker can use this vulnerability to cause a denial of service. The following products and versions are affected: Tenda AC7 15.03.06.44_CN Version; AC9 15.03.05.19(6318)_CN Version; AC10 15.03.06.23_CN Version; AC15 15.03.05.19_CN Version; AC18 15.03.05.19(6318)_CN Version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-16333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-16333"
      }
    ],
    "trust": 2.34
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-16333",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-126682",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-16333",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-16333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "id": "VAR-201809-0930",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126682"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:38:03.789000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      },
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/kal1x/iotvulhub "
      },
      {
        "title": "Routers",
        "trust": 0.1,
        "url": "https://github.com/ZIllR0/Routers "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2018-16333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/oob1.md"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-16333"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-16333"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/119.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/kal1x/iotvulhub"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/zillr0/routers"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-16333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-16333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "date": "2018-09-02T00:00:00",
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "date": "2018-09-02T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-16333"
      },
      {
        "date": "2018-11-19T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "date": "2018-09-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      },
      {
        "date": "2018-09-02T03:29:00.620000",
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "date": "2018-10-25T00:00:00",
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "date": "2018-10-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-16333"
      },
      {
        "date": "2018-11-19T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "date": "2018-09-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      },
      {
        "date": "2024-11-21T03:52:32.530000",
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      }
    ],
    "trust": 0.6
  }
}

var-202211-1323
Vulnerability from variot

Tenda AC18 V15.03.05.05 is vulnerable to Buffer Overflow via function formSetDeviceName.

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1323",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.05"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44174"
      }
    ]
  },
  "cve": "CVE-2022-44174",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-44174",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-44174",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-3233",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3233"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44174"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.05 is vulnerable to Buffer Overflow via function formSetDeviceName.",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44174"
      }
    ],
    "trust": 1.0
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-44174",
        "trust": 1.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3233",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3233"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44174"
      }
    ]
  },
  "id": "VAR-202211-1323",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T14:49:30.246000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44174"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/robinwang825/iot_vuln/blob/main/tenda/ac18/formsetdevicename_05/tenda_ac18_v15.03.05.05_vuln_devname.md"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-44174/"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3233"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44174"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3233"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44174"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3233"
      },
      {
        "date": "2022-11-21T18:15:22.660000",
        "db": "NVD",
        "id": "CVE-2022-44174"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3233"
      },
      {
        "date": "2022-11-28T13:45:14.600000",
        "db": "NVD",
        "id": "CVE-2022-44174"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3233"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 Security hole",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3233"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3233"
      }
    ],
    "trust": 0.6
  }
}

var-202403-1075
Vulnerability from variot

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202403-1075",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003018"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-28535"
      }
    ]
  },
  "cve": "CVE-2024-28535",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2024-28535",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "HIGH",
            "baseScore": 8.0,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.1,
            "id": "CVE-2024-28535",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-28535",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-28535",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2024-28535",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2024-28535",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003018"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-28535"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-28535"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-28535"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003018"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-28535",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003018",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003018"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-28535"
      }
    ]
  },
  "id": "VAR-202403-1075",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T13:41:10.670000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003018"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-28535"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac18/fromaddressnat_mitinterface.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-28535"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003018"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-28535"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003018"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-28535"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-003018"
      },
      {
        "date": "2024-03-12T13:15:49.690000",
        "db": "NVD",
        "id": "CVE-2024-28535"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-25T06:39:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-003018"
      },
      {
        "date": "2024-08-01T13:49:07.553000",
        "db": "NVD",
        "id": "CVE-2024-28535"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003018"
      }
    ],
    "trust": 0.8
  }
}

var-202102-0327
Vulnerability from variot

A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PCT files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12182). JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write. Zero Day Initiative To this vulnerability ZDI-CAN-12182 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PCT files. The Tenda AC18 is a router from the Chinese company Tenda

Show details on source website


{
  "affected_products": {
    "_id": null,
    "data": [
      {
        "_id": null,
        "model": "teamcenter visualization",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "13.1.0.1"
      },
      {
        "_id": null,
        "model": "jt2go",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "13.1.0.1"
      },
      {
        "_id": null,
        "model": "jt2go",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "_id": null,
        "model": "teamcenter visualization",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": "13.1.0.1"
      },
      {
        "_id": null,
        "model": "jt2go",
        "scope": null,
        "trust": 0.7,
        "vendor": "siemens",
        "version": null
      },
      {
        "_id": null,
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.05"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-232"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015914"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-27006"
      }
    ]
  },
  "credits": {
    "_id": null,
    "data": "Francis Provencher {PRL}",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-232"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2020-27006",
  "cvss": {
    "_id": null,
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-27006",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-75821",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2020-27006",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2020-27006",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2020-27006",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "REQUIRED",
            "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-27006",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2020-27006",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "ZDI",
            "id": "CVE-2020-27006",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-75821",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202102-864",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-232"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015914"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-864"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-27006"
      }
    ]
  },
  "description": {
    "_id": null,
    "data": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0.1), Teamcenter Visualization (All versions \u003c V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PCT files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12182). JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write. Zero Day Initiative To this vulnerability ZDI-CAN-12182 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PCT files. The Tenda AC18 is a router from the Chinese company Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-27006"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015914"
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-232"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      }
    ],
    "trust": 2.79
  },
  "external_ids": {
    "_id": null,
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-27006",
        "trust": 3.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-232",
        "trust": 3.1
      },
      {
        "db": "SIEMENS",
        "id": "SSA-663999",
        "trust": 1.6
      },
      {
        "db": "JVN",
        "id": "JVNVU91083521",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015914",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-12182",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-040-06",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0495",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-864",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-232"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015914"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-864"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-27006"
      }
    ]
  },
  "id": "VAR-202102-0327",
  "iot": {
    "_id": null,
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "_id": null,
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      }
    ]
  },
  "last_update_date": "2024-11-23T20:13:55.452000Z",
  "patch": {
    "_id": null,
    "data": [
      {
        "title": "SSA-663999",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
      },
      {
        "title": "Siemens has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
      },
      {
        "title": "JT2Go Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=141286"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-232"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015914"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-864"
      }
    ]
  },
  "problemtype_data": {
    "_id": null,
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015914"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-27006"
      }
    ]
  },
  "references": {
    "_id": null,
    "data": [
      {
        "trust": 2.4,
        "url": "https://www.zerodayinitiative.com/advisories/zdi-21-232/"
      },
      {
        "trust": 1.6,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27006"
      },
      {
        "trust": 1.3,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91083521/"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0495"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-232"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015914"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-864"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-27006"
      }
    ]
  },
  "sources": {
    "_id": null,
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-21-232",
        "ident": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821",
        "ident": null
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015914",
        "ident": null
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-864",
        "ident": null
      },
      {
        "db": "NVD",
        "id": "CVE-2020-27006",
        "ident": null
      }
    ]
  },
  "sources_release_date": {
    "_id": null,
    "data": [
      {
        "date": "2021-02-24T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-232",
        "ident": null
      },
      {
        "date": "2022-11-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-75821",
        "ident": null
      },
      {
        "date": "2021-10-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015914",
        "ident": null
      },
      {
        "date": "2021-02-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202102-864",
        "ident": null
      },
      {
        "date": "2021-02-09T17:15:14.343000",
        "db": "NVD",
        "id": "CVE-2020-27006",
        "ident": null
      }
    ]
  },
  "sources_update_date": {
    "_id": null,
    "data": [
      {
        "date": "2021-02-24T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-232",
        "ident": null
      },
      {
        "date": "2022-11-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-75821",
        "ident": null
      },
      {
        "date": "2021-10-22T08:12:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015914",
        "ident": null
      },
      {
        "date": "2021-10-19T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202102-864",
        "ident": null
      },
      {
        "date": "2024-11-21T05:20:40.170000",
        "db": "NVD",
        "id": "CVE-2020-27006",
        "ident": null
      }
    ]
  },
  "threat_type": {
    "_id": null,
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-864"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "_id": null,
    "data": "JT2Go\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds Vulnerability in Microsoft",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015914"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "_id": null,
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-864"
      }
    ],
    "trust": 0.6
  }
}

var-202209-0428
Vulnerability from variot

Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the urls parameter at /goform/saveParentControlInfo. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202209-0428",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.19(6318)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016267"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38314"
      }
    ]
  },
  "cve": "CVE-2022-38314",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-38314",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-38314",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-38314",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-38314",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202209-454",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016267"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-454"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38314"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the urls parameter at /goform/saveParentControlInfo. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-38314"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016267"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-38314",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016267",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-454",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016267"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-454"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38314"
      }
    ]
  },
  "id": "VAR-202209-0428",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T14:24:32.101000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016267"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38314"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/rickytriky/nwpu_projct/tree/main/tenda/ac18/1"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-38314"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-38314/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016267"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-454"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38314"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016267"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-454"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38314"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-03T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016267"
      },
      {
        "date": "2022-09-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-454"
      },
      {
        "date": "2022-09-07T19:15:08.917000",
        "db": "NVD",
        "id": "CVE-2022-38314"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-03T08:07:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016267"
      },
      {
        "date": "2022-09-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-454"
      },
      {
        "date": "2022-09-10T03:23:59.603000",
        "db": "NVD",
        "id": "CVE-2022-38314"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-454"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016267"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-454"
      }
    ],
    "trust": 0.6
  }
}

var-202301-1835
Vulnerability from variot

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/fromSetWirelessRepeat. Tenda AC18 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC18 is a router of Tenda Company. Attackers can use this vulnerability to submit special requests, crash the program or execute arbitrary code in the context

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202301-1835",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21676"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002362"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24170"
      }
    ]
  },
  "cve": "CVE-2023-24170",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-21676",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-24170",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-24170",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-24170",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-24170",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-21676",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202301-1988",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21676"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002362"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1988"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24170"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/fromSetWirelessRepeat. Tenda AC18 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC18 is a router of Tenda Company. Attackers can use this vulnerability to submit special requests, crash the program or execute arbitrary code in the context",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-24170"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002362"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-21676"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24170"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-24170",
        "trust": 3.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002362",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-21676",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1988",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24170",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21676"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24170"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002362"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1988"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24170"
      }
    ]
  },
  "id": "VAR-202301-1835",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21676"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21676"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:37:10.619000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.tendacn.com/region/default.html"
      },
      {
        "title": "Patch for Tenda AC18 buffer overflow vulnerability (CNVD-2023-21676)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/416321"
      },
      {
        "title": "Tenda AC18 Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=223547"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21676"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002362"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1988"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002362"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24170"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://github.com/drizzlingsun/tenda/blob/main/ac18/3/3.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-24170"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-24170/"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21676"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24170"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002362"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1988"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24170"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21676"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24170"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002362"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1988"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24170"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-21676"
      },
      {
        "date": "2023-01-26T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-24170"
      },
      {
        "date": "2023-07-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-002362"
      },
      {
        "date": "2023-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202301-1988"
      },
      {
        "date": "2023-01-26T21:18:16.567000",
        "db": "NVD",
        "id": "CVE-2023-24170"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-21676"
      },
      {
        "date": "2023-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-24170"
      },
      {
        "date": "2023-07-07T04:31:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-002362"
      },
      {
        "date": "2023-02-02T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202301-1988"
      },
      {
        "date": "2023-02-01T20:25:05.187000",
        "db": "NVD",
        "id": "CVE-2023-24170"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1988"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0AC18\u00a0 Out-of-bounds write vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002362"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1988"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0245
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromAddressNat" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. An attacker could exploit the vulnerability to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0245",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      }
    ]
  },
  "cve": "CVE-2018-18708",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18708",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-22313",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129294",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18708",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18708",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18708",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-22313",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1339",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129294",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2018-18708",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. An attacker could exploit the vulnerability to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18708"
      }
    ],
    "trust": 2.34
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18708",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129294",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18708",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "id": "VAR-201810-0245",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129294"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:38:16.715000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      },
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/saber0x0/iot_sec_learn "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2018-18708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.2,
        "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/tenda.md"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18708"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18708"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/119.html"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/saber0x0/iot_sec_learn"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-11-01T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-18708"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      },
      {
        "date": "2018-10-29T12:29:05.617000",
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-11-01T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-18708"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "date": "2018-10-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      },
      {
        "date": "2024-11-21T03:56:25.030000",
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      }
    ],
    "trust": 0.6
  }
}

var-202403-0889
Vulnerability from variot

A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC18 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0889",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.05"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003029"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2854"
      }
    ]
  },
  "cve": "CVE-2024-2854",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CVE-2024-2854",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 2.8,
            "id": "CVE-2024-2854",
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2024-2854",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-2854",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-2854",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-2854",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2024-2854",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003029"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2854"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2854"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC18 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-2854"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003029"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-2854",
        "trust": 2.6
      },
      {
        "db": "VULDB",
        "id": "257778",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003029",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003029"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2854"
      }
    ]
  },
  "id": "VAR-202403-0889",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T14:01:19.637000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.0
      },
      {
        "problemtype": "OS Command injection (CWE-78) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003029"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2854"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac18/formsetsambaconf.md"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.257778"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.257778"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2854"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003029"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2854"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003029"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2854"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-003029"
      },
      {
        "date": "2024-03-24T06:15:08.633000",
        "db": "NVD",
        "id": "CVE-2024-2854"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-28T00:47:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-003029"
      },
      {
        "date": "2024-05-17T02:38:34.440000",
        "db": "NVD",
        "id": "CVE-2024-2854"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC18\u00a0 in the firmware \u00a0OS\u00a0 Command injection vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003029"
      }
    ],
    "trust": 0.8
  }
}

var-202211-1363
Vulnerability from variot

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function addWifiMacFilter. Tenda AC18 is a router made by Chinese company Tenda. The vulnerability is caused by the fact that the addWifiMacFilter function does not check the length of the input data. Attackers can exploit the vulnerability to cause denial of service

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1363",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87026"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44180"
      }
    ]
  },
  "cve": "CVE-2022-44180",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-87026",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-44180",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-44180",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-87026",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-3227",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87026"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3227"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44180"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function addWifiMacFilter. Tenda AC18 is a router made by Chinese company Tenda. The vulnerability is caused by the fact that the addWifiMacFilter function does not check the length of the input data. Attackers can exploit the vulnerability to cause denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44180"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-87026"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-44180",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-87026",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3227",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87026"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3227"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44180"
      }
    ]
  },
  "id": "VAR-202211-1363",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87026"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87026"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:26:58.586000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44180"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://github.com/robinwang825/iot_vuln/tree/main/tenda/ac18/addwifimacfilter"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-44180/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87026"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3227"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44180"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87026"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3227"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44180"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-87026"
      },
      {
        "date": "2022-11-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3227"
      },
      {
        "date": "2022-11-21T18:15:24.370000",
        "db": "NVD",
        "id": "CVE-2022-44180"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-87026"
      },
      {
        "date": "2022-11-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3227"
      },
      {
        "date": "2022-11-28T13:51:28.233000",
        "db": "NVD",
        "id": "CVE-2022-44180"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3227"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 addWifiMacFilter function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87026"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3227"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0278
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'ntpServer' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0278",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      }
    ]
  },
  "cve": "CVE-2018-18732",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18732",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-01883",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129321",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18732",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18732",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18732",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-01883",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1359",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129321",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129321"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18732"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129321"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18732",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1359",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129321",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129321"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "id": "VAR-201810-0278",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129321"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      }
    ]
  },
  "last_update_date": "2024-11-23T23:04:57.538000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129321"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/stack2.md"
      },
      {
        "trust": 1.4,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18732"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18732"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129321"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129321"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129321"
      },
      {
        "date": "2019-03-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      },
      {
        "date": "2018-10-29T12:29:07.960000",
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "date": "2019-01-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129321"
      },
      {
        "date": "2019-03-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "date": "2019-04-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      },
      {
        "date": "2024-11-21T03:56:28.703000",
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0277
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceMac' parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0277",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      }
    ]
  },
  "cve": "CVE-2018-18731",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18731",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-01884",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129320",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18731",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18731",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18731",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-01884",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1358",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129320",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129320"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18731"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129320"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18731",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1358",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129320",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129320"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "id": "VAR-201810-0277",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129320"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:52:47.617000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129320"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/stack4.md"
      },
      {
        "trust": 1.4,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18731"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18731"
      },
      {
        "trust": 0.8,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/stack2.md"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129320"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129320"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129320"
      },
      {
        "date": "2019-03-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      },
      {
        "date": "2018-10-29T12:29:07.837000",
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "date": "2019-01-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129320"
      },
      {
        "date": "2019-03-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "date": "2019-04-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      },
      {
        "date": "2024-11-21T03:56:28.527000",
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      }
    ],
    "trust": 0.6
  }
}

var-202208-1483
Vulnerability from variot

Tenda-AC18 V15.03.05.05 was discovered to contain a remote command execution (RCE) vulnerability. Shenzhen Tenda Technology Co.,Ltd. of AC18 There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202208-1483",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.05"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015351"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-35201"
      }
    ]
  },
  "cve": "CVE-2022-35201",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-75821",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-35201",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-35201",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-35201",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-35201",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-75821",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202208-3572",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015351"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3572"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-35201"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda-AC18 V15.03.05.05 was discovered to contain a remote command execution (RCE) vulnerability. Shenzhen Tenda Technology Co.,Ltd. of AC18 There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-35201"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015351"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-35201"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-35201",
        "trust": 3.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015351",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3572",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-35201",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-35201"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015351"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3572"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-35201"
      }
    ]
  },
  "id": "VAR-202208-1483",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      }
    ]
  },
  "last_update_date": "2024-08-14T13:07:18.428000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-noinfo",
        "trust": 1.0
      },
      {
        "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015351"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-35201"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://www.tendacn.com/default.html"
      },
      {
        "trust": 1.7,
        "url": "http://tenda-ac18.com"
      },
      {
        "trust": 1.7,
        "url": "http://124.222.176.39/21f93b5e3b39b22b6df1e6a9c61ed70d54e8378bbeacd844efff921b9a1a8624/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-35201"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27006"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-35201/"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-35201"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015351"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3572"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-35201"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-35201"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015351"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3572"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-35201"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      },
      {
        "date": "2022-08-19T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-35201"
      },
      {
        "date": "2023-09-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-015351"
      },
      {
        "date": "2022-08-19T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-3572"
      },
      {
        "date": "2022-08-19T15:15:08.417000",
        "db": "NVD",
        "id": "CVE-2022-35201"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-75821"
      },
      {
        "date": "2022-08-19T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-35201"
      },
      {
        "date": "2023-09-26T08:26:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-015351"
      },
      {
        "date": "2022-08-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-3572"
      },
      {
        "date": "2024-02-14T01:17:43.863000",
        "db": "NVD",
        "id": "CVE-2022-35201"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3572"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC18\u00a0 Firmware vulnerabilities",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015351"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3572"
      }
    ],
    "trust": 0.6
  }
}

var-202209-0416
Vulnerability from variot

Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202209-0416",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.05"
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.19(6318)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016272"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38309"
      }
    ]
  },
  "cve": "CVE-2022-38309",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-38309",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-38309",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-38309",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-38309",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202209-447",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016272"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-447"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38309"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg. Shenzhen Tenda Technology Co.,Ltd. of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-38309"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016272"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-38309",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016272",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-447",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016272"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-447"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38309"
      }
    ]
  },
  "id": "VAR-202209-0416",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T15:27:06.548000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016272"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38309"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/rickytriky/nwpu_projct/tree/main/tenda/ac18/4"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-38309"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-38309/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016272"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-447"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38309"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016272"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-447"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-38309"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-03T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016272"
      },
      {
        "date": "2022-09-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-447"
      },
      {
        "date": "2022-09-07T19:15:08.697000",
        "db": "NVD",
        "id": "CVE-2022-38309"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-10-03T08:07:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016272"
      },
      {
        "date": "2022-09-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-447"
      },
      {
        "date": "2022-09-10T03:22:28.743000",
        "db": "NVD",
        "id": "CVE-2022-38309"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-447"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016272"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-447"
      }
    ],
    "trust": 0.6
  }
}

var-202211-1287
Vulnerability from variot

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow. via function formWifiWpsOOB. Tenda AC18 is a router made by Chinese company Tenda. The vulnerability is caused by the fact that the formWifiWpsOOB function does not check the length of the input data. Attackers can exploit the vulnerability to cause denial of service

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1287",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87028"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44178"
      }
    ]
  },
  "cve": "CVE-2022-44178",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-87028",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-44178",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-44178",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-87028",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-3226",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87028"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3226"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44178"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow. via function formWifiWpsOOB. Tenda AC18 is a router made by Chinese company Tenda. The vulnerability is caused by the fact that the formWifiWpsOOB function does not check the length of the input data. Attackers can exploit the vulnerability to cause denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44178"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-87028"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-44178",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-87028",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3226",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87028"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3226"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44178"
      }
    ]
  },
  "id": "VAR-202211-1287",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87028"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87028"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:16:21.833000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44178"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://github.com/robinwang825/iot_vuln/tree/main/tenda/ac18/formwifiwpsoob"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-44178/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87028"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3226"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44178"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87028"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3226"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44178"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-87028"
      },
      {
        "date": "2022-11-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3226"
      },
      {
        "date": "2022-11-21T18:15:23.920000",
        "db": "NVD",
        "id": "CVE-2022-44178"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-87028"
      },
      {
        "date": "2022-11-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3226"
      },
      {
        "date": "2022-11-28T13:49:51.740000",
        "db": "NVD",
        "id": "CVE-2022-44178"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3226"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 formWifiWpsOOB function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87028"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3226"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0244
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "ssid" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0244",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      }
    ]
  },
  "cve": "CVE-2018-18707",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18707",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-09141",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129293",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18707",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18707",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18707",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-09141",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1338",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129293",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129293"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18707"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129293"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18707",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129293",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129293"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "id": "VAR-201810-0244",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129293"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      }
    ]
  },
  "last_update_date": "2024-11-23T23:12:02.625000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129293"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/tenda.md"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18707"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18707"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129293"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129293"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-04-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129293"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      },
      {
        "date": "2018-10-29T12:29:05.507000",
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-04-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129293"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "date": "2018-10-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      },
      {
        "date": "2024-11-21T03:56:24.870000",
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      }
    ],
    "trust": 0.6
  }
}

var-202301-1909
Vulnerability from variot

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_000c2318. Tenda AC18 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC18 is a router of Tenda Company. Attackers can use this vulnerability to submit special requests, crash the program or execute arbitrary code in the context

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202301-1909",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21671"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002366"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24164"
      }
    ]
  },
  "cve": "CVE-2023-24164",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-21671",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-24164",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-24164",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-24164",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-24164",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-21671",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202301-1992",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21671"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002366"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1992"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24164"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_000c2318. Tenda AC18 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC18 is a router of Tenda Company. Attackers can use this vulnerability to submit special requests, crash the program or execute arbitrary code in the context",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-24164"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002366"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-21671"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24164"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-24164",
        "trust": 3.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002366",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-21671",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1992",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24164",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21671"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24164"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002366"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1992"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24164"
      }
    ]
  },
  "id": "VAR-202301-1909",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21671"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21671"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:10:20.761000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.tendacn.com/region/default.html"
      },
      {
        "title": "Patch for Tenda AC18 buffer overflow vulnerability (CNVD-2023-21671)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/416296"
      },
      {
        "title": "Tenda AC18 Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=223551"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21671"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002366"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1992"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002366"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24164"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://github.com/drizzlingsun/tenda/blob/main/ac18/4/4.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-24164"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-24164/"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21671"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24164"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002366"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1992"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24164"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21671"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24164"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002366"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1992"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24164"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-21671"
      },
      {
        "date": "2023-01-26T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-24164"
      },
      {
        "date": "2023-07-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-002366"
      },
      {
        "date": "2023-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202301-1992"
      },
      {
        "date": "2023-01-26T21:18:16.207000",
        "db": "NVD",
        "id": "CVE-2023-24164"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-21671"
      },
      {
        "date": "2023-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-24164"
      },
      {
        "date": "2023-07-07T04:59:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-002366"
      },
      {
        "date": "2023-02-02T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202301-1992"
      },
      {
        "date": "2023-02-01T20:41:38.917000",
        "db": "NVD",
        "id": "CVE-2023-24164"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1992"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0AC18\u00a0 Out-of-bounds write vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002366"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1992"
      }
    ],
    "trust": 0.6
  }
}

var-202205-1983
Vulnerability from variot

Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/WifiExtraSet request

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202205-1983",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30475"
      }
    ]
  },
  "cve": "CVE-2022-30475",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-30475",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.1,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-30475",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-30475",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202205-4198",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-30475",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30475"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4198"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30475"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/WifiExtraSet request",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30475"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-30475"
      }
    ],
    "trust": 0.99
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-30475",
        "trust": 1.7
      },
      {
        "db": "CS-HELP",
        "id": "SB2022052708",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4198",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-30475",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30475"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4198"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30475"
      }
    ]
  },
  "id": "VAR-202205-1983",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-11-23T22:10:45.246000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/lcyfrank/VulnRepo "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30475"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-30475"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://github.com/lcyfrank/vulnrepo/tree/master/iot/tenda/3"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2022052708"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-30475/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/lcyfrank/vulnrepo"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30475"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4198"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30475"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2022-30475"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4198"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-30475"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-26T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-30475"
      },
      {
        "date": "2022-05-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-4198"
      },
      {
        "date": "2022-05-26T16:15:08.577000",
        "db": "NVD",
        "id": "CVE-2022-30475"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-06-03T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-30475"
      },
      {
        "date": "2022-06-06T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-4198"
      },
      {
        "date": "2024-11-21T07:02:48.910000",
        "db": "NVD",
        "id": "CVE-2022-30475"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4198"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC Series Router Buffer error vulnerability",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4198"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4198"
      }
    ],
    "trust": 0.6
  }
}

var-202005-0459
Vulnerability from variot

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/saveParentControlInfo deviceId and time parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202005-0459",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.06.42_multi"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      },
      {
        "model": "ac15 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac18 ) cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19(6318"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac6_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      }
    ]
  },
  "cve": "CVE-2020-13393",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-13393",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005747",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-31408",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-13393",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005747",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-13393",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-005747",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-31408",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202005-1143",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/saveParentControlInfo deviceId and time parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-13393"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-13393",
        "trust": 3.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1143",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "id": "VAR-202005-0459",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      }
    ],
    "trust": 1.38075707625
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:51:21.819000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://tendacn.com/en"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13393-tenda-vulnerability/"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13393"
      },
      {
        "trust": 1.0,
        "url": "https://joel-malwarebenchmark.github.io"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13393"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      },
      {
        "date": "2020-05-22T17:15:11.300000",
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "date": "2020-05-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      },
      {
        "date": "2024-11-21T05:01:10.260000",
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Classic buffer overflow vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      }
    ],
    "trust": 0.6
  }
}

var-202301-2255
Vulnerability from variot

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet. Tenda AC18 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC18 is a router of Tenda company. Attackers can use this vulnerability to submit special requests, crash the program or execute arbitrary code in the context

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202301-2255",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21673"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002364"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24166"
      }
    ]
  },
  "cve": "CVE-2023-24166",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-21673",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-24166",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-24166",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-24166",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-24166",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-21673",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202301-1995",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21673"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002364"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1995"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24166"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet. Tenda AC18 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC18 is a router of Tenda company. Attackers can use this vulnerability to submit special requests, crash the program or execute arbitrary code in the context",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-24166"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002364"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-21673"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24166"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-24166",
        "trust": 3.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002364",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-21673",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1995",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24166",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21673"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24166"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002364"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1995"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24166"
      }
    ]
  },
  "id": "VAR-202301-2255",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21673"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21673"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:11:03.286000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.tendacn.com/region/default.html"
      },
      {
        "title": "Patch for Tenda AC18 buffer overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/416301"
      },
      {
        "title": "Tenda AC18 Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=223552"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21673"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002364"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1995"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002364"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24166"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://github.com/drizzlingsun/tenda/blob/main/ac18/2/2.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-24166"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-24166/"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21673"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24166"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002364"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1995"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24166"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21673"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-24166"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002364"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1995"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24166"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-21673"
      },
      {
        "date": "2023-01-26T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-24166"
      },
      {
        "date": "2023-07-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-002364"
      },
      {
        "date": "2023-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202301-1995"
      },
      {
        "date": "2023-01-26T21:18:16.363000",
        "db": "NVD",
        "id": "CVE-2023-24166"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-21673"
      },
      {
        "date": "2023-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-24166"
      },
      {
        "date": "2023-07-07T04:39:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-002364"
      },
      {
        "date": "2023-02-02T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202301-1995"
      },
      {
        "date": "2023-02-01T20:32:54.137000",
        "db": "NVD",
        "id": "CVE-2023-24166"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1995"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0AC18\u00a0 Out-of-bounds write vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-002364"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202301-1995"
      }
    ],
    "trust": 0.6
  }
}

var-202403-0709
Vulnerability from variot

A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda AC18 is a router made by the Chinese company Tenda. A remote attacker can exploit this vulnerability to execute on the system. Arbitrary code or lead to denial of service attacks

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0709",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "15.03.05.05"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14311"
      }
    ]
  },
  "cve": "CVE-2024-2490",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2024-2490",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2024-14311",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2024-2490",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-2490",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-14311",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14311"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2490"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda AC18 is a router made by the Chinese company Tenda. A remote attacker can exploit this vulnerability to execute on the system. Arbitrary code or lead to denial of service attacks",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-2490"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14311"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-2490",
        "trust": 1.6
      },
      {
        "db": "VULDB",
        "id": "256897",
        "trust": 1.0
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14311",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14311"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2490"
      }
    ]
  },
  "id": "VAR-202403-0709",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14311"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14311"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:48:36.161000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-2490"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.0,
        "url": "https://github.com/emilytutu/iot-vulnerable/blob/main/tenda/ac18/setschedwifi_end.md"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.256897"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?id.256897"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2490"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14311"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2490"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14311"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2490"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14311"
      },
      {
        "date": "2024-03-15T10:15:08.727000",
        "db": "NVD",
        "id": "CVE-2024-2490"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14311"
      },
      {
        "date": "2024-05-17T02:38:15.590000",
        "db": "NVD",
        "id": "CVE-2024-2490"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 setSchedWifi function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14311"
      }
    ],
    "trust": 0.6
  }
}

var-202407-0745
Vulnerability from variot

Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo. Tenda of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202407-0745",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.3.10"
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18  firmware  15.03.3.10"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004512"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-33180"
      }
    ]
  },
  "cve": "CVE-2024-33180",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2024-33180",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-33180",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-33180",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2024-33180",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2024-33180",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004512"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-33180"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-33180"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo. Tenda of AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-33180"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004512"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-33180",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004512",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004512"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-33180"
      }
    ]
  },
  "id": "VAR-202407-0745",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T14:36:11.752000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004512"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-33180"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://palm-vertebra-fe9.notion.site/saveparentcontrolinfo_1-7c9695d0251945ae8006db705b9b80ac"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-33180"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004512"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-33180"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004512"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-33180"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-07-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-004512"
      },
      {
        "date": "2024-07-16T16:15:04.767000",
        "db": "NVD",
        "id": "CVE-2024-33180"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-07-22T05:25:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-004512"
      },
      {
        "date": "2024-08-01T13:51:44.097000",
        "db": "NVD",
        "id": "CVE-2024-33180"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-004512"
      }
    ],
    "trust": 0.8
  }
}

var-202403-0744
Vulnerability from variot

A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. The vulnerability is caused by the cmdinput parameter of the formexeCommand function in the /goform/execCommand file failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute on the system. Arbitrary code or lead to denial of service attacks

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0744",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "15.03.05.05"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ]
  },
  "cve": "CVE-2024-2558",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2024-2558",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2024-14308",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2024-2558",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-2558",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-14308",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2558"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. The vulnerability is caused by the cmdinput parameter of the formexeCommand function in the /goform/execCommand file failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute on the system. Arbitrary code or lead to denial of service attacks",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-2558"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-2558",
        "trust": 1.6
      },
      {
        "db": "VULDB",
        "id": "257057",
        "trust": 1.0
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2558"
      }
    ]
  },
  "id": "VAR-202403-0744",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:31:37.531000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC18 formexeCommand function buffer overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/534891"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-2558"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.0,
        "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac18/formexecommand.md"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.257057"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?id.257057"
      },
      {
        "trust": 0.6,
        "url": "https://access.redhat.com/security/cve/cve-2024-25580"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2558"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2558"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "date": "2024-03-17T09:15:07.253000",
        "db": "NVD",
        "id": "CVE-2024-2558"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "date": "2024-05-17T02:38:18.947000",
        "db": "NVD",
        "id": "CVE-2024-2558"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 formexeCommand function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0274
Vulnerability from variot

An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request. plural Tenda The product contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC9, AC15 and AC18 are all wireless router products from Tenda. Security flaws exist in Tenda AC9, AC15, and AC18. The following products and versions are affected: Tenda AC9 V15.03.05.19(6318)_CN version; AC15 V15.03.05.19_CN version; AC18 V15.03.05.19(6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0274",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      }
    ]
  },
  "cve": "CVE-2018-18728",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18728",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-01887",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-129316",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18728",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18728",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18728",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-01887",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1355",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129316",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129316"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request. plural Tenda The product contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC9, AC15 and AC18 are all wireless router products from Tenda. Security flaws exist in Tenda AC9, AC15, and AC18. The following products and versions are affected: Tenda AC9 V15.03.05.19(6318)_CN version; AC15 V15.03.05.19_CN version; AC18 V15.03.05.19(6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18728"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129316"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18728",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129316",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129316"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "id": "VAR-201810-0274",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129316"
      }
    ],
    "trust": 1.4076761016666666
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:51:59.280000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-77",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129316"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/rce1.md"
      },
      {
        "trust": 1.4,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18728"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18728"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129316"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129316"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129316"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      },
      {
        "date": "2018-10-29T12:29:07.507000",
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129316"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      },
      {
        "date": "2024-11-21T03:56:28.030000",
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Command injection vulnerability in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "operating system commend injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      }
    ],
    "trust": 0.6
  }
}

var-202005-0458
Vulnerability from variot

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/setcfm funcpara1 parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202005-0458",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.06.42_multi"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      },
      {
        "model": "ac15 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac18 ) cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19(6318"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac6_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      }
    ]
  },
  "cve": "CVE-2020-13392",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-13392",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.1,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005746",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-31407",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-13392",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005746",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-13392",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-005746",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-31407",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202005-1142",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-13392",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13392"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/setcfm funcpara1 parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-13392"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13392"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-13392",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1142",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13392",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13392"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "id": "VAR-202005-0458",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      }
    ],
    "trust": 1.38075707625
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:16:28.744000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://tendacn.com/en"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13392-tenda-vulnerability/"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13392"
      },
      {
        "trust": 1.7,
        "url": "https://joel-malwarebenchmark.github.io"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13392"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/120.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13392"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13392"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-13392"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      },
      {
        "date": "2020-05-22T17:15:11.237000",
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "date": "2020-05-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-13392"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "date": "2020-05-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      },
      {
        "date": "2024-11-21T05:01:10.107000",
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Classic buffer overflow vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      }
    ],
    "trust": 0.6
  }
}

var-202211-1361
Vulnerability from variot

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function fromSetRouteStatic.

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1361",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44176"
      }
    ]
  },
  "cve": "CVE-2022-44176",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-44176",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-44176",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-3231",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3231"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44176"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function fromSetRouteStatic.",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44176"
      }
    ],
    "trust": 1.0
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-44176",
        "trust": 1.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3231",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3231"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44176"
      }
    ]
  },
  "id": "VAR-202211-1361",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.40125
  },
  "last_update_date": "2024-08-14T14:30:51.533000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44176"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/robinwang825/iot_vuln/tree/main/tenda/ac18/fromsetroutestatic"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-44176/"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3231"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44176"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3231"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44176"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3231"
      },
      {
        "date": "2022-11-21T18:15:23.223000",
        "db": "NVD",
        "id": "CVE-2022-44176"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3231"
      },
      {
        "date": "2022-11-28T13:47:48.517000",
        "db": "NVD",
        "id": "CVE-2022-44176"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3231"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 Security hole",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3231"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3231"
      }
    ],
    "trust": 0.6
  }
}

var-202209-1794
Vulnerability from variot

Tenda AC15 and AC18 routers V15.03.05.19 contain stack overflow vulnerabilities in the function setSmartPowerManagement with the request /goform/PowerSaveSet. Tenda of AC15 firmware and AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Both the Tenda AC15 and Tenda AC18 are products of the Chinese company Tenda. Tenda AC15 is a wireless router. Tenda AC18 is a router. The vulnerability stems from the fact that the parameter time of the setSmartPowerManagement method does not check the size of the input data when the method contains the request /goform/PowerSaveSet. Attackers can exploit the vulnerability to cause remote code execution or Denial of service

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202209-1794",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88197"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017555"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40864"
      }
    ]
  },
  "cve": "CVE-2022-40864",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-88197",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-40864",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-40864",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-40864",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-40864",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-88197",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202209-2392",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88197"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017555"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2392"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40864"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC15 and AC18 routers V15.03.05.19 contain stack overflow vulnerabilities in the function setSmartPowerManagement with the request /goform/PowerSaveSet. Tenda of AC15 firmware and AC18 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Both the Tenda AC15 and Tenda AC18 are products of the Chinese company Tenda. Tenda AC15 is a wireless router. Tenda AC18 is a router. The vulnerability stems from the fact that the parameter time of the setSmartPowerManagement method does not check the size of the input data when the method contains the request /goform/PowerSaveSet. Attackers can exploit the vulnerability to cause remote code execution or Denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-40864"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017555"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-88197"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-40864",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017555",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-88197",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2392",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88197"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017555"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2392"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40864"
      }
    ]
  },
  "id": "VAR-202209-1794",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88197"
      }
    ],
    "trust": 1.001633365
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88197"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:00:45.975000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC15 and AC18 setSmartPowerManagement stack overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/372536"
      },
      {
        "title": "Tenda AC15  and Tenda AC18 Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=208894"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88197"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2392"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017555"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40864"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.0,
        "url": "https://github.com/cpseek/router-vuls/blob/main/tenda/ac18/setsmartpowermanagement.md"
      },
      {
        "trust": 2.4,
        "url": "https://github.com/cpseek/router-vuls/blob/main/tenda/ac15/setsmartpowermanagement.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-40864"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-40864/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88197"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017555"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2392"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40864"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-88197"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017555"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2392"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-40864"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-17T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-88197"
      },
      {
        "date": "2023-10-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017555"
      },
      {
        "date": "2022-09-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-2392"
      },
      {
        "date": "2022-09-23T14:15:13.303000",
        "db": "NVD",
        "id": "CVE-2022-40864"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-88197"
      },
      {
        "date": "2023-10-13T08:42:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-017555"
      },
      {
        "date": "2022-09-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202209-2392"
      },
      {
        "date": "2022-09-23T20:25:59.923000",
        "db": "NVD",
        "id": "CVE-2022-40864"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2392"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC15\u00a0 firmware and \u00a0AC18\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-017555"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202209-2392"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0246
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "firewallEn" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0246",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      }
    ]
  },
  "cve": "CVE-2018-18709",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18709",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-09142",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129295",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18709",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18709",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18709",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-09142",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1340",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129295",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2018-18709",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18709"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18709"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18709"
      }
    ],
    "trust": 2.34
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18709",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129295",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18709",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18709"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "id": "VAR-201810-0246",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129295"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:30:16.915000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/tenda.md"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18709"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18709"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/119.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18709"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18709"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-04-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-18709"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      },
      {
        "date": "2018-10-29T12:29:05.727000",
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-04-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-18709"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "date": "2018-10-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      },
      {
        "date": "2024-11-21T03:56:25.177000",
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      }
    ],
    "trust": 0.6
  }
}

var-202403-0846
Vulnerability from variot

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda AC18 is a router made by the Chinese company Tenda. This vulnerability is caused by the password parameter of the R7WebsSecurityHandler function failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0846",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "15.03.05.05"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14310"
      }
    ]
  },
  "cve": "CVE-2024-2547",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2024-2547",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2024-14310",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2024-2547",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-2547",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-14310",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14310"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2547"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda AC18 is a router made by the Chinese company Tenda. This vulnerability is caused by the password parameter of the R7WebsSecurityHandler function failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-2547"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14310"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-2547",
        "trust": 1.6
      },
      {
        "db": "VULDB",
        "id": "257000",
        "trust": 1.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14310",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14310"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2547"
      }
    ]
  },
  "id": "VAR-202403-0846",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14310"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14310"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:26:06.578000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC18 R7WebsSecurityHandler function buffer overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/534901"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14310"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-2547"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://vuldb.com/?id.257000"
      },
      {
        "trust": 1.0,
        "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac18/r7webssecurityhandler.md"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.257000"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14310"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2547"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14310"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2547"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14310"
      },
      {
        "date": "2024-03-17T04:15:06.750000",
        "db": "NVD",
        "id": "CVE-2024-2547"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14310"
      },
      {
        "date": "2024-05-17T02:38:18.377000",
        "db": "NVD",
        "id": "CVE-2024-2547"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 R7WebsSecurityHandler function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14310"
      }
    ],
    "trust": 0.6
  }
}

cve-2023-38823
Vulnerability from cvelistv5
Published
2023-11-20 00:00
Modified
2024-08-02 17:54
Severity ?
Summary
Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:54:38.461Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/johnathanhuutri/CVE_report/blob/master/CVE-2023-38823/README.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-29T21:24:20.736046",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/johnathanhuutri/CVE_report/blob/master/CVE-2023-38823/README.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-38823",
    "datePublished": "2023-11-20T00:00:00",
    "dateReserved": "2023-07-25T00:00:00",
    "dateUpdated": "2024-08-02T17:54:38.461Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-30473
Vulnerability from cvelistv5
Published
2022-05-26 15:19
Modified
2024-08-03 06:48
Severity ?
Summary
Tenda AC Series Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function form_fast_setting_wifi_set
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:48:36.387Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC Series Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function form_fast_setting_wifi_set"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-26T15:19:49",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/2"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-30473",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC Series Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function form_fast_setting_wifi_set"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/2",
              "refsource": "MISC",
              "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/2"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-30473",
    "datePublished": "2022-05-26T15:19:49",
    "dateReserved": "2022-05-09T00:00:00",
    "dateUpdated": "2024-08-03T06:48:36.387Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-30476
Vulnerability from cvelistv5
Published
2022-05-26 15:25
Modified
2024-08-03 06:48
Severity ?
Summary
Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetFirewallCfg request.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:48:36.438Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/6"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetFirewallCfg request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-26T15:25:45",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/6"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-30476",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetFirewallCfg request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/6",
              "refsource": "MISC",
              "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/6"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-30476",
    "datePublished": "2022-05-26T15:25:45",
    "dateReserved": "2022-05-09T00:00:00",
    "dateUpdated": "2024-08-03T06:48:36.438Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-35201
Vulnerability from cvelistv5
Published
2022-08-19 14:25
Modified
2024-08-03 09:29
Severity ?
Summary
Tenda-AC18 V15.03.05.05 was discovered to contain a remote command execution (RCE) vulnerability.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:29:17.415Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://tenda-ac18.com"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tendacn.com/default.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://124.222.176.39/21f93b5e3b39b22b6df1e6a9c61ed70d54e8378bbeacd844efff921b9a1a8624/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda-AC18 V15.03.05.05 was discovered to contain a remote command execution (RCE) vulnerability."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-19T14:25:08",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://tenda-ac18.com"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tendacn.com/default.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://124.222.176.39/21f93b5e3b39b22b6df1e6a9c61ed70d54e8378bbeacd844efff921b9a1a8624/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-35201",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda-AC18 V15.03.05.05 was discovered to contain a remote command execution (RCE) vulnerability."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://tenda-ac18.com",
              "refsource": "MISC",
              "url": "http://tenda-ac18.com"
            },
            {
              "name": "https://www.tendacn.com/default.html",
              "refsource": "MISC",
              "url": "https://www.tendacn.com/default.html"
            },
            {
              "name": "http://124.222.176.39/21f93b5e3b39b22b6df1e6a9c61ed70d54e8378bbeacd844efff921b9a1a8624/index.html",
              "refsource": "MISC",
              "url": "http://124.222.176.39/21f93b5e3b39b22b6df1e6a9c61ed70d54e8378bbeacd844efff921b9a1a8624/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-35201",
    "datePublished": "2022-08-19T14:25:08",
    "dateReserved": "2022-07-04T00:00:00",
    "dateUpdated": "2024-08-03T09:29:17.415Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-18731
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceMac' parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.376Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-28T00:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18731",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md",
              "refsource": "MISC",
              "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18731",
    "datePublished": "2018-10-28T00:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.376Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-44175
Vulnerability from cvelistv5
Published
2022-11-21 00:00
Modified
2024-08-03 13:47
Severity ?
Summary
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetMacFilterCfg.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:05.648Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/RobinWang825/IoT_vuln/blob/main/Tenda/AC18/formSetMacFilterCfg/readme.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetMacFilterCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-21T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/RobinWang825/IoT_vuln/blob/main/Tenda/AC18/formSetMacFilterCfg/readme.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-44175",
    "datePublished": "2022-11-21T00:00:00",
    "dateReserved": "2022-10-30T00:00:00",
    "dateUpdated": "2024-08-03T13:47:05.648Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2017-16923
Vulnerability from cvelistv5
Published
2017-11-21 14:00
Modified
2024-09-17 03:14
Severity ?
Summary
Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the "sub_A6E8 usbeject_process_entry" function executes a system function with untrusted input.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:35:21.360Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the \"sub_A6E8 usbeject_process_entry\" function executes a system function with untrusted input."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-11-21T14:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-16923",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the \"sub_A6E8 usbeject_process_entry\" function executes a system function with untrusted input."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/Iolop/Poc/tree/master/Router/Tenda",
              "refsource": "MISC",
              "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-16923",
    "datePublished": "2017-11-21T14:00:00Z",
    "dateReserved": "2017-11-21T00:00:00Z",
    "dateUpdated": "2024-09-17T03:14:10.141Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-44183
Vulnerability from cvelistv5
Published
2022-11-21 00:00
Modified
2024-08-03 13:47
Severity ?
Summary
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetWifiGuestBasic.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:05.636Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC18/formSetWifiGuestBasic"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetWifiGuestBasic."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-21T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC18/formSetWifiGuestBasic"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-44183",
    "datePublished": "2022-11-21T00:00:00",
    "dateReserved": "2022-10-30T00:00:00",
    "dateUpdated": "2024-08-03T13:47:05.636Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-40854
Vulnerability from cvelistv5
Published
2022-09-23 14:17
Modified
2024-08-03 12:28
Severity ?
Summary
Tenda AC18 router contained a stack overflow vulnerability in /goform/fast_setting_wifi_set
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:28:42.909Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC18/form_fast_setting_wifi_set.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 router contained a stack overflow vulnerability in /goform/fast_setting_wifi_set"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-23T14:17:07",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC18/form_fast_setting_wifi_set.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-40854",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC18 router contained a stack overflow vulnerability in /goform/fast_setting_wifi_set"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC18/form_fast_setting_wifi_set.md",
              "refsource": "MISC",
              "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC18/form_fast_setting_wifi_set.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-40854",
    "datePublished": "2022-09-23T14:17:07",
    "dateReserved": "2022-09-19T00:00:00",
    "dateUpdated": "2024-08-03T12:28:42.909Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-18707
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "ssid" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.407Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-27T22:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18707",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md",
              "refsource": "MISC",
              "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18707",
    "datePublished": "2018-10-27T22:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.407Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-2546
Vulnerability from cvelistv5
Published
2024-03-17 01:31
Modified
2024-08-01 19:18
Summary
A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.13.07.09:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.13.07.09"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2546",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-16T21:06:00.663025Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-16T21:06:58.371Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:18:47.953Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-256999 | Tenda AC18 fromSetWirelessRepeat stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.256999"
          },
          {
            "name": "VDB-256999 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.256999"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/A18/fromSetWirelessRepeat_a.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.13.07.09"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_backup (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC18 15.13.07.09 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Hierbei betrifft es die Funktion fromSetWirelessRepeat. Mittels Manipulieren des Arguments wpapsk_crypto5g mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-17T01:31:04.350Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-256999 | Tenda AC18 fromSetWirelessRepeat stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.256999"
        },
        {
          "name": "VDB-256999 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.256999"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/A18/fromSetWirelessRepeat_a.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-15T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-15T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-16T08:00:43.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC18 fromSetWirelessRepeat stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2546",
    "datePublished": "2024-03-17T01:31:04.350Z",
    "dateReserved": "2024-03-15T20:04:21.580Z",
    "dateUpdated": "2024-08-01T19:18:47.953Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-18706
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.389Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-27T22:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18706",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md",
              "refsource": "MISC",
              "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18706",
    "datePublished": "2018-10-27T22:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.389Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-38310
Vulnerability from cvelistv5
Published
2022-09-07 18:41
Modified
2024-08-03 10:54
Severity ?
Summary
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetStaticRouteCfg.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:54:03.172Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/6"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetStaticRouteCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-07T18:41:03",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/6"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-38310",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetStaticRouteCfg."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/6",
              "refsource": "MISC",
              "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/6"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-38310",
    "datePublished": "2022-09-07T18:41:03",
    "dateReserved": "2022-08-15T00:00:00",
    "dateUpdated": "2024-08-03T10:54:03.172Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-24164
Vulnerability from cvelistv5
Published
2023-01-26 00:00
Modified
2024-08-02 10:49
Severity ?
Summary
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_000c2318.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:49:09.018Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC18/4/4.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_000c2318."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-26T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC18/4/4.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-24164",
    "datePublished": "2023-01-26T00:00:00",
    "dateReserved": "2023-01-23T00:00:00",
    "dateUpdated": "2024-08-02T10:49:09.018Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-18730
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'startIp' and 'endIp' parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.429Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-28T00:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18730",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md",
              "refsource": "MISC",
              "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18730",
    "datePublished": "2018-10-28T00:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.429Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-38312
Vulnerability from cvelistv5
Published
2022-09-07 18:41
Modified
2024-08-03 10:54
Severity ?
Summary
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetIpMacBind.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:54:03.314Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/3"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetIpMacBind."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-07T18:41:06",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/3"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-38312",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetIpMacBind."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/3",
              "refsource": "MISC",
              "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/3"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-38312",
    "datePublished": "2022-09-07T18:41:06",
    "dateReserved": "2022-08-15T00:00:00",
    "dateUpdated": "2024-08-03T10:54:03.314Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-2560
Vulnerability from cvelistv5
Published
2024-03-17 10:31
Modified
2024-08-05 20:02
Summary
A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.05"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2560",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-18T15:36:33.032587Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:02:13.797Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:18:48.253Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257059 | Tenda AC18 SysToolRestoreSet fromSysToolRestoreSet cross-site request forgery",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257059"
          },
          {
            "name": "VDB-257059 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257059"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromSysToolRestoreSet.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.05"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_backup (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC18 15.03.05.05 wurde eine problematische Schwachstelle entdeckt. Hierbei betrifft es die Funktion fromSysToolRestoreSet der Datei /goform/SysToolRestoreSet. Dank der Manipulation mit unbekannten Daten kann eine cross-site request forgery-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-352",
              "description": "CWE-352 Cross-Site Request Forgery",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-17T10:31:04.158Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257059 | Tenda AC18 SysToolRestoreSet fromSysToolRestoreSet cross-site request forgery",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257059"
        },
        {
          "name": "VDB-257059 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257059"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromSysToolRestoreSet.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-16T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-16T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-16T07:59:40.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC18 SysToolRestoreSet fromSysToolRestoreSet cross-site request forgery"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2560",
    "datePublished": "2024-03-17T10:31:04.158Z",
    "dateReserved": "2024-03-16T06:54:30.955Z",
    "dateUpdated": "2024-08-05T20:02:13.797Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-18729
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router's web server -- httpd. While processing the 'mac' parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.404Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-28T00:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18729",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md",
              "refsource": "MISC",
              "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18729",
    "datePublished": "2018-10-28T00:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.404Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-44177
Vulnerability from cvelistv5
Published
2022-11-21 00:00
Modified
2024-08-03 13:47
Severity ?
Summary
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formWifiWpsStart.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:05.554Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC18/formWifiWpsStart"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formWifiWpsStart."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-21T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC18/formWifiWpsStart"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-44177",
    "datePublished": "2022-11-21T00:00:00",
    "dateReserved": "2022-10-30T00:00:00",
    "dateUpdated": "2024-08-03T13:47:05.554Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-30477
Vulnerability from cvelistv5
Published
2022-05-26 15:26
Modified
2024-08-03 06:48
Severity ?
Summary
Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetClientState request.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:48:36.391Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/4"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetClientState request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-26T15:26:42",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/4"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-30477",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetClientState request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/4",
              "refsource": "MISC",
              "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/4"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-30477",
    "datePublished": "2022-05-26T15:26:42",
    "dateReserved": "2022-05-09T00:00:00",
    "dateUpdated": "2024-08-03T06:48:36.391Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-30472
Vulnerability from cvelistv5
Published
2022-05-26 15:21
Modified
2024-08-03 06:48
Severity ?
Summary
Tenda AC Seris Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function fromAddressNat
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:48:36.429Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/1"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC Seris Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function fromAddressNat"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-26T15:21:13",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/1"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-30472",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC Seris Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function fromAddressNat"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/1",
              "refsource": "MISC",
              "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/1"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-30472",
    "datePublished": "2022-05-26T15:21:13",
    "dateReserved": "2022-05-09T00:00:00",
    "dateUpdated": "2024-08-03T06:48:36.429Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-30474
Vulnerability from cvelistv5
Published
2022-05-26 15:23
Modified
2024-08-03 06:48
Severity ?
Summary
Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a heap overflow in the httpd module when handling /goform/saveParentControlInfo request.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:48:36.343Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/5"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a heap overflow in the httpd module when handling /goform/saveParentControlInfo request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-26T15:23:08",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/5"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-30474",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a heap overflow in the httpd module when handling /goform/saveParentControlInfo request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/5",
              "refsource": "MISC",
              "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/5"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-30474",
    "datePublished": "2022-05-26T15:23:08",
    "dateReserved": "2022-05-09T00:00:00",
    "dateUpdated": "2024-08-03T06:48:36.343Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-38309
Vulnerability from cvelistv5
Published
2022-09-07 18:41
Modified
2024-08-03 10:54
Severity ?
Summary
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:54:03.451Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/4"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-07T18:41:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/4"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-38309",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/4",
              "refsource": "MISC",
              "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/4"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-38309",
    "datePublished": "2022-09-07T18:41:01",
    "dateReserved": "2022-08-15T00:00:00",
    "dateUpdated": "2024-08-03T10:54:03.451Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-18709
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "firewallEn" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.371Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-27T22:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18709",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md",
              "refsource": "MISC",
              "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18709",
    "datePublished": "2018-10-27T22:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.371Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-2485
Vulnerability from cvelistv5
Published
2024-03-15 07:00
Modified
2024-08-02 19:23
Summary
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:11:53.709Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-256892 | Tenda AC18 SetSpeedWan formSetSpeedWan stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.256892"
          },
          {
            "name": "VDB-256892 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.256892"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/SetSpeedWan.md"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/setUsbUnload.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.05"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2485",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-02T19:22:53.972031Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:23:30.656Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.05"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC18 15.03.05.05 gefunden. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formSetSpeedWan der Datei /goform/SetSpeedWan. Durch das Beeinflussen des Arguments speed_dir mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-15T07:00:08.196Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-256892 | Tenda AC18 SetSpeedWan formSetSpeedWan stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.256892"
        },
        {
          "name": "VDB-256892 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.256892"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/SetSpeedWan.md"
        },
        {
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/setUsbUnload.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-15T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-15T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-15T01:47:29.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC18 SetSpeedWan formSetSpeedWan stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2485",
    "datePublished": "2024-03-15T07:00:08.196Z",
    "dateReserved": "2024-03-15T00:42:22.429Z",
    "dateUpdated": "2024-08-02T19:23:30.656Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-38314
Vulnerability from cvelistv5
Published
2022-09-07 18:40
Modified
2024-08-03 10:54
Severity ?
Summary
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the urls parameter at /goform/saveParentControlInfo.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:54:02.822Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/1"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the urls parameter at /goform/saveParentControlInfo."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-07T18:40:52",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/1"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-38314",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the urls parameter at /goform/saveParentControlInfo."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/1",
              "refsource": "MISC",
              "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/1"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-38314",
    "datePublished": "2022-09-07T18:40:52",
    "dateReserved": "2022-08-15T00:00:00",
    "dateUpdated": "2024-08-03T10:54:02.822Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-44178
Vulnerability from cvelistv5
Published
2022-11-21 00:00
Modified
2024-08-03 13:47
Severity ?
Summary
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow. via function formWifiWpsOOB.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:05.709Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC18/formWifiWpsOOB"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow. via function formWifiWpsOOB."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-21T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC18/formWifiWpsOOB"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-44178",
    "datePublished": "2022-11-21T00:00:00",
    "dateReserved": "2022-10-30T00:00:00",
    "dateUpdated": "2024-08-03T13:47:05.709Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2017-16936
Vulnerability from cvelistv5
Published
2017-11-24 07:00
Modified
2024-08-05 20:43
Severity ?
Summary
Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1&path= URI that uses directory traversal sequences after a /usb/ substring.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:43:59.320Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-11-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1\u0026path= URI that uses directory traversal sequences after a /usb/ substring."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-11-24T07:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-16936",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1\u0026path= URI that uses directory traversal sequences after a /usb/ substring."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/Iolop/Poc/tree/master/Router/Tenda",
              "refsource": "MISC",
              "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-16936",
    "datePublished": "2017-11-24T07:00:00",
    "dateReserved": "2017-11-24T00:00:00",
    "dateUpdated": "2024-08-05T20:43:59.320Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-30135
Vulnerability from cvelistv5
Published
2023-05-05 00:00
Modified
2024-08-02 14:21
Severity ?
Summary
Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName parameter in the setUsbUnload function.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:21:44.516Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC18/8/8.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName parameter in the setUsbUnload function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-05T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC18/8/8.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-30135",
    "datePublished": "2023-05-05T00:00:00",
    "dateReserved": "2023-04-07T00:00:00",
    "dateUpdated": "2024-08-02T14:21:44.516Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-44174
Vulnerability from cvelistv5
Published
2022-11-21 00:00
Modified
2024-08-03 13:47
Severity ?
Summary
Tenda AC18 V15.03.05.05 is vulnerable to Buffer Overflow via function formSetDeviceName.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:05.581Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/RobinWang825/IoT_vuln/blob/main/Tenda/AC18/formSetDeviceName_05/Tenda_AC18_V15.03.05.05_Vuln_devName.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.05 is vulnerable to Buffer Overflow via function formSetDeviceName."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-21T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/RobinWang825/IoT_vuln/blob/main/Tenda/AC18/formSetDeviceName_05/Tenda_AC18_V15.03.05.05_Vuln_devName.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-44174",
    "datePublished": "2022-11-21T00:00:00",
    "dateReserved": "2022-10-30T00:00:00",
    "dateUpdated": "2024-08-03T13:47:05.581Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-40861
Vulnerability from cvelistv5
Published
2022-09-23 14:37
Modified
2024-08-03 12:28
Severity ?
Summary
Tenda AC18 router V15.03.05.19 contains a stack overflow vulnerability in the formSetQosBand->FUN_0007db78 function with the request /goform/SetNetControlList/
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:28:42.685Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC18/formSetQosBand.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 router V15.03.05.19 contains a stack overflow vulnerability in the formSetQosBand-\u003eFUN_0007db78 function with the request /goform/SetNetControlList/"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-23T14:37:09",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC18/formSetQosBand.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-40861",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC18 router V15.03.05.19 contains a stack overflow vulnerability in the formSetQosBand-\u003eFUN_0007db78 function with the request /goform/SetNetControlList/"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC18/formSetQosBand.md",
              "refsource": "MISC",
              "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC18/formSetQosBand.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-40861",
    "datePublished": "2022-09-23T14:37:09",
    "dateReserved": "2022-09-19T00:00:00",
    "dateUpdated": "2024-08-03T12:28:42.685Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-43260
Vulnerability from cvelistv5
Published
2022-10-18 00:00
Modified
2024-08-03 13:26
Severity ?
Summary
Tenda AC18 V15.03.05.19(6318) was discovered to contain a stack overflow via the time parameter in the fromSetSysTime function.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:26:02.815Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://drive.google.com/file/d/1elSFijqHselDzRNuawGfcHD4uL4N8_mM/view?usp=sharing"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.19(6318) was discovered to contain a stack overflow via the time parameter in the fromSetSysTime function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-18T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://drive.google.com/file/d/1elSFijqHselDzRNuawGfcHD4uL4N8_mM/view?usp=sharing"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-43260",
    "datePublished": "2022-10-18T00:00:00",
    "dateReserved": "2022-10-17T00:00:00",
    "dateUpdated": "2024-08-03T13:26:02.815Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-2559
Vulnerability from cvelistv5
Published
2024-03-17 09:31
Modified
2024-08-01 19:18
Summary
A vulnerability classified as problematic has been found in Tenda AC18 15.03.05.05. Affected is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257058 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2559",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-18T18:45:25.675349Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-05T17:22:21.132Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:18:46.983Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257058 | Tenda AC18 SysToolReboot fromSysToolReboot cross-site request forgery",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257058"
          },
          {
            "name": "VDB-257058 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257058"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromSysToolReboot.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.05"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_backup (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as problematic has been found in Tenda AC18 15.03.05.05. Affected is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257058 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine problematische Schwachstelle in Tenda AC18 15.03.05.05 entdeckt. Dabei betrifft es die Funktion fromSysToolReboot der Datei /goform/SysToolReboot. Durch Beeinflussen mit unbekannten Daten kann eine cross-site request forgery-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-352",
              "description": "CWE-352 Cross-Site Request Forgery",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-17T09:31:04.514Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257058 | Tenda AC18 SysToolReboot fromSysToolReboot cross-site request forgery",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257058"
        },
        {
          "name": "VDB-257058 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257058"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromSysToolReboot.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-16T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-16T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-16T07:59:38.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC18 SysToolReboot fromSysToolReboot cross-site request forgery"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2559",
    "datePublished": "2024-03-17T09:31:04.514Z",
    "dateReserved": "2024-03-16T06:54:29.196Z",
    "dateUpdated": "2024-08-01T19:18:46.983Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-2487
Vulnerability from cvelistv5
Published
2024-03-15 08:31
Modified
2024-08-08 20:48
Summary
A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:11:53.605Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-256894 | Tenda AC18 SetOnlineDevName formSetDeviceName stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.256894"
          },
          {
            "name": "VDB-256894 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.256894"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formSetDeviceName_devName.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.05"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2487",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-08T20:48:11.123358Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-08T20:48:48.983Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.05"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC18 15.03.05.05 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Hierbei betrifft es die Funktion formSetDeviceName der Datei /goform/SetOnlineDevName. Dank der Manipulation des Arguments devName/mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-15T08:31:04.506Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-256894 | Tenda AC18 SetOnlineDevName formSetDeviceName stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.256894"
        },
        {
          "name": "VDB-256894 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.256894"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formSetDeviceName_devName.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-15T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-15T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-15T01:47:41.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC18 SetOnlineDevName formSetDeviceName stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2487",
    "datePublished": "2024-03-15T08:31:04.506Z",
    "dateReserved": "2024-03-15T00:42:38.900Z",
    "dateUpdated": "2024-08-08T20:48:48.983Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-24166
Vulnerability from cvelistv5
Published
2023-01-26 00:00
Modified
2024-08-02 10:49
Severity ?
Summary
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:49:09.147Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC18/2/2.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-26T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC18/2/2.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-24166",
    "datePublished": "2023-01-26T00:00:00",
    "dateReserved": "2023-01-23T00:00:00",
    "dateUpdated": "2024-08-02T10:49:09.147Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-10280
Vulnerability from cvelistv5
Published
2024-10-23 13:31
Modified
2024-10-23 17:41
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
Tenda AC7 Version: 20241022
Tenda AC8 Version: 20241022
Tenda AC9 Version: 20241022
Tenda AC10 Version: 20241022
Tenda AC10U Version: 20241022
Tenda AC15 Version: 20241022
Tenda AC18 Version: 20241022
Tenda AC500 Version: 20241022
Tenda AC1206 Version: 20241022
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac6_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac8_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.34.06"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac8_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.34.09"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.48.23"
              },
              {
                "status": "affected",
                "version": "16.03.48.19"
              },
              {
                "status": "affected",
                "version": "16.03.48.20"
              },
              {
                "status": "affected",
                "version": "16.03.48.13"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.42"
              },
              {
                "status": "affected",
                "version": "15.03.05.19\\(6318_\\)"
              },
              {
                "status": "affected",
                "version": "15.03.05.14"
              },
              {
                "status": "affected",
                "version": "15.03.2.13"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.05"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.19\\(6318\\)"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "2.0.1.9\\(1307\\)"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.16"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.14"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.48"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.49"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.44"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.18"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.19"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10280",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T17:28:19.760214Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T17:41:57.370Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC6",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC8",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC15",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC500",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC1206",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "minipython (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 bis 20241022 ausgemacht. Sie wurde als problematisch eingestuft. Davon betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.8,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-23T13:31:07.315Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281555 | Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281555"
        },
        {
          "name": "VDB-281555 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281555"
        },
        {
          "name": "Submit #426417 | Tenda AC8v4 V16.03.34.06 NULL Pointer Dereference",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.426417"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-23T08:07:55.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10280",
    "datePublished": "2024-10-23T13:31:07.315Z",
    "dateReserved": "2024-10-23T06:02:03.363Z",
    "dateUpdated": "2024-10-23T17:41:57.370Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-18727
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceList' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.390Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-28T00:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18727",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md",
              "refsource": "MISC",
              "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18727",
    "datePublished": "2018-10-28T00:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.390Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-38313
Vulnerability from cvelistv5
Published
2022-09-07 18:41
Modified
2024-08-03 10:54
Severity ?
Summary
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/saveParentControlInfo.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:54:03.579Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/saveParentControlInfo."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-07T18:41:07",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/2"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-38313",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/saveParentControlInfo."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/2",
              "refsource": "MISC",
              "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/2"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-38313",
    "datePublished": "2022-09-07T18:41:07",
    "dateReserved": "2022-08-15T00:00:00",
    "dateUpdated": "2024-08-03T10:54:03.579Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-24170
Vulnerability from cvelistv5
Published
2023-01-26 00:00
Modified
2024-08-02 10:49
Severity ?
Summary
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/fromSetWirelessRepeat.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:49:09.122Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC18/3/3.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/fromSetWirelessRepeat."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-26T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC18/3/3.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-24170",
    "datePublished": "2023-01-26T00:00:00",
    "dateReserved": "2023-01-23T00:00:00",
    "dateUpdated": "2024-08-02T10:49:09.122Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-2490
Vulnerability from cvelistv5
Published
2024-03-15 09:31
Modified
2024-08-01 19:18
Summary
A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.05"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2490",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-16T21:05:16.681190Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-16T21:05:39.904Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:18:46.467Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-256897 | Tenda AC18 openSchedWifi setSchedWifi stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.256897"
          },
          {
            "name": "VDB-256897 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.256897"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/Emilytutu/IoT-vulnerable/blob/main/Tenda/AC18/setSchedWifi_end.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.05"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC18 15.03.05.05 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion setSchedWifi der Datei /goform/openSchedWifi. Durch die Manipulation des Arguments schedStartTime/schedEndTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-15T09:31:04.121Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-256897 | Tenda AC18 openSchedWifi setSchedWifi stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.256897"
        },
        {
          "name": "VDB-256897 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.256897"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Emilytutu/IoT-vulnerable/blob/main/Tenda/AC18/setSchedWifi_end.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-15T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-15T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-15T01:48:09.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC18 openSchedWifi setSchedWifi stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2490",
    "datePublished": "2024-03-15T09:31:04.121Z",
    "dateReserved": "2024-03-15T00:43:05.939Z",
    "dateUpdated": "2024-08-01T19:18:46.467Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-18728
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
Summary
An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.397Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-28T00:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18728",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md",
              "refsource": "MISC",
              "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18728",
    "datePublished": "2018-10-28T00:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.397Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-38311
Vulnerability from cvelistv5
Published
2022-09-07 18:41
Modified
2024-08-03 10:54
Severity ?
Summary
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/PowerSaveSet.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:54:03.439Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/5"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/PowerSaveSet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-07T18:41:05",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/5"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-38311",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/PowerSaveSet."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/5",
              "refsource": "MISC",
              "url": "https://github.com/rickytriky/NWPU_Projct/tree/main/Tenda/AC18/5"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-38311",
    "datePublished": "2022-09-07T18:41:05",
    "dateReserved": "2022-08-15T00:00:00",
    "dateUpdated": "2024-08-03T10:54:03.439Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-18708
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromAddressNat" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.428Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-27T22:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18708",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md",
              "refsource": "MISC",
              "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18708",
    "datePublished": "2018-10-27T22:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.428Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-18732
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'ntpServer' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.422Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-28T00:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18732",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md",
              "refsource": "MISC",
              "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18732",
    "datePublished": "2018-10-28T00:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.422Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-44172
Vulnerability from cvelistv5
Published
2022-11-21 00:00
Modified
2024-08-03 13:47
Severity ?
Summary
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function R7WebsSecurityHandler.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:05.510Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/RobinWang825/IoT_vuln/blob/main/Tenda/AC18/R7WebsSecurityHandler/Tenda_AC18_V15.03.05.19_Vuln_password.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function R7WebsSecurityHandler."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-21T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/RobinWang825/IoT_vuln/blob/main/Tenda/AC18/R7WebsSecurityHandler/Tenda_AC18_V15.03.05.19_Vuln_password.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-44172",
    "datePublished": "2022-11-21T00:00:00",
    "dateReserved": "2022-10-30T00:00:00",
    "dateUpdated": "2024-08-03T13:47:05.510Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-24165
Vulnerability from cvelistv5
Published
2023-01-26 00:00
Modified
2024-08-02 10:49
Severity ?
Summary
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/initIpAddrInfo.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:49:09.016Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC18/7/7.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/initIpAddrInfo."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-26T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC18/7/7.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-24165",
    "datePublished": "2023-01-26T00:00:00",
    "dateReserved": "2023-01-23T00:00:00",
    "dateUpdated": "2024-08-02T10:49:09.016Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-24169
Vulnerability from cvelistv5
Published
2023-01-26 00:00
Modified
2024-08-02 10:49
Severity ?
Summary
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_0007343c.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:49:09.058Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC18/6/6.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_0007343c."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-26T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC18/6/6.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-24169",
    "datePublished": "2023-01-26T00:00:00",
    "dateReserved": "2023-01-23T00:00:00",
    "dateUpdated": "2024-08-02T10:49:09.058Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-2854
Vulnerability from cvelistv5
Published
2024-03-24 05:31
Modified
2024-08-12 18:05
Summary
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.155Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257778 | Tenda AC18 setsambacfg formSetSambaConf os command injection",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257778"
          },
          {
            "name": "VDB-257778 | CTI Indicators (IOB, IOC, TTP, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257778"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formSetSambaConf.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.05"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2854",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-12T15:18:49.243040Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-12T18:05:25.479Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.05"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AC18 15.03.05.05 entdeckt. Dabei betrifft es die Funktion formSetSambaConf der Datei /goform/setsambacfg. Durch Manipulation des Arguments usbName mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-24T05:31:04.168Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257778 | Tenda AC18 setsambacfg formSetSambaConf os command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257778"
        },
        {
          "name": "VDB-257778 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257778"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formSetSambaConf.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-23T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-23T06:52:29.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC18 setsambacfg formSetSambaConf os command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2854",
    "datePublished": "2024-03-24T05:31:04.168Z",
    "dateReserved": "2024-03-23T05:47:26.896Z",
    "dateUpdated": "2024-08-12T18:05:25.479Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-44180
Vulnerability from cvelistv5
Published
2022-11-21 00:00
Modified
2024-08-03 13:47
Severity ?
Summary
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function addWifiMacFilter.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:05.579Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC18/addWifiMacFilter"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function addWifiMacFilter."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-21T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC18/addWifiMacFilter"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-44180",
    "datePublished": "2022-11-21T00:00:00",
    "dateReserved": "2022-10-30T00:00:00",
    "dateUpdated": "2024-08-03T13:47:05.579Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-2489
Vulnerability from cvelistv5
Published
2024-03-15 09:00
Modified
2024-08-01 19:11
Summary
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.05"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2489",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-18T13:50:37.546517Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-19T17:15:31.415Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:11:53.495Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-256896 | Tenda AC18 SetNetControlList formSetQosBand stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.256896"
          },
          {
            "name": "VDB-256896 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.256896"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formSetQosBand.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.05"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AC18 15.03.05.05 entdeckt. Hiervon betroffen ist die Funktion formSetQosBand der Datei /goform/SetNetControlList. Mit der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-15T09:00:10.441Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-256896 | Tenda AC18 SetNetControlList formSetQosBand stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.256896"
        },
        {
          "name": "VDB-256896 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.256896"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formSetQosBand.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-15T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-15T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-15T01:48:03.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC18 SetNetControlList formSetQosBand stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2489",
    "datePublished": "2024-03-15T09:00:10.441Z",
    "dateReserved": "2024-03-15T00:43:00.217Z",
    "dateUpdated": "2024-08-01T19:11:53.495Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-44171
Vulnerability from cvelistv5
Published
2022-11-21 00:00
Modified
2024-08-03 13:47
Severity ?
Summary
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function form_fast_setting_wifi_set.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:05.722Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/RobinWang825/IoT_vuln/blob/main/Tenda/AC18/fast_setting_wifi_set/Tenda_AC18_V15.03.05.19_Vuln_timeZone.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function form_fast_setting_wifi_set."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-21T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/RobinWang825/IoT_vuln/blob/main/Tenda/AC18/fast_setting_wifi_set/Tenda_AC18_V15.03.05.19_Vuln_timeZone.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-44171",
    "datePublished": "2022-11-21T00:00:00",
    "dateReserved": "2022-10-30T00:00:00",
    "dateUpdated": "2024-08-03T13:47:05.722Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-30475
Vulnerability from cvelistv5
Published
2022-05-26 15:24
Modified
2024-08-03 06:48
Severity ?
Summary
Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/WifiExtraSet request.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:48:36.340Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/3"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/WifiExtraSet request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-26T15:24:38",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/3"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-30475",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/WifiExtraSet request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/3",
              "refsource": "MISC",
              "url": "https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/3"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-30475",
    "datePublished": "2022-05-26T15:24:38",
    "dateReserved": "2022-05-09T00:00:00",
    "dateUpdated": "2024-08-03T06:48:36.340Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-2547
Vulnerability from cvelistv5
Published
2024-03-17 03:31
Modified
2024-08-21 15:16
Summary
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:18:48.212Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257000 | Tenda AC18 R7WebsSecurityHandler stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257000"
          },
          {
            "name": "VDB-257000 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257000"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/R7WebsSecurityHandler.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.05"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2547",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-21T15:14:45.903222Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-21T15:16:52.674Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.05"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_backup (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC18 15.03.05.05 gefunden. Sie wurde als kritisch eingestuft. Davon betroffen ist die Funktion R7WebsSecurityHandler. Durch das Manipulieren des Arguments password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-17T03:31:03.829Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257000 | Tenda AC18 R7WebsSecurityHandler stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257000"
        },
        {
          "name": "VDB-257000 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257000"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/R7WebsSecurityHandler.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-15T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-15T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-15T21:09:51.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC18 R7WebsSecurityHandler stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2547",
    "datePublished": "2024-03-17T03:31:03.829Z",
    "dateReserved": "2024-03-15T20:04:28.272Z",
    "dateUpdated": "2024-08-21T15:16:52.674Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-2558
Vulnerability from cvelistv5
Published
2024-03-17 09:00
Modified
2024-08-02 17:32
Summary
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:18:47.827Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257057 | Tenda AC18 execCommand formexeCommand stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257057"
          },
          {
            "name": "VDB-257057 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257057"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formexeCommand.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.05"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2558",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-18T15:37:52.626613Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:32:11.576Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.05"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_backup (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC18 15.03.05.05 ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formexeCommand der Datei /goform/execCommand. Durch das Beeinflussen des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-17T09:00:07.516Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257057 | Tenda AC18 execCommand formexeCommand stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257057"
        },
        {
          "name": "VDB-257057 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257057"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formexeCommand.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-16T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-16T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-16T07:59:36.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC18 execCommand formexeCommand stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2558",
    "datePublished": "2024-03-17T09:00:07.516Z",
    "dateReserved": "2024-03-16T06:54:24.270Z",
    "dateUpdated": "2024-08-02T17:32:11.576Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-24167
Vulnerability from cvelistv5
Published
2023-01-26 00:00
Modified
2024-08-02 10:49
Severity ?
Summary
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/add_white_node.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:49:08.995Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC18/1/1.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/add_white_node."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-26T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC18/1/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-24167",
    "datePublished": "2023-01-26T00:00:00",
    "dateReserved": "2023-01-23T00:00:00",
    "dateUpdated": "2024-08-02T10:49:08.995Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-44176
Vulnerability from cvelistv5
Published
2022-11-21 00:00
Modified
2024-08-03 13:47
Severity ?
Summary
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function fromSetRouteStatic.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:05.701Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC18/fromSetRouteStatic"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function fromSetRouteStatic."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-21T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC18/fromSetRouteStatic"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-44176",
    "datePublished": "2022-11-21T00:00:00",
    "dateReserved": "2022-10-30T00:00:00",
    "dateUpdated": "2024-08-03T13:47:05.701Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-2486
Vulnerability from cvelistv5
Published
2024-03-15 08:00
Modified
2024-08-01 19:11
Summary
A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2486",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-15T19:13:56.363699Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-05T17:22:19.417Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:11:53.562Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-256893 | Tenda AC18 QuickIndex formQuickIndex stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.256893"
          },
          {
            "name": "VDB-256893 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.256893"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formQuickIndex.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.05"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda AC18 15.03.05.05 ausgemacht. Sie wurde als kritisch eingestuft. Dabei betrifft es die Funktion formQuickIndex der Datei /goform/QuickIndex. Durch Beeinflussen des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-15T08:00:06.524Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-256893 | Tenda AC18 QuickIndex formQuickIndex stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.256893"
        },
        {
          "name": "VDB-256893 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.256893"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formQuickIndex.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-15T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-15T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-15T01:47:36.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC18 QuickIndex formQuickIndex stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2486",
    "datePublished": "2024-03-15T08:00:06.524Z",
    "dateReserved": "2024-03-15T00:42:32.950Z",
    "dateUpdated": "2024-08-01T19:11:53.562Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-2488
Vulnerability from cvelistv5
Published
2024-03-15 09:00
Modified
2024-08-21 15:21
Summary
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:11:53.563Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-256895 | Tenda AC18 SetPptpServerCfg formSetPPTPServer stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.256895"
          },
          {
            "name": "VDB-256895 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.256895"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formSetPPTPServer.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.05"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2488",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-21T15:19:24.932211Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-21T15:21:16.841Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.05"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC18 15.03.05.05 ausgemacht. Sie wurde als kritisch eingestuft. Davon betroffen ist die Funktion formSetPPTPServer der Datei /goform/SetPptpServerCfg. Dank Manipulation des Arguments startIP mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-15T09:00:08.823Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-256895 | Tenda AC18 SetPptpServerCfg formSetPPTPServer stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.256895"
        },
        {
          "name": "VDB-256895 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.256895"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formSetPPTPServer.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-15T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-15T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-15T01:47:57.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC18 SetPptpServerCfg formSetPPTPServer stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2488",
    "datePublished": "2024-03-15T09:00:08.823Z",
    "dateReserved": "2024-03-15T00:42:54.142Z",
    "dateUpdated": "2024-08-21T15:21:16.841Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}