All the vulnerabilites related to Tenda - AC10
cve-2023-38935
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.522Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V4 V16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4.0 V16.03.10.13" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0 V15.03.06.42_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38935", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-15T20:06:05.688360Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-15T20:07:56.040Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38935", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-15T20:07:56.040Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18731
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.376Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18731", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18731", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.376Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-42163
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:03:45.766Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/fromNatStaticSetting/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/fromNatStaticSetting." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-17T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/fromNatStaticSetting/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-42163", "datePublished": "2022-10-17T00:00:00", "dateReserved": "2022-10-03T00:00:00", "dateUpdated": "2024-08-03T13:03:45.766Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18707
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.407Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-27T22:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18707", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18707", "datePublished": "2018-10-27T22:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.407Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-45482
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:21:16.501Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/l3m0nade/IOTvul/blob/master/assets/get_parentControl_list_Info_code.png" }, { "tags": [ "x_transferred" ], "url": "https://github.com/l3m0nade/IOTvul/blob/master/get_parentControl_list_Info.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-29T05:16:00.759908", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/l3m0nade/IOTvul/blob/master/assets/get_parentControl_list_Info_code.png" }, { "url": "https://github.com/l3m0nade/IOTvul/blob/master/get_parentControl_list_Info.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-45482", "datePublished": "2023-11-29T00:00:00", "dateReserved": "2023-10-09T00:00:00", "dateUpdated": "2024-08-02T20:21:16.501Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18706
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.389Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-27T22:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18706", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18706", "datePublished": "2018-10-27T22:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.389Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-45479
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:21:16.611Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/l3m0nade/IOTvul/blob/master/assets/sub_49E098_code.png" }, { "tags": [ "x_transferred" ], "url": "https://github.com/l3m0nade/IOTvul/blob/master/sub_49E098.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the list parameter in the function sub_49E098." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-29T05:15:54.752289", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/l3m0nade/IOTvul/blob/master/assets/sub_49E098_code.png" }, { "url": "https://github.com/l3m0nade/IOTvul/blob/master/sub_49E098.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-45479", "datePublished": "2023-11-29T00:00:00", "dateReserved": "2023-10-09T00:00:00", "dateUpdated": "2024-08-02T20:21:16.611Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18730
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.429Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18730", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18730", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.429Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-27019
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:01:32.273Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/8/8.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_458FBC function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/8/8.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-27019", "datePublished": "2023-04-07T00:00:00", "dateReserved": "2023-02-27T00:00:00", "dateUpdated": "2024-08-02T12:01:32.273Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-38936
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.689Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0 V15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.0.7(775)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38936", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-15T20:02:03.283677Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-15T20:05:36.911Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38936", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-15T20:05:36.911Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-42168
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:03:45.763Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/fromSetIpMacBind/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/fromSetIpMacBind." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-17T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/fromSetIpMacBind/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-42168", "datePublished": "2022-10-17T00:00:00", "dateReserved": "2022-10-03T00:00:00", "dateUpdated": "2024-08-03T13:03:45.763Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18729
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.404Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18729", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18729", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.404Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-27015
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:01:32.133Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/4/4.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_4A75C0 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/4/4.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-27015", "datePublished": "2023-04-07T00:00:00", "dateReserved": "2023-02-27T00:00:00", "dateUpdated": "2024-08-02T12:01:32.133Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-34566
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T16:10:07.090Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://hackmd.io/%400dayResearch/rk8hQf5rh" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-34566", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-06T21:13:12.853648Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-06T21:13:17.105Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://hackmd.io/%400dayResearch/rk8hQf5rh" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-34566", "datePublished": "2023-06-08T00:00:00", "dateReserved": "2023-06-07T00:00:00", "dateUpdated": "2025-01-06T21:13:17.105Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-34568
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T16:10:07.038Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://hackmd.io/%400dayResearch/ryR8IzMH2" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-34568", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-06T21:11:41.710065Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-06T21:11:49.677Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://hackmd.io/%400dayResearch/ryR8IzMH2" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-34568", "datePublished": "2023-06-08T00:00:00", "dateReserved": "2023-06-07T00:00:00", "dateUpdated": "2025-01-06T21:11:49.677Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-38937
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.643Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4 V16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0 V15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4.0 V16.03.10.13" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38937", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-17T14:37:17.298133Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-17T14:40:31.909Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38937", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-17T14:40:31.909Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-14559
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T09:29:51.666Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-04-25T19:44:46", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-14559", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-14559", "datePublished": "2019-04-25T19:44:46", "dateReserved": "2018-07-23T00:00:00", "dateUpdated": "2024-08-05T09:29:51.666Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-27021
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:01:32.355Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/9/9.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/9/9.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-27021", "datePublished": "2023-04-07T00:00:00", "dateReserved": "2023-02-27T00:00:00", "dateUpdated": "2024-08-02T12:01:32.355Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-42169
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:03:45.674Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/addWifiMacFilter/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/addWifiMacFilter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-17T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/addWifiMacFilter/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-42169", "datePublished": "2022-10-17T00:00:00", "dateReserved": "2022-10-03T00:00:00", "dateUpdated": "2024-08-03T13:03:45.674Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-46109
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:24:03.290Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/tree/main/Tenda/AC10/formSetClientState" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V15.03.06.23 is vulnerable to Buffer Overflow via function formSetClientState." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-16T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/tree/main/Tenda/AC10/formSetClientState" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-46109", "datePublished": "2022-12-16T00:00:00", "dateReserved": "2022-11-28T00:00:00", "dateUpdated": "2024-08-03T14:24:03.290Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-37716
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:23:26.317Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1202", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0BR_V1.2.0.20(408)" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1202", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.2.0.19_EN" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v.1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v3.0" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37716", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-30T15:41:48.422746Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-30T15:44:13.700Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-14T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-37716", "datePublished": "2023-07-14T00:00:00", "dateReserved": "2023-07-10T00:00:00", "dateUpdated": "2024-10-30T15:44:13.700Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-34570
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T16:10:07.256Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://hackmd.io/%400dayResearch/S1eI91_l2" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-34570", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-06T20:27:54.982563Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-06T20:28:49.677Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter devName at /goform/SetOnlineDevName." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://hackmd.io/%400dayResearch/S1eI91_l2" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-34570", "datePublished": "2023-06-08T00:00:00", "dateReserved": "2023-06-07T00:00:00", "dateUpdated": "2025-01-06T20:28:49.677Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-42170
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:03:45.824Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/formWifiWpsStart/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formWifiWpsStart." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-17T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/formWifiWpsStart/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-42170", "datePublished": "2022-10-17T00:00:00", "dateReserved": "2022-10-03T00:00:00", "dateUpdated": "2024-08-03T13:03:45.824Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18709
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.371Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-27T22:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18709", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18709", "datePublished": "2018-10-27T22:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.371Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-37717
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:23:27.232Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1202", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0BR_V1.2.0.20(408)" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1202", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.2.0.19_EN" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37717", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-30T15:36:28.731124Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-30T15:39:40.848Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-14T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-37717", "datePublished": "2023-07-14T00:00:00", "dateReserved": "2023-07-10T00:00:00", "dateUpdated": "2024-10-30T15:39:40.848Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-11248
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.284684 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.284684 | signature, permissions-required | |
https://vuldb.com/?submit.443204 | third-party-advisory | |
https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-formSetRebootTimer-stack-overflow-13d0448e619580bf8ab1df7cfb6c018b | exploit | |
https://www.tenda.com.cn/ | product |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.10.13" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-11248", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-15T19:29:37.983327Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-15T19:30:31.322Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC10", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.10.13" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "hand_king (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC10 16.03.10.13 gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formSetRebootTimer der Datei /goform/SetSysAutoRebbotCfg. Durch Manipulation des Arguments rebootTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-15T17:00:12.864Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-284684 | Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.284684" }, { "name": "VDB-284684 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.284684" }, { "name": "Submit #443204 | Tenda AC10v4 V16.03.10.13 Stack-based Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.443204" }, { "tags": [ "exploit" ], "url": "https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-formSetRebootTimer-stack-overflow-13d0448e619580bf8ab1df7cfb6c018b" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2024-11-15T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-11-15T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-11-15T08:40:15.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-11248", "datePublished": "2024-11-15T17:00:12.864Z", "dateReserved": "2024-11-15T07:35:05.406Z", "dateUpdated": "2024-11-15T19:30:31.322Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-27012
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:01:31.704Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/5/5.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/5/5.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-27012", "datePublished": "2023-04-07T00:00:00", "dateReserved": "2023-02-27T00:00:00", "dateUpdated": "2024-08-02T12:01:31.704Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-45481
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "us_ac10v4.0si_v16.03.10.13_cn" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-45481", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-26T15:23:47.894549Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-26T15:27:13.011Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T20:21:16.142Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/l3m0nade/IOTvul/blob/master/assets/setFirewallCfg_code.png" }, { "tags": [ "x_transferred" ], "url": "https://github.com/l3m0nade/IOTvul/blob/master/SetFirewallCfg.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-29T05:15:58.438842", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/l3m0nade/IOTvul/blob/master/assets/setFirewallCfg_code.png" }, { "url": "https://github.com/l3m0nade/IOTvul/blob/master/SetFirewallCfg.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-45481", "datePublished": "2023-11-29T00:00:00", "dateReserved": "2023-10-09T00:00:00", "dateUpdated": "2024-08-02T20:21:16.142Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-37710
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:23:26.299Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/tree/main/tenda/fromSetWirelessRepeat" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.47" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37710", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-12T14:33:52.670978Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-12T14:34:39.420Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-10T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/tree/main/tenda/fromSetWirelessRepeat" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-37710", "datePublished": "2023-07-10T00:00:00", "dateReserved": "2023-07-10T00:00:00", "dateUpdated": "2024-11-12T14:34:39.420Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-42164
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:03:45.618Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/formSetClientState/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetClientState." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-17T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/formSetClientState/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-42164", "datePublished": "2022-10-17T00:00:00", "dateReserved": "2022-10-03T00:00:00", "dateUpdated": "2024-08-03T13:03:45.618Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-34571
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T16:10:07.042Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://hackmd.io/%400dayResearch/S1GcUxzSn" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-34571", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-06T20:22:02.563371Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-06T20:22:07.202Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://hackmd.io/%400dayResearch/S1GcUxzSn" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-34571", "datePublished": "2023-06-08T00:00:00", "dateReserved": "2023-06-07T00:00:00", "dateUpdated": "2025-01-06T20:22:07.202Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-27020
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:01:32.162Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/1/1.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/1/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-27020", "datePublished": "2023-04-07T00:00:00", "dateReserved": "2023-02-27T00:00:00", "dateUpdated": "2024-08-02T12:01:32.162Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-27018
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:01:31.928Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/7/7.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45EC1C function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/7/7.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-27018", "datePublished": "2023-04-07T00:00:00", "dateReserved": "2023-02-27T00:00:00", "dateUpdated": "2024-08-02T12:01:31.928Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-37144
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:01:10.230Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DaDong-G/Vulnerability_info/blob/main/ac10_command_injection/Readme.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v15.03.06.26" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37144", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-13T14:33:43.982261Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-13T14:34:16.751Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DaDong-G/Vulnerability_info/blob/main/ac10_command_injection/Readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-37144", "datePublished": "2023-07-07T00:00:00", "dateReserved": "2023-06-28T00:00:00", "dateUpdated": "2024-11-13T14:34:16.751Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-10280
Vulnerability from cvelistv5
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.281555 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.281555 | signature, permissions-required | |
https://vuldb.com/?submit.426417 | third-party-advisory | |
https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md | exploit | |
https://www.tenda.com.cn/ | product |
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Tenda | AC6 |
Version: 20241022 |
||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.09" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.48.23" }, { "status": "affected", "version": "16.03.48.19" }, { "status": "affected", "version": "16.03.48.20" }, { "status": "affected", "version": "16.03.48.13" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.42" }, { "status": "affected", "version": "15.03.05.19\\(6318_\\)" }, { "status": "affected", "version": "15.03.05.14" }, { "status": "affected", "version": "15.03.2.13" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac18_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.05" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac18_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.19\\(6318\\)" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.1.9\\(1307\\)" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.16" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.14" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10u_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.48" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10u_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.49" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.19" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-10280", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-10-23T17:28:19.760214Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-23T17:41:57.370Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC6", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC9", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC10", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC10U", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC18", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC500", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC1206", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "minipython (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 bis 20241022 ausgemacht. Sie wurde als problematisch eingestuft. Davon betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.8, "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-23T13:31:07.315Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-281555 | Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.281555" }, { "name": "VDB-281555 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.281555" }, { "name": "Submit #426417 | Tenda AC8v4 V16.03.34.06 NULL Pointer Dereference", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.426417" }, { "tags": [ "exploit" ], "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2024-10-23T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-10-23T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-10-23T08:07:55.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-10280", "datePublished": "2024-10-23T13:31:07.315Z", "dateReserved": "2024-10-23T06:02:03.363Z", "dateUpdated": "2024-10-23T17:41:57.370Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-42171
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:03:45.525Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/saveParentControlInfo/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/saveParentControlInfo." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-17T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/saveParentControlInfo/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-42171", "datePublished": "2022-10-17T00:00:00", "dateReserved": "2022-10-03T00:00:00", "dateUpdated": "2024-08-03T13:03:45.525Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18727
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.390Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18727", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18727", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.390Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2581
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257081 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257081 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10/V16.03.10.13/fromSetRouteStatic.md | exploit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:18:48.191Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257081 | Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257081" }, { "name": "VDB-257081 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257081" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10/V16.03.10.13/fromSetRouteStatic.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.10.13" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2581", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-02T15:28:30.954053Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-02T15:29:50.674Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC10", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.10.13" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_backup (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda AC10 16.03.10.13 gefunden. Es geht hierbei um die Funktion fromSetRouteStatic der Datei /goform/SetStaticRouteCfg. Dank der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-18T03:00:06.600Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257081 | Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257081" }, { "name": "VDB-257081 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257081" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10/V16.03.10.13/fromSetRouteStatic.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-17T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-17T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-17T17:42:14.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2581", "datePublished": "2024-03-18T03:00:06.600Z", "dateReserved": "2024-03-17T16:37:02.849Z", "dateUpdated": "2024-08-02T15:29:50.674Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-42167
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:03:45.675Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/formSetFirewallCfg/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetFirewallCfg." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-17T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/formSetFirewallCfg/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-42167", "datePublished": "2022-10-17T00:00:00", "dateReserved": "2022-10-03T00:00:00", "dateUpdated": "2024-08-03T13:03:45.675Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-27014
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:01:32.300Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/10/10.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_46AC38 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/10/10.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-27014", "datePublished": "2023-04-07T00:00:00", "dateReserved": "2023-02-27T00:00:00", "dateUpdated": "2024-08-02T12:01:32.300Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-45484
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:21:16.319Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/l3m0nade/IOTvul/blob/master/assets/fromSetWifiGuestBasic_code.png" }, { "tags": [ "x_transferred" ], "url": "https://github.com/l3m0nade/IOTvul/blob/master/fromSetWifiGusetBasic.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGuestBasic." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-29T05:16:05.289983", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/l3m0nade/IOTvul/blob/master/assets/fromSetWifiGuestBasic_code.png" }, { "url": "https://github.com/l3m0nade/IOTvul/blob/master/fromSetWifiGusetBasic.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-45484", "datePublished": "2023-11-29T00:00:00", "dateReserved": "2023-10-09T00:00:00", "dateUpdated": "2024-08-02T20:21:16.319Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-27013
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:01:32.531Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/2/2.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the get_parentControl_list_Info function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/2/2.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-27013", "datePublished": "2023-04-07T00:00:00", "dateReserved": "2023-02-27T00:00:00", "dateUpdated": "2024-08-02T12:01:32.531Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-38933
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.649Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0 V15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.0.7(775)" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38933", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-17T13:48:33.206945Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-17T13:51:46.931Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38933", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-17T13:51:46.931Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18708
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.428Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-27T22:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18708", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18708", "datePublished": "2018-10-27T22:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.428Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18732
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.422Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18732", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18732", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.422Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-14558
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T09:29:51.678Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-07-21T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-30T17:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-14558", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-14558", "datePublished": "2018-10-30T18:00:00", "dateReserved": "2018-07-23T00:00:00", "dateUpdated": "2024-08-05T09:29:51.678Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-37711
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:23:26.314Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/tree/main/tenda/saveParentControlInfo" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.47" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37711", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-12T14:31:46.108590Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-12T14:33:31.886Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-10T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/tree/main/tenda/saveParentControlInfo" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-37711", "datePublished": "2023-07-10T00:00:00", "dateReserved": "2023-07-10T00:00:00", "dateUpdated": "2024-11-12T14:33:31.886Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-42165
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:03:45.717Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/formSetDeviceName/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetDeviceName." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-17T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/formSetDeviceName/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-42165", "datePublished": "2022-10-17T00:00:00", "dateReserved": "2022-10-03T00:00:00", "dateUpdated": "2024-08-03T13:03:45.717Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-11061
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.283807 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.283807 | signature, permissions-required | |
https://vuldb.com/?submit.440825 | third-party-advisory | |
https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-FUN_0044db3c-stack-overflow-13a0448e619580ae96fee2899545e159 | exploit | |
https://www.tenda.com.cn/ | product |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.10.13" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-11061", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-12T16:17:31.059883Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-12T18:27:42.336Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC10", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.10.13" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "hand_king (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "In Tenda AC10 16.03.10.13 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion FUN_0044db3c der Datei /goform/fast_setting_wifi_set. Durch das Manipulieren des Arguments timeZone mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-11T00:31:07.099Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-283807 | Tenda AC10 fast_setting_wifi_set FUN_0044db3c stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.283807" }, { "name": "VDB-283807 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.283807" }, { "name": "Submit #440825 | Tenda AC10v4 V16.03.10.13 Stack-based Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.440825" }, { "tags": [ "exploit" ], "url": "https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-FUN_0044db3c-stack-overflow-13a0448e619580ae96fee2899545e159" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2024-11-10T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-11-10T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-11-10T09:50:30.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC10 fast_setting_wifi_set FUN_0044db3c stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-11061", "datePublished": "2024-11-11T00:31:07.099Z", "dateReserved": "2024-11-10T08:45:18.006Z", "dateUpdated": "2024-11-12T18:27:42.336Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-14557
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T09:29:51.699Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-04-25T19:42:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-14557", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-14557", "datePublished": "2019-04-25T19:42:41", "dateReserved": "2018-07-23T00:00:00", "dateUpdated": "2024-08-05T09:29:51.699Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-32054
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/winmt/CVE/blob/main/Tenda%20AC10/README.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:32:55.906Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/winmt/CVE/blob/main/Tenda%20AC10/README.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 US_AC10V1.0RTL_V15.03.06.26_multi_TD01 was discovered to contain a remote code execution (RCE) vulnerability via the lanIp parameter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-07T17:08:33", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/winmt/CVE/blob/main/Tenda%20AC10/README.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-32054", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Tenda AC10 US_AC10V1.0RTL_V15.03.06.26_multi_TD01 was discovered to contain a remote code execution (RCE) vulnerability via the lanIp parameter." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/winmt/CVE/blob/main/Tenda%20AC10/README.md", "refsource": "MISC", "url": "https://github.com/winmt/CVE/blob/main/Tenda%20AC10/README.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-32054", "datePublished": "2022-07-07T17:08:33", "dateReserved": "2022-05-31T00:00:00", "dateUpdated": "2024-08-03T07:32:55.906Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-27016
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:01:32.281Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/3/3.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/3/3.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-27016", "datePublished": "2023-04-07T00:00:00", "dateReserved": "2023-02-27T00:00:00", "dateUpdated": "2024-08-02T12:01:32.281Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-38931
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.242Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4 V16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4.0 V16.03.10.13" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38931", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-17T13:52:20.173225Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-17T13:55:25.786Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38931", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-17T13:55:25.786Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-11056
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.283800 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.283800 | signature, permissions-required | |
https://vuldb.com/?submit.439358 | third-party-advisory | |
https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-stack-overflow-1380448e619580409bb1e1ac85f45570 | exploit | |
https://www.tenda.com.cn/ | product |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.10.13" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-11056", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-12T16:07:11.156602Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-12T20:11:15.388Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC10", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.10.13" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "hand_king (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda AC10 16.03.10.13 gefunden. Sie wurde als kritisch eingestuft. Es betrifft die Funktion FUN_0046AC38 der Datei /goform/WifiExtraSet. Dank der Manipulation des Arguments wpapsk_crypto mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-10T16:31:06.581Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-283800 | Tenda AC10 WifiExtraSet FUN_0046AC38 stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.283800" }, { "name": "VDB-283800 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.283800" }, { "name": "Submit #439358 | Tenda AC10v4 V16.03.10.13 Stack-based Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.439358" }, { "tags": [ "exploit" ], "url": "https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-stack-overflow-1380448e619580409bb1e1ac85f45570" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2024-11-09T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-11-09T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-11-09T21:19:49.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC10 WifiExtraSet FUN_0046AC38 stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-11056", "datePublished": "2024-11-10T16:31:06.581Z", "dateReserved": "2024-11-09T20:14:34.790Z", "dateUpdated": "2024-11-12T20:11:15.388Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-27017
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:01:32.272Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/6/6.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45DC58 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC10/6/6.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-27017", "datePublished": "2023-04-07T00:00:00", "dateReserved": "2023-02-27T00:00:00", "dateUpdated": "2024-08-02T12:01:32.272Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-34569
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T16:10:07.202Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://hackmd.io/%400dayResearch/HymuzffSh" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-34569", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-06T20:30:56.964048Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-06T20:31:49.124Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://hackmd.io/%400dayResearch/HymuzffSh" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-34569", "datePublished": "2023-06-08T00:00:00", "dateReserved": "2023-06-07T00:00:00", "dateUpdated": "2025-01-06T20:31:49.124Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-42320
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:16:51.059Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/aixiao0621/Tenda/blob/main/AC10/0.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:a:tenda:ac10v4:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10v4", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v.ac10v4.0si_v16.03.10.13_cn_tdc01" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-42320", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-09-25T17:20:52.150308Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-25T17:23:24.538Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Buffer Overflow vulnerability in Tenda AC10V4 v.US_AC10V4.0si_V16.03.10.13_cn_TDC01 allows a remote attacker to cause a denial of service via the mac parameter in the GetParentControlInfo function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-09-18T15:34:19.218743", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/aixiao0621/Tenda/blob/main/AC10/0.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-42320", "datePublished": "2023-09-18T00:00:00", "dateReserved": "2023-09-08T00:00:00", "dateUpdated": "2024-09-25T17:23:24.538Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-45483
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:21:16.686Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/l3m0nade/IOTvul/blob/master/assets/compare_parentcontrol_time_code.png" }, { "tags": [ "x_transferred" ], "url": "https://github.com/l3m0nade/IOTvul/blob/master/compare_parentcontrol_time.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the time parameter in the function compare_parentcontrol_time." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-29T05:16:04.020368", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/l3m0nade/IOTvul/blob/master/assets/compare_parentcontrol_time_code.png" }, { "url": "https://github.com/l3m0nade/IOTvul/blob/master/compare_parentcontrol_time.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-45483", "datePublished": "2023-11-29T00:00:00", "dateReserved": "2023-10-09T00:00:00", "dateUpdated": "2024-08-02T20:21:16.686Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2856
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257780 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257780 | signature, permissions-required | |
https://vuldb.com/?submit.299741 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10/V16.03.10.13/fromSetSysTime.md | exploit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.134Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257780 | Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257780" }, { "name": "VDB-257780 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257780" }, { "name": "Submit #299741 | Tenda AC10 AC10 v4.0 V16.03.10.13\u3001V16.03.10.20 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.299741" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10/V16.03.10.13/fromSetSysTime.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.10.13" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10_firmware:16.03.10.20:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.10.20" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2856", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-21T15:00:54.641317Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-21T15:03:56.980Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC10", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.10.13" }, { "status": "affected", "version": "16.03.10.20" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda AC10 16.03.10.13/16.03.10.20 entdeckt. Davon betroffen ist die Funktion fromSetSysTime der Datei /goform/SetSysTimeCfg. Mittels Manipulieren des Arguments timeZone mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-25T12:14:28.193Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257780 | Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257780" }, { "name": "VDB-257780 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257780" }, { "name": "Submit #299741 | Tenda AC10 AC10 v4.0 V16.03.10.13\u3001V16.03.10.20 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.299741" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10/V16.03.10.13/fromSetSysTime.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-23T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-23T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-23T06:52:42.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2856", "datePublished": "2024-03-24T06:31:04.241Z", "dateReserved": "2024-03-23T05:47:39.796Z", "dateUpdated": "2024-08-21T15:03:56.980Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-45480
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:21:16.612Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/l3m0nade/IOTvul/blob/master/assets/sub_47d878_code.png" }, { "tags": [ "x_transferred" ], "url": "https://github.com/l3m0nade/IOTvul/blob/master/sub_47D878.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the src parameter in the function sub_47D878." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-29T05:15:56.782169", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/l3m0nade/IOTvul/blob/master/assets/sub_47d878_code.png" }, { "url": "https://github.com/l3m0nade/IOTvul/blob/master/sub_47D878.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-45480", "datePublished": "2023-11-29T00:00:00", "dateReserved": "2023-10-09T00:00:00", "dateUpdated": "2024-08-02T20:21:16.612Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-34567
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T16:10:07.106Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://hackmd.io/%400dayResearch/H1xUqzfHh" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-34567", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-06T20:53:39.374875Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-06T20:54:33.073Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://hackmd.io/%400dayResearch/H1xUqzfHh" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-34567", "datePublished": "2023-06-08T00:00:00", "dateReserved": "2023-06-07T00:00:00", "dateUpdated": "2025-01-06T20:54:33.073Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-42166
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:03:45.718Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/formSetSpeedWan/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetSpeedWan." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-17T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/AC10/formSetSpeedWan/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-42166", "datePublished": "2022-10-17T00:00:00", "dateReserved": "2022-10-03T00:00:00", "dateUpdated": "2024-08-03T13:03:45.718Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-202210-1789
Vulnerability from variot
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formWifiWpsStart.
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202210-1789", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42170" } ] }, "cve": "CVE-2022-42170", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-42170", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-42170", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202210-1092", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1092" }, { "db": "NVD", "id": "CVE-2022-42170" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formWifiWpsStart.", "sources": [ { "db": "NVD", "id": "CVE-2022-42170" } ], "trust": 1.0 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-42170", "trust": 1.6 }, { "db": "CNNVD", "id": "CNNVD-202210-1092", "trust": 0.6 } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1092" }, { "db": "NVD", "id": "CVE-2022-42170" } ] }, "id": "VAR-202210-1789", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T14:02:15.131000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42170" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/ac10/formwifiwpsstart/readme.md" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-42170/" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1092" }, { "db": "NVD", "id": "CVE-2022-42170" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNNVD", "id": "CNNVD-202210-1092" }, { "db": "NVD", "id": "CVE-2022-42170" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1092" }, { "date": "2022-10-17T14:15:14.167000", "db": "NVD", "id": "CVE-2022-42170" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1092" }, { "date": "2022-10-19T15:06:33.337000", "db": "NVD", "id": "CVE-2022-42170" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1092" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1092" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1092" } ], "trust": 0.6 } }
var-201810-0276
Vulnerability from variot
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'startIp' and 'endIp' parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0276", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac15", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.05.19_cn" }, { "model": "ac7", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac9", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac9", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac7 v15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac9 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 v15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac15 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac18 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01885" }, { "db": "JVNDB", "id": "JVNDB-2018-011970" }, { "db": "CNNVD", "id": "CNNVD-201810-1357" }, { "db": "NVD", "id": "CVE-2018-18730" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tenda:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac15_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac18_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011970" } ] }, "cve": "CVE-2018-18730", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-18730", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2019-01885", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-129319", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-18730", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-18730", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-18730", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-01885", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201810-1357", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-129319", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01885" }, { "db": "VULHUB", "id": "VHN-129319" }, { "db": "JVNDB", "id": "JVNDB-2018-011970" }, { "db": "CNNVD", "id": "CNNVD-201810-1357" }, { "db": "NVD", "id": "CVE-2018-18730" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version", "sources": [ { "db": "NVD", "id": "CVE-2018-18730" }, { "db": "JVNDB", "id": "JVNDB-2018-011970" }, { "db": "CNVD", "id": "CNVD-2019-01885" }, { "db": "VULHUB", "id": "VHN-129319" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-18730", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2018-011970", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201810-1357", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2019-01885", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-129319", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01885" }, { "db": "VULHUB", "id": "VHN-129319" }, { "db": "JVNDB", "id": "JVNDB-2018-011970" }, { "db": "CNNVD", "id": "CNNVD-201810-1357" }, { "db": "NVD", "id": "CVE-2018-18730" } ] }, "id": "VAR-201810-0276", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2019-01885" }, { "db": "VULHUB", "id": "VHN-129319" } ], "trust": 1.4236169144444446 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01885" } ] }, "last_update_date": "2024-11-23T22:17:17.746000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011970" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-129319" }, { "db": "JVNDB", "id": "JVNDB-2018-011970" }, { "db": "NVD", "id": "CVE-2018-18730" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/zillr0/routers/blob/master/tenda/stack3.md" }, { "trust": 1.4, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18730" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18730" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01885" }, { "db": "VULHUB", "id": "VHN-129319" }, { "db": "JVNDB", "id": "JVNDB-2018-011970" }, { "db": "CNNVD", "id": "CNNVD-201810-1357" }, { "db": "NVD", "id": "CVE-2018-18730" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2019-01885" }, { "db": "VULHUB", "id": "VHN-129319" }, { "db": "JVNDB", "id": "JVNDB-2018-011970" }, { "db": "CNNVD", "id": "CNNVD-201810-1357" }, { "db": "NVD", "id": "CVE-2018-18730" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-01-18T00:00:00", "db": "CNVD", "id": "CNVD-2019-01885" }, { "date": "2018-10-29T00:00:00", "db": "VULHUB", "id": "VHN-129319" }, { "date": "2019-01-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011970" }, { "date": "2018-10-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1357" }, { "date": "2018-10-29T12:29:07.727000", "db": "NVD", "id": "CVE-2018-18730" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-01-18T00:00:00", "db": "CNVD", "id": "CNVD-2019-01885" }, { "date": "2018-12-14T00:00:00", "db": "VULHUB", "id": "VHN-129319" }, { "date": "2019-01-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011970" }, { "date": "2018-10-31T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1357" }, { "date": "2024-11-21T03:56:28.363000", "db": "NVD", "id": "CVE-2018-18730" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1357" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Product buffer error vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011970" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer overflow", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1357" } ], "trust": 0.6 } }
var-202311-2381
Vulnerability from variot
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the src parameter in the function sub_47D878. Tenda AC10 is a wireless router made by China Tenda Company.
Tenda AC10 has a buffer overflow vulnerability. This vulnerability is caused by the failure of the src parameter of the sub_47D878 function to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202311-2381", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac10", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v4.0v16.03.10.13" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06277" }, { "db": "NVD", "id": "CVE-2023-45480" } ] }, "cve": "CVE-2023-45480", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2024-06277", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-45480", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-45480", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2024-06277", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06277" }, { "db": "NVD", "id": "CVE-2023-45480" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the src parameter in the function sub_47D878. Tenda AC10 is a wireless router made by China Tenda Company. \n\r\n\r\nTenda AC10 has a buffer overflow vulnerability. This vulnerability is caused by the failure of the src parameter of the sub_47D878 function to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2023-45480" }, { "db": "CNVD", "id": "CNVD-2024-06277" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-45480", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2024-06277", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06277" }, { "db": "NVD", "id": "CVE-2023-45480" } ] }, "id": "VAR-202311-2381", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-06277" } ], "trust": 0.86649562 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06277" } ] }, "last_update_date": "2024-08-14T15:15:42.514000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda AC10 sub_47D878 function buffer overflow vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/521581" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06277" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-45480" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://github.com/l3m0nade/iotvul/blob/master/assets/sub_47d878_code.png" }, { "trust": 1.0, "url": "https://github.com/l3m0nade/iotvul/blob/master/sub_47d878.md" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06277" }, { "db": "NVD", "id": "CVE-2023-45480" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-06277" }, { "db": "NVD", "id": "CVE-2023-45480" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-25T00:00:00", "db": "CNVD", "id": "CNVD-2024-06277" }, { "date": "2023-11-29T06:15:46.620000", "db": "NVD", "id": "CVE-2023-45480" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-29T00:00:00", "db": "CNVD", "id": "CNVD-2024-06277" }, { "date": "2023-12-01T03:59:17.300000", "db": "NVD", "id": "CVE-2023-45480" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 sub_47D878 function buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-06277" } ], "trust": 0.6 } }
var-202304-0498
Vulnerability from variot
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0498", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13_cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.13 cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006850" }, { "db": "NVD", "id": "CVE-2023-27016" } ] }, "cve": "CVE-2023-27016", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-27016", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-27016", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-27016", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-27016", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202304-487", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006850" }, { "db": "CNNVD", "id": "CNNVD-202304-487" }, { "db": "NVD", "id": "CVE-2023-27016" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-27016" }, { "db": "JVNDB", "id": "JVNDB-2023-006850" }, { "db": "VULMON", "id": "CVE-2023-27016" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-27016", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006850", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-487", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-27016", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27016" }, { "db": "JVNDB", "id": "JVNDB-2023-006850" }, { "db": "CNNVD", "id": "CNNVD-202304-487" }, { "db": "NVD", "id": "CVE-2023-27016" } ] }, "id": "VAR-202304-0498", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T13:52:34.944000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006850" }, { "db": "NVD", "id": "CVE-2023-27016" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac10/3/3.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-27016" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-27016/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27016" }, { "db": "JVNDB", "id": "JVNDB-2023-006850" }, { "db": "CNNVD", "id": "CNNVD-202304-487" }, { "db": "NVD", "id": "CVE-2023-27016" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-27016" }, { "db": "JVNDB", "id": "JVNDB-2023-006850" }, { "db": "CNNVD", "id": "CNNVD-202304-487" }, { "db": "NVD", "id": "CVE-2023-27016" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27016" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006850" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-487" }, { "date": "2023-04-07T02:15:08.360000", "db": "NVD", "id": "CVE-2023-27016" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27016" }, { "date": "2023-11-16T07:00:00", "db": "JVNDB", "id": "JVNDB-2023-006850" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-487" }, { "date": "2023-04-13T18:03:50.213000", "db": "NVD", "id": "CVE-2023-27016" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-487" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006850" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-487" } ], "trust": 0.6 } }
var-202306-0634
Vulnerability from variot
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202306-0634", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "us_ac10v4.0si_v16.03.10.13_cn" } ], "sources": [ { "db": "NVD", "id": "CVE-2023-34569" } ] }, "cve": "CVE-2023-34569", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "id": "CVE-2023-34569", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-34569", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202306-620", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-620" }, { "db": "NVD", "id": "CVE-2023-34569" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList", "sources": [ { "db": "NVD", "id": "CVE-2023-34569" }, { "db": "VULMON", "id": "CVE-2023-34569" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-34569", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202306-620", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-34569", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-34569" }, { "db": "CNNVD", "id": "CNNVD-202306-620" }, { "db": "NVD", "id": "CVE-2023-34569" } ] }, "id": "VAR-202306-0634", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T14:36:46.987000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-34569" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://hackmd.io/%400dayresearch/hymuzffsh" }, { "trust": 0.7, "url": "https://hackmd.io/@0dayresearch/hymuzffsh" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-34569/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-34569" }, { "db": "CNNVD", "id": "CNNVD-202306-620" }, { "db": "NVD", "id": "CVE-2023-34569" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-34569" }, { "db": "CNNVD", "id": "CNNVD-202306-620" }, { "db": "NVD", "id": "CVE-2023-34569" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-08T00:00:00", "db": "VULMON", "id": "CVE-2023-34569" }, { "date": "2023-06-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202306-620" }, { "date": "2023-06-08T15:15:09.697000", "db": "NVD", "id": "CVE-2023-34569" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-08T00:00:00", "db": "VULMON", "id": "CVE-2023-34569" }, { "date": "2023-06-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202306-620" }, { "date": "2023-11-07T04:15:41.403000", "db": "NVD", "id": "CVE-2023-34569" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-620" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-620" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-620" } ], "trust": 0.6 } }
var-202203-1978
Vulnerability from variot
Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow in the setSmartPowerManagement function. Tenda AC10-1200 is a wireless router from China Tenda Company.
A buffer error vulnerability exists in Tenda AC10-1200, which arises from incorrect validation of data boundaries when performing operations on memory in the setSmartPowerManagement function. An attacker could exploit this vulnerability to crash the program
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202203-1978", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tendacn", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 15.03.06.23" }, { "model": "ac10-1200 v15.03.06.23 en", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38544" }, { "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "db": "NVD", "id": "CVE-2022-26243" } ] }, "cve": "CVE-2022-26243", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2022-26243", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2022-38544", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2022-26243", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-26243", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-26243", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2022-26243", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2022-38544", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202203-2038", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38544" }, { "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "db": "CNNVD", "id": "CNNVD-202203-2038" }, { "db": "NVD", "id": "CVE-2022-26243" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow in the setSmartPowerManagement function. Tenda AC10-1200 is a wireless router from China Tenda Company. \n\r\n\r\nA buffer error vulnerability exists in Tenda AC10-1200, which arises from incorrect validation of data boundaries when performing operations on memory in the setSmartPowerManagement function. An attacker could exploit this vulnerability to crash the program", "sources": [ { "db": "NVD", "id": "CVE-2022-26243" }, { "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "db": "CNVD", "id": "CNVD-2022-38544" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-26243", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2022-007166", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-38544", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202203-2038", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38544" }, { "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "db": "CNNVD", "id": "CNNVD-202203-2038" }, { "db": "NVD", "id": "CVE-2022-26243" } ] }, "id": "VAR-202203-1978", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-38544" } ], "trust": 1.23324781 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38544" } ] }, "last_update_date": "2024-11-23T22:47:28.529000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.0 }, { "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "db": "NVD", "id": "CVE-2022-26243" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://noob3xploiter.medium.com/hacking-the-tenda-ac10-1200-router-part-4-sscanf-buffer-overflow-75ae0e06abb6" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-26243" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-26243/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38544" }, { "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "db": "CNNVD", "id": "CNNVD-202203-2038" }, { "db": "NVD", "id": "CVE-2022-26243" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-38544" }, { "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "db": "CNNVD", "id": "CNNVD-202203-2038" }, { "db": "NVD", "id": "CVE-2022-26243" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2022-38544" }, { "date": "2023-07-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "date": "2022-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202203-2038" }, { "date": "2022-03-23T19:15:07.933000", "db": "NVD", "id": "CVE-2022-26243" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2022-38544" }, { "date": "2023-07-12T08:28:00", "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "date": "2022-04-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202203-2038" }, { "date": "2024-11-21T06:53:37.683000", "db": "NVD", "id": "CVE-2022-26243" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202203-2038" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda\u00a0 of \u00a0AC10\u00a0 Classic buffer overflow vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-007166" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202203-2038" } ], "trust": 0.6 } }
var-202403-0926
Vulnerability from variot
A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC10 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the timeZone parameter in the fromSetSysTime method of the /goform/SetSysTimeCfg page failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0926", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.20" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.20" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.13" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20301" }, { "db": "JVNDB", "id": "JVNDB-2024-003030" }, { "db": "NVD", "id": "CVE-2024-2856" } ] }, "cve": "CVE-2024-2856", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CVE-2024-2856", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.0, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-20301", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2024-2856", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2024-2856", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2024-2856", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-2856", "trust": 1.0, "value": "HIGH" }, { "author": "nvd@nist.gov", "id": "CVE-2024-2856", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2024-2856", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2024-20301", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20301" }, { "db": "JVNDB", "id": "JVNDB-2024-003030" }, { "db": "NVD", "id": "CVE-2024-2856" }, { "db": "NVD", "id": "CVE-2024-2856" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC10 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the timeZone parameter in the fromSetSysTime method of the /goform/SetSysTimeCfg page failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2024-2856" }, { "db": "JVNDB", "id": "JVNDB-2024-003030" }, { "db": "CNVD", "id": "CNVD-2024-20301" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-2856", "trust": 3.2 }, { "db": "VULDB", "id": "257780", "trust": 1.8 }, { "db": "JVNDB", "id": "JVNDB-2024-003030", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2024-20301", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20301" }, { "db": "JVNDB", "id": "JVNDB-2024-003030" }, { "db": "NVD", "id": "CVE-2024-2856" } ] }, "id": "VAR-202403-0926", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-20301" } ], "trust": 0.86649562 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20301" } ] }, "last_update_date": "2024-08-14T14:23:33.173000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda AC10 Buffer Overflow Vulnerability (CNVD-2024-20301)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/541151" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20301" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 }, { "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-003030" }, { "db": "NVD", "id": "CVE-2024-2856" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac10/v16.03.10.13/fromsetsystime.md" }, { "trust": 1.8, "url": "https://vuldb.com/?id.257780" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.257780" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.299741" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2856" }, { "trust": 0.6, "url": "https://github.com/ruanxingzhi/vul-report/tree/master/freeimage-r1909" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20301" }, { "db": "JVNDB", "id": "JVNDB-2024-003030" }, { "db": "NVD", "id": "CVE-2024-2856" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-20301" }, { "db": "JVNDB", "id": "JVNDB-2024-003030" }, { "db": "NVD", "id": "CVE-2024-2856" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-04-12T00:00:00", "db": "CNVD", "id": "CNVD-2024-20301" }, { "date": "2024-03-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2024-003030" }, { "date": "2024-03-24T07:15:08.140000", "db": "NVD", "id": "CVE-2024-2856" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-04-25T00:00:00", "db": "CNVD", "id": "CNVD-2024-20301" }, { "date": "2024-03-28T00:47:00", "db": "JVNDB", "id": "JVNDB-2024-003030" }, { "date": "2024-05-17T02:38:34.693000", "db": "NVD", "id": "CVE-2024-2856" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Stack-based buffer overflow vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-003030" } ], "trust": 0.8 } }
var-202203-1977
Vulnerability from variot
Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow via the urls parameter in the saveParentControlInfo function. Tenda of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10-1200 is a wireless router from China Tenda Company. An attacker could exploit this vulnerability to cause the program to crash
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202203-1977", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tendacn", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 15.03.06.23" }, { "model": "ac10-1200 v15.03.06.23 en", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38545" }, { "db": "JVNDB", "id": "JVNDB-2021-018998" }, { "db": "NVD", "id": "CVE-2021-38278" } ] }, "cve": "CVE-2021-38278", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-38278", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2022-38545", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-38278", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-38278", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-38278", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-38278", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2022-38545", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202203-2042", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38545" }, { "db": "JVNDB", "id": "JVNDB-2021-018998" }, { "db": "CNNVD", "id": "CNNVD-202203-2042" }, { "db": "NVD", "id": "CVE-2021-38278" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow via the urls parameter in the saveParentControlInfo function. Tenda of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10-1200 is a wireless router from China Tenda Company. An attacker could exploit this vulnerability to cause the program to crash", "sources": [ { "db": "NVD", "id": "CVE-2021-38278" }, { "db": "JVNDB", "id": "JVNDB-2021-018998" }, { "db": "CNVD", "id": "CNVD-2022-38545" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-38278", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2021-018998", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-38545", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202203-2042", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38545" }, { "db": "JVNDB", "id": "JVNDB-2021-018998" }, { "db": "CNNVD", "id": "CNNVD-202203-2042" }, { "db": "NVD", "id": "CVE-2021-38278" } ] }, "id": "VAR-202203-1977", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-38545" } ], "trust": 1.23324781 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38545" } ] }, "last_update_date": "2024-08-14T14:37:33.836000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-018998" }, { "db": "NVD", "id": "CVE-2021-38278" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://noob3xploiter.medium.com/hacking-the-tenda-ac10-1200-router-part-2-strcpy-buffer-overflow-92cd88e1d503" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-38278" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2021-38278/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38545" }, { "db": "JVNDB", "id": "JVNDB-2021-018998" }, { "db": "CNNVD", "id": "CNNVD-202203-2042" }, { "db": "NVD", "id": "CVE-2021-38278" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-38545" }, { "db": "JVNDB", "id": "JVNDB-2021-018998" }, { "db": "CNNVD", "id": "CNNVD-202203-2042" }, { "db": "NVD", "id": "CVE-2021-38278" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2022-38545" }, { "date": "2023-07-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-018998" }, { "date": "2022-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202203-2042" }, { "date": "2022-03-23T19:15:07.827000", "db": "NVD", "id": "CVE-2021-38278" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2022-38545" }, { "date": "2023-07-12T08:30:00", "db": "JVNDB", "id": "JVNDB-2021-018998" }, { "date": "2022-03-28T00:00:00", "db": "CNNVD", "id": "CNNVD-202203-2042" }, { "date": "2022-03-29T19:09:20.890000", "db": "NVD", "id": "CVE-2021-38278" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda\u00a0 of \u00a0AC10\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-018998" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202203-2042" } ], "trust": 0.6 } }
var-202411-0858
Vulnerability from variot
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC10 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202411-0858", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.13" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-013166" }, { "db": "NVD", "id": "CVE-2024-11248" } ] }, "cve": "CVE-2024-11248", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CVE-2024-11248", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.0, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "OTHER", "availabilityImpact": "Complete", "baseScore": 9.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "JVNDB-2024-013166", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2024-11248", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2024-013166", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-11248", "trust": 1.0, "value": "High" }, { "author": "nvd@nist.gov", "id": "CVE-2024-11248", "trust": 1.0, "value": "HIGH" }, { "author": "OTHER", "id": "JVNDB-2024-013166", "trust": 0.8, "value": "High" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-013166" }, { "db": "NVD", "id": "CVE-2024-11248" }, { "db": "NVD", "id": "CVE-2024-11248" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC10 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2024-11248" }, { "db": "JVNDB", "id": "JVNDB-2024-013166" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-11248", "trust": 2.6 }, { "db": "VULDB", "id": "284684", "trust": 1.0 }, { "db": "JVNDB", "id": "JVNDB-2024-013166", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-013166" }, { "db": "NVD", "id": "CVE-2024-11248" } ] }, "id": "VAR-202411-0858", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-11-22T23:12:13.775000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.0 }, { "problemtype": "CWE-121", "trust": 1.0 }, { "problemtype": "Buffer error (CWE-119) [ others ]", "trust": 0.8 }, { "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-013166" }, { "db": "NVD", "id": "CVE-2024-11248" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://tasty-foxtrot-3a8.notion.site/tenda-ac10v4-formsetreboottimer-stack-overflow-13d0448e619580bf8ab1df7cfb6c018b" }, { "trust": 1.8, "url": "https://vuldb.com/?submit.443204" }, { "trust": 1.8, "url": "https://www.tenda.com.cn/" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.284684" }, { "trust": 1.0, "url": "https://vuldb.com/?id.284684" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-11248" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-013166" }, { "db": "NVD", "id": "CVE-2024-11248" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2024-013166" }, { "db": "NVD", "id": "CVE-2024-11248" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-11-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2024-013166" }, { "date": "2024-11-15T17:15:19.580000", "db": "NVD", "id": "CVE-2024-11248" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-11-21T01:42:00", "db": "JVNDB", "id": "JVNDB-2024-013166" }, { "date": "2024-11-19T21:51:57.467000", "db": "NVD", "id": "CVE-2024-11248" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Buffer error vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-013166" } ], "trust": 0.8 } }
var-201807-1285
Vulnerability from variot
Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI. Tenda AC7 , AC9 ,and AC10 Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7, AC9 and AC10 are all wireless router products from Tenda. A buffer overflow vulnerability exists in TendaAC715.03.06.44_CN and previous versions, AC915.03.05.19 (6318)_CN and previous versions, and AC1015.03.06.23_CN and earlier. An attacker could exploit the vulnerability with a longer \342\200\230limitSpeed\342\200\231 or \342\200\230limitSpeedup\342\200\231 parameter to cause a denial of service
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201807-1285", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac18", "scope": "lte", "trust": 1.0, "vendor": "tendacn", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac7", "scope": "lte", "trust": 1.0, "vendor": "tendacn", "version": "15.03.06.44_cn" }, { "model": "ac10", "scope": "lte", "trust": 1.0, "vendor": "tendacn", "version": "15.03.06.23_cn" }, { "model": "ac9", "scope": "lte", "trust": 1.0, "vendor": "tendacn", "version": "v15.03.05.19\\(6318\\)_cn" }, { "model": "ac15", "scope": "lte", "trust": 1.0, "vendor": "tendacn", "version": "15.03.05.19_cn" }, { "model": "ac10", "scope": "lte", "trust": 0.8, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac15", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac18", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": "lte", "trust": 0.8, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac9", "scope": "lte", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac7 \u003c=15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 \u003c=15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac9 \u003c=15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": "eq", "trust": 0.6, "vendor": "tendacn", "version": "15.03.06.44_cn" }, { "model": "ac10", "scope": "eq", "trust": 0.6, "vendor": "tendacn", "version": "15.03.06.23_cn" }, { "model": "ac9", "scope": "eq", "trust": 0.6, "vendor": "tendacn", "version": "v15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 0.6, "vendor": "tendacn", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac15", "scope": "eq", "trust": 0.6, "vendor": "tendacn", "version": "15.03.05.19_cn" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-14983" }, { "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "db": "CNNVD", "id": "CNNVD-201807-1668" }, { "db": "NVD", "id": "CVE-2018-14492" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tendacn:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac15_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac18_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-008461" } ] }, "cve": "CVE-2018-14492", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-14492", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2018-14983", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-124657", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-14492", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-14492", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-14492", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2018-14983", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201807-1668", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-124657", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-14983" }, { "db": "VULHUB", "id": "VHN-124657" }, { "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "db": "CNNVD", "id": "CNNVD-201807-1668" }, { "db": "NVD", "id": "CVE-2018-14492" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI. Tenda AC7 , AC9 ,and AC10 Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7, AC9 and AC10 are all wireless router products from Tenda. A buffer overflow vulnerability exists in TendaAC715.03.06.44_CN and previous versions, AC915.03.05.19 (6318)_CN and previous versions, and AC1015.03.06.23_CN and earlier. An attacker could exploit the vulnerability with a longer \\342\\200\\230limitSpeed\\342\\200\\231 or \\342\\200\\230limitSpeedup\\342\\200\\231 parameter to cause a denial of service", "sources": [ { "db": "NVD", "id": "CVE-2018-14492" }, { "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "db": "CNVD", "id": "CNVD-2018-14983" }, { "db": "VULHUB", "id": "VHN-124657" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-14492", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2018-008461", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201807-1668", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2018-14983", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-124657", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-14983" }, { "db": "VULHUB", "id": "VHN-124657" }, { "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "db": "CNNVD", "id": "CNNVD-201807-1668" }, { "db": "NVD", "id": "CVE-2018-14492" } ] }, "id": "VAR-201807-1285", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2018-14983" }, { "db": "VULHUB", "id": "VHN-124657" } ], "trust": 1.3446503185714285 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-14983" } ] }, "last_update_date": "2024-11-23T22:52:01.968000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-008461" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.1 }, { "problemtype": "CWE-119", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-124657" }, { "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "db": "NVD", "id": "CVE-2018-14492" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://github.com/zillr0/routers/blob/master/tendaoob1.md" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14492" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14492" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-14983" }, { "db": "VULHUB", "id": "VHN-124657" }, { "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "db": "CNNVD", "id": "CNNVD-201807-1668" }, { "db": "NVD", "id": "CVE-2018-14492" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2018-14983" }, { "db": "VULHUB", "id": "VHN-124657" }, { "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "db": "CNNVD", "id": "CNNVD-201807-1668" }, { "db": "NVD", "id": "CVE-2018-14492" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-08-10T00:00:00", "db": "CNVD", "id": "CNVD-2018-14983" }, { "date": "2018-07-21T00:00:00", "db": "VULHUB", "id": "VHN-124657" }, { "date": "2018-10-18T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "date": "2018-07-21T00:00:00", "db": "CNNVD", "id": "CNNVD-201807-1668" }, { "date": "2018-07-21T12:29:00.333000", "db": "NVD", "id": "CVE-2018-14492" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-08-10T00:00:00", "db": "CNVD", "id": "CNVD-2018-14983" }, { "date": "2020-08-24T00:00:00", "db": "VULHUB", "id": "VHN-124657" }, { "date": "2018-10-18T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "date": "2020-08-25T00:00:00", "db": "CNNVD", "id": "CNNVD-201807-1668" }, { "date": "2024-11-21T03:49:10.740000", "db": "NVD", "id": "CVE-2018-14492" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201807-1668" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Product buffer error vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-008461" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201807-1668" } ], "trust": 0.6 } }
var-201810-0273
Vulnerability from variot
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceList' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (covering the return value of a function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0273", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac15", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19_cn" }, { "model": "ac9", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac7", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac10", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac15", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac18", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7 v15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac9 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 v15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac15 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac18 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01888" }, { "db": "JVNDB", "id": "JVNDB-2018-011964" }, { "db": "CNNVD", "id": "CNNVD-201810-1354" }, { "db": "NVD", "id": "CVE-2018-18727" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tenda:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac15_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac18_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011964" } ] }, "cve": "CVE-2018-18727", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-18727", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2019-01888", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-129315", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-18727", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-18727", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-18727", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-01888", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201810-1354", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-129315", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01888" }, { "db": "VULHUB", "id": "VHN-129315" }, { "db": "JVNDB", "id": "JVNDB-2018-011964" }, { "db": "CNNVD", "id": "CNNVD-201810-1354" }, { "db": "NVD", "id": "CVE-2018-18727" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (covering the return value of a function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version", "sources": [ { "db": "NVD", "id": "CVE-2018-18727" }, { "db": "JVNDB", "id": "JVNDB-2018-011964" }, { "db": "CNVD", "id": "CNVD-2019-01888" }, { "db": "VULHUB", "id": "VHN-129315" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-18727", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2018-011964", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201810-1354", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2019-01888", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-129315", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01888" }, { "db": "VULHUB", "id": "VHN-129315" }, { "db": "JVNDB", "id": "JVNDB-2018-011964" }, { "db": "CNNVD", "id": "CNNVD-201810-1354" }, { "db": "NVD", "id": "CVE-2018-18727" } ] }, "id": "VAR-201810-0273", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2019-01888" }, { "db": "VULHUB", "id": "VHN-129315" } ], "trust": 1.4236169144444446 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01888" } ] }, "last_update_date": "2024-11-23T22:45:10.729000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011964" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-129315" }, { "db": "JVNDB", "id": "JVNDB-2018-011964" }, { "db": "NVD", "id": "CVE-2018-18727" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/zillr0/routers/blob/master/tenda/stack1.md" }, { "trust": 1.4, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18727" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18727" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01888" }, { "db": "VULHUB", "id": "VHN-129315" }, { "db": "JVNDB", "id": "JVNDB-2018-011964" }, { "db": "CNNVD", "id": "CNNVD-201810-1354" }, { "db": "NVD", "id": "CVE-2018-18727" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2019-01888" }, { "db": "VULHUB", "id": "VHN-129315" }, { "db": "JVNDB", "id": "JVNDB-2018-011964" }, { "db": "CNNVD", "id": "CNNVD-201810-1354" }, { "db": "NVD", "id": "CVE-2018-18727" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-01-18T00:00:00", "db": "CNVD", "id": "CNVD-2019-01888" }, { "date": "2018-10-29T00:00:00", "db": "VULHUB", "id": "VHN-129315" }, { "date": "2019-01-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011964" }, { "date": "2018-10-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1354" }, { "date": "2018-10-29T12:29:07.400000", "db": "NVD", "id": "CVE-2018-18727" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-01-18T00:00:00", "db": "CNVD", "id": "CNVD-2019-01888" }, { "date": "2018-12-14T00:00:00", "db": "VULHUB", "id": "VHN-129315" }, { "date": "2019-01-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011964" }, { "date": "2018-10-31T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1354" }, { "date": "2024-11-21T03:56:27.863000", "db": "NVD", "id": "CVE-2018-18727" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1354" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Product buffer error vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011964" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer overflow", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1354" } ], "trust": 0.6 } }
var-202307-0808
Vulnerability from variot
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function. Shenzhen Tenda Technology Co.,Ltd. of AC10 firmware and ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202307-0808", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.47" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac1206", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019245" }, { "db": "NVD", "id": "CVE-2023-37711" } ] }, "cve": "CVE-2023-37711", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-37711", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-37711", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-37711", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-37711", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202307-529", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019245" }, { "db": "CNNVD", "id": "CNNVD-202307-529" }, { "db": "NVD", "id": "CVE-2023-37711" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function. Shenzhen Tenda Technology Co.,Ltd. of AC10 firmware and ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-37711" }, { "db": "JVNDB", "id": "JVNDB-2023-019245" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-37711", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2023-019245", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202307-529", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019245" }, { "db": "CNNVD", "id": "CNNVD-202307-529" }, { "db": "NVD", "id": "CVE-2023-37711" } ] }, "id": "VAR-202307-0808", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.36157598 }, "last_update_date": "2024-08-14T15:26:32.795000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Tenda AC1206 Buffer error vulnerability fix", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=246054" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-529" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019245" }, { "db": "NVD", "id": "CVE-2023-37711" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/firmrec/iot-vulns/tree/main/tenda/saveparentcontrolinfo" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37711" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-37711/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019245" }, { "db": "CNNVD", "id": "CNNVD-202307-529" }, { "db": "NVD", "id": "CVE-2023-37711" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-019245" }, { "db": "CNNVD", "id": "CNNVD-202307-529" }, { "db": "NVD", "id": "CVE-2023-37711" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-019245" }, { "date": "2023-07-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-529" }, { "date": "2023-07-10T17:15:09.837000", "db": "NVD", "id": "CVE-2023-37711" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-12T08:04:00", "db": "JVNDB", "id": "JVNDB-2023-019245" }, { "date": "2023-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-529" }, { "date": "2023-07-13T19:47:18.553000", "db": "NVD", "id": "CVE-2023-37711" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-529" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 firmware and \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019245" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-529" } ], "trust": 0.6 } }
var-202304-0619
Vulnerability from variot
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the get_parentControl_list_Info function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0619", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13_cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.13 cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006853" }, { "db": "NVD", "id": "CVE-2023-27013" } ] }, "cve": "CVE-2023-27013", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-27013", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-27013", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-27013", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-27013", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202304-489", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006853" }, { "db": "CNNVD", "id": "CNNVD-202304-489" }, { "db": "NVD", "id": "CVE-2023-27013" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the get_parentControl_list_Info function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-27013" }, { "db": "JVNDB", "id": "JVNDB-2023-006853" }, { "db": "VULMON", "id": "CVE-2023-27013" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-27013", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006853", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-489", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-27013", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27013" }, { "db": "JVNDB", "id": "JVNDB-2023-006853" }, { "db": "CNNVD", "id": "CNNVD-202304-489" }, { "db": "NVD", "id": "CVE-2023-27013" } ] }, "id": "VAR-202304-0619", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T15:21:11.853000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006853" }, { "db": "NVD", "id": "CVE-2023-27013" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac10/2/2.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-27013" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-27013/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27013" }, { "db": "JVNDB", "id": "JVNDB-2023-006853" }, { "db": "CNNVD", "id": "CNNVD-202304-489" }, { "db": "NVD", "id": "CVE-2023-27013" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-27013" }, { "db": "JVNDB", "id": "JVNDB-2023-006853" }, { "db": "CNNVD", "id": "CNNVD-202304-489" }, { "db": "NVD", "id": "CVE-2023-27013" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27013" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006853" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-489" }, { "date": "2023-04-07T02:15:08.250000", "db": "NVD", "id": "CVE-2023-27013" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27013" }, { "date": "2023-11-16T07:03:00", "db": "JVNDB", "id": "JVNDB-2023-006853" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-489" }, { "date": "2023-04-13T18:03:42.623000", "db": "NVD", "id": "CVE-2023-27013" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-489" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006853" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-489" } ], "trust": 0.6 } }
var-202210-1110
Vulnerability from variot
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetDeviceName.
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202210-1110", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42165" } ] }, "cve": "CVE-2022-42165", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-42165", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-42165", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202210-1065", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1065" }, { "db": "NVD", "id": "CVE-2022-42165" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetDeviceName.", "sources": [ { "db": "NVD", "id": "CVE-2022-42165" } ], "trust": 1.0 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-42165", "trust": 1.6 }, { "db": "CNNVD", "id": "CNNVD-202210-1065", "trust": 0.6 } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1065" }, { "db": "NVD", "id": "CVE-2022-42165" } ] }, "id": "VAR-202210-1110", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T14:10:31.420000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42165" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/ac10/formsetdevicename/readme.md" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-42165/" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1065" }, { "db": "NVD", "id": "CVE-2022-42165" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNNVD", "id": "CNNVD-202210-1065" }, { "db": "NVD", "id": "CVE-2022-42165" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1065" }, { "date": "2022-10-17T13:15:10.797000", "db": "NVD", "id": "CVE-2022-42165" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1065" }, { "date": "2022-10-19T15:07:55.720000", "db": "NVD", "id": "CVE-2022-42165" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1065" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1065" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1065" } ], "trust": 0.6 } }
var-202308-3714
Vulnerability from variot
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3714", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.42_multi" }, { "model": "fh1205", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.0.7\\(775\\)" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.44" }, { "model": "ac6", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "f1203", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.1.6" }, { "model": "fh1203", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.1.6" }, { "model": "ac1206", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "fh1203", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac6", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "fh1205", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "f1203", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "db": "NVD", "id": "CVE-2023-38936" } ] }, "cve": "CVE-2023-38936", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-38936", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-38936", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-38936", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-38936", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "db": "NVD", "id": "CVE-2023-38936" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-38936" }, { "db": "JVNDB", "id": "JVNDB-2023-021659" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-38936", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-021659", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "db": "NVD", "id": "CVE-2023-38936" } ] }, "id": "VAR-202308-3714", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3288697725 }, "last_update_date": "2024-08-14T15:36:47.021000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "db": "NVD", "id": "CVE-2023-38936" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetspeedwan/readme.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38936" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "db": "NVD", "id": "CVE-2023-38936" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "db": "NVD", "id": "CVE-2023-38936" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "date": "2023-08-07T19:15:11.343000", "db": "NVD", "id": "CVE-2023-38936" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T07:51:00", "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "date": "2023-08-10T18:20:51.897000", "db": "NVD", "id": "CVE-2023-38936" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021659" } ], "trust": 0.8 } }
var-202307-1183
Vulnerability from variot
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202307-1183", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "f1202", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0br" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "3.0" }, { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" }, { "model": "f1202", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.2.0.20\\(408\\)" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" }, { "model": "fh1202", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.2.0.19_en" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" } ], "sources": [ { "db": "NVD", "id": "CVE-2023-37717" } ] }, "cve": "CVE-2023-37717", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-37717", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-37717", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202307-1259", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1259" }, { "db": "NVD", "id": "CVE-2023-37717" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient", "sources": [ { "db": "NVD", "id": "CVE-2023-37717" }, { "db": "VULMON", "id": "CVE-2023-37717" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-37717", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202307-1259", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-37717", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-37717" }, { "db": "CNNVD", "id": "CNNVD-202307-1259" }, { "db": "NVD", "id": "CVE-2023-37717" } ] }, "id": "VAR-202307-1183", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.5256526420000001 }, "last_update_date": "2024-08-14T15:41:40.794000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Tenda F1202 Buffer error vulnerability fix", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247158" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1259" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-37717" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromdhcplistclient/repot.md" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-37717/" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37717" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-37717" }, { "db": "CNNVD", "id": "CNNVD-202307-1259" }, { "db": "NVD", "id": "CVE-2023-37717" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-37717" }, { "db": "CNNVD", "id": "CNNVD-202307-1259" }, { "db": "NVD", "id": "CVE-2023-37717" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-14T00:00:00", "db": "VULMON", "id": "CVE-2023-37717" }, { "date": "2023-07-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-1259" }, { "date": "2023-07-14T00:15:09.477000", "db": "NVD", "id": "CVE-2023-37717" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-14T00:00:00", "db": "VULMON", "id": "CVE-2023-37717" }, { "date": "2023-07-24T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-1259" }, { "date": "2023-07-21T14:31:56.167000", "db": "NVD", "id": "CVE-2023-37717" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1259" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda F1202 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1259" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1259" } ], "trust": 0.6 } }
var-202210-1085
Vulnerability from variot
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/fromSetIpMacBind.
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202210-1085", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42168" } ] }, "cve": "CVE-2022-42168", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-42168", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-42168", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202210-1099", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1099" }, { "db": "NVD", "id": "CVE-2022-42168" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/fromSetIpMacBind.", "sources": [ { "db": "NVD", "id": "CVE-2022-42168" } ], "trust": 1.0 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-42168", "trust": 1.6 }, { "db": "CNNVD", "id": "CNNVD-202210-1099", "trust": 0.6 } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1099" }, { "db": "NVD", "id": "CVE-2022-42168" } ] }, "id": "VAR-202210-1085", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T14:24:29.220000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42168" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/ac10/fromsetipmacbind/readme.md" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-42168/" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1099" }, { "db": "NVD", "id": "CVE-2022-42168" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNNVD", "id": "CNNVD-202210-1099" }, { "db": "NVD", "id": "CVE-2022-42168" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1099" }, { "date": "2022-10-17T14:15:14.020000", "db": "NVD", "id": "CVE-2022-42168" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1099" }, { "date": "2022-10-19T15:07:17.750000", "db": "NVD", "id": "CVE-2022-42168" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1099" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1099" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1099" } ], "trust": 0.6 } }
var-202311-2440
Vulnerability from variot
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the list parameter in the function sub_49E098. Tenda AC10 is a wireless router made by China Tenda Company. The vulnerability is caused by the list parameter of the sub_49E098 function failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause Denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202311-2440", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac10", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v4.0v16.03.10.13" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06278" }, { "db": "NVD", "id": "CVE-2023-45479" } ] }, "cve": "CVE-2023-45479", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2024-06278", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-45479", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-45479", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2024-06278", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06278" }, { "db": "NVD", "id": "CVE-2023-45479" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the list parameter in the function sub_49E098. Tenda AC10 is a wireless router made by China Tenda Company. The vulnerability is caused by the list parameter of the sub_49E098 function failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause Denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2023-45479" }, { "db": "CNVD", "id": "CNVD-2024-06278" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-45479", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2024-06278", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06278" }, { "db": "NVD", "id": "CVE-2023-45479" } ] }, "id": "VAR-202311-2440", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-06278" } ], "trust": 0.86649562 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06278" } ] }, "last_update_date": "2024-08-14T15:31:46.438000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda AC10 sub_49E098 function buffer overflow vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/521556" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06278" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-45479" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://github.com/l3m0nade/iotvul/blob/master/assets/sub_49e098_code.png" }, { "trust": 1.0, "url": "https://github.com/l3m0nade/iotvul/blob/master/sub_49e098.md" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06278" }, { "db": "NVD", "id": "CVE-2023-45479" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-06278" }, { "db": "NVD", "id": "CVE-2023-45479" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-25T00:00:00", "db": "CNVD", "id": "CNVD-2024-06278" }, { "date": "2023-11-29T06:15:46.507000", "db": "NVD", "id": "CVE-2023-45479" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-29T00:00:00", "db": "CNVD", "id": "CNVD-2024-06278" }, { "date": "2023-12-01T03:59:39.983000", "db": "NVD", "id": "CVE-2023-45479" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 sub_49E098 function buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-06278" } ], "trust": 0.6 } }
var-201810-0275
Vulnerability from variot
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router's web server -- httpd. While processing the 'mac' parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow. plural Tenda The product contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0275", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac15", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.05.19_cn" }, { "model": "ac7", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac9", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac9", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac7 v15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac9 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 v15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac15 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac18 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01886" }, { "db": "JVNDB", "id": "JVNDB-2018-011969" }, { "db": "CNNVD", "id": "CNNVD-201810-1356" }, { "db": "NVD", "id": "CVE-2018-18729" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tenda:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac15_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac18_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011969" } ] }, "cve": "CVE-2018-18729", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2018-18729", "impactScore": 8.5, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2019-01886", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-129317", "impactScore": 8.5, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2018-18729", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-18729", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2018-18729", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2019-01886", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201810-1356", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-129317", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01886" }, { "db": "VULHUB", "id": "VHN-129317" }, { "db": "JVNDB", "id": "JVNDB-2018-011969" }, { "db": "CNNVD", "id": "CNNVD-201810-1356" }, { "db": "NVD", "id": "CVE-2018-18729" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow. plural Tenda The product contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version", "sources": [ { "db": "NVD", "id": "CVE-2018-18729" }, { "db": "JVNDB", "id": "JVNDB-2018-011969" }, { "db": "CNVD", "id": "CNVD-2019-01886" }, { "db": "VULHUB", "id": "VHN-129317" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-18729", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2018-011969", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201810-1356", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2019-01886", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-129317", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01886" }, { "db": "VULHUB", "id": "VHN-129317" }, { "db": "JVNDB", "id": "JVNDB-2018-011969" }, { "db": "CNNVD", "id": "CNNVD-201810-1356" }, { "db": "NVD", "id": "CVE-2018-18729" } ] }, "id": "VAR-201810-0275", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2019-01886" }, { "db": "VULHUB", "id": "VHN-129317" } ], "trust": 1.4236169144444446 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01886" } ] }, "last_update_date": "2024-11-23T22:58:50.557000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011969" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.1 }, { "problemtype": "CWE-119", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-129317" }, { "db": "JVNDB", "id": "JVNDB-2018-011969" }, { "db": "NVD", "id": "CVE-2018-18729" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/zillr0/routers/blob/master/tenda/heapoverflow1.md" }, { "trust": 1.4, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18729" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18729" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01886" }, { "db": "VULHUB", "id": "VHN-129317" }, { "db": "JVNDB", "id": "JVNDB-2018-011969" }, { "db": "CNNVD", "id": "CNNVD-201810-1356" }, { "db": "NVD", "id": "CVE-2018-18729" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2019-01886" }, { "db": "VULHUB", "id": "VHN-129317" }, { "db": "JVNDB", "id": "JVNDB-2018-011969" }, { "db": "CNNVD", "id": "CNNVD-201810-1356" }, { "db": "NVD", "id": "CVE-2018-18729" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-01-18T00:00:00", "db": "CNVD", "id": "CNVD-2019-01886" }, { "date": "2018-10-29T00:00:00", "db": "VULHUB", "id": "VHN-129317" }, { "date": "2019-01-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011969" }, { "date": "2018-10-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1356" }, { "date": "2018-10-29T12:29:07.617000", "db": "NVD", "id": "CVE-2018-18729" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-01-18T00:00:00", "db": "CNVD", "id": "CNVD-2019-01886" }, { "date": "2019-10-03T00:00:00", "db": "VULHUB", "id": "VHN-129317" }, { "date": "2019-01-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011969" }, { "date": "2019-10-23T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1356" }, { "date": "2024-11-21T03:56:28.197000", "db": "NVD", "id": "CVE-2018-18729" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1356" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Product buffer error vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011969" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1356" } ], "trust": 0.6 } }
var-202304-0487
Vulnerability from variot
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0487", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13_cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.13 cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006755" }, { "db": "NVD", "id": "CVE-2023-27020" } ] }, "cve": "CVE-2023-27020", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-27020", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-27020", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-27020", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-27020", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202304-480", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006755" }, { "db": "CNNVD", "id": "CNNVD-202304-480" }, { "db": "NVD", "id": "CVE-2023-27020" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-27020" }, { "db": "JVNDB", "id": "JVNDB-2023-006755" }, { "db": "VULMON", "id": "CVE-2023-27020" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-27020", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006755", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-480", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-27020", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27020" }, { "db": "JVNDB", "id": "JVNDB-2023-006755" }, { "db": "CNNVD", "id": "CNNVD-202304-480" }, { "db": "NVD", "id": "CVE-2023-27020" } ] }, "id": "VAR-202304-0487", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T13:20:53.413000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006755" }, { "db": "NVD", "id": "CVE-2023-27020" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac10/1/1.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-27020" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-27020/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27020" }, { "db": "JVNDB", "id": "JVNDB-2023-006755" }, { "db": "CNNVD", "id": "CNNVD-202304-480" }, { "db": "NVD", "id": "CVE-2023-27020" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-27020" }, { "db": "JVNDB", "id": "JVNDB-2023-006755" }, { "db": "CNNVD", "id": "CNNVD-202304-480" }, { "db": "NVD", "id": "CVE-2023-27020" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27020" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006755" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-480" }, { "date": "2023-04-07T02:15:08.507000", "db": "NVD", "id": "CVE-2023-27020" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27020" }, { "date": "2023-11-16T04:55:00", "db": "JVNDB", "id": "JVNDB-2023-006755" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-480" }, { "date": "2023-04-12T19:13:26.560000", "db": "NVD", "id": "CVE-2023-27020" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-480" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006755" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-480" } ], "trust": 0.6 } }
var-202308-4027
Vulnerability from variot
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. ac1206 firmware, AC5 firmware, AC9 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4027", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.42_multi" }, { "model": "ac8", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.34.06" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac1206", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac8", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "db": "NVD", "id": "CVE-2023-38935" } ] }, "cve": "CVE-2023-38935", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-38935", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-38935", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-38935", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-38935", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "db": "NVD", "id": "CVE-2023-38935" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. ac1206 firmware, AC5 firmware, AC9 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-38935" }, { "db": "JVNDB", "id": "JVNDB-2023-021660" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-38935", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-021660", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "db": "NVD", "id": "CVE-2023-38935" } ] }, "id": "VAR-202308-4027", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3871988366666666 }, "last_update_date": "2024-08-14T14:16:59.792000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "db": "NVD", "id": "CVE-2023-38935" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetqosband/readme.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38935" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "db": "NVD", "id": "CVE-2023-38935" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "db": "NVD", "id": "CVE-2023-38935" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "date": "2023-08-07T19:15:11.277000", "db": "NVD", "id": "CVE-2023-38935" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T07:51:00", "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "date": "2023-08-10T17:18:24.527000", "db": "NVD", "id": "CVE-2023-38935" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021660" } ], "trust": 0.8 } }
var-202411-0572
Vulnerability from variot
A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC10 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter wpapsk_crypto in the file /goform/WifiExtraSet failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202411-0572", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.13" }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-44853" }, { "db": "JVNDB", "id": "JVNDB-2024-012643" }, { "db": "NVD", "id": "CVE-2024-11056" } ] }, "cve": "CVE-2024-11056", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CVE-2024-11056", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.0, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "OTHER", "availabilityImpact": "Complete", "baseScore": 9.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "JVNDB-2024-012643", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-44853", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2024-11056", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2024-012643", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-11056", "trust": 1.0, "value": "High" }, { "author": "nvd@nist.gov", "id": "CVE-2024-11056", "trust": 1.0, "value": "HIGH" }, { "author": "OTHER", "id": "JVNDB-2024-012643", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2024-44853", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-44853" }, { "db": "JVNDB", "id": "JVNDB-2024-012643" }, { "db": "NVD", "id": "CVE-2024-11056" }, { "db": "NVD", "id": "CVE-2024-11056" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC10 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter wpapsk_crypto in the file /goform/WifiExtraSet failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2024-11056" }, { "db": "JVNDB", "id": "JVNDB-2024-012643" }, { "db": "CNVD", "id": "CNVD-2024-44853" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-11056", "trust": 3.2 }, { "db": "VULDB", "id": "283800", "trust": 1.6 }, { "db": "JVNDB", "id": "JVNDB-2024-012643", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2024-44853", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-44853" }, { "db": "JVNDB", "id": "JVNDB-2024-012643" }, { "db": "NVD", "id": "CVE-2024-11056" } ] }, "id": "VAR-202411-0572", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-44853" } ], "trust": 0.86649562 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-44853" } ] }, "last_update_date": "2024-11-16T22:57:32.307000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda AC10 Buffer Overflow Vulnerability (CNVD-2024-44853)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/618211" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-44853" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.0 }, { "problemtype": "CWE-121", "trust": 1.0 }, { "problemtype": "Buffer error (CWE-119) [ others ]", "trust": 0.8 }, { "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-012643" }, { "db": "NVD", "id": "CVE-2024-11056" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://tasty-foxtrot-3a8.notion.site/tenda-ac10v4-stack-overflow-1380448e619580409bb1e1ac85f45570" }, { "trust": 1.8, "url": "https://vuldb.com/?submit.439358" }, { "trust": 1.8, "url": "https://www.tenda.com.cn/" }, { "trust": 1.6, "url": "https://vuldb.com/?id.283800" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.283800" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-11056" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-44853" }, { "db": "JVNDB", "id": "JVNDB-2024-012643" }, { "db": "NVD", "id": "CVE-2024-11056" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-44853" }, { "db": "JVNDB", "id": "JVNDB-2024-012643" }, { "db": "NVD", "id": "CVE-2024-11056" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-11-14T00:00:00", "db": "CNVD", "id": "CNVD-2024-44853" }, { "date": "2024-11-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2024-012643" }, { "date": "2024-11-10T17:15:15.697000", "db": "NVD", "id": "CVE-2024-11056" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-11-14T00:00:00", "db": "CNVD", "id": "CNVD-2024-44853" }, { "date": "2024-11-15T01:10:00", "db": "JVNDB", "id": "JVNDB-2024-012643" }, { "date": "2024-11-14T15:21:09.907000", "db": "NVD", "id": "CVE-2024-11056" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Buffer error vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-012643" } ], "trust": 0.8 } }
var-202306-0582
Vulnerability from variot
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202306-0582", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "us_ac10v4.0si_v16.03.10.13_cn" } ], "sources": [ { "db": "NVD", "id": "CVE-2023-34567" } ] }, "cve": "CVE-2023-34567", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "id": "CVE-2023-34567", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-34567", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202306-621", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-621" }, { "db": "NVD", "id": "CVE-2023-34567" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.", "sources": [ { "db": "NVD", "id": "CVE-2023-34567" } ], "trust": 1.0 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-34567", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202306-621", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-34567", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-34567" }, { "db": "CNNVD", "id": "CNNVD-202306-621" }, { "db": "NVD", "id": "CVE-2023-34567" } ] }, "id": "VAR-202306-0582", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T14:23:59.608000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-34567" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://hackmd.io/%400dayresearch/h1xuqzfhh" }, { "trust": 0.7, "url": "https://hackmd.io/@0dayresearch/h1xuqzfhh" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-34567/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-34567" }, { "db": "CNNVD", "id": "CNNVD-202306-621" }, { "db": "NVD", "id": "CVE-2023-34567" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-34567" }, { "db": "CNNVD", "id": "CNNVD-202306-621" }, { "db": "NVD", "id": "CVE-2023-34567" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-08T00:00:00", "db": "VULMON", "id": "CVE-2023-34567" }, { "date": "2023-06-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202306-621" }, { "date": "2023-06-08T15:15:09.607000", "db": "NVD", "id": "CVE-2023-34567" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-08T00:00:00", "db": "VULMON", "id": "CVE-2023-34567" }, { "date": "2023-06-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202306-621" }, { "date": "2023-11-07T04:15:39.440000", "db": "NVD", "id": "CVE-2023-34567" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-621" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-621" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-621" } ], "trust": 0.6 } }
var-202308-3781
Vulnerability from variot
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3781", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.42_multi" }, { "model": "fh1205", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.0.7\\(775\\)" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.44" }, { "model": "ac6", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "f1203", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.1.6" }, { "model": "fh1203", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.1.6" }, { "model": "ac1206", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "fh1203", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac6", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "fh1205", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "f1203", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "db": "NVD", "id": "CVE-2023-38933" } ] }, "cve": "CVE-2023-38933", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-38933", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-38933", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-38933", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-38933", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "db": "NVD", "id": "CVE-2023-38933" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-38933" }, { "db": "JVNDB", "id": "JVNDB-2023-021661" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-38933", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-021661", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "db": "NVD", "id": "CVE-2023-38933" } ] }, "id": "VAR-202308-3781", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3288697725 }, "last_update_date": "2024-08-14T13:19:52.824000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "db": "NVD", "id": "CVE-2023-38933" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetclientstate/readme.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38933" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "db": "NVD", "id": "CVE-2023-38933" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "db": "NVD", "id": "CVE-2023-38933" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "date": "2023-08-07T19:15:11.133000", "db": "NVD", "id": "CVE-2023-38933" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T07:51:00", "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "date": "2023-08-10T17:17:41.653000", "db": "NVD", "id": "CVE-2023-38933" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021661" } ], "trust": 0.8 } }
var-202311-2319
Vulnerability from variot
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info.
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202311-2319", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" } ], "sources": [ { "db": "NVD", "id": "CVE-2023-45482" } ] }, "cve": "CVE-2023-45482", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-45482", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-45482", "trust": 1.0, "value": "CRITICAL" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-45482" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info.", "sources": [ { "db": "NVD", "id": "CVE-2023-45482" } ], "trust": 1.0 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-45482", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-45482" } ] }, "id": "VAR-202311-2319", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T14:16:50.180000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-45482" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/l3m0nade/iotvul/blob/master/assets/get_parentcontrol_list_info_code.png" }, { "trust": 1.0, "url": "https://github.com/l3m0nade/iotvul/blob/master/get_parentcontrol_list_info.md" } ], "sources": [ { "db": "NVD", "id": "CVE-2023-45482" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "NVD", "id": "CVE-2023-45482" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-11-29T06:15:46.710000", "db": "NVD", "id": "CVE-2023-45482" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-01T03:58:37.397000", "db": "NVD", "id": "CVE-2023-45482" } ] } }
var-202307-0484
Vulnerability from variot
Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac. Tenda of AC10 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10 is a wireless router made by China Tenda Company. The vulnerability stems from the failure of the application to properly filter special characters, commands, etc. in constructing commands
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202307-0484", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tendacn", "version": "15.03.06.26" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 15.03.06.26" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v15.03.06.26" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-58826" }, { "db": "JVNDB", "id": "JVNDB-2023-017091" }, { "db": "NVD", "id": "CVE-2023-37144" } ] }, "cve": "CVE-2023-37144", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-58826", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-37144", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-37144", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-37144", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-37144", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2023-58826", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202307-483", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-58826" }, { "db": "JVNDB", "id": "JVNDB-2023-017091" }, { "db": "CNNVD", "id": "CNNVD-202307-483" }, { "db": "NVD", "id": "CVE-2023-37144" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac. Tenda of AC10 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10 is a wireless router made by China Tenda Company. The vulnerability stems from the failure of the application to properly filter special characters, commands, etc. in constructing commands", "sources": [ { "db": "NVD", "id": "CVE-2023-37144" }, { "db": "JVNDB", "id": "JVNDB-2023-017091" }, { "db": "CNVD", "id": "CNVD-2023-58826" }, { "db": "VULMON", "id": "CVE-2023-37144" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-37144", "trust": 3.9 }, { "db": "JVNDB", "id": "JVNDB-2023-017091", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-58826", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202307-483", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-37144", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-58826" }, { "db": "VULMON", "id": "CVE-2023-37144" }, { "db": "JVNDB", "id": "JVNDB-2023-017091" }, { "db": "CNNVD", "id": "CNNVD-202307-483" }, { "db": "NVD", "id": "CVE-2023-37144" } ] }, "id": "VAR-202307-0484", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-58826" } ], "trust": 0.86649562 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-58826" } ] }, "last_update_date": "2024-08-14T15:00:13.973000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda AC10 Command Execution Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/440336" }, { "title": "Tenda AC10 Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=245901" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-58826" }, { "db": "CNNVD", "id": "CNNVD-202307-483" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-017091" }, { "db": "NVD", "id": "CVE-2023-37144" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://github.com/dadong-g/vulnerability_info/blob/main/ac10_command_injection/readme.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37144" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-37144/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-58826" }, { "db": "VULMON", "id": "CVE-2023-37144" }, { "db": "JVNDB", "id": "JVNDB-2023-017091" }, { "db": "CNNVD", "id": "CNNVD-202307-483" }, { "db": "NVD", "id": "CVE-2023-37144" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-58826" }, { "db": "VULMON", "id": "CVE-2023-37144" }, { "db": "JVNDB", "id": "JVNDB-2023-017091" }, { "db": "CNNVD", "id": "CNNVD-202307-483" }, { "db": "NVD", "id": "CVE-2023-37144" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-13T00:00:00", "db": "CNVD", "id": "CNVD-2023-58826" }, { "date": "2023-07-07T00:00:00", "db": "VULMON", "id": "CVE-2023-37144" }, { "date": "2024-01-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-017091" }, { "date": "2023-07-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-483" }, { "date": "2023-07-07T14:15:09.363000", "db": "NVD", "id": "CVE-2023-37144" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-26T00:00:00", "db": "CNVD", "id": "CNVD-2023-58826" }, { "date": "2023-07-07T00:00:00", "db": "VULMON", "id": "CVE-2023-37144" }, { "date": "2024-01-05T08:09:00", "db": "JVNDB", "id": "JVNDB-2023-017091" }, { "date": "2023-07-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-483" }, { "date": "2023-07-12T20:43:13.663000", "db": "NVD", "id": "CVE-2023-37144" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-483" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda\u00a0 of \u00a0AC10\u00a0 Command injection vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-017091" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-483" } ], "trust": 0.6 } }
var-202304-0486
Vulnerability from variot
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45EC1C function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0486", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13_cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.13 cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006757" }, { "db": "NVD", "id": "CVE-2023-27018" } ] }, "cve": "CVE-2023-27018", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-27018", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-27018", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-27018", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-27018", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202304-484", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006757" }, { "db": "CNNVD", "id": "CNNVD-202304-484" }, { "db": "NVD", "id": "CVE-2023-27018" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45EC1C function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-27018" }, { "db": "JVNDB", "id": "JVNDB-2023-006757" }, { "db": "VULMON", "id": "CVE-2023-27018" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-27018", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006757", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-484", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-27018", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27018" }, { "db": "JVNDB", "id": "JVNDB-2023-006757" }, { "db": "CNNVD", "id": "CNNVD-202304-484" }, { "db": "NVD", "id": "CVE-2023-27018" } ] }, "id": "VAR-202304-0486", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T14:43:20.771000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006757" }, { "db": "NVD", "id": "CVE-2023-27018" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac10/7/7.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-27018" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-27018/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27018" }, { "db": "JVNDB", "id": "JVNDB-2023-006757" }, { "db": "CNNVD", "id": "CNNVD-202304-484" }, { "db": "NVD", "id": "CVE-2023-27018" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-27018" }, { "db": "JVNDB", "id": "JVNDB-2023-006757" }, { "db": "CNNVD", "id": "CNNVD-202304-484" }, { "db": "NVD", "id": "CVE-2023-27018" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27018" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006757" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-484" }, { "date": "2023-04-07T02:15:08.433000", "db": "NVD", "id": "CVE-2023-27018" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27018" }, { "date": "2023-11-16T04:59:00", "db": "JVNDB", "id": "JVNDB-2023-006757" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-484" }, { "date": "2023-04-12T19:08:25.300000", "db": "NVD", "id": "CVE-2023-27018" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-484" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006757" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-484" } ], "trust": 0.6 } }
var-202403-0882
Vulnerability from variot
A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of ac10u The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.
There is an operating system command injection vulnerability in the Tenda AC10U 15.03.06.48 version. The vulnerability is caused by the usbName parameter in the formSetSambaConf method of the /goform/setsambacfg page failing to properly filter special characters and commands in the constructed command. Attackers can exploit this vulnerability to cause arbitrary command execution
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0882", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10u", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.48" }, { "model": "ac10u", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.49" }, { "model": "ac10u", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10u", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10u firmware 15.03.06.48" }, { "model": "ac10u", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10u", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10u firmware 15.03.06.49" }, { "model": "ac10", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "15.03.06.48" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20300" }, { "db": "JVNDB", "id": "JVNDB-2024-003027" }, { "db": "NVD", "id": "CVE-2024-2853" } ] }, "cve": "CVE-2024-2853", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2024-2853", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CNVD-2024-20300", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.8, "id": "CVE-2024-2853", "impactScore": 3.4, "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2024-2853", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2024-2853", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-2853", "trust": 1.0, "value": "MEDIUM" }, { "author": "nvd@nist.gov", "id": "CVE-2024-2853", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2024-2853", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2024-20300", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20300" }, { "db": "JVNDB", "id": "JVNDB-2024-003027" }, { "db": "NVD", "id": "CVE-2024-2853" }, { "db": "NVD", "id": "CVE-2024-2853" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of ac10u The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nThere is an operating system command injection vulnerability in the Tenda AC10U 15.03.06.48 version. The vulnerability is caused by the usbName parameter in the formSetSambaConf method of the /goform/setsambacfg page failing to properly filter special characters and commands in the constructed command. Attackers can exploit this vulnerability to cause arbitrary command execution", "sources": [ { "db": "NVD", "id": "CVE-2024-2853" }, { "db": "JVNDB", "id": "JVNDB-2024-003027" }, { "db": "CNVD", "id": "CNVD-2024-20300" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-2853", "trust": 3.2 }, { "db": "VULDB", "id": "257777", "trust": 1.8 }, { "db": "JVNDB", "id": "JVNDB-2024-003027", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2024-20300", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20300" }, { "db": "JVNDB", "id": "JVNDB-2024-003027" }, { "db": "NVD", "id": "CVE-2024-2853" } ] }, "id": "VAR-202403-0882", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-20300" } ], "trust": 0.86649562 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20300" } ] }, "last_update_date": "2024-08-14T15:10:18.770000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda AC10 operating system command injection vulnerability (CNVD-2024-20300)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/541136" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20300" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-78", "trust": 1.0 }, { "problemtype": "OS Command injection (CWE-78) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-003027" }, { "db": "NVD", "id": "CVE-2024-2853" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac10u/v1.v15.03.06.48/more/formsetsambaconf.md" }, { "trust": 1.8, "url": "https://vuldb.com/?id.257777" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2853" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.257777" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20300" }, { "db": "JVNDB", "id": "JVNDB-2024-003027" }, { "db": "NVD", "id": "CVE-2024-2853" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-20300" }, { "db": "JVNDB", "id": "JVNDB-2024-003027" }, { "db": "NVD", "id": "CVE-2024-2853" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-04-12T00:00:00", "db": "CNVD", "id": "CNVD-2024-20300" }, { "date": "2024-03-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2024-003027" }, { "date": "2024-03-24T05:15:10.517000", "db": "NVD", "id": "CVE-2024-2853" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-04-25T00:00:00", "db": "CNVD", "id": "CNVD-2024-20300" }, { "date": "2024-03-28T00:47:00", "db": "JVNDB", "id": "JVNDB-2024-003027" }, { "date": "2024-05-17T02:38:34.337000", "db": "NVD", "id": "CVE-2024-2853" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac10u\u00a0 in the firmware \u00a0OS\u00a0 Command injection vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-003027" } ], "trust": 0.8 } }
var-202410-1497
Vulnerability from variot
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. AC15 firmware, AC7 firmware, ac10u firmware etc. The product has NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202410-1497", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac18", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.48.23" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.2.13" }, { "model": "ac500", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0.0.16" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.20" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.42" }, { "model": "ac8", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.34.09" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.44" }, { "model": "ac500", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0.0.14" }, { "model": "ac500", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.1.9\\(1307\\)" }, { "model": "ac15", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.05.19" }, { "model": "ac15", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.05.18" }, { "model": "ac8", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.34.06" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.48.19" }, { "model": "ac10u", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.48" }, { "model": "ac18", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.05.05" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac10u", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.49" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.05.14" }, { "model": "ac6", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac18", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10u", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac15", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac1206", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac6", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac500", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-011851" }, { "db": "NVD", "id": "CVE-2024-10280" } ] }, "cve": "CVE-2024-10280", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 6.8, "confidentialityImpact": "NONE", "exploitabilityScore": 8.0, "id": "CVE-2024-10280", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "OTHER", "availabilityImpact": "Complete", "baseScore": 6.8, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2024-011851", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "id": "CVE-2024-10280", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2024-10280", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2024-011851", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-10280", "trust": 1.0, "value": "High" }, { "author": "nvd@nist.gov", "id": "CVE-2024-10280", "trust": 1.0, "value": "HIGH" }, { "author": "OTHER", "id": "JVNDB-2024-011851", "trust": 0.8, "value": "High" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-011851" }, { "db": "NVD", "id": "CVE-2024-10280" }, { "db": "NVD", "id": "CVE-2024-10280" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. AC15 firmware, AC7 firmware, ac10u firmware etc. The product has NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2024-10280" }, { "db": "JVNDB", "id": "JVNDB-2024-011851" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-10280", "trust": 2.6 }, { "db": "VULDB", "id": "281555", "trust": 1.8 }, { "db": "JVNDB", "id": "JVNDB-2024-011851", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-011851" }, { "db": "NVD", "id": "CVE-2024-10280" } ] }, "id": "VAR-202410-1497", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.4059792066666667 }, "last_update_date": "2024-11-07T22:35:04.235000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-476", "trust": 1.0 }, { "problemtype": "NULL Pointer dereference (CWE-476) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-011851" }, { "db": "NVD", "id": "CVE-2024-10280" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/johenanli/router_vuls/blob/main/websreadevent/websreadevent.md" }, { "trust": 1.8, "url": "https://vuldb.com/?id.281555" }, { "trust": 1.8, "url": "https://vuldb.com/?submit.426417" }, { "trust": 1.8, "url": "https://www.tenda.com.cn/" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.281555" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-10280" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-011851" }, { "db": "NVD", "id": "CVE-2024-10280" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2024-011851" }, { "db": "NVD", "id": "CVE-2024-10280" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-11-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2024-011851" }, { "date": "2024-10-23T14:15:04.500000", "db": "NVD", "id": "CVE-2024-10280" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-11-05T02:27:00", "db": "JVNDB", "id": "JVNDB-2024-011851" }, { "date": "2024-11-01T14:03:20.267000", "db": "NVD", "id": "CVE-2024-10280" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 In the product \u00a0NULL\u00a0 Pointer dereference vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-011851" } ], "trust": 0.8 } }
var-202210-1127
Vulnerability from variot
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/saveParentControlInfo.
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202210-1127", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42171" } ] }, "cve": "CVE-2022-42171", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-42171", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-42171", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202210-1090", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1090" }, { "db": "NVD", "id": "CVE-2022-42171" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/saveParentControlInfo.", "sources": [ { "db": "NVD", "id": "CVE-2022-42171" } ], "trust": 1.0 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-42171", "trust": 1.6 }, { "db": "CNNVD", "id": "CNNVD-202210-1090", "trust": 0.6 } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1090" }, { "db": "NVD", "id": "CVE-2022-42171" } ] }, "id": "VAR-202210-1127", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T14:24:29.186000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42171" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/ac10/saveparentcontrolinfo/readme.md" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-42171/" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1090" }, { "db": "NVD", "id": "CVE-2022-42171" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNNVD", "id": "CNNVD-202210-1090" }, { "db": "NVD", "id": "CVE-2022-42171" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1090" }, { "date": "2022-10-17T14:15:14.323000", "db": "NVD", "id": "CVE-2022-42171" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1090" }, { "date": "2022-10-19T15:06:13.953000", "db": "NVD", "id": "CVE-2022-42171" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1090" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1090" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1090" } ], "trust": 0.6 } }
var-202306-0680
Vulnerability from variot
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202306-0680", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "us_ac10v4.0si_v16.03.10.13_cn" } ], "sources": [ { "db": "NVD", "id": "CVE-2023-34568" } ] }, "cve": "CVE-2023-34568", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "id": "CVE-2023-34568", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-34568", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202306-623", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-623" }, { "db": "NVD", "id": "CVE-2023-34568" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.", "sources": [ { "db": "NVD", "id": "CVE-2023-34568" } ], "trust": 1.0 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-34568", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202306-623", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-34568", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-34568" }, { "db": "CNNVD", "id": "CNNVD-202306-623" }, { "db": "NVD", "id": "CVE-2023-34568" } ] }, "id": "VAR-202306-0680", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T15:10:44.937000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-34568" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://hackmd.io/%400dayresearch/ryr8izmh2" }, { "trust": 0.7, "url": "https://hackmd.io/@0dayresearch/ryr8izmh2" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-34568/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-34568" }, { "db": "CNNVD", "id": "CNNVD-202306-623" }, { "db": "NVD", "id": "CVE-2023-34568" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-34568" }, { "db": "CNNVD", "id": "CNNVD-202306-623" }, { "db": "NVD", "id": "CVE-2023-34568" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-08T00:00:00", "db": "VULMON", "id": "CVE-2023-34568" }, { "date": "2023-06-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202306-623" }, { "date": "2023-06-08T15:15:09.653000", "db": "NVD", "id": "CVE-2023-34568" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-08T00:00:00", "db": "VULMON", "id": "CVE-2023-34568" }, { "date": "2023-06-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202306-623" }, { "date": "2023-11-07T04:15:40.463000", "db": "NVD", "id": "CVE-2023-34568" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-623" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-623" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-623" } ], "trust": 0.6 } }
var-202307-1134
Vulnerability from variot
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function. Shenzhen Tenda Technology Co.,Ltd. of AC10 firmware and ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202307-1134", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.47" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac1206", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019246" }, { "db": "NVD", "id": "CVE-2023-37710" } ] }, "cve": "CVE-2023-37710", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-37710", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-37710", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-37710", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-37710", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202307-530", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019246" }, { "db": "CNNVD", "id": "CNNVD-202307-530" }, { "db": "NVD", "id": "CVE-2023-37710" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function. Shenzhen Tenda Technology Co.,Ltd. of AC10 firmware and ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-37710" }, { "db": "JVNDB", "id": "JVNDB-2023-019246" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-37710", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2023-019246", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202307-530", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019246" }, { "db": "CNNVD", "id": "CNNVD-202307-530" }, { "db": "NVD", "id": "CVE-2023-37710" } ] }, "id": "VAR-202307-1134", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.36157598 }, "last_update_date": "2024-08-14T15:05:34.334000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Tenda AC1206 Buffer error vulnerability fix", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=246055" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-530" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019246" }, { "db": "NVD", "id": "CVE-2023-37710" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/firmrec/iot-vulns/tree/main/tenda/fromsetwirelessrepeat" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37710" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-37710/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019246" }, { "db": "CNNVD", "id": "CNNVD-202307-530" }, { "db": "NVD", "id": "CVE-2023-37710" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-019246" }, { "db": "CNNVD", "id": "CNNVD-202307-530" }, { "db": "NVD", "id": "CVE-2023-37710" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-019246" }, { "date": "2023-07-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-530" }, { "date": "2023-07-10T17:15:09.797000", "db": "NVD", "id": "CVE-2023-37710" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-12T08:04:00", "db": "JVNDB", "id": "JVNDB-2023-019246" }, { "date": "2023-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-530" }, { "date": "2023-07-13T19:47:08.147000", "db": "NVD", "id": "CVE-2023-37710" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-530" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 firmware and \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019246" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-530" } ], "trust": 0.6 } }
var-201810-0243
Vulnerability from variot
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0243", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac15", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.05.19_cn" }, { "model": "ac7", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac9", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac9", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac7 v15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac9 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 v15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac15 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac18 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-09140" }, { "db": "JVNDB", "id": "JVNDB-2018-011965" }, { "db": "CNNVD", "id": "CNNVD-201810-1337" }, { "db": "NVD", "id": "CVE-2018-18706" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tenda:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac15_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac18_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011965" } ] }, "cve": "CVE-2018-18706", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-18706", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2019-09140", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-129292", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-18706", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-18706", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-18706", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-09140", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201810-1337", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-129292", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-09140" }, { "db": "VULHUB", "id": "VHN-129292" }, { "db": "JVNDB", "id": "JVNDB-2018-011965" }, { "db": "CNNVD", "id": "CNNVD-201810-1337" }, { "db": "NVD", "id": "CVE-2018-18706" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version", "sources": [ { "db": "NVD", "id": "CVE-2018-18706" }, { "db": "JVNDB", "id": "JVNDB-2018-011965" }, { "db": "CNVD", "id": "CNVD-2019-09140" }, { "db": "VULHUB", "id": "VHN-129292" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-18706", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2018-011965", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201810-1337", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2019-09140", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-129292", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-09140" }, { "db": "VULHUB", "id": "VHN-129292" }, { "db": "JVNDB", "id": "JVNDB-2018-011965" }, { "db": "CNNVD", "id": "CNNVD-201810-1337" }, { "db": "NVD", "id": "CVE-2018-18706" } ] }, "id": "VAR-201810-0243", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2019-09140" }, { "db": "VULHUB", "id": "VHN-129292" } ], "trust": 1.4236169144444446 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-09140" } ] }, "last_update_date": "2024-11-23T22:12:19.756000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011965" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-129292" }, { "db": "JVNDB", "id": "JVNDB-2018-011965" }, { "db": "NVD", "id": "CVE-2018-18706" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/tenda.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18706" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18706" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-09140" }, { "db": "VULHUB", "id": "VHN-129292" }, { "db": "JVNDB", "id": "JVNDB-2018-011965" }, { "db": "CNNVD", "id": "CNNVD-201810-1337" }, { "db": "NVD", "id": "CVE-2018-18706" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2019-09140" }, { "db": "VULHUB", "id": "VHN-129292" }, { "db": "JVNDB", "id": "JVNDB-2018-011965" }, { "db": "CNNVD", "id": "CNNVD-201810-1337" }, { "db": "NVD", "id": "CVE-2018-18706" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-04-04T00:00:00", "db": "CNVD", "id": "CNVD-2019-09140" }, { "date": "2018-10-29T00:00:00", "db": "VULHUB", "id": "VHN-129292" }, { "date": "2019-01-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011965" }, { "date": "2018-10-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1337" }, { "date": "2018-10-29T12:29:05.400000", "db": "NVD", "id": "CVE-2018-18706" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-04-04T00:00:00", "db": "CNVD", "id": "CNVD-2019-09140" }, { "date": "2018-12-14T00:00:00", "db": "VULHUB", "id": "VHN-129292" }, { "date": "2019-01-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011965" }, { "date": "2018-10-31T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1337" }, { "date": "2024-11-21T03:56:24.723000", "db": "NVD", "id": "CVE-2018-18706" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1337" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Product buffer error vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011965" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer overflow", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1337" } ], "trust": 0.6 } }
var-202210-1219
Vulnerability from variot
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetClientState. Tenda AC10 is a wireless router. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system, or cause a denial of service
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202210-1219", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v15.03.06.23" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-50811" }, { "db": "NVD", "id": "CVE-2022-42164" } ] }, "cve": "CVE-2022-42164", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-50811", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-42164", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-42164", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2023-50811", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202210-1066", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-50811" }, { "db": "CNNVD", "id": "CNNVD-202210-1066" }, { "db": "NVD", "id": "CVE-2022-42164" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetClientState. Tenda AC10 is a wireless router. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system, or cause a denial of service", "sources": [ { "db": "NVD", "id": "CVE-2022-42164" }, { "db": "CNVD", "id": "CNVD-2023-50811" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-42164", "trust": 2.2 }, { "db": "CNVD", "id": "CNVD-2023-50811", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202210-1066", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-50811" }, { "db": "CNNVD", "id": "CNNVD-202210-1066" }, { "db": "NVD", "id": "CVE-2022-42164" } ] }, "id": "VAR-202210-1219", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-50811" } ], "trust": 0.86649562 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-50811" } ] }, "last_update_date": "2024-08-14T13:21:35.669000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42164" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/ac10/formsetclientstate/readme.md" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-42164" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-42164/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-50811" }, { "db": "CNNVD", "id": "CNNVD-202210-1066" }, { "db": "NVD", "id": "CVE-2022-42164" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-50811" }, { "db": "CNNVD", "id": "CNNVD-202210-1066" }, { "db": "NVD", "id": "CVE-2022-42164" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-25T00:00:00", "db": "CNVD", "id": "CNVD-2023-50811" }, { "date": "2022-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1066" }, { "date": "2022-10-17T13:15:10.747000", "db": "NVD", "id": "CVE-2022-42164" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-25T00:00:00", "db": "CNVD", "id": "CNVD-2023-50811" }, { "date": "2022-10-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1066" }, { "date": "2022-10-19T15:08:04.237000", "db": "NVD", "id": "CVE-2022-42164" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1066" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Stack Buffer Overflow Vulnerability (CNVD-2023-50811)", "sources": [ { "db": "CNVD", "id": "CNVD-2023-50811" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1066" } ], "trust": 0.6 } }
var-201809-0931
Vulnerability from variot
An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN and AC10 V15.03.06.23_CN devices. The mac parameter in a POST request is used directly in a doSystemCmd call, causing OS command injection. Tenda AC9 and AC10 The device includes OS A command injection vulnerability exists.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC9 is a wireless router product from Tenda. The operating system command injection vulnerability exists in TendaAC915.03.05.19 (6318)_CN version and AC1015.03.06.23_CN version and previous versions
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0931", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac9", "scope": "eq", "trust": 1.6, "vendor": "tendacn", "version": "15.03.05.19" }, { "model": "ac10", "scope": "lte", "trust": 1.0, "vendor": "tendacn", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac9", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac10 \u003c=15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac9 15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": "eq", "trust": 0.6, "vendor": "tendacn", "version": "15.03.06.23" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-19080" }, { "db": "JVNDB", "id": "JVNDB-2018-009402" }, { "db": "CNNVD", "id": "CNNVD-201809-035" }, { "db": "NVD", "id": "CVE-2018-16334" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tendacn:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-009402" } ] }, "cve": "CVE-2018-16334", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CVE-2018-16334", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CNVD-2018-19080", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "VHN-126683", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2018-16334", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-16334", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-16334", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2018-19080", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201809-035", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-126683", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-19080" }, { "db": "VULHUB", "id": "VHN-126683" }, { "db": "JVNDB", "id": "JVNDB-2018-009402" }, { "db": "CNNVD", "id": "CNNVD-201809-035" }, { "db": "NVD", "id": "CVE-2018-16334" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN and AC10 V15.03.06.23_CN devices. The mac parameter in a POST request is used directly in a doSystemCmd call, causing OS command injection. Tenda AC9 and AC10 The device includes OS A command injection vulnerability exists.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC9 is a wireless router product from Tenda. The operating system command injection vulnerability exists in TendaAC915.03.05.19 (6318)_CN version and AC1015.03.06.23_CN version and previous versions", "sources": [ { "db": "NVD", "id": "CVE-2018-16334" }, { "db": "JVNDB", "id": "JVNDB-2018-009402" }, { "db": "CNVD", "id": "CNVD-2018-19080" }, { "db": "VULHUB", "id": "VHN-126683" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-16334", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2018-009402", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201809-035", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2018-19080", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-126683", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-19080" }, { "db": "VULHUB", "id": "VHN-126683" }, { "db": "JVNDB", "id": "JVNDB-2018-009402" }, { "db": "CNNVD", "id": "CNNVD-201809-035" }, { "db": "NVD", "id": "CVE-2018-16334" } ] }, "id": "VAR-201809-0931", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2018-19080" }, { "db": "VULHUB", "id": "VHN-126683" } ], "trust": 1.3762350424999998 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-19080" } ] }, "last_update_date": "2024-11-23T22:12:20.639000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-009402" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-78", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-126683" }, { "db": "JVNDB", "id": "JVNDB-2018-009402" }, { "db": "NVD", "id": "CVE-2018-16334" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-04/tenda.md" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-16334" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-16334" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-19080" }, { "db": "VULHUB", "id": "VHN-126683" }, { "db": "JVNDB", "id": "JVNDB-2018-009402" }, { "db": "CNNVD", "id": "CNNVD-201809-035" }, { "db": "NVD", "id": "CVE-2018-16334" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2018-19080" }, { "db": "VULHUB", "id": "VHN-126683" }, { "db": "JVNDB", "id": "JVNDB-2018-009402" }, { "db": "CNNVD", "id": "CNNVD-201809-035" }, { "db": "NVD", "id": "CVE-2018-16334" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-09-17T00:00:00", "db": "CNVD", "id": "CNVD-2018-19080" }, { "date": "2018-09-02T00:00:00", "db": "VULHUB", "id": "VHN-126683" }, { "date": "2018-11-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-009402" }, { "date": "2018-09-03T00:00:00", "db": "CNNVD", "id": "CNNVD-201809-035" }, { "date": "2018-09-02T03:29:00.760000", "db": "NVD", "id": "CVE-2018-16334" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-09-18T00:00:00", "db": "CNVD", "id": "CNVD-2018-19080" }, { "date": "2018-10-25T00:00:00", "db": "VULHUB", "id": "VHN-126683" }, { "date": "2018-11-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-009402" }, { "date": "2018-09-03T00:00:00", "db": "CNNVD", "id": "CNNVD-201809-035" }, { "date": "2024-11-21T03:52:32.727000", "db": "NVD", "id": "CVE-2018-16334" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201809-035" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC9 and AC10 In the device OS Command injection vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-009402" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-201809-035" } ], "trust": 0.6 } }
var-202304-0485
Vulnerability from variot
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0485", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13_cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.13 cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006854" }, { "db": "NVD", "id": "CVE-2023-27012" } ] }, "cve": "CVE-2023-27012", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-27012", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-27012", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-27012", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-27012", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202304-490", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006854" }, { "db": "CNNVD", "id": "CNNVD-202304-490" }, { "db": "NVD", "id": "CVE-2023-27012" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-27012" }, { "db": "JVNDB", "id": "JVNDB-2023-006854" }, { "db": "VULMON", "id": "CVE-2023-27012" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-27012", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006854", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-490", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-27012", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27012" }, { "db": "JVNDB", "id": "JVNDB-2023-006854" }, { "db": "CNNVD", "id": "CNNVD-202304-490" }, { "db": "NVD", "id": "CVE-2023-27012" } ] }, "id": "VAR-202304-0485", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T15:41:52.253000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006854" }, { "db": "NVD", "id": "CVE-2023-27012" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac10/5/5.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-27012" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-27012/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27012" }, { "db": "JVNDB", "id": "JVNDB-2023-006854" }, { "db": "CNNVD", "id": "CNNVD-202304-490" }, { "db": "NVD", "id": "CVE-2023-27012" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-27012" }, { "db": "JVNDB", "id": "JVNDB-2023-006854" }, { "db": "CNNVD", "id": "CNNVD-202304-490" }, { "db": "NVD", "id": "CVE-2023-27012" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27012" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006854" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-490" }, { "date": "2023-04-07T02:15:08.213000", "db": "NVD", "id": "CVE-2023-27012" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27012" }, { "date": "2023-11-16T07:03:00", "db": "JVNDB", "id": "JVNDB-2023-006854" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-490" }, { "date": "2023-04-13T18:03:39.643000", "db": "NVD", "id": "CVE-2023-27012" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-490" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006854" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-490" } ], "trust": 0.6 } }
var-202210-1138
Vulnerability from variot
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetSpeedWan.
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202210-1138", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42166" } ] }, "cve": "CVE-2022-42166", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-42166", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-42166", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202210-1096", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1096" }, { "db": "NVD", "id": "CVE-2022-42166" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetSpeedWan.", "sources": [ { "db": "NVD", "id": "CVE-2022-42166" } ], "trust": 1.0 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-42166", "trust": 1.6 }, { "db": "CNNVD", "id": "CNNVD-202210-1096", "trust": 0.6 } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1096" }, { "db": "NVD", "id": "CVE-2022-42166" } ] }, "id": "VAR-202210-1138", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T15:42:11.685000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42166" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/ac10/formsetspeedwan/readme.md" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-42166/" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1096" }, { "db": "NVD", "id": "CVE-2022-42166" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNNVD", "id": "CNNVD-202210-1096" }, { "db": "NVD", "id": "CVE-2022-42166" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1096" }, { "date": "2022-10-17T14:15:13.900000", "db": "NVD", "id": "CVE-2022-42166" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1096" }, { "date": "2022-10-19T15:07:46.993000", "db": "NVD", "id": "CVE-2022-42166" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1096" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1096" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1096" } ], "trust": 0.6 } }
var-202403-0820
Vulnerability from variot
A vulnerability has been found in Tenda AC10U 15.03.06.49 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257458 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda AC10 is a wireless router from China's Tenda company. The vulnerability is caused by the mac parameter of the formWriteFacMac function of the /goform/WriteFacMac file failing to properly filter special characters and commands in the constructed command. Attackers can exploit this vulnerability to cause arbitrary command execution
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0820", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "15.03.06.49" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-15743" } ] }, "cve": "CVE-2024-2707", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2024-2707", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CNVD-2024-15743", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.8, "id": "CVE-2024-2707", "impactScore": 3.4, "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-2707", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNVD", "id": "CNVD-2024-15743", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-15743" }, { "db": "NVD", "id": "CVE-2024-2707" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been found in Tenda AC10U 15.03.06.49 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257458 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda AC10 is a wireless router from China\u0027s Tenda company. The vulnerability is caused by the mac parameter of the formWriteFacMac function of the /goform/WriteFacMac file failing to properly filter special characters and commands in the constructed command. Attackers can exploit this vulnerability to cause arbitrary command execution", "sources": [ { "db": "NVD", "id": "CVE-2024-2707" }, { "db": "CNVD", "id": "CNVD-2024-15743" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "VULDB", "id": "257458", "trust": 1.6 }, { "db": "NVD", "id": "CVE-2024-2707", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2024-15743", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-15743" }, { "db": "NVD", "id": "CVE-2024-2707" } ] }, "id": "VAR-202403-0820", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-15743" } ], "trust": 0.86649562 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-15743" } ] }, "last_update_date": "2024-08-14T14:16:39.803000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda AC10 operating system command injection vulnerability (CNVD-2024-15743)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/537791" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-15743" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-78", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-2707" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://vuldb.com/?id.257458" }, { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac10u/v1.v15.03.06.49/more/formwritefacmac.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.257458" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-15743" }, { "db": "NVD", "id": "CVE-2024-2707" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-15743" }, { "db": "NVD", "id": "CVE-2024-2707" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-03-29T00:00:00", "db": "CNVD", "id": "CNVD-2024-15743" }, { "date": "2024-03-20T17:15:08.243000", "db": "NVD", "id": "CVE-2024-2707" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-04-01T00:00:00", "db": "CNVD", "id": "CNVD-2024-15743" }, { "date": "2024-05-17T02:38:26.230000", "db": "NVD", "id": "CVE-2024-2707" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 operating system command injection vulnerability (CNVD-2024-15743)", "sources": [ { "db": "CNVD", "id": "CNVD-2024-15743" } ], "trust": 0.6 } }
var-202311-2305
Vulnerability from variot
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the time parameter in the function compare_parentcontrol_time. Tenda AC10 is a wireless router made by China Tenda Company. This vulnerability is caused by the time parameter of the compare_parentcontrol_time function failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause Denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202311-2305", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac10 us ac10v4.0si v16.03.10.13 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98204" }, { "db": "NVD", "id": "CVE-2023-45483" } ] }, "cve": "CVE-2023-45483", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-98204", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-45483", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-45483", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2023-98204", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98204" }, { "db": "NVD", "id": "CVE-2023-45483" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the time parameter in the function compare_parentcontrol_time. Tenda AC10 is a wireless router made by China Tenda Company. This vulnerability is caused by the time parameter of the compare_parentcontrol_time function failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause Denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2023-45483" }, { "db": "CNVD", "id": "CNVD-2023-98204" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-45483", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2023-98204", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98204" }, { "db": "NVD", "id": "CVE-2023-45483" } ] }, "id": "VAR-202311-2305", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-98204" } ], "trust": 0.86649562 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98204" } ] }, "last_update_date": "2024-08-14T14:09:39.826000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda AC10 compare_parentcontrol_time function buffer overflow vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/503151" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98204" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-45483" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://github.com/l3m0nade/iotvul/blob/master/assets/compare_parentcontrol_time_code.png" }, { "trust": 1.0, "url": "https://github.com/l3m0nade/iotvul/blob/master/compare_parentcontrol_time.md" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98204" }, { "db": "NVD", "id": "CVE-2023-45483" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-98204" }, { "db": "NVD", "id": "CVE-2023-45483" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-98204" }, { "date": "2023-11-29T06:15:46.760000", "db": "NVD", "id": "CVE-2023-45483" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-18T00:00:00", "db": "CNVD", "id": "CNVD-2023-98204" }, { "date": "2023-12-01T03:57:22.423000", "db": "NVD", "id": "CVE-2023-45483" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 compare_parentcontrol_time function buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2023-98204" } ], "trust": 0.6 } }
var-202304-0769
Vulnerability from variot
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0769", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13_cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.13 cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006753" }, { "db": "NVD", "id": "CVE-2023-27021" } ] }, "cve": "CVE-2023-27021", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-27021", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-27021", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-27021", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-27021", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202304-481", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006753" }, { "db": "CNNVD", "id": "CNNVD-202304-481" }, { "db": "NVD", "id": "CVE-2023-27021" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-27021" }, { "db": "JVNDB", "id": "JVNDB-2023-006753" }, { "db": "VULMON", "id": "CVE-2023-27021" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-27021", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006753", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-481", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-27021", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27021" }, { "db": "JVNDB", "id": "JVNDB-2023-006753" }, { "db": "CNNVD", "id": "CNNVD-202304-481" }, { "db": "NVD", "id": "CVE-2023-27021" } ] }, "id": "VAR-202304-0769", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T15:05:45.580000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006753" }, { "db": "NVD", "id": "CVE-2023-27021" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac10/9/9.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-27021" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-27021/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27021" }, { "db": "JVNDB", "id": "JVNDB-2023-006753" }, { "db": "CNNVD", "id": "CNNVD-202304-481" }, { "db": "NVD", "id": "CVE-2023-27021" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-27021" }, { "db": "JVNDB", "id": "JVNDB-2023-006753" }, { "db": "CNNVD", "id": "CNNVD-202304-481" }, { "db": "NVD", "id": "CVE-2023-27021" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27021" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006753" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-481" }, { "date": "2023-04-07T02:15:08.540000", "db": "NVD", "id": "CVE-2023-27021" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27021" }, { "date": "2023-11-16T04:53:00", "db": "JVNDB", "id": "JVNDB-2023-006753" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-481" }, { "date": "2023-04-12T19:13:23.657000", "db": "NVD", "id": "CVE-2023-27021" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-481" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006753" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-481" } ], "trust": 0.6 } }
var-202308-4145
Vulnerability from variot
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4145", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.44" }, { "model": "ac6", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac8", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.34.06" }, { "model": "f1203", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.1.6" }, { "model": "fh1203", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.1.6" }, { "model": "ac1206", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "fh1203", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac6", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "f1203", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac8", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "db": "NVD", "id": "CVE-2023-38931" } ] }, "cve": "CVE-2023-38931", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-38931", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-38931", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-38931", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-38931", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "db": "NVD", "id": "CVE-2023-38931" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-38931" }, { "db": "JVNDB", "id": "JVNDB-2023-021662" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-38931", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-021662", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "db": "NVD", "id": "CVE-2023-38931" } ] }, "id": "VAR-202308-4145", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.29234484666666666 }, "last_update_date": "2024-08-14T14:23:50.165000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "db": "NVD", "id": "CVE-2023-38931" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/cloudv2_setaccount/readme.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38931" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "db": "NVD", "id": "CVE-2023-38931" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "db": "NVD", "id": "CVE-2023-38931" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "date": "2023-08-07T19:15:10.977000", "db": "NVD", "id": "CVE-2023-38931" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T07:51:00", "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "date": "2023-08-10T17:17:05.110000", "db": "NVD", "id": "CVE-2023-38931" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021662" } ], "trust": 0.8 } }
var-202311-2358
Vulnerability from variot
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGuestBasic. Tenda AC10 is a wireless router made by China Tenda Company.
Tenda AC10 has a buffer overflow vulnerability. This vulnerability is caused by the failure of the shareSpeed parameter of the fromSetWifiGuestBasic function to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202311-2358", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac10", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v4.0v16.03.10.13" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06275" }, { "db": "NVD", "id": "CVE-2023-45484" } ] }, "cve": "CVE-2023-45484", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2024-06275", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-45484", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-45484", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2024-06275", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06275" }, { "db": "NVD", "id": "CVE-2023-45484" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGuestBasic. Tenda AC10 is a wireless router made by China Tenda Company. \n\r\n\r\nTenda AC10 has a buffer overflow vulnerability. This vulnerability is caused by the failure of the shareSpeed \u200b\u200bparameter of the fromSetWifiGuestBasic function to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2023-45484" }, { "db": "CNVD", "id": "CNVD-2024-06275" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-45484", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2024-06275", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06275" }, { "db": "NVD", "id": "CVE-2023-45484" } ] }, "id": "VAR-202311-2358", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-06275" } ], "trust": 0.86649562 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06275" } ] }, "last_update_date": "2024-08-14T14:23:43.665000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda AC10 fromSetWifiGuestBasic function buffer overflow vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/521571" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06275" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-45484" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://github.com/l3m0nade/iotvul/blob/master/assets/fromsetwifiguestbasic_code.png" }, { "trust": 1.0, "url": "https://github.com/l3m0nade/iotvul/blob/master/fromsetwifigusetbasic.md" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06275" }, { "db": "NVD", "id": "CVE-2023-45484" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-06275" }, { "db": "NVD", "id": "CVE-2023-45484" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-25T00:00:00", "db": "CNVD", "id": "CNVD-2024-06275" }, { "date": "2023-11-29T06:15:46.810000", "db": "NVD", "id": "CVE-2023-45484" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-29T00:00:00", "db": "CNVD", "id": "CNVD-2024-06275" }, { "date": "2023-12-01T03:56:31.783000", "db": "NVD", "id": "CVE-2023-45484" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 fromSetWifiGuestBasic function buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-06275" } ], "trust": 0.6 } }
var-202308-4213
Vulnerability from variot
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4213", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.42_multi" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.44" }, { "model": "ac8", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.34.06" }, { "model": "ac6", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac1206", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac6", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac8", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "db": "NVD", "id": "CVE-2023-38937" } ] }, "cve": "CVE-2023-38937", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-38937", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-38937", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-38937", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-38937", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "db": "NVD", "id": "CVE-2023-38937" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-38937" }, { "db": "JVNDB", "id": "JVNDB-2023-021658" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-38937", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-021658", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "db": "NVD", "id": "CVE-2023-38937" } ] }, "id": "VAR-202308-4213", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3871988366666666 }, "last_update_date": "2024-08-14T15:26:26.130000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "db": "NVD", "id": "CVE-2023-38937" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetvirtualser/readme.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38937" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "db": "NVD", "id": "CVE-2023-38937" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "db": "NVD", "id": "CVE-2023-38937" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "date": "2023-08-07T19:15:11.413000", "db": "NVD", "id": "CVE-2023-38937" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T07:51:00", "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "date": "2023-08-10T18:22:01.703000", "db": "NVD", "id": "CVE-2023-38937" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021658" } ], "trust": 0.8 } }
var-202306-0870
Vulnerability from variot
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo.
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202306-0870", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "us_ac10v4.0si_v16.03.10.13_cn" } ], "sources": [ { "db": "NVD", "id": "CVE-2023-34566" } ] }, "cve": "CVE-2023-34566", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-34566", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-34566", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202306-622", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-622" }, { "db": "NVD", "id": "CVE-2023-34566" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo.", "sources": [ { "db": "NVD", "id": "CVE-2023-34566" } ], "trust": 1.0 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-34566", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202306-622", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-34566", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-34566" }, { "db": "CNNVD", "id": "CNNVD-202306-622" }, { "db": "NVD", "id": "CVE-2023-34566" } ] }, "id": "VAR-202306-0870", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T15:05:36.866000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-34566" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://hackmd.io/%400dayresearch/rk8hqf5rh" }, { "trust": 0.7, "url": "https://hackmd.io/@0dayresearch/rk8hqf5rh" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-34566/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-34566" }, { "db": "CNNVD", "id": "CNNVD-202306-622" }, { "db": "NVD", "id": "CVE-2023-34566" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-34566" }, { "db": "CNNVD", "id": "CNNVD-202306-622" }, { "db": "NVD", "id": "CVE-2023-34566" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-08T00:00:00", "db": "VULMON", "id": "CVE-2023-34566" }, { "date": "2023-06-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202306-622" }, { "date": "2023-06-08T15:15:09.560000", "db": "NVD", "id": "CVE-2023-34566" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-08T00:00:00", "db": "VULMON", "id": "CVE-2023-34566" }, { "date": "2023-06-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202306-622" }, { "date": "2023-11-07T04:15:38.510000", "db": "NVD", "id": "CVE-2023-34566" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-622" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-622" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-622" } ], "trust": 0.6 } }
var-201809-0930
Vulnerability from variot
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server. While processing the ssid parameter for a POST request, the value is directly used in a sprintf call to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow. plural Tenda Product Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7, etc. are all wireless router products of China Tenda. An attacker can use this vulnerability to cause a denial of service. The following products and versions are affected: Tenda AC7 15.03.06.44_CN Version; AC9 15.03.05.19(6318)_CN Version; AC10 15.03.06.23_CN Version; AC15 15.03.05.19_CN Version; AC18 15.03.05.19(6318)_CN Version
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0930", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.6, "vendor": "tendacn", "version": "15.03.06.23" }, { "model": "ac15", "scope": "eq", "trust": 1.6, "vendor": "tendacn", "version": "15.03.05.19" }, { "model": "ac9", "scope": "eq", "trust": 1.6, "vendor": "tendacn", "version": "15.03.05.19" }, { "model": "ac7", "scope": "eq", "trust": 1.6, "vendor": "tendacn", "version": "15.03.06.44" }, { "model": "ac18", "scope": "lte", "trust": 1.0, "vendor": "tendacn", "version": "15.03.05.19" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac15", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19_cn" }, { "model": "ac18", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac7", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac9", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac9 15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac7 15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac15 15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac18 15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac18", "scope": "eq", "trust": 0.6, "vendor": "tendacn", "version": "15.03.05.19" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-35175" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "db": "CNNVD", "id": "CNNVD-201809-036" }, { "db": "NVD", "id": "CVE-2018-16333" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tendacn:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac15_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac18_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-009403" } ] }, "cve": "CVE-2018-16333", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-16333", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2020-35175", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-126682", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-16333", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-16333", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-16333", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2020-35175", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201809-036", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-126682", "trust": 0.1, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2018-16333", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-35175" }, { "db": "VULHUB", "id": "VHN-126682" }, { "db": "VULMON", "id": "CVE-2018-16333" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "db": "CNNVD", "id": "CNNVD-201809-036" }, { "db": "NVD", "id": "CVE-2018-16333" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server. While processing the ssid parameter for a POST request, the value is directly used in a sprintf call to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow. plural Tenda Product Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7, etc. are all wireless router products of China Tenda. An attacker can use this vulnerability to cause a denial of service. The following products and versions are affected: Tenda AC7 15.03.06.44_CN Version; AC9 15.03.05.19(6318)_CN Version; AC10 15.03.06.23_CN Version; AC15 15.03.05.19_CN Version; AC18 15.03.05.19(6318)_CN Version", "sources": [ { "db": "NVD", "id": "CVE-2018-16333" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "db": "CNVD", "id": "CNVD-2020-35175" }, { "db": "VULHUB", "id": "VHN-126682" }, { "db": "VULMON", "id": "CVE-2018-16333" } ], "trust": 2.34 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-16333", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2018-009403", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201809-036", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2020-35175", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-126682", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2018-16333", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-35175" }, { "db": "VULHUB", "id": "VHN-126682" }, { "db": "VULMON", "id": "CVE-2018-16333" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "db": "CNNVD", "id": "CNNVD-201809-036" }, { "db": "NVD", "id": "CVE-2018-16333" } ] }, "id": "VAR-201809-0930", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-35175" }, { "db": "VULHUB", "id": "VHN-126682" } ], "trust": 1.4236169144444446 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-35175" } ] }, "last_update_date": "2024-11-23T22:38:03.789000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" }, { "title": "", "trust": 0.1, "url": "https://github.com/kal1x/iotvulhub " }, { "title": "Routers", "trust": 0.1, "url": "https://github.com/ZIllR0/Routers " } ], "sources": [ { "db": "VULMON", "id": "CVE-2018-16333" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-126682" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "db": "NVD", "id": "CVE-2018-16333" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.6, "url": "https://github.com/zillr0/routers/blob/master/tenda/oob1.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-16333" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-16333" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/119.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://github.com/kal1x/iotvulhub" }, { "trust": 0.1, "url": "https://github.com/zillr0/routers" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-35175" }, { "db": "VULHUB", "id": "VHN-126682" }, { "db": "VULMON", "id": "CVE-2018-16333" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "db": "CNNVD", "id": "CNNVD-201809-036" }, { "db": "NVD", "id": "CVE-2018-16333" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-35175" }, { "db": "VULHUB", "id": "VHN-126682" }, { "db": "VULMON", "id": "CVE-2018-16333" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "db": "CNNVD", "id": "CNNVD-201809-036" }, { "db": "NVD", "id": "CVE-2018-16333" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-30T00:00:00", "db": "CNVD", "id": "CNVD-2020-35175" }, { "date": "2018-09-02T00:00:00", "db": "VULHUB", "id": "VHN-126682" }, { "date": "2018-09-02T00:00:00", "db": "VULMON", "id": "CVE-2018-16333" }, { "date": "2018-11-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "date": "2018-09-03T00:00:00", "db": "CNNVD", "id": "CNNVD-201809-036" }, { "date": "2018-09-02T03:29:00.620000", "db": "NVD", "id": "CVE-2018-16333" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-30T00:00:00", "db": "CNVD", "id": "CNVD-2020-35175" }, { "date": "2018-10-25T00:00:00", "db": "VULHUB", "id": "VHN-126682" }, { "date": "2018-10-25T00:00:00", "db": "VULMON", "id": "CVE-2018-16333" }, { "date": "2018-11-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "date": "2018-09-03T00:00:00", "db": "CNNVD", "id": "CNNVD-201809-036" }, { "date": "2024-11-21T03:52:32.530000", "db": "NVD", "id": "CVE-2018-16333" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201809-036" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Product buffer error vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-009403" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer overflow", "sources": [ { "db": "CNNVD", "id": "CNNVD-201809-036" } ], "trust": 0.6 } }
var-202304-0655
Vulnerability from variot
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_4A75C0 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0655", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13_cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.13 cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006851" }, { "db": "NVD", "id": "CVE-2023-27015" } ] }, "cve": "CVE-2023-27015", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-27015", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-27015", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-27015", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-27015", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202304-488", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006851" }, { "db": "CNNVD", "id": "CNNVD-202304-488" }, { "db": "NVD", "id": "CVE-2023-27015" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_4A75C0 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-27015" }, { "db": "JVNDB", "id": "JVNDB-2023-006851" }, { "db": "VULMON", "id": "CVE-2023-27015" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-27015", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006851", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-488", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-27015", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27015" }, { "db": "JVNDB", "id": "JVNDB-2023-006851" }, { "db": "CNNVD", "id": "CNNVD-202304-488" }, { "db": "NVD", "id": "CVE-2023-27015" } ] }, "id": "VAR-202304-0655", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T13:20:53.240000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006851" }, { "db": "NVD", "id": "CVE-2023-27015" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac10/4/4.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-27015" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-27015/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27015" }, { "db": "JVNDB", "id": "JVNDB-2023-006851" }, { "db": "CNNVD", "id": "CNNVD-202304-488" }, { "db": "NVD", "id": "CVE-2023-27015" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-27015" }, { "db": "JVNDB", "id": "JVNDB-2023-006851" }, { "db": "CNNVD", "id": "CNNVD-202304-488" }, { "db": "NVD", "id": "CVE-2023-27015" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27015" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006851" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-488" }, { "date": "2023-04-07T02:15:08.323000", "db": "NVD", "id": "CVE-2023-27015" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27015" }, { "date": "2023-11-16T07:01:00", "db": "JVNDB", "id": "JVNDB-2023-006851" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-488" }, { "date": "2023-04-13T18:03:46.810000", "db": "NVD", "id": "CVE-2023-27015" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-488" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006851" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-488" } ], "trust": 0.6 } }
var-202411-0498
Vulnerability from variot
A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC10 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202411-0498", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.13" }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-012663" }, { "db": "NVD", "id": "CVE-2024-11061" } ] }, "cve": "CVE-2024-11061", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CVE-2024-11061", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.0, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "OTHER", "availabilityImpact": "Complete", "baseScore": 9.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "JVNDB-2024-012663", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2024-11061", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2024-012663", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-11061", "trust": 1.0, "value": "High" }, { "author": "nvd@nist.gov", "id": "CVE-2024-11061", "trust": 1.0, "value": "HIGH" }, { "author": "OTHER", "id": "JVNDB-2024-012663", "trust": 0.8, "value": "High" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-012663" }, { "db": "NVD", "id": "CVE-2024-11061" }, { "db": "NVD", "id": "CVE-2024-11061" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC10 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2024-11061" }, { "db": "JVNDB", "id": "JVNDB-2024-012663" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-11061", "trust": 2.6 }, { "db": "VULDB", "id": "283807", "trust": 1.0 }, { "db": "JVNDB", "id": "JVNDB-2024-012663", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-012663" }, { "db": "NVD", "id": "CVE-2024-11061" } ] }, "id": "VAR-202411-0498", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-11-16T23:06:18.334000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.0 }, { "problemtype": "CWE-121", "trust": 1.0 }, { "problemtype": "Buffer error (CWE-119) [ others ]", "trust": 0.8 }, { "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-012663" }, { "db": "NVD", "id": "CVE-2024-11061" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://tasty-foxtrot-3a8.notion.site/tenda-ac10v4-fun_0044db3c-stack-overflow-13a0448e619580ae96fee2899545e159" }, { "trust": 1.8, "url": "https://vuldb.com/?submit.440825" }, { "trust": 1.8, "url": "https://www.tenda.com.cn/" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.283807" }, { "trust": 1.0, "url": "https://vuldb.com/?id.283807" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-11061" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-012663" }, { "db": "NVD", "id": "CVE-2024-11061" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2024-012663" }, { "db": "NVD", "id": "CVE-2024-11061" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-11-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2024-012663" }, { "date": "2024-11-11T01:15:04.523000", "db": "NVD", "id": "CVE-2024-11061" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-11-15T02:32:00", "db": "JVNDB", "id": "JVNDB-2024-012663" }, { "date": "2024-11-13T23:04:25.633000", "db": "NVD", "id": "CVE-2024-11061" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Buffer error vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-012663" } ], "trust": 0.8 } }
var-202306-0820
Vulnerability from variot
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter devName at /goform/SetOnlineDevName.
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202306-0820", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "us_ac10v4.0si_v16.03.10.13_cn" } ], "sources": [ { "db": "NVD", "id": "CVE-2023-34570" } ] }, "cve": "CVE-2023-34570", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "id": "CVE-2023-34570", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-34570", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202306-619", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-619" }, { "db": "NVD", "id": "CVE-2023-34570" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter devName at /goform/SetOnlineDevName.", "sources": [ { "db": "NVD", "id": "CVE-2023-34570" } ], "trust": 1.0 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-34570", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202306-619", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-34570", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-34570" }, { "db": "CNNVD", "id": "CNNVD-202306-619" }, { "db": "NVD", "id": "CVE-2023-34570" } ] }, "id": "VAR-202306-0820", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T15:36:55.806000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-34570" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://hackmd.io/%400dayresearch/s1ei91_l2" }, { "trust": 0.7, "url": "https://hackmd.io/@0dayresearch/s1ei91_l2" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-34570/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-34570" }, { "db": "CNNVD", "id": "CNNVD-202306-619" }, { "db": "NVD", "id": "CVE-2023-34570" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-34570" }, { "db": "CNNVD", "id": "CNNVD-202306-619" }, { "db": "NVD", "id": "CVE-2023-34570" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-08T00:00:00", "db": "VULMON", "id": "CVE-2023-34570" }, { "date": "2023-06-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202306-619" }, { "date": "2023-06-08T15:15:09.747000", "db": "NVD", "id": "CVE-2023-34570" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-08T00:00:00", "db": "VULMON", "id": "CVE-2023-34570" }, { "date": "2023-06-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202306-619" }, { "date": "2023-11-07T04:15:42.333000", "db": "NVD", "id": "CVE-2023-34570" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-619" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-619" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-619" } ], "trust": 0.6 } }
var-202307-1306
Vulnerability from variot
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202307-1306", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "f1202", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0br" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "3.0" }, { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" }, { "model": "f1202", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.2.0.20\\(408\\)" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" }, { "model": "fh1202", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.2.0.19_en" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" } ], "sources": [ { "db": "NVD", "id": "CVE-2023-37716" } ] }, "cve": "CVE-2023-37716", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-37716", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-37716", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202307-1255", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1255" }, { "db": "NVD", "id": "CVE-2023-37716" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting", "sources": [ { "db": "NVD", "id": "CVE-2023-37716" }, { "db": "VULMON", "id": "CVE-2023-37716" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-37716", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202307-1255", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-37716", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-37716" }, { "db": "CNNVD", "id": "CNNVD-202307-1255" }, { "db": "NVD", "id": "CVE-2023-37716" } ] }, "id": "VAR-202307-1306", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.5256526420000001 }, "last_update_date": "2024-08-14T14:09:54.108000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-37716" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromnatstaticsetting/report.md" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-37716/" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37716" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-37716" }, { "db": "CNNVD", "id": "CNNVD-202307-1255" }, { "db": "NVD", "id": "CVE-2023-37716" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-37716" }, { "db": "CNNVD", "id": "CNNVD-202307-1255" }, { "db": "NVD", "id": "CVE-2023-37716" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-14T00:00:00", "db": "VULMON", "id": "CVE-2023-37716" }, { "date": "2023-07-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-1255" }, { "date": "2023-07-14T00:15:09.430000", "db": "NVD", "id": "CVE-2023-37716" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-14T00:00:00", "db": "VULMON", "id": "CVE-2023-37716" }, { "date": "2023-07-24T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-1255" }, { "date": "2023-07-21T14:33:30.690000", "db": "NVD", "id": "CVE-2023-37716" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1255" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda F1202 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1255" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1255" } ], "trust": 0.6 } }
var-202309-0777
Vulnerability from variot
Buffer Overflow vulnerability in Tenda AC10V4 v.US_AC10V4.0si_V16.03.10.13_cn_TDC01 allows a remote attacker to cause a denial of service via the mac parameter in the GetParentControlInfo function. Shenzhen Tenda Technology Co.,Ltd. of AC10 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202309-0777", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.13" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-012756" }, { "db": "NVD", "id": "CVE-2023-42320" } ] }, "cve": "CVE-2023-42320", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-42320", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-42320", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-42320", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-42320", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-012756" }, { "db": "NVD", "id": "CVE-2023-42320" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Buffer Overflow vulnerability in Tenda AC10V4 v.US_AC10V4.0si_V16.03.10.13_cn_TDC01 allows a remote attacker to cause a denial of service via the mac parameter in the GetParentControlInfo function. Shenzhen Tenda Technology Co.,Ltd. of AC10 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-42320" }, { "db": "JVNDB", "id": "JVNDB-2023-012756" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-42320", "trust": 2.7 }, { "db": "JVNDB", "id": "JVNDB-2023-012756", "trust": 0.8 }, { "db": "VULMON", "id": "CVE-2023-42320", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-42320" }, { "db": "JVNDB", "id": "JVNDB-2023-012756" }, { "db": "NVD", "id": "CVE-2023-42320" } ] }, "id": "VAR-202309-0777", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T14:01:37.365000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "", "trust": 0.1, "url": "https://github.com/aixiao0621/Tenda " } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-42320" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.0 }, { "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-012756" }, { "db": "NVD", "id": "CVE-2023-42320" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/aixiao0621/tenda/blob/main/ac10/0.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-42320" }, { "trust": 0.1, "url": "https://github.com/aixiao0621/tenda" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-42320" }, { "db": "JVNDB", "id": "JVNDB-2023-012756" }, { "db": "NVD", "id": "CVE-2023-42320" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-42320" }, { "db": "JVNDB", "id": "JVNDB-2023-012756" }, { "db": "NVD", "id": "CVE-2023-42320" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-012756" }, { "date": "2023-09-18T16:15:45.797000", "db": "NVD", "id": "CVE-2023-42320" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-19T01:13:00", "db": "JVNDB", "id": "JVNDB-2023-012756" }, { "date": "2023-09-21T17:37:44.687000", "db": "NVD", "id": "CVE-2023-42320" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Classic buffer overflow vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-012756" } ], "trust": 0.8 } }
var-201810-0245
Vulnerability from variot
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromAddressNat" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. An attacker could exploit the vulnerability to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0245", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac15", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.05.19_cn" }, { "model": "ac7", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac9", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac9", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac7 v15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac9 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 v15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac15 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac18 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-22313" }, { "db": "JVNDB", "id": "JVNDB-2018-011967" }, { "db": "CNNVD", "id": "CNNVD-201810-1339" }, { "db": "NVD", "id": "CVE-2018-18708" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tenda:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac15_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac18_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011967" } ] }, "cve": "CVE-2018-18708", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-18708", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2018-22313", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-129294", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-18708", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-18708", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-18708", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2018-22313", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201810-1339", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-129294", "trust": 0.1, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2018-18708", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-22313" }, { "db": "VULHUB", "id": "VHN-129294" }, { "db": "VULMON", "id": "CVE-2018-18708" }, { "db": "JVNDB", "id": "JVNDB-2018-011967" }, { "db": "CNNVD", "id": "CNNVD-201810-1339" }, { "db": "NVD", "id": "CVE-2018-18708" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. An attacker could exploit the vulnerability to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version", "sources": [ { "db": "NVD", "id": "CVE-2018-18708" }, { "db": "JVNDB", "id": "JVNDB-2018-011967" }, { "db": "CNVD", "id": "CNVD-2018-22313" }, { "db": "VULHUB", "id": "VHN-129294" }, { "db": "VULMON", "id": "CVE-2018-18708" } ], "trust": 2.34 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-18708", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2018-011967", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201810-1339", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2018-22313", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-129294", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2018-18708", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-22313" }, { "db": "VULHUB", "id": "VHN-129294" }, { "db": "VULMON", "id": "CVE-2018-18708" }, { "db": "JVNDB", "id": "JVNDB-2018-011967" }, { "db": "CNNVD", "id": "CNNVD-201810-1339" }, { "db": "NVD", "id": "CVE-2018-18708" } ] }, "id": "VAR-201810-0245", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2018-22313" }, { "db": "VULHUB", "id": "VHN-129294" } ], "trust": 1.4236169144444446 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-22313" } ] }, "last_update_date": "2024-11-23T21:38:16.715000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" }, { "title": "", "trust": 0.1, "url": "https://github.com/saber0x0/iot_sec_learn " } ], "sources": [ { "db": "VULMON", "id": "CVE-2018-18708" }, { "db": "JVNDB", "id": "JVNDB-2018-011967" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-129294" }, { "db": "JVNDB", "id": "JVNDB-2018-011967" }, { "db": "NVD", "id": "CVE-2018-18708" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.2, "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/tenda.md" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18708" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18708" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/119.html" }, { "trust": 0.1, "url": "https://github.com/saber0x0/iot_sec_learn" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-22313" }, { "db": "VULHUB", "id": "VHN-129294" }, { "db": "VULMON", "id": "CVE-2018-18708" }, { "db": "JVNDB", "id": "JVNDB-2018-011967" }, { "db": "CNNVD", "id": "CNNVD-201810-1339" }, { "db": "NVD", "id": "CVE-2018-18708" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2018-22313" }, { "db": "VULHUB", "id": "VHN-129294" }, { "db": "VULMON", "id": "CVE-2018-18708" }, { "db": "JVNDB", "id": "JVNDB-2018-011967" }, { "db": "CNNVD", "id": "CNNVD-201810-1339" }, { "db": "NVD", "id": "CVE-2018-18708" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-11-01T00:00:00", "db": "CNVD", "id": "CNVD-2018-22313" }, { "date": "2018-10-29T00:00:00", "db": "VULHUB", "id": "VHN-129294" }, { "date": "2018-10-29T00:00:00", "db": "VULMON", "id": "CVE-2018-18708" }, { "date": "2019-01-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011967" }, { "date": "2018-10-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1339" }, { "date": "2018-10-29T12:29:05.617000", "db": "NVD", "id": "CVE-2018-18708" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-11-01T00:00:00", "db": "CNVD", "id": "CNVD-2018-22313" }, { "date": "2018-12-14T00:00:00", "db": "VULHUB", "id": "VHN-129294" }, { "date": "2018-12-14T00:00:00", "db": "VULMON", "id": "CVE-2018-18708" }, { "date": "2019-01-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011967" }, { "date": "2018-10-31T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1339" }, { "date": "2024-11-21T03:56:25.030000", "db": "NVD", "id": "CVE-2018-18708" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1339" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Product buffer error vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011967" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer overflow", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1339" } ], "trust": 0.6 } }
var-202304-0460
Vulnerability from variot
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_46AC38 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0460", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13_cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.13 cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006852" }, { "db": "NVD", "id": "CVE-2023-27014" } ] }, "cve": "CVE-2023-27014", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-27014", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-27014", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-27014", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-27014", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202304-491", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006852" }, { "db": "CNNVD", "id": "CNNVD-202304-491" }, { "db": "NVD", "id": "CVE-2023-27014" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_46AC38 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-27014" }, { "db": "JVNDB", "id": "JVNDB-2023-006852" }, { "db": "VULMON", "id": "CVE-2023-27014" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-27014", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006852", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-491", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-27014", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27014" }, { "db": "JVNDB", "id": "JVNDB-2023-006852" }, { "db": "CNNVD", "id": "CNNVD-202304-491" }, { "db": "NVD", "id": "CVE-2023-27014" } ] }, "id": "VAR-202304-0460", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T15:26:44.237000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006852" }, { "db": "NVD", "id": "CVE-2023-27014" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac10/10/10.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-27014" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-27014/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27014" }, { "db": "JVNDB", "id": "JVNDB-2023-006852" }, { "db": "CNNVD", "id": "CNNVD-202304-491" }, { "db": "NVD", "id": "CVE-2023-27014" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-27014" }, { "db": "JVNDB", "id": "JVNDB-2023-006852" }, { "db": "CNNVD", "id": "CNNVD-202304-491" }, { "db": "NVD", "id": "CVE-2023-27014" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27014" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006852" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-491" }, { "date": "2023-04-07T02:15:08.287000", "db": "NVD", "id": "CVE-2023-27014" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27014" }, { "date": "2023-11-16T07:02:00", "db": "JVNDB", "id": "JVNDB-2023-006852" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-491" }, { "date": "2023-04-13T18:03:53.177000", "db": "NVD", "id": "CVE-2023-27014" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-491" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006852" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-491" } ], "trust": 0.6 } }
var-202311-2507
Vulnerability from variot
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg. Tenda AC10 is a wireless router made by China Tenda Company.
Tenda AC10 has a buffer overflow vulnerability. This vulnerability is caused by the failure of the firewallEn parameter of the SetFirewallCfg function to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202311-2507", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac10", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v4.0v16.03.10.13" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06276" }, { "db": "NVD", "id": "CVE-2023-45481" } ] }, "cve": "CVE-2023-45481", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2024-06276", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-45481", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-45481", "trust": 1.0, "value": "CRITICAL" }, { "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "id": "CVE-2023-45481", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2024-06276", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06276" }, { "db": "NVD", "id": "CVE-2023-45481" }, { "db": "NVD", "id": "CVE-2023-45481" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg. Tenda AC10 is a wireless router made by China Tenda Company. \n\r\n\r\nTenda AC10 has a buffer overflow vulnerability. This vulnerability is caused by the failure of the firewallEn parameter of the SetFirewallCfg function to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2023-45481" }, { "db": "CNVD", "id": "CNVD-2024-06276" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-45481", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2024-06276", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06276" }, { "db": "NVD", "id": "CVE-2023-45481" } ] }, "id": "VAR-202311-2507", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-06276" } ], "trust": 0.86649562 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06276" } ] }, "last_update_date": "2024-08-14T15:15:42.217000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda AC10 SetFirewallCfg function buffer overflow vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/521566" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06276" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.0 }, { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-45481" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://github.com/l3m0nade/iotvul/blob/master/assets/setfirewallcfg_code.png" }, { "trust": 1.0, "url": "https://github.com/l3m0nade/iotvul/blob/master/setfirewallcfg.md" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-06276" }, { "db": "NVD", "id": "CVE-2023-45481" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-06276" }, { "db": "NVD", "id": "CVE-2023-45481" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-25T00:00:00", "db": "CNVD", "id": "CNVD-2024-06276" }, { "date": "2023-11-29T06:15:46.660000", "db": "NVD", "id": "CVE-2023-45481" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-29T00:00:00", "db": "CNVD", "id": "CNVD-2024-06276" }, { "date": "2024-08-01T13:44:56.787000", "db": "NVD", "id": "CVE-2023-45481" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 SetFirewallCfg function buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-06276" } ], "trust": 0.6 } }
var-202403-0731
Vulnerability from variot
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability. Tenda AC10 is a wireless router from China's Tenda Company. The vulnerability is caused by the parameter list of the fromSetRouteStatic function in the file /goform/SetStaticRouteCfg failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0731", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "16.03.10.13" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-34381" } ] }, "cve": "CVE-2024-2581", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CVE-2024-2581", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.0, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-34381", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2024-2581", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-2581", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-34381", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-34381" }, { "db": "NVD", "id": "CVE-2024-2581" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability. Tenda AC10 is a wireless router from China\u0027s Tenda Company. The vulnerability is caused by the parameter list of the fromSetRouteStatic function in the file /goform/SetStaticRouteCfg failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service", "sources": [ { "db": "NVD", "id": "CVE-2024-2581" }, { "db": "CNVD", "id": "CNVD-2024-34381" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-2581", "trust": 1.6 }, { "db": "VULDB", "id": "257081", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-34381", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-34381" }, { "db": "NVD", "id": "CVE-2024-2581" } ] }, "id": "VAR-202403-0731", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-34381" } ], "trust": 0.86649562 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-34381" } ] }, "last_update_date": "2024-08-15T12:34:48.458000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-2581" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac10/v16.03.10.13/fromsetroutestatic.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.257081" }, { "trust": 1.0, "url": "https://vuldb.com/?id.257081" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2581" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-34381" }, { "db": "NVD", "id": "CVE-2024-2581" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-34381" }, { "db": "NVD", "id": "CVE-2024-2581" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-08-02T00:00:00", "db": "CNVD", "id": "CNVD-2024-34381" }, { "date": "2024-03-18T03:15:06.380000", "db": "NVD", "id": "CVE-2024-2581" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-08-02T00:00:00", "db": "CNVD", "id": "CNVD-2024-34381" }, { "date": "2024-05-17T02:38:20.983000", "db": "NVD", "id": "CVE-2024-2581" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Buffer Overflow Vulnerability (CNVD-2024-34381)", "sources": [ { "db": "CNVD", "id": "CNVD-2024-34381" } ], "trust": 0.6 } }
var-202304-0529
Vulnerability from variot
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45DC58 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0529", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13_cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.13 cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006758" }, { "db": "NVD", "id": "CVE-2023-27017" } ] }, "cve": "CVE-2023-27017", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-27017", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-27017", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-27017", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-27017", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202304-486", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006758" }, { "db": "CNNVD", "id": "CNNVD-202304-486" }, { "db": "NVD", "id": "CVE-2023-27017" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45DC58 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-27017" }, { "db": "JVNDB", "id": "JVNDB-2023-006758" }, { "db": "VULMON", "id": "CVE-2023-27017" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-27017", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006758", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-486", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-27017", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27017" }, { "db": "JVNDB", "id": "JVNDB-2023-006758" }, { "db": "CNNVD", "id": "CNNVD-202304-486" }, { "db": "NVD", "id": "CVE-2023-27017" } ] }, "id": "VAR-202304-0529", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T13:20:53.364000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006758" }, { "db": "NVD", "id": "CVE-2023-27017" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac10/6/6.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-27017" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-27017/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27017" }, { "db": "JVNDB", "id": "JVNDB-2023-006758" }, { "db": "CNNVD", "id": "CNNVD-202304-486" }, { "db": "NVD", "id": "CVE-2023-27017" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-27017" }, { "db": "JVNDB", "id": "JVNDB-2023-006758" }, { "db": "CNNVD", "id": "CNNVD-202304-486" }, { "db": "NVD", "id": "CVE-2023-27017" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27017" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006758" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-486" }, { "date": "2023-04-07T02:15:08.397000", "db": "NVD", "id": "CVE-2023-27017" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27017" }, { "date": "2023-11-16T05:01:00", "db": "JVNDB", "id": "JVNDB-2023-006758" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-486" }, { "date": "2023-04-12T19:08:14.473000", "db": "NVD", "id": "CVE-2023-27017" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-486" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006758" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-486" } ], "trust": 0.6 } }
var-201810-0278
Vulnerability from variot
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'ntpServer' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0278", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.8, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac15", "scope": "eq", "trust": 1.8, "vendor": "tenda", "version": "15.03.05.19_cn" }, { "model": "ac7", "scope": "eq", "trust": 1.8, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac9", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac7 v15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac9 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 v15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac15 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac18 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01883" }, { "db": "JVNDB", "id": "JVNDB-2018-013979" }, { "db": "NVD", "id": "CVE-2018-18732" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tenda:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac15_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac18_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-013979" } ] }, "cve": "CVE-2018-18732", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-18732", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2019-01883", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-129321", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-18732", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-18732", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-18732", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-01883", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201810-1359", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-129321", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01883" }, { "db": "VULHUB", "id": "VHN-129321" }, { "db": "JVNDB", "id": "JVNDB-2018-013979" }, { "db": "CNNVD", "id": "CNNVD-201810-1359" }, { "db": "NVD", "id": "CVE-2018-18732" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version", "sources": [ { "db": "NVD", "id": "CVE-2018-18732" }, { "db": "JVNDB", "id": "JVNDB-2018-013979" }, { "db": "CNVD", "id": "CNVD-2019-01883" }, { "db": "VULHUB", "id": "VHN-129321" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-18732", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2018-013979", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201810-1359", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2019-01883", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-129321", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01883" }, { "db": "VULHUB", "id": "VHN-129321" }, { "db": "JVNDB", "id": "JVNDB-2018-013979" }, { "db": "CNNVD", "id": "CNNVD-201810-1359" }, { "db": "NVD", "id": "CVE-2018-18732" } ] }, "id": "VAR-201810-0278", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2019-01883" }, { "db": "VULHUB", "id": "VHN-129321" } ], "trust": 1.4236169144444446 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01883" } ] }, "last_update_date": "2024-11-23T23:04:57.538000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-013979" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-129321" }, { "db": "JVNDB", "id": "JVNDB-2018-013979" }, { "db": "NVD", "id": "CVE-2018-18732" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/zillr0/routers/blob/master/tenda/stack2.md" }, { "trust": 1.4, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18732" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18732" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01883" }, { "db": "VULHUB", "id": "VHN-129321" }, { "db": "JVNDB", "id": "JVNDB-2018-013979" }, { "db": "CNNVD", "id": "CNNVD-201810-1359" }, { "db": "NVD", "id": "CVE-2018-18732" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2019-01883" }, { "db": "VULHUB", "id": "VHN-129321" }, { "db": "JVNDB", "id": "JVNDB-2018-013979" }, { "db": "CNNVD", "id": "CNNVD-201810-1359" }, { "db": "NVD", "id": "CVE-2018-18732" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-01-18T00:00:00", "db": "CNVD", "id": "CNVD-2019-01883" }, { "date": "2018-10-29T00:00:00", "db": "VULHUB", "id": "VHN-129321" }, { "date": "2019-03-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-013979" }, { "date": "2018-10-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1359" }, { "date": "2018-10-29T12:29:07.960000", "db": "NVD", "id": "CVE-2018-18732" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-01-18T00:00:00", "db": "CNVD", "id": "CNVD-2019-01883" }, { "date": "2019-01-29T00:00:00", "db": "VULHUB", "id": "VHN-129321" }, { "date": "2019-03-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-013979" }, { "date": "2019-04-01T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1359" }, { "date": "2024-11-21T03:56:28.703000", "db": "NVD", "id": "CVE-2018-18732" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1359" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Product buffer error vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-013979" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1359" } ], "trust": 0.6 } }
var-201810-0277
Vulnerability from variot
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceMac' parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0277", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.8, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac15", "scope": "eq", "trust": 1.8, "vendor": "tenda", "version": "15.03.05.19_cn" }, { "model": "ac7", "scope": "eq", "trust": 1.8, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac9", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac7 v15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac9 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 v15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac15 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac18 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01884" }, { "db": "JVNDB", "id": "JVNDB-2018-013980" }, { "db": "NVD", "id": "CVE-2018-18731" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tenda:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac15_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac18_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-013980" } ] }, "cve": "CVE-2018-18731", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-18731", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2019-01884", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-129320", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-18731", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-18731", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-18731", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-01884", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201810-1358", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-129320", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01884" }, { "db": "VULHUB", "id": "VHN-129320" }, { "db": "JVNDB", "id": "JVNDB-2018-013980" }, { "db": "CNNVD", "id": "CNNVD-201810-1358" }, { "db": "NVD", "id": "CVE-2018-18731" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version", "sources": [ { "db": "NVD", "id": "CVE-2018-18731" }, { "db": "JVNDB", "id": "JVNDB-2018-013980" }, { "db": "CNVD", "id": "CNVD-2019-01884" }, { "db": "VULHUB", "id": "VHN-129320" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-18731", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2018-013980", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201810-1358", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2019-01884", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-129320", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01884" }, { "db": "VULHUB", "id": "VHN-129320" }, { "db": "JVNDB", "id": "JVNDB-2018-013980" }, { "db": "CNNVD", "id": "CNNVD-201810-1358" }, { "db": "NVD", "id": "CVE-2018-18731" } ] }, "id": "VAR-201810-0277", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2019-01884" }, { "db": "VULHUB", "id": "VHN-129320" } ], "trust": 1.4236169144444446 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01884" } ] }, "last_update_date": "2024-11-23T21:52:47.617000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-013980" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-129320" }, { "db": "JVNDB", "id": "JVNDB-2018-013980" }, { "db": "NVD", "id": "CVE-2018-18731" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://github.com/zillr0/routers/blob/master/tenda/stack4.md" }, { "trust": 1.4, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18731" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18731" }, { "trust": 0.8, "url": "https://github.com/zillr0/routers/blob/master/tenda/stack2.md" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-01884" }, { "db": "VULHUB", "id": "VHN-129320" }, { "db": "JVNDB", "id": "JVNDB-2018-013980" }, { "db": "CNNVD", "id": "CNNVD-201810-1358" }, { "db": "NVD", "id": "CVE-2018-18731" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2019-01884" }, { "db": "VULHUB", "id": "VHN-129320" }, { "db": "JVNDB", "id": "JVNDB-2018-013980" }, { "db": "CNNVD", "id": "CNNVD-201810-1358" }, { "db": "NVD", "id": "CVE-2018-18731" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-01-18T00:00:00", "db": "CNVD", "id": "CNVD-2019-01884" }, { "date": "2018-10-29T00:00:00", "db": "VULHUB", "id": "VHN-129320" }, { "date": "2019-03-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-013980" }, { "date": "2018-10-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1358" }, { "date": "2018-10-29T12:29:07.837000", "db": "NVD", "id": "CVE-2018-18731" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-01-18T00:00:00", "db": "CNVD", "id": "CNVD-2019-01884" }, { "date": "2019-01-29T00:00:00", "db": "VULHUB", "id": "VHN-129320" }, { "date": "2019-03-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-013980" }, { "date": "2019-04-01T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1358" }, { "date": "2024-11-21T03:56:28.527000", "db": "NVD", "id": "CVE-2018-18731" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1358" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Product buffer error vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-013980" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1358" } ], "trust": 0.6 } }
var-202306-0499
Vulnerability from variot
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet.
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202306-0499", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "us_ac10v4.0si_v16.03.10.13_cn" } ], "sources": [ { "db": "NVD", "id": "CVE-2023-34571" } ] }, "cve": "CVE-2023-34571", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "id": "CVE-2023-34571", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-34571", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202306-618", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-618" }, { "db": "NVD", "id": "CVE-2023-34571" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet.", "sources": [ { "db": "NVD", "id": "CVE-2023-34571" } ], "trust": 1.0 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-34571", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202306-618", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-34571", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-34571" }, { "db": "CNNVD", "id": "CNNVD-202306-618" }, { "db": "NVD", "id": "CVE-2023-34571" } ] }, "id": "VAR-202306-0499", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T14:17:10.191000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-34571" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://hackmd.io/%400dayresearch/s1gcuxzsn" }, { "trust": 0.7, "url": "https://hackmd.io/@0dayresearch/s1gcuxzsn" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-34571/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-34571" }, { "db": "CNNVD", "id": "CNNVD-202306-618" }, { "db": "NVD", "id": "CVE-2023-34571" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-34571" }, { "db": "CNNVD", "id": "CNNVD-202306-618" }, { "db": "NVD", "id": "CVE-2023-34571" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-08T00:00:00", "db": "VULMON", "id": "CVE-2023-34571" }, { "date": "2023-06-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202306-618" }, { "date": "2023-06-08T15:15:09.793000", "db": "NVD", "id": "CVE-2023-34571" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-08T00:00:00", "db": "VULMON", "id": "CVE-2023-34571" }, { "date": "2023-06-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202306-618" }, { "date": "2023-11-07T04:15:43.297000", "db": "NVD", "id": "CVE-2023-34571" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-618" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-618" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-618" } ], "trust": 0.6 } }
var-201810-0244
Vulnerability from variot
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "ssid" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0244", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac15", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.05.19_cn" }, { "model": "ac7", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac9", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac9", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac7 v15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac9 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 v15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac15 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac18 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-09141" }, { "db": "JVNDB", "id": "JVNDB-2018-011966" }, { "db": "CNNVD", "id": "CNNVD-201810-1338" }, { "db": "NVD", "id": "CVE-2018-18707" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tenda:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac15_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac18_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011966" } ] }, "cve": "CVE-2018-18707", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-18707", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2019-09141", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-129293", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-18707", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-18707", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-18707", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-09141", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201810-1338", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-129293", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-09141" }, { "db": "VULHUB", "id": "VHN-129293" }, { "db": "JVNDB", "id": "JVNDB-2018-011966" }, { "db": "CNNVD", "id": "CNNVD-201810-1338" }, { "db": "NVD", "id": "CVE-2018-18707" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version", "sources": [ { "db": "NVD", "id": "CVE-2018-18707" }, { "db": "JVNDB", "id": "JVNDB-2018-011966" }, { "db": "CNVD", "id": "CNVD-2019-09141" }, { "db": "VULHUB", "id": "VHN-129293" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-18707", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2018-011966", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201810-1338", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2019-09141", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-129293", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-09141" }, { "db": "VULHUB", "id": "VHN-129293" }, { "db": "JVNDB", "id": "JVNDB-2018-011966" }, { "db": "CNNVD", "id": "CNNVD-201810-1338" }, { "db": "NVD", "id": "CVE-2018-18707" } ] }, "id": "VAR-201810-0244", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2019-09141" }, { "db": "VULHUB", "id": "VHN-129293" } ], "trust": 1.4236169144444446 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-09141" } ] }, "last_update_date": "2024-11-23T23:12:02.625000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011966" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-129293" }, { "db": "JVNDB", "id": "JVNDB-2018-011966" }, { "db": "NVD", "id": "CVE-2018-18707" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/tenda.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18707" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18707" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-09141" }, { "db": "VULHUB", "id": "VHN-129293" }, { "db": "JVNDB", "id": "JVNDB-2018-011966" }, { "db": "CNNVD", "id": "CNNVD-201810-1338" }, { "db": "NVD", "id": "CVE-2018-18707" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2019-09141" }, { "db": "VULHUB", "id": "VHN-129293" }, { "db": "JVNDB", "id": "JVNDB-2018-011966" }, { "db": "CNNVD", "id": "CNNVD-201810-1338" }, { "db": "NVD", "id": "CVE-2018-18707" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-04-04T00:00:00", "db": "CNVD", "id": "CNVD-2019-09141" }, { "date": "2018-10-29T00:00:00", "db": "VULHUB", "id": "VHN-129293" }, { "date": "2019-01-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011966" }, { "date": "2018-10-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1338" }, { "date": "2018-10-29T12:29:05.507000", "db": "NVD", "id": "CVE-2018-18707" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-04-04T00:00:00", "db": "CNVD", "id": "CNVD-2019-09141" }, { "date": "2018-12-14T00:00:00", "db": "VULHUB", "id": "VHN-129293" }, { "date": "2019-01-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011966" }, { "date": "2018-10-31T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1338" }, { "date": "2024-11-21T03:56:24.870000", "db": "NVD", "id": "CVE-2018-18707" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1338" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Product buffer error vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011966" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer overflow", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1338" } ], "trust": 0.6 } }
var-201810-0977
Vulnerability from variot
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input. Tenda AC7 , AC9 ,and AC10 The firmware contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Tenda AC7, AC9 and AC10 are all wireless router products from China Tenda.
Tenda AC7, AC9 and AC10 have command injection vulnerabilities. The following products and versions are affected: Tenda AC7 (using firmware 15.03.06.44_CN and earlier); AC9 (using firmware 15.03.05.19(6318)_CN and earlier); AC10 (using firmware 15.03.06.23_CN and earlier)
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0977", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "lte", "trust": 1.8, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac7", "scope": "lte", "trust": 1.8, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac9", "scope": "lte", "trust": 1.0, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac9", "scope": "lte", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac7 \u003c=15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 \u003c=15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac9 \u003c=15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-35174" }, { "db": "JVNDB", "id": "JVNDB-2018-013995" }, { "db": "NVD", "id": "CVE-2018-14558" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tenda:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-013995" } ] }, "cve": "CVE-2018-14558", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CVE-2018-14558", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2020-35174", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "VHN-124729", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2018-14558", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-14558", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2018-14558", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2020-35174", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201810-1439", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-124729", "trust": 0.1, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2018-14558", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-35174" }, { "db": "VULHUB", "id": "VHN-124729" }, { "db": "VULMON", "id": "CVE-2018-14558" }, { "db": "JVNDB", "id": "JVNDB-2018-013995" }, { "db": "CNNVD", "id": "CNNVD-201810-1439" }, { "db": "NVD", "id": "CVE-2018-14558" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input. Tenda AC7 , AC9 ,and AC10 The firmware contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Tenda AC7, AC9 and AC10 are all wireless router products from China Tenda. \n\r\n\r\nTenda AC7, AC9 and AC10 have command injection vulnerabilities. The following products and versions are affected: Tenda AC7 (using firmware 15.03.06.44_CN and earlier); AC9 (using firmware 15.03.05.19(6318)_CN and earlier); AC10 (using firmware 15.03.06.23_CN and earlier)", "sources": [ { "db": "NVD", "id": "CVE-2018-14558" }, { "db": "JVNDB", "id": "JVNDB-2018-013995" }, { "db": "CNVD", "id": "CNVD-2020-35174" }, { "db": "VULHUB", "id": "VHN-124729" }, { "db": "VULMON", "id": "CVE-2018-14558" } ], "trust": 2.34 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-14558", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2018-013995", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201810-1439", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2020-35174", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-124729", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2018-14558", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-35174" }, { "db": "VULHUB", "id": "VHN-124729" }, { "db": "VULMON", "id": "CVE-2018-14558" }, { "db": "JVNDB", "id": "JVNDB-2018-013995" }, { "db": "CNNVD", "id": "CNNVD-201810-1439" }, { "db": "NVD", "id": "CVE-2018-14558" } ] }, "id": "VAR-201810-0977", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-35174" }, { "db": "VULHUB", "id": "VHN-124729" } ], "trust": 1.440988034 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-35174" } ] }, "last_update_date": "2024-11-23T22:41:39.731000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-013995" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-78", "trust": 1.1 }, { "problemtype": "CWE-77", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-124729" }, { "db": "JVNDB", "id": "JVNDB-2018-013995" }, { "db": "NVD", "id": "CVE-2018-14558" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.6, "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/tenda.md" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14558" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14558" }, { "trust": 0.6, "url": "http://www.cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14558" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/78.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-35174" }, { "db": "VULHUB", "id": "VHN-124729" }, { "db": "VULMON", "id": "CVE-2018-14558" }, { "db": "JVNDB", "id": "JVNDB-2018-013995" }, { "db": "CNNVD", "id": "CNNVD-201810-1439" }, { "db": "NVD", "id": "CVE-2018-14558" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-35174" }, { "db": "VULHUB", "id": "VHN-124729" }, { "db": "VULMON", "id": "CVE-2018-14558" }, { "db": "JVNDB", "id": "JVNDB-2018-013995" }, { "db": "CNNVD", "id": "CNNVD-201810-1439" }, { "db": "NVD", "id": "CVE-2018-14558" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-30T00:00:00", "db": "CNVD", "id": "CNVD-2020-35174" }, { "date": "2018-10-30T00:00:00", "db": "VULHUB", "id": "VHN-124729" }, { "date": "2018-10-30T00:00:00", "db": "VULMON", "id": "CVE-2018-14558" }, { "date": "2019-03-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-013995" }, { "date": "2018-10-31T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1439" }, { "date": "2018-10-30T18:29:00.580000", "db": "NVD", "id": "CVE-2018-14558" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-30T00:00:00", "db": "CNVD", "id": "CNVD-2020-35174" }, { "date": "2019-10-03T00:00:00", "db": "VULHUB", "id": "VHN-124729" }, { "date": "2019-10-03T00:00:00", "db": "VULMON", "id": "CVE-2018-14558" }, { "date": "2019-03-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-013995" }, { "date": "2019-10-23T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1439" }, { "date": "2024-11-21T03:49:18.470000", "db": "NVD", "id": "CVE-2018-14558" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1439" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Command injection vulnerability in product firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-013995" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1439" } ], "trust": 0.6 } }
var-202203-1492
Vulnerability from variot
Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow via the list parameter in the fromSetIpMacBind function. Tenda AC10-1200 is a wireless router from China Tenda Company. An attacker could exploit this vulnerability to cause the program to crash
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202203-1492", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tendacn", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 15.03.06.23" }, { "model": "ac10-1200 v15.03.06.23 en", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38546" }, { "db": "JVNDB", "id": "JVNDB-2021-018997" }, { "db": "NVD", "id": "CVE-2021-38772" } ] }, "cve": "CVE-2021-38772", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2021-38772", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2022-38546", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2021-38772", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-38772", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-38772", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-38772", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2022-38546", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202203-2039", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38546" }, { "db": "JVNDB", "id": "JVNDB-2021-018997" }, { "db": "CNNVD", "id": "CNNVD-202203-2039" }, { "db": "NVD", "id": "CVE-2021-38772" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow via the list parameter in the fromSetIpMacBind function. Tenda AC10-1200 is a wireless router from China Tenda Company. An attacker could exploit this vulnerability to cause the program to crash", "sources": [ { "db": "NVD", "id": "CVE-2021-38772" }, { "db": "JVNDB", "id": "JVNDB-2021-018997" }, { "db": "CNVD", "id": "CNVD-2022-38546" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-38772", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2021-018997", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-38546", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202203-2039", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38546" }, { "db": "JVNDB", "id": "JVNDB-2021-018997" }, { "db": "CNNVD", "id": "CNNVD-202203-2039" }, { "db": "NVD", "id": "CVE-2021-38772" } ] }, "id": "VAR-202203-1492", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-38546" } ], "trust": 1.23324781 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38546" } ] }, "last_update_date": "2024-08-14T13:22:35.494000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.0 }, { "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-018997" }, { "db": "NVD", "id": "CVE-2021-38772" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://noob3xploiter.medium.com/hacking-the-tenda-ac10-1200-router-part-3-yet-another-buffer-overflow-4eb322f64823" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-38772" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2021-38772/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38546" }, { "db": "JVNDB", "id": "JVNDB-2021-018997" }, { "db": "CNNVD", "id": "CNNVD-202203-2039" }, { "db": "NVD", "id": "CVE-2021-38772" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-38546" }, { "db": "JVNDB", "id": "JVNDB-2021-018997" }, { "db": "CNNVD", "id": "CNNVD-202203-2039" }, { "db": "NVD", "id": "CVE-2021-38772" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2022-38546" }, { "date": "2023-07-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-018997" }, { "date": "2022-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202203-2039" }, { "date": "2022-03-23T19:15:07.873000", "db": "NVD", "id": "CVE-2021-38772" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2022-38546" }, { "date": "2023-07-12T08:30:00", "db": "JVNDB", "id": "JVNDB-2021-018997" }, { "date": "2022-03-28T00:00:00", "db": "CNNVD", "id": "CNNVD-202203-2039" }, { "date": "2022-03-29T19:27:35.500000", "db": "NVD", "id": "CVE-2021-38772" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda\u00a0 of \u00a0AC10\u00a0 Classic buffer overflow vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-018997" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202203-2039" } ], "trust": 0.6 } }
var-201904-0689
Vulnerability from variot
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow. Tenda AC7 , AC9 , AC10 The firmware contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7 and others are all wireless routers from China's Tenda. This vulnerability originates from a network system or product that incorrectly validates data boundaries when performing operations on memory, causing incorrect read and write operations to be associated with other memory locations
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201904-0689", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "lte", "trust": 1.8, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac7", "scope": "lte", "trust": 1.8, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac9", "scope": "lte", "trust": 1.0, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac9", "scope": "lte", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac7 v15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 \u003c=v15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac9 \u003c=v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-13772" }, { "db": "JVNDB", "id": "JVNDB-2018-015358" }, { "db": "NVD", "id": "CVE-2018-14557" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tenda:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-015358" } ] }, "cve": "CVE-2018-14557", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-14557", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2019-13772", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-124728", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-14557", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-14557", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-14557", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-13772", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201904-1169", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-124728", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-13772" }, { "db": "VULHUB", "id": "VHN-124728" }, { "db": "JVNDB", "id": "JVNDB-2018-015358" }, { "db": "CNNVD", "id": "CNNVD-201904-1169" }, { "db": "NVD", "id": "CVE-2018-14557" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow. Tenda AC7 , AC9 , AC10 The firmware contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7 and others are all wireless routers from China\u0027s Tenda. This vulnerability originates from a network system or product that incorrectly validates data boundaries when performing operations on memory, causing incorrect read and write operations to be associated with other memory locations", "sources": [ { "db": "NVD", "id": "CVE-2018-14557" }, { "db": "JVNDB", "id": "JVNDB-2018-015358" }, { "db": "CNVD", "id": "CNVD-2019-13772" }, { "db": "VULHUB", "id": "VHN-124728" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-14557", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2018-015358", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201904-1169", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2019-13772", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-124728", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-13772" }, { "db": "VULHUB", "id": "VHN-124728" }, { "db": "JVNDB", "id": "JVNDB-2018-015358" }, { "db": "CNNVD", "id": "CNNVD-201904-1169" }, { "db": "NVD", "id": "CVE-2018-14557" } ] }, "id": "VAR-201904-0689", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2019-13772" }, { "db": "VULHUB", "id": "VHN-124728" } ], "trust": 1.440988034 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "IoT" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-13772" } ] }, "last_update_date": "2024-11-23T21:52:20.456000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-015358" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-124728" }, { "db": "JVNDB", "id": "JVNDB-2018-015358" }, { "db": "NVD", "id": "CVE-2018-14557" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/tenda.md" }, { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14557" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14557" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-13772" }, { "db": "VULHUB", "id": "VHN-124728" }, { "db": "JVNDB", "id": "JVNDB-2018-015358" }, { "db": "CNNVD", "id": "CNNVD-201904-1169" }, { "db": "NVD", "id": "CVE-2018-14557" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2019-13772" }, { "db": "VULHUB", "id": "VHN-124728" }, { "db": "JVNDB", "id": "JVNDB-2018-015358" }, { "db": "CNNVD", "id": "CNNVD-201904-1169" }, { "db": "NVD", "id": "CVE-2018-14557" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-10T00:00:00", "db": "CNVD", "id": "CNVD-2019-13772" }, { "date": "2019-04-25T00:00:00", "db": "VULHUB", "id": "VHN-124728" }, { "date": "2019-05-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-015358" }, { "date": "2019-04-25T00:00:00", "db": "CNNVD", "id": "CNNVD-201904-1169" }, { "date": "2019-04-25T20:29:00.240000", "db": "NVD", "id": "CVE-2018-14557" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-10T00:00:00", "db": "CNVD", "id": "CNVD-2019-13772" }, { "date": "2019-05-02T00:00:00", "db": "VULHUB", "id": "VHN-124728" }, { "date": "2019-05-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-015358" }, { "date": "2019-04-26T00:00:00", "db": "CNNVD", "id": "CNNVD-201904-1169" }, { "date": "2024-11-21T03:49:18.313000", "db": "NVD", "id": "CVE-2018-14557" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Buffer error vulnerability in product firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-015358" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201904-1169" } ], "trust": 0.6 } }
var-201904-0690
Vulnerability from variot
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow. Tenda AC7 , AC9 , AC10 The firmware contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7 and others are all wireless routers from China's Tenda. This vulnerability originates from a network system or product that incorrectly validates data boundaries when performing operations on memory, causing incorrect read and write operations to be associated with other memory locations
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201904-0690", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "lte", "trust": 1.8, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac7", "scope": "lte", "trust": 1.8, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac9", "scope": "lte", "trust": 1.0, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac9", "scope": "lte", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac7 v15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 \u003c=v15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac9 \u003c=v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-13773" }, { "db": "JVNDB", "id": "JVNDB-2018-015359" }, { "db": "NVD", "id": "CVE-2018-14559" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tenda:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-015359" } ] }, "cve": "CVE-2018-14559", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-14559", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2019-13773", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-124730", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-14559", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-14559", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-14559", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-13773", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201904-1170", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-124730", "trust": 0.1, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2018-14559", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-13773" }, { "db": "VULHUB", "id": "VHN-124730" }, { "db": "VULMON", "id": "CVE-2018-14559" }, { "db": "JVNDB", "id": "JVNDB-2018-015359" }, { "db": "CNNVD", "id": "CNNVD-201904-1170" }, { "db": "NVD", "id": "CVE-2018-14559" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow. Tenda AC7 , AC9 , AC10 The firmware contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7 and others are all wireless routers from China\u0027s Tenda. This vulnerability originates from a network system or product that incorrectly validates data boundaries when performing operations on memory, causing incorrect read and write operations to be associated with other memory locations", "sources": [ { "db": "NVD", "id": "CVE-2018-14559" }, { "db": "JVNDB", "id": "JVNDB-2018-015359" }, { "db": "CNVD", "id": "CNVD-2019-13773" }, { "db": "VULHUB", "id": "VHN-124730" }, { "db": "VULMON", "id": "CVE-2018-14559" } ], "trust": 2.34 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-14559", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2018-015359", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201904-1170", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2019-13773", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-124730", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2018-14559", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-13773" }, { "db": "VULHUB", "id": "VHN-124730" }, { "db": "VULMON", "id": "CVE-2018-14559" }, { "db": "JVNDB", "id": "JVNDB-2018-015359" }, { "db": "CNNVD", "id": "CNNVD-201904-1170" }, { "db": "NVD", "id": "CVE-2018-14559" } ] }, "id": "VAR-201904-0690", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2019-13773" }, { "db": "VULHUB", "id": "VHN-124730" } ], "trust": 1.440988034 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "IoT" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-13773" } ] }, "last_update_date": "2024-11-23T22:17:05.252000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-015359" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-124730" }, { "db": "JVNDB", "id": "JVNDB-2018-015359" }, { "db": "NVD", "id": "CVE-2018-14559" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.2, "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/tenda.md" }, { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14559" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14559" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/119.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-13773" }, { "db": "VULHUB", "id": "VHN-124730" }, { "db": "VULMON", "id": "CVE-2018-14559" }, { "db": "JVNDB", "id": "JVNDB-2018-015359" }, { "db": "CNNVD", "id": "CNNVD-201904-1170" }, { "db": "NVD", "id": "CVE-2018-14559" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2019-13773" }, { "db": "VULHUB", "id": "VHN-124730" }, { "db": "VULMON", "id": "CVE-2018-14559" }, { "db": "JVNDB", "id": "JVNDB-2018-015359" }, { "db": "CNNVD", "id": "CNNVD-201904-1170" }, { "db": "NVD", "id": "CVE-2018-14559" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-10T00:00:00", "db": "CNVD", "id": "CNVD-2019-13773" }, { "date": "2019-04-25T00:00:00", "db": "VULHUB", "id": "VHN-124730" }, { "date": "2019-04-25T00:00:00", "db": "VULMON", "id": "CVE-2018-14559" }, { "date": "2019-05-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-015359" }, { "date": "2019-04-25T00:00:00", "db": "CNNVD", "id": "CNNVD-201904-1170" }, { "date": "2019-04-25T20:29:00.287000", "db": "NVD", "id": "CVE-2018-14559" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-10T00:00:00", "db": "CNVD", "id": "CNVD-2019-13773" }, { "date": "2019-05-02T00:00:00", "db": "VULHUB", "id": "VHN-124730" }, { "date": "2019-05-02T00:00:00", "db": "VULMON", "id": "CVE-2018-14559" }, { "date": "2019-05-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-015359" }, { "date": "2019-04-26T00:00:00", "db": "CNNVD", "id": "CNNVD-201904-1170" }, { "date": "2024-11-21T03:49:18.637000", "db": "NVD", "id": "CVE-2018-14559" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Buffer error vulnerability in product firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-015359" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201904-1170" } ], "trust": 0.6 } }
var-202207-0255
Vulnerability from variot
Tenda AC10 US_AC10V1.0RTL_V15.03.06.26_multi_TD01 was discovered to contain a remote code execution (RCE) vulnerability via the lanIp parameter
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202207-0255", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.26" } ], "sources": [ { "db": "NVD", "id": "CVE-2022-32054" } ] }, "cve": "CVE-2022-32054", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CVE-2022-32054", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.1, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-32054", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-32054", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202207-569", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2022-32054", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-32054" }, { "db": "CNNVD", "id": "CNNVD-202207-569" }, { "db": "NVD", "id": "CVE-2022-32054" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 US_AC10V1.0RTL_V15.03.06.26_multi_TD01 was discovered to contain a remote code execution (RCE) vulnerability via the lanIp parameter", "sources": [ { "db": "NVD", "id": "CVE-2022-32054" }, { "db": "VULMON", "id": "CVE-2022-32054" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-32054", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202207-569", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-32054", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-32054" }, { "db": "CNNVD", "id": "CNNVD-202207-569" }, { "db": "NVD", "id": "CVE-2022-32054" } ] }, "id": "VAR-202207-0255", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T14:55:24.440000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-78", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-32054" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://github.com/winmt/cve/blob/main/tenda%20ac10/readme.md" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-32054/" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/94.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-32054" }, { "db": "CNNVD", "id": "CNNVD-202207-569" }, { "db": "NVD", "id": "CVE-2022-32054" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2022-32054" }, { "db": "CNNVD", "id": "CNNVD-202207-569" }, { "db": "NVD", "id": "CVE-2022-32054" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-07-07T00:00:00", "db": "VULMON", "id": "CVE-2022-32054" }, { "date": "2022-07-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202207-569" }, { "date": "2022-07-07T19:15:08.190000", "db": "NVD", "id": "CVE-2022-32054" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-07-15T00:00:00", "db": "VULMON", "id": "CVE-2022-32054" }, { "date": "2022-08-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202207-569" }, { "date": "2023-08-08T14:21:49.707000", "db": "NVD", "id": "CVE-2022-32054" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202207-569" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Code injection vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202207-569" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "code injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202207-569" } ], "trust": 0.6 } }
var-202210-1170
Vulnerability from variot
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/addWifiMacFilter. Tenda AC10 is a wireless router. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system, or cause a denial of service
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202210-1170", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v15.03.06.23" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-50810" }, { "db": "NVD", "id": "CVE-2022-42169" } ] }, "cve": "CVE-2022-42169", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-50810", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-42169", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-42169", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2023-50810", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202210-1093", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-50810" }, { "db": "CNNVD", "id": "CNNVD-202210-1093" }, { "db": "NVD", "id": "CVE-2022-42169" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/addWifiMacFilter. Tenda AC10 is a wireless router. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system, or cause a denial of service", "sources": [ { "db": "NVD", "id": "CVE-2022-42169" }, { "db": "CNVD", "id": "CNVD-2023-50810" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-42169", "trust": 2.2 }, { "db": "CNVD", "id": "CNVD-2023-50810", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202210-1093", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-50810" }, { "db": "CNNVD", "id": "CNNVD-202210-1093" }, { "db": "NVD", "id": "CVE-2022-42169" } ] }, "id": "VAR-202210-1170", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-50810" } ], "trust": 0.86649562 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-50810" } ] }, "last_update_date": "2024-08-14T14:49:32.278000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42169" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/ac10/addwifimacfilter/readme.md" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-42169" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-42169/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-50810" }, { "db": "CNNVD", "id": "CNNVD-202210-1093" }, { "db": "NVD", "id": "CVE-2022-42169" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-50810" }, { "db": "CNNVD", "id": "CNNVD-202210-1093" }, { "db": "NVD", "id": "CVE-2022-42169" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-25T00:00:00", "db": "CNVD", "id": "CNVD-2023-50810" }, { "date": "2022-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1093" }, { "date": "2022-10-17T14:15:14.077000", "db": "NVD", "id": "CVE-2022-42169" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-25T00:00:00", "db": "CNVD", "id": "CNVD-2023-50810" }, { "date": "2022-10-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1093" }, { "date": "2022-10-19T15:06:49.723000", "db": "NVD", "id": "CVE-2022-42169" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1093" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Stack Buffer Overflow Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2023-50810" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1093" } ], "trust": 0.6 } }
var-202210-1217
Vulnerability from variot
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetFirewallCfg.
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202210-1217", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42167" } ] }, "cve": "CVE-2022-42167", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-42167", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-42167", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202210-1095", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1095" }, { "db": "NVD", "id": "CVE-2022-42167" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetFirewallCfg.", "sources": [ { "db": "NVD", "id": "CVE-2022-42167" } ], "trust": 1.0 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-42167", "trust": 1.6 }, { "db": "CNNVD", "id": "CNNVD-202210-1095", "trust": 0.6 } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1095" }, { "db": "NVD", "id": "CVE-2022-42167" } ] }, "id": "VAR-202210-1217", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T15:11:13.794000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42167" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/ac10/formsetfirewallcfg/readme.md" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-42167/" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1095" }, { "db": "NVD", "id": "CVE-2022-42167" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNNVD", "id": "CNNVD-202210-1095" }, { "db": "NVD", "id": "CVE-2022-42167" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1095" }, { "date": "2022-10-17T14:15:13.963000", "db": "NVD", "id": "CVE-2022-42167" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1095" }, { "date": "2022-10-19T15:07:32.807000", "db": "NVD", "id": "CVE-2022-42167" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1095" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1095" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1095" } ], "trust": 0.6 } }
var-202212-1581
Vulnerability from variot
Tenda AC15 V15.03.06.23 is vulnerable to Buffer Overflow via function formSetClientState. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202212-1581", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 15.03.06.23" }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023707" }, { "db": "NVD", "id": "CVE-2022-46109" } ] }, "cve": "CVE-2022-46109", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2022-46109", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-46109", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-46109", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2022-46109", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202212-3432", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023707" }, { "db": "CNNVD", "id": "CNNVD-202212-3432" }, { "db": "NVD", "id": "CVE-2022-46109" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC15 V15.03.06.23 is vulnerable to Buffer Overflow via function formSetClientState. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2022-46109" }, { "db": "JVNDB", "id": "JVNDB-2022-023707" }, { "db": "VULMON", "id": "CVE-2022-46109" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-46109", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2022-023707", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202212-3432", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-46109", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-46109" }, { "db": "JVNDB", "id": "JVNDB-2022-023707" }, { "db": "CNNVD", "id": "CNNVD-202212-3432" }, { "db": "NVD", "id": "CVE-2022-46109" } ] }, "id": "VAR-202212-1581", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T14:02:11.531000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023707" }, { "db": "NVD", "id": "CVE-2022-46109" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/z1r00/iot_vul/tree/main/tenda/ac10/formsetclientstate" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-46109" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-46109/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-46109" }, { "db": "JVNDB", "id": "JVNDB-2022-023707" }, { "db": "CNNVD", "id": "CNNVD-202212-3432" }, { "db": "NVD", "id": "CVE-2022-46109" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2022-46109" }, { "db": "JVNDB", "id": "JVNDB-2022-023707" }, { "db": "CNNVD", "id": "CNNVD-202212-3432" }, { "db": "NVD", "id": "CVE-2022-46109" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-12-16T00:00:00", "db": "VULMON", "id": "CVE-2022-46109" }, { "date": "2023-11-30T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-023707" }, { "date": "2022-12-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-3432" }, { "date": "2022-12-16T17:15:08.740000", "db": "NVD", "id": "CVE-2022-46109" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-12-16T00:00:00", "db": "VULMON", "id": "CVE-2022-46109" }, { "date": "2023-11-30T00:55:00", "db": "JVNDB", "id": "JVNDB-2022-023707" }, { "date": "2022-12-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-3432" }, { "date": "2022-12-21T20:31:14.953000", "db": "NVD", "id": "CVE-2022-46109" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3432" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023707" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3432" } ], "trust": 0.6 } }
var-201810-0246
Vulnerability from variot
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "firewallEn" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0246", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac15", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.05.19_cn" }, { "model": "ac7", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac9", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac9", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac7 v15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac9 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 v15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac15 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac18 v15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-09142" }, { "db": "JVNDB", "id": "JVNDB-2018-011968" }, { "db": "CNNVD", "id": "CNNVD-201810-1340" }, { "db": "NVD", "id": "CVE-2018-18709" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tenda:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac15_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac18_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011968" } ] }, "cve": "CVE-2018-18709", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-18709", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2019-09142", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-129295", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-18709", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-18709", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-18709", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-09142", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201810-1340", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-129295", "trust": 0.1, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2018-18709", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-09142" }, { "db": "VULHUB", "id": "VHN-129295" }, { "db": "VULMON", "id": "CVE-2018-18709" }, { "db": "JVNDB", "id": "JVNDB-2018-011968" }, { "db": "CNNVD", "id": "CNNVD-201810-1340" }, { "db": "NVD", "id": "CVE-2018-18709" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version", "sources": [ { "db": "NVD", "id": "CVE-2018-18709" }, { "db": "JVNDB", "id": "JVNDB-2018-011968" }, { "db": "CNVD", "id": "CNVD-2019-09142" }, { "db": "VULHUB", "id": "VHN-129295" }, { "db": "VULMON", "id": "CVE-2018-18709" } ], "trust": 2.34 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-18709", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2018-011968", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201810-1340", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2019-09142", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-129295", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2018-18709", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-09142" }, { "db": "VULHUB", "id": "VHN-129295" }, { "db": "VULMON", "id": "CVE-2018-18709" }, { "db": "JVNDB", "id": "JVNDB-2018-011968" }, { "db": "CNNVD", "id": "CNNVD-201810-1340" }, { "db": "NVD", "id": "CVE-2018-18709" } ] }, "id": "VAR-201810-0246", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2019-09142" }, { "db": "VULHUB", "id": "VHN-129295" } ], "trust": 1.4236169144444446 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-09142" } ] }, "last_update_date": "2024-11-23T22:30:16.915000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011968" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-129295" }, { "db": "JVNDB", "id": "JVNDB-2018-011968" }, { "db": "NVD", "id": "CVE-2018-18709" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.6, "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/tenda.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18709" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18709" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/119.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-09142" }, { "db": "VULHUB", "id": "VHN-129295" }, { "db": "VULMON", "id": "CVE-2018-18709" }, { "db": "JVNDB", "id": "JVNDB-2018-011968" }, { "db": "CNNVD", "id": "CNNVD-201810-1340" }, { "db": "NVD", "id": "CVE-2018-18709" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2019-09142" }, { "db": "VULHUB", "id": "VHN-129295" }, { "db": "VULMON", "id": "CVE-2018-18709" }, { "db": "JVNDB", "id": "JVNDB-2018-011968" }, { "db": "CNNVD", "id": "CNNVD-201810-1340" }, { "db": "NVD", "id": "CVE-2018-18709" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-04-04T00:00:00", "db": "CNVD", "id": "CNVD-2019-09142" }, { "date": "2018-10-29T00:00:00", "db": "VULHUB", "id": "VHN-129295" }, { "date": "2018-10-29T00:00:00", "db": "VULMON", "id": "CVE-2018-18709" }, { "date": "2019-01-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011968" }, { "date": "2018-10-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1340" }, { "date": "2018-10-29T12:29:05.727000", "db": "NVD", "id": "CVE-2018-18709" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-04-04T00:00:00", "db": "CNVD", "id": "CNVD-2019-09142" }, { "date": "2018-12-14T00:00:00", "db": "VULHUB", "id": "VHN-129295" }, { "date": "2018-12-14T00:00:00", "db": "VULMON", "id": "CVE-2018-18709" }, { "date": "2019-01-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011968" }, { "date": "2018-10-31T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1340" }, { "date": "2024-11-21T03:56:25.177000", "db": "NVD", "id": "CVE-2018-18709" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1340" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Product buffer error vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011968" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer overflow", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1340" } ], "trust": 0.6 } }
var-202210-1088
Vulnerability from variot
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/fromNatStaticSetting.
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202210-1088", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42163" } ] }, "cve": "CVE-2022-42163", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-42163", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-42163", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202210-1068", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1068" }, { "db": "NVD", "id": "CVE-2022-42163" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/fromNatStaticSetting.", "sources": [ { "db": "NVD", "id": "CVE-2022-42163" } ], "trust": 1.0 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-42163", "trust": 1.6 }, { "db": "CNNVD", "id": "CNNVD-202210-1068", "trust": 0.6 } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1068" }, { "db": "NVD", "id": "CVE-2022-42163" } ] }, "id": "VAR-202210-1088", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T14:17:40.187000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-42163" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/ac10/fromnatstaticsetting/readme.md" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-42163/" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1068" }, { "db": "NVD", "id": "CVE-2022-42163" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNNVD", "id": "CNNVD-202210-1068" }, { "db": "NVD", "id": "CVE-2022-42163" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1068" }, { "date": "2022-10-17T13:15:10.700000", "db": "NVD", "id": "CVE-2022-42163" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-1068" }, { "date": "2022-10-19T15:08:11.040000", "db": "NVD", "id": "CVE-2022-42163" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1068" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1068" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-1068" } ], "trust": 0.6 } }
var-202304-0461
Vulnerability from variot
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_458FBC function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0461", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13_cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 16.03.10.13 cn" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006849" }, { "db": "NVD", "id": "CVE-2023-27019" } ] }, "cve": "CVE-2023-27019", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-27019", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-27019", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-27019", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-27019", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202304-485", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006849" }, { "db": "CNNVD", "id": "CNNVD-202304-485" }, { "db": "NVD", "id": "CVE-2023-27019" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_458FBC function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC10 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-27019" }, { "db": "JVNDB", "id": "JVNDB-2023-006849" }, { "db": "VULMON", "id": "CVE-2023-27019" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-27019", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006849", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-485", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-27019", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27019" }, { "db": "JVNDB", "id": "JVNDB-2023-006849" }, { "db": "CNNVD", "id": "CNNVD-202304-485" }, { "db": "NVD", "id": "CVE-2023-27019" } ] }, "id": "VAR-202304-0461", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26649562 }, "last_update_date": "2024-08-14T15:37:04.619000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006849" }, { "db": "NVD", "id": "CVE-2023-27019" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac10/8/8.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-27019" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-27019/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-27019" }, { "db": "JVNDB", "id": "JVNDB-2023-006849" }, { "db": "CNNVD", "id": "CNNVD-202304-485" }, { "db": "NVD", "id": "CVE-2023-27019" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-27019" }, { "db": "JVNDB", "id": "JVNDB-2023-006849" }, { "db": "CNNVD", "id": "CNNVD-202304-485" }, { "db": "NVD", "id": "CVE-2023-27019" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27019" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006849" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-485" }, { "date": "2023-04-07T02:15:08.470000", "db": "NVD", "id": "CVE-2023-27019" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-27019" }, { "date": "2023-11-16T06:59:00", "db": "JVNDB", "id": "JVNDB-2023-006849" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-485" }, { "date": "2023-04-13T18:03:57.287000", "db": "NVD", "id": "CVE-2023-27019" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-485" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006849" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-485" } ], "trust": 0.6 } }
var-202403-0797
Vulnerability from variot
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0797", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "15.03.06.49" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-34382" } ] }, "cve": "CVE-2024-2710", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CVE-2024-2710", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.0, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-34382", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2024-2710", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-2710", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-34382", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-34382" }, { "db": "NVD", "id": "CVE-2024-2710" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service", "sources": [ { "db": "NVD", "id": "CVE-2024-2710" }, { "db": "CNVD", "id": "CNVD-2024-34382" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-2710", "trust": 1.6 }, { "db": "VULDB", "id": "257461", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-34382", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-34382" }, { "db": "NVD", "id": "CVE-2024-2710" } ] }, "id": "VAR-202403-0797", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-34382" } ], "trust": 0.86649562 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-34382" } ] }, "last_update_date": "2024-08-15T12:29:04.701000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda AC10 setSchedWifi function buffer overflow vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/575541" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-34382" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-2710" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac10u/v1.v15.03.06.49/more/setschedwifi_start.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.257461" }, { "trust": 1.0, "url": "https://vuldb.com/?id.257461" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2710" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-34382" }, { "db": "NVD", "id": "CVE-2024-2710" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-34382" }, { "db": "NVD", "id": "CVE-2024-2710" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-08-02T00:00:00", "db": "CNVD", "id": "CNVD-2024-34382" }, { "date": "2024-03-20T18:15:11.907000", "db": "NVD", "id": "CVE-2024-2710" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-08-02T00:00:00", "db": "CNVD", "id": "CNVD-2024-34382" }, { "date": "2024-05-17T02:38:26.493000", "db": "NVD", "id": "CVE-2024-2710" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 setSchedWifi function buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-34382" } ], "trust": 0.6 } }