CVE-2024-4549
Vulnerability from cvelistv5
Published
2024-05-06 13:54
Modified
2024-08-01 20:47
Summary
A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. When processing an 'ICS Restart!' message, CEBC.exe restarts the system.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "diaenergie",
            "vendor": "deltaww",
            "versions": [
              {
                "lessThanOrEqual": "1.10.1.8610",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4549",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-06T15:35:29.745502Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-400",
                "description": "CWE-400 Uncontrolled Resource Consumption",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-20T20:08:39.537Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:47:41.185Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2024-13"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "DIAEnergie",
          "vendor": "Delta Electronics",
          "versions": [
            {
              "lessThanOrEqual": "1.10.1.8610",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. When processing an \u0027ICS Restart!\u0027 message, CEBC.exe restarts the system."
            }
          ],
          "value": "A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. When processing an \u0027ICS Restart!\u0027 message, CEBC.exe restarts the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-06T20:47:40.285Z",
        "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "shortName": "tenable"
      },
      "references": [
        {
          "url": "https://www.tenable.com/security/research/tra-2024-13"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Delta Electronics DIAEnergie SQL Injection ",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
    "assignerShortName": "tenable",
    "cveId": "CVE-2024-4549",
    "datePublished": "2024-05-06T13:54:32.808Z",
    "dateReserved": "2024-05-06T13:35:44.109Z",
    "dateUpdated": "2024-08-01T20:47:41.185Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-4549\",\"sourceIdentifier\":\"vulnreport@tenable.com\",\"published\":\"2024-05-06T14:15:08.717\",\"lastModified\":\"2024-11-21T09:43:05.050\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. When processing an \u0027ICS Restart!\u0027 message, CEBC.exe restarts the system.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de denegaci\u00f3n de servicio en Delta Electronics DIAEnergie v1.10.1.8610 y anteriores. Al procesar un mensaje \u0027ICS Restart!, CEBC.exe reinicia el sistema.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"vulnreport@tenable.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"references\":[{\"url\":\"https://www.tenable.com/security/research/tra-2024-13\",\"source\":\"vulnreport@tenable.com\"},{\"url\":\"https://www.tenable.com/security/research/tra-2024-13\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.