CVE-2024-23958
Vulnerability from cvelistv5
Published
2024-09-28 06:10
Modified
2024-10-03 13:48
Severity ?
EPSS score ?
Summary
Autel MaxiCharger AC Elite Business C50 BLE Hardcoded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Autel MaxiCharger AC Elite Business C50 charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the BLE AppAuthenRequest command handler. The handler uses hardcoded credentials as a fallback in case of an authentication request failure. An attacker can leverage this vulnerability to bypass authentication on the system.
Was ZDI-CAN-23196
References
▼ | URL | Tags | |
---|---|---|---|
cve@asrg.io | https://www.zerodayinitiative.com/advisories/ZDI-24-852/ | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Autel | MaxiCharger AC Elite Business C50 |
Version: 1.32.00 |
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:autel:maxicharger_ac_elite_business_c50_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "maxicharger_ac_elite_business_c50_firmware", "vendor": "autel", "versions": [ { "lessThan": "1.35", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:autel:maxicharger_ac_elite_business_c50_eu_firmware:1.50:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "maxicharger_ac_elite_business_c50_eu_firmware", "vendor": "autel", "versions": [ { "lessThan": "1.50", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-23958", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-03T13:48:26.335697Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-03T13:48:39.497Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "MaxiCharger AC Elite Business C50", "vendor": "Autel", "versions": [ { "status": "affected", "version": "1.32.00" } ] } ], "dateAssigned": "2024-01-25T03:46:00.000Z", "datePublic": "2024-06-21T23:42:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eAutel MaxiCharger AC Elite Business C50 BLE Hardcoded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Autel MaxiCharger AC Elite Business C50 charging stations. Authentication is not required to exploit this vulnerability.\u003c/p\u003e\u003cp\u003eThe specific flaw exists within the BLE AppAuthenRequest command handler. The handler uses hardcoded credentials as a fallback in case of an authentication request failure. An attacker can leverage this vulnerability to bypass authentication on the system.\u003c/p\u003e\u003cp\u003eWas ZDI-CAN-23196\u003c/p\u003e" } ], "value": "Autel MaxiCharger AC Elite Business C50 BLE Hardcoded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Autel MaxiCharger AC Elite Business C50 charging stations. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the BLE AppAuthenRequest command handler. The handler uses hardcoded credentials as a fallback in case of an authentication request failure. An attacker can leverage this vulnerability to bypass authentication on the system.\n\nWas ZDI-CAN-23196" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "CWE-798: Use of Hard-coded Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-28T06:10:32.811Z", "orgId": "c15abc07-96a9-4d11-a503-5d621bfe42ba", "shortName": "ASRG" }, "references": [ { "name": "ZDI-24-852", "tags": [ "x_research-advisory" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-852/" } ], "source": { "discovery": "UNKNOWN", "lang": "en", "value": "Synacktiv (@Synacktiv)" }, "title": "Autel MaxiCharger AC Elite Business C50 BLE Hardcoded Credentials Authentication Bypass Vulnerability", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "c15abc07-96a9-4d11-a503-5d621bfe42ba", "assignerShortName": "ASRG", "cveId": "CVE-2024-23958", "datePublished": "2024-09-28T06:10:32.811Z", "dateReserved": "2024-01-25T00:14:40.298Z", "dateUpdated": "2024-10-03T13:48:39.497Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-23958\",\"sourceIdentifier\":\"cve@asrg.io\",\"published\":\"2024-09-28T07:15:03.183\",\"lastModified\":\"2024-10-03T17:42:05.553\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Autel MaxiCharger AC Elite Business C50 BLE Hardcoded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Autel MaxiCharger AC Elite Business C50 charging stations. Authentication is not required to exploit this vulnerability.\\n\\nThe specific flaw exists within the BLE AppAuthenRequest command handler. The handler uses hardcoded credentials as a fallback in case of an authentication request failure. An attacker can leverage this vulnerability to bypass authentication on the system.\\n\\nWas ZDI-CAN-23196\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n de credenciales codificadas de Autel MaxiCharger AC Elite Business C50 BLE. Esta vulnerabilidad permite a los atacantes adyacentes a la red omitir la autenticaci\u00f3n en las instalaciones afectadas de las estaciones de carga Autel MaxiCharger AC Elite Business C50. No se requiere autenticaci\u00f3n para explotar esta vulnerabilidad. La falla espec\u00edfica existe dentro del controlador de comandos AppAuthenRequest de BLE. El controlador usa credenciales codificadas de forma r\u00edgida como respaldo en caso de que falle una solicitud de autenticaci\u00f3n. Un atacante puede aprovechar esta vulnerabilidad para omitir la autenticaci\u00f3n en el sistema. Era ZDI-CAN-23196\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@asrg.io\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cve@asrg.io\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:autel:maxicharger_ac_elite_business_c50_firmware:1.32.00:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8AE968C0-3E5C-4A7A-9687-C6D7208224E7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:autel:maxicharger_ac_elite_business_c50:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5B2F9001-71B7-4B39-9114-FC54F4EAE9E7\"}]}]}],\"references\":[{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-24-852/\",\"source\":\"cve@asrg.io\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.