{"vulnerability": "CVE-2026-0936", "sightings": [{"uuid": "a3b04822-2bb1-4ebb-88e8-27deda9ac921", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2026-0936", "type": "seen", "source": "https://bsky.app/profile/cve.skyfleet.blue/post/3mdldiwrsyg2m", "content": "", "creation_timestamp": "2026-01-29T17:41:29.187756Z"}, {"uuid": "44db9ade-914c-4bd4-b041-bbf2dc3a52f7", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2026-0936", "type": "seen", "source": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-125-02", "content": "View CSAF\n\nSummary\n\nABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is now available that addresses and remediates the vulnerability. An attacker who successfully exploited this vulnerability could read sensitive information in the logging data of the PVI client application. Logging is deactivated by default in all PVI client versions.\n\nThe following versions of ABB B&amp;R PVI are affected:\n\n\n\nPVI &lt;6.5.0, 6.5.0 (CVE-2026-0936)\n\n&lt;div class=\"csaf-table\"&gt;\n\n\n\n\nCVSS\nVendor\nEquipment\nVulnerabilities\n\n\n\n\nv3 5\nABB\nABB B&amp;R PVI\nInsertion of Sensitive Information into Log File\n\n\n\n&lt;/div&gt;\n\nBackground\n\n\n\nCritical Infrastructure Sectors: Energy\n\nCountries/Areas Deployed: Worldwide\n\nCompany Headquarters Location: Switzerland\n\n\n\n\nVulnerabilities\n&lt;div class=\"csaf-accordion\"&gt;\n\nExpand All +\n&lt;div class=\"csaf-accordion-item\"&gt;\n\nCVE-2026-0936\n&lt;div class=\"csaf-accordion-content\"&gt;\n\nAn Insertion of Sensitive Information into Log File vulnerability in B&amp;R PVI client versions prior to 6.5 may be abused by an authenticated local attacker to gather credential information which is processed by the PVI client application. The logging function of the PVI client application is disabled by default and must be explicitly enabled by the user.\n\nView CVE Details\n\n\n\nAffected Products\n\nABB B&amp;R PVI\n&lt;div class=\"ics-vendor-version-status\"&gt;\n&lt;div class=\"ics-vendor\"&gt;Vendor:ABB&lt;/div&gt;\n&lt;div class=\"ics-version\"&gt;Product Version:ABB PVI &lt;6.5.0&lt;/div&gt;\n&lt;div class=\"ics-status\"&gt;Product Status:fixed, known_affected&lt;/div&gt;\n&lt;/div&gt;\n&lt;div class=\"ics-remediations\"&gt;\n\nRemediations\n\nVendor fixThe problem is corrected in the following product versions: - PVI 6.5.0 Please note that PVI is included in the Automation Studio installation package and shares the same version number as the corresponding Automation Studio release. B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.\n\nMitigationThis vulnerability is limited to the PVI client side application logging and does not impact any security related logging of the PVI server component. Logging is not enabled by default for PVI client applications. Activate logging on the client system only when it is required for troubleshooting, debugging or analysis. Ensure that all client side logging information is securely deleted after it is no longer needed. When enabling logging in PVI client applications, the storage path for the log files must be specified. Make sure that only the respective user has access to the directories where the logging information is stored. Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.\n&lt;/div&gt;\n\nRelevant CWE: CWE-532 Insertion of Sensitive Information into Log File\n\n\n\nMetrics\n&lt;div class=\"csaf-table csaf-metrics-table\"&gt;\n\n\n\n\nCVSS Version\nBase Score\nBase Severity\nVector String\n\n\n\n\n3.1\n5\nMEDIUM\nCVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N/E:U/RL:O/RC:C\n\n\n\n&lt;/div&gt;\n&lt;/div&gt;\n&lt;/div&gt;\n&lt;/div&gt;\n\n\n\nAcknowledgments\n\n\n\nABB PSIRT reported this vulnerability to CISA.\n\n\n\n\nNotice\n\nThe information in this document is subject to change without notice, and should not be construed as a commitment by B&amp;R. B&amp;R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B&amp;R or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B&amp;R or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from B&amp;R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.\n\n\n\nLegal Notice and Terms of Use\n\nThis product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).\n\n\n\nRecommended Practices\n\nCISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.\n\nLocate control system networks and remote devices behind firewalls and isolate them from business networks.\n\nWhen remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.\n\nCISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\n\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.\n\nCISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\n\nOrganizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.\n\n\n\nAdvisory Conversion Disclaimer\n\nThis ICSA is a verbatim republication of ABB PSIRT SA26P001 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.\n\nRevision History\n\n\n\nInitial Release Date: 2026-01-29\n\n\n\n\n\nDate\nRevision\nSummary\n\n\n\n\n2026-01-29\n1\nInitial version.\n\n\n2026-05-05\n2\nInitial CISA Republication of ABB PSIRT SA26P001 advisory\n\n\n\n\n\n\nLegal Notice and Terms of Use", "creation_timestamp": "2026-05-05T10:00:00.000000Z"}]}