{"vulnerability": "CVE-2024-11166", "sightings": [{"uuid": "1eedb9da-8b23-4e5b-a704-95911114a5c1", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2024-11166", "type": "seen", "source": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-021-01", "content": "", "creation_timestamp": "2025-01-21T11:00:00.000000Z"}, {"uuid": "b8f04ec2-0bc0-4e91-9f20-cbdad72cae39", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2024-11166", "type": "seen", "source": "https://t.me/DarkWebInformer_CVEAlerts/2613", "content": "\ud83d\udd17 DarkWebInformer.com - Cyber Threat Intelligence\n\ud83d\udccc CVE ID: CVE-2024-11166\n\ud83d\udd39 Description: For TCAS II systems using transponders compliant with MOPS earlier than RTCA DO-181F, an attacker can impersonate a ground station and issue a Comm-A Identity Request. This action can set the Sensitivity Level Control (SLC) to the lowest setting and disable the Resolution Advisory (RA), leading to a denial-of-service condition.\n\ud83d\udccf Published: 2025-01-22T18:40:30.977Z\n\ud83d\udccf Modified: 2025-01-22T18:40:30.977Z\n\ud83d\udd17 References:\n1. https://www.cisa.gov/news-events/ics-advisories/icsa-25-021-01", "creation_timestamp": "2025-01-22T19:02:47.000000Z"}, {"uuid": "3b499d66-fe16-410e-9597-25943a494c1e", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2024-11166", "type": "seen", "source": "https://bsky.app/profile/cve-notifications.bsky.social/post/3lge3cgo22427", "content": "", "creation_timestamp": "2025-01-22T19:15:25.838043Z"}, {"uuid": "388cc11e-d030-461f-b1ca-521252ab43c3", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2024-11166", "type": "seen", "source": "https://bsky.app/profile/cve.skyfleet.blue/post/3lge5j6l42i2e", "content": "", "creation_timestamp": "2025-01-22T19:55:02.493056Z"}, {"uuid": "523b6b82-8967-40e1-a3ce-645b9fed85c4", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2024-11166", "type": "seen", "source": "https://t.me/cvedetector/16139", "content": "{\n  \"Source\": \"CVE FEED\",\n  \"Title\": \"CVE-2024-11166 - Rockwell Collins TCAS II Transponder Ground Station Impersonation Vulnerability\", \n  \"Content\": \"CVE ID : CVE-2024-11166 \nPublished : Jan. 22, 2025, 7:15 p.m. | 19\u00a0minutes ago \nDescription : For TCAS II systems using transponders compliant with MOPS earlier than RTCA DO-181F, an attacker can impersonate a ground station and issue a Comm-A Identity Request. This action can set the Sensitivity Level Control (SLC) to the lowest setting and disable the Resolution Advisory (RA), leading to a denial-of-service condition. \nSeverity: 0.0 | NA \nVisit the link for more details, such as CVSS details, affected products, timeline, and more...\",\n  \"Detection Date\": \"22 Jan 2025\",\n  \"Type\": \"Vulnerability\"\n}\n\ud83d\udd39 t.me/cvedetector \ud83d\udd39", "creation_timestamp": "2025-01-22T20:35:05.000000Z"}]}