{"vulnerability": "CVE-2022-30694", "sightings": [{"uuid": "f068f5f1-1a77-488f-8c80-913b245aa76d", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2022-30694", "type": "seen", "source": "https://t.me/cibsecurity/52635", "content": "\u203c CVE-2022-30694 \u203c\n\nA vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions &lt; V3.2.19), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions &lt; V3.2.19), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions &lt; V3.2.19), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions &lt; V3.2.19), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions &lt; V3.2.19), SIMATIC PC Station (All versions &gt;= V2.1), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions &lt; V3.3.19), SIMATIC S7-300 CPU 315-2 PN/DP (All versions &lt; V3.2.19), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions &lt; V3.2.19), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions &lt; V3.2.19), SIMATIC S7-300 CPU 317-2 PN/DP (All versions &lt; V3.2.19), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions &lt; V3.2.19), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions &lt; V3.2.19), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions &lt; V3.2.19), SIMATIC S7-300 CPU 319-3 PN/DP (All versions &lt; V3.2.19), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions &lt; V3.2.19), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-PLCSIM Advanced (All versions), SIMATIC WinCC Runtime Advanced (All versions), SINUMERIK ONE (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions &lt; V3.2.19), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions &lt; V3.2.19), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions &lt; V3.3.19), SIPLUS S7-300 CPU 315-2 PN/DP (All versions &lt; V3.2.19), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions &lt; V3.2.19), SIPLUS S7-300 CPU 317-2 PN/DP (All versions &lt; V3.2.19), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions &lt; V3.2.19). The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.\n\n\ud83d\udcd6 Read\n\nvia \"National Vulnerability Database\".", "creation_timestamp": "2022-11-08T14:35:27.000000Z"}]}