{"vulnerability": "CVE-2021-38393", "sightings": [{"uuid": "c76b6438-bd6c-4bda-a22b-043a3ea0d100", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2021-38393", "type": "seen", "source": "https://t.me/cibsecurity/28022", "content": "\u203c CVE-2021-38393 \u203c\n\nA Blind SQL injection vulnerability exists in the /DataHandler/HandlerAlarmGroup.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter agid before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\\MSSQLSERVER.\n\n\ud83d\udcd6 Read\n\nvia \"National Vulnerability Database\".", "creation_timestamp": "2021-08-30T22:32:34.000000Z"}]}