<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent sightings.</title>
    <link>https://vulnerability.circl.lu</link>
    <description>Contains only the most 10 recent sightings.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 18 Jul 2026 14:26:02 +0000</lastBuildDate>
    <item>
      <title>13efcbd4-3b94-41d3-acd7-f537188fbf66</title>
      <link>https://vulnerability.circl.lu/sighting/13efcbd4-3b94-41d3-acd7-f537188fbf66/export</link>
      <description>{"uuid": "13efcbd4-3b94-41d3-acd7-f537188fbf66", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2018-14781", "type": "seen", "source": "https://t.me/DarkWebInformer_CVEAlerts/17305", "content": "\ud83d\udd17 DarkWebInformer.com - Cyber Threat Intelligence\n\ud83d\udccc CVE ID: CVE-2018-14781\n\ud83d\udd25 CVSS Score: 5.3 (cvssV3_1, Vector: CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N)\n\ud83d\udd39 Description: Medtronic MiniMed MMT \n\ndevices when paired with a remote controller and having the \u201ceasy bolus\u201d and \u201cremote bolus\u201d options enabled (non-default), are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them to cause an insulin (bolus) delivery.\n\ud83d\udccf Published: 2018-08-13T22:00:00Z\n\ud83d\udccf Modified: 2025-05-22T16:33:08.385Z\n\ud83d\udd17 References:\n1. https://global.medtronic.com/xg-en/product-security/security-bulletins/minimed.html\n2. https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-02\n3. http://www.securityfocus.com/bid/105044", "creation_timestamp": "2025-05-22T16:43:25.000000Z"}</description>
      <content:encoded>{"uuid": "13efcbd4-3b94-41d3-acd7-f537188fbf66", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2018-14781", "type": "seen", "source": "https://t.me/DarkWebInformer_CVEAlerts/17305", "content": "\ud83d\udd17 DarkWebInformer.com - Cyber Threat Intelligence\n\ud83d\udccc CVE ID: CVE-2018-14781\n\ud83d\udd25 CVSS Score: 5.3 (cvssV3_1, Vector: CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N)\n\ud83d\udd39 Description: Medtronic MiniMed MMT \n\ndevices when paired with a remote controller and having the \u201ceasy bolus\u201d and \u201cremote bolus\u201d options enabled (non-default), are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them to cause an insulin (bolus) delivery.\n\ud83d\udccf Published: 2018-08-13T22:00:00Z\n\ud83d\udccf Modified: 2025-05-22T16:33:08.385Z\n\ud83d\udd17 References:\n1. https://global.medtronic.com/xg-en/product-security/security-bulletins/minimed.html\n2. https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-02\n3. http://www.securityfocus.com/bid/105044", "creation_timestamp": "2025-05-22T16:43:25.000000Z"}</content:encoded>
      <guid isPermaLink="false">https://vulnerability.circl.lu/sighting/13efcbd4-3b94-41d3-acd7-f537188fbf66/export</guid>
      <pubDate>Thu, 22 May 2025 16:43:25 +0000</pubDate>
    </item>
  </channel>
</rss>
