cve-2023-5247
Vulnerability from cvelistv5
Published
2023-11-30 03:57
Modified
2024-12-02 19:02
Severity ?
EPSS score ?
Summary
Malicious Code Execution Vulnerability due to External Control of File Name or Path in multiple Mitsubishi Electric FA Engineering Software Products allows a malicious attacker to execute a malicious code by having legitimate users open a specially crafted project file, which could result in information disclosure, tampering and deletion, or a denial-of-service (DoS) condition.
References
▼ | URL | Tags |
---|---|---|
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-016_en.pdf | vendor-advisory | |
https://jvn.jp/vu/JVNVU93383160/ | government-resource |
Impacted products
Vendor | Product | Version | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Mitsubishi Electric Corporation | GX Works3 |
Version: all versions |
||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T07:52:08.538Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-016_en.pdf" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU93383160/" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-5247", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-12-02T19:02:13.903376Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-12-02T19:02:32.708Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "GX Works3", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT iQ AppPortal", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT Navigator", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "Motion Control Setting", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Malicious Code Execution Vulnerability due to External Control of File Name or Path in multiple Mitsubishi Electric FA Engineering Software Products allows a malicious attacker to execute a malicious code by having legitimate users open a specially crafted project file, which could result in information disclosure, tampering and deletion, or a denial-of-service (DoS) condition." } ], "value": "Malicious Code Execution Vulnerability due to External Control of File Name or Path in multiple Mitsubishi Electric FA Engineering Software Products allows a malicious attacker to execute a malicious code by having legitimate users open a specially crafted project file, which could result in information disclosure, tampering and deletion, or a denial-of-service (DoS) condition." } ], "impacts": [ { "descriptions": [ { "lang": "en", "value": "Malicious Code Execution" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-73", "description": "CWE-73 External Control of File Name or Path", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-30T03:57:30.083Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-016_en.pdf" }, { "tags": [ "government-resource" ], "url": "https://jvn.jp/vu/JVNVU93383160/" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2023-5247", "datePublished": "2023-11-30T03:57:30.083Z", "dateReserved": "2023-09-28T07:26:44.445Z", "dateUpdated": "2024-12-02T19:02:32.708Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-4088
Vulnerability from cvelistv5
Published
2023-09-20 02:26
Modified
2024-09-24 18:27
Severity ?
EPSS score ?
Summary
Malicious Code Execution Vulnerability in FA Engineering Software Products
References
▼ | URL | Tags |
---|---|---|
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-010_en.pdf | vendor-advisory | |
https://jvn.jp/vu/JVNVU96447193/index.html | government-resource | |
https://www.cisa.gov/news-events/ics-advisories/icsa-23-269-03 | government-resource |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T07:17:12.060Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-010_en.pdf" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU96447193/index.html" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-269-03" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-4088", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-09-24T18:27:00.307770Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-24T18:27:11.655Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "GX Works3", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "AL-PCS/WIN-E", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "CPU Module Logging Configuration Tool", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "EZSocket", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "FR Configurator2", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "FX Configurator-EN", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "FX Configurator-EN-L", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "FX Configurator-FP", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "GT Designer3 Version1(GOT1000)", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "GT Designer3 Version1(GOT2000)", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "GT SoftGOT1000 Version3", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "GT SoftGOT2000 Version1", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "GX LogViewer", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "GX Works2", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT FieldDeviceConfigurator", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT iQ AppPortal", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT MaiLab", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT Navigator", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT Update Manager", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MX Component", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MX Sheet", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "PX Developer", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "RT ToolBox3", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "RT VisualBox", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "Data Transfer", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "Data Transfer Classic", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder." } ], "value": "Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder." } ], "impacts": [ { "descriptions": [ { "lang": "en", "value": "Malicious Code Execution" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 9.3, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-276", "description": "CWE-276 Incorrect Default Permissions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-04T09:16:28.950Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-010_en.pdf" }, { "tags": [ "government-resource" ], "url": "https://jvn.jp/vu/JVNVU96447193/index.html" }, { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-269-03" } ], "source": { "discovery": "UNKNOWN" }, "title": "Malicious Code Execution Vulnerability in FA Engineering Software Products", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2023-4088", "datePublished": "2023-09-20T02:26:43.901Z", "dateReserved": "2023-08-02T04:52:49.923Z", "dateUpdated": "2024-09-24T18:27:11.655Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }