    <title>CVE-2026-89465 — power: supply: rt9455: quiesce delayed work before teardown</title>
    <updated>2026-09-29T11:35:13.783099+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p><strong>Affected:</strong> Linux</p>
<p>In the Linux kernel, the following vulnerability has been resolved:</p>
<p>power: supply: rt9455: quiesce delayed work before teardown</p>
<p>The threaded IRQ handler can queue pwr_rdy_work,
max_charging_time_work and batt_presence_work.  pwr_rdy_work and
batt_presence_work can also queue max_charging_time_work, while
batt_presence_work can requeue itself.</p>
<p>rt9455_remove() cancels max_charging_time_work before
batt_presence_work.  The latter can therefore queue
max_charging_time_work after it has already been cancelled:</p>
<p>rt9455_remove()                   workqueue
    cancel pwr_rdy_work
    cancel max_charging_time_work
                                      batt_presence_work queues
                                        max_charging_time_work
    cancel batt_presence_work
    return
    devres frees rt9455_info
                                      max_charging_time_work dereferences
                                        rt9455_info</p>
<p>The IRQ also remains registered until devres cleanup and can queue more
work after any of the cancellation calls.  If rt9455_hw_init() fails
after the IRQ has been requested, probe returns without cancelling work
that may already have been queued.  A pending callback can then access
rt9455_info after it has been freed.</p>
<p>Register rt9455_cancel_all_delayed_works() through
devm_add_action_or_reset() right after devm_power_supply_register().
devres invokes the action in reverse registration order, after the
managed IRQ has been freed and before rt9455_in…</p></div>