    <title>CVE-2026-74547 — hwmon: (adt7470) Fix busy-loop and I2C flooding in update thread</title>
    <updated>2026-09-30T02:04:40.219075+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p><strong>Affected:</strong> Linux</p>
<p>In the Linux kernel, the following vulnerability has been resolved:</p>
<p>hwmon: (adt7470) Fix busy-loop and I2C flooding in update thread</p>
<p>When userspace configures 'auto_update_interval' to 0 via sysfs, the
background kthread executes schedule_timeout_interruptible(0), which
returns immediately.</p>
<p>If 'num_temp_sensors' is concurrently or previously set to 0, the
msleep_interruptible() delay inside adt7470_read_temperatures() also
becomes 0. This combination forces the background thread into a tight,
unbounded busy-loop, hogging the CPU and flooding the I2C bus with a
continuous stream of transactions.</p>
<p>Fix this vulnerability by raising the lower limit of the clamp_val in
auto_update_interval_store() from 0 to 500 milliseconds. This guarantees
a reasonable minimum sleep window between sensor updates, protecting the
system from intentional or accidental I2C bus denial of service.</p></div>