<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://vulnerability.circl.lu/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-09-30T21:12:19.414919+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>info@circl.lu</email>
  </author>
  <link href="https://vulnerability.circl.lu" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://vulnerability.circl.lu/vuln/cve-2023-53245</id>
    <title>CVE-2023-53245 — scsi: storvsc: Fix handling of virtual Fibre Channel timeouts</title>
    <updated>2026-09-30T21:12:19.905905+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p><strong>Affected:</strong> Linux</p>
<p>In the Linux kernel, the following vulnerability has been resolved:</p>
<p>scsi: storvsc: Fix handling of virtual Fibre Channel timeouts</p>
<p>Hyper-V provides the ability to connect Fibre Channel LUNs to the host
system and present them in a guest VM as a SCSI device. I/O to the vFC
device is handled by the storvsc driver. The storvsc driver includes a
partial integration with the FC transport implemented in the generic
portion of the Linux SCSI subsystem so that FC attributes can be displayed
in /sys.  However, the partial integration means that some aspects of vFC
don't work properly. Unfortunately, a full and correct integration isn't
practical because of limitations in what Hyper-V provides to the guest.</p>
<p>In particular, in the context of Hyper-V storvsc, the FC transport timeout
function fc_eh_timed_out() causes a kernel panic because it can't find the
rport and dereferences a NULL pointer. The original patch that added the
call from storvsc_eh_timed_out() to fc_eh_timed_out() is faulty in this
regard.</p>
<p>In many cases a timeout is due to a transient condition, so the situation
can be improved by just continuing to wait like with other I/O requests
issued by storvsc, and avoiding the guaranteed panic. For a permanent
failure, continuing to wait may result in a hung thread instead of a panic,
which again may be better.</p>
<p>So fix the panic by removing the storvsc call to fc_eh_timed_out().  This
allows storvsc to keep waiting for a response.  The change has been tested
by users who expe…</p></div>
    </content>
    <link href="https://vulnerability.circl.lu/vuln/cve-2023-53245"/>
  </entry>
</feed>
