<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://vulnerability.circl.lu/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-09-28T15:46:51.512500+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>info@circl.lu</email>
  </author>
  <link href="https://vulnerability.circl.lu" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://vulnerability.circl.lu/vuln/bdu:2026-07281</id>
    <title>bdu:2026-07281</title>
    <updated>2026-09-28T15:46:51.552189+00:00</updated>
    <content>bdu:2026-07281</content>
    <link href="https://vulnerability.circl.lu/vuln/bdu:2026-07281"/>
  </entry>
  <entry>
    <id>https://vulnerability.circl.lu/vuln/fkie_cve-2026-9362</id>
    <title>fkie_cve-2026-9362</title>
    <updated>2026-09-28T15:46:51.552273+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A security vulnerability has been detected in Edimax EW-7438RPn 1.12. This vulnerability affects the function formConnectionSetting of the file /goform/formConnectionSetting of the component Setting Handler. Such manipulation of the argument max_Conn/timeOut leads to command injection. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.</p>
      </div>
    </content>
    <link href="https://vulnerability.circl.lu/vuln/fkie_cve-2026-9362"/>
  </entry>
  <entry>
    <id>https://vulnerability.circl.lu/vuln/ghsa-fcv6-974v-wfp4</id>
    <title>GHSA-fcv6-974v-wfp4</title>
    <updated>2026-09-28T15:46:51.552334+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A security vulnerability has been detected in Edimax EW-7438RPn 1.12. This vulnerability affects the function formConnectionSetting of the file /goform/formConnectionSetting of the component Setting Handler. Such manipulation of the argument max_Conn/timeOut leads to command injection. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.</p>
      </div>
    </content>
    <link href="https://vulnerability.circl.lu/vuln/ghsa-fcv6-974v-wfp4"/>
  </entry>
</feed>
