Max CVSS 10.0 Min CVSS 2.1 Total Count2
IDCVSSSummaryLast (major) updatePublished
CVE-2018-3842 6.8
An exploitable use of an uninitialized pointer vulnerability exists in the JavaScript engine in Foxit PDF Reader version 9.0.1.1049. A specially crafted PDF document can lead to a dereference of an uninitialized pointer which, if under attacker contr
04-02-2023 - 01:12 19-04-2018 - 19:29
CVE-2018-3843 6.8
An exploitable type confusion vulnerability exists in the way Foxit PDF Reader version 9.0.1.1049 parses files with associated file annotations. A specially crafted PDF document can lead to an object of invalid type to be dereferenced, which can pote
03-02-2023 - 19:07 19-04-2018 - 19:29
CVE-2018-3850 6.8
An exploitable use-after-free vulnerability exists in the JavaScript engine Foxit Software Foxit PDF Reader version 9.0.1.1049. A specially crafted PDF document can trigger a previously freed object in memory to be reused, resulting in arbitrary code
31-01-2023 - 20:15 23-04-2018 - 15:29
CVE-2017-14458 6.8
An exploitable use-after-free vulnerability exists in the JavaScript engine of Foxit Software's Foxit PDF Reader version 8.3.2.25013. A specially crafted PDF document can trigger a previously freed object in memory to be reused, resulting in arbitrar
28-01-2023 - 01:54 23-04-2018 - 15:29
CVE-2018-3853 6.8
An exploitable use-after-free vulnerability exists in the JavaScript engine of Foxit Software Foxit PDF Reader version 9.0.1.1049. A specially crafted PDF document can trigger a previously freed object in memory to be reused resulting in arbitrary co
03-12-2022 - 14:19 04-06-2018 - 20:29
CVE-2018-8872 9.3
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied
09-10-2019 - 23:43 04-05-2018 - 17:29
CVE-2018-8840 10.0
A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow r
09-10-2019 - 23:42 18-04-2018 - 20:29
CVE-2018-7522 7.2
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access an
09-10-2019 - 23:42 04-05-2018 - 17:29
CVE-2018-0257 3.3
A vulnerability in Cisco IOS XE Software running on Cisco cBR Series Converged Broadband Routers could allow an unauthenticated, adjacent attacker to cause high CPU usage on an affected device, resulting in a denial of service (DoS) condition. The vu
09-10-2019 - 23:31 19-04-2018 - 20:29
CVE-2018-0243 5.0
A vulnerability in the detection engine of Cisco Firepower System Software could allow an unauthenticated, remote attacker to bypass a configured file action policy that is intended to drop the Server Message Block Version 2 (SMB2) and SMB Version 3
09-10-2019 - 23:31 19-04-2018 - 20:29
CVE-2018-0260 5.0
A vulnerability in the web interface of Cisco MATE Live could allow an unauthenticated, remote attacker to view and download the contents of certain web application virtual directories. The vulnerability is due to lack of proper input validation and
09-10-2019 - 23:31 19-04-2018 - 20:29
CVE-2018-0244 5.0
A vulnerability in the detection engine of Cisco Firepower System Software could allow an unauthenticated, remote attacker to bypass a configured file action policy to drop the Server Message Block (SMB) protocol if a malware file is detected. The vu
09-10-2019 - 23:31 19-04-2018 - 20:29
CVE-2018-0254 5.0
A vulnerability in the detection engine of Cisco Firepower System Software could allow an unauthenticated, remote attacker to bypass configured file action policies if an Intelligent Application Bypass (IAB) with a drop percentage threshold is also c
09-10-2019 - 23:31 19-04-2018 - 20:29
CVE-2018-4847 2.1
A vulnerability has been identified in SIMATIC WinCC OA Operator iOS App (All versions < V1.4). Insufficient protection of sensitive information (e.g. session key for accessing server) in Siemens WinCC OA Operator iOS app could allow an attacker with
03-10-2019 - 00:03 23-04-2018 - 16:29
CVE-2004-2259 5.0
vsftpd before 1.2.2, when under heavy load, allows attackers to cause a denial of service (crash) via a SIGCHLD signal during a malloc or free call, which is not re-entrant.
11-10-2017 - 01:29 31-12-2004 - 05:00
Back to Top Mark selected
Back to Top