ID CVE-2017-10265
Summary Vulnerability in the Oracle Integrated Lights Out Manager (ILOM) component of Oracle Sun Systems Products Suite (subcomponent: System Management). The supported version that is affected is Prior to 3.2.6. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Integrated Lights Out Manager (ILOM). Successful attacks of this vulnerability can result in unauthorized update, insert or delete access to some of Oracle Integrated Lights Out Manager (ILOM) accessible data as well as unauthorized read access to a subset of Oracle Integrated Lights Out Manager (ILOM) accessible data and unauthorized ability to cause a partial denial of service (partial DOS) of Oracle Integrated Lights Out Manager (ILOM). CVSS 3.0 Base Score 7.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L).
References
Vulnerable Configurations
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.0:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.0:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.3:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.3:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.4:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.4:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.6:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.6:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.8:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.8:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.9:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.9:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.10:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.10:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.12:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.12:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.14:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.14:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.16:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.16:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.1:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.1:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.1.0:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.1.0:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.1.1:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.1.1:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.1.2:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.1.2:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.0:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.0:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.1:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.1:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.2:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.2:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.3:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.3:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.4:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.4:*:*:*:*:*:*:*
  • cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.5:*:*:*:*:*:*:*
CVSS
Base: 7.5 (as of 03-10-2019 - 00:03)
Impact:
Exploitability:
CWE NVD-CWE-noinfo
CAPEC
Access
VectorComplexityAuthentication
NETWORK LOW NONE
Impact
ConfidentialityIntegrityAvailability
PARTIAL PARTIAL PARTIAL
cvss-vector via4 AV:N/AC:L/Au:N/C:P/I:P/A:P
refmap via4
bid 101431
confirm http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html
Last major update 03-10-2019 - 00:03
Published 19-10-2017 - 17:29
Last modified 03-10-2019 - 00:03
Back to Top