ID CVE-2018-11465
Summary A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could use ioctl calls to do out of bounds reads, arbitrary writes, or execute code in kernel mode. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
Vulnerable Configurations
  • cpe:2.3:o:siemens:sinumerik_808d_v4.7_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:sinumerik_808d_v4.7_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:sinumerik_808d_v4.7:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:sinumerik_808d_v4.7:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:sinumerik_808d_v4.8_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:sinumerik_808d_v4.8_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:sinumerik_808d_v4.8:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:sinumerik_808d_v4.8:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:sinumerik_828d_v4.7_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:sinumerik_828d_v4.7_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:sinumerik_828d_v4.7:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:sinumerik_828d_v4.7:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:sinumerik_840d_sl_v4.7_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:sinumerik_840d_sl_v4.7_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:sinumerik_840d_sl_v4.7:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:sinumerik_840d_sl_v4.7:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:sinumerik_840d_sl_v4.8_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:sinumerik_840d_sl_v4.8_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:sinumerik_840d_sl_v4.8:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:sinumerik_840d_sl_v4.8:-:*:*:*:*:*:*:*
CVSS
Base: 7.2 (as of 09-10-2019 - 23:33)
Impact:
Exploitability:
CWE CWE-125
CAPEC
  • Infiltration of Hardware Development Environment
    An attacker, leveraging the ability to manipulate components of primary support systems and tools within the development and production environments, inserts malicious software within the hardware and/or firmware development environment. The infiltration purpose is to alter developed hardware components in a system destined for deployment at the victim's organization, for the purpose of disruption or further compromise.
  • Overread Buffers
    An adversary attacks a target by providing input that causes an application to read beyond the boundary of a defined buffer. This typically occurs when a value influencing where to start or stop reading is set to reflect positions outside of the valid memory location of the buffer. This type of attack may result in exposure of sensitive information, a system crash, or arbitrary code execution.
Access
VectorComplexityAuthentication
LOCAL LOW NONE
Impact
ConfidentialityIntegrityAvailability
COMPLETE COMPLETE COMPLETE
cvss-vector via4 AV:L/AC:L/Au:N/C:C/I:C/A:C
refmap via4
bid 106185
confirm https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf
Last major update 09-10-2019 - 23:33
Published 12-12-2018 - 16:29
Last modified 09-10-2019 - 23:33